Abstract
Randomized controlled trials evaluating low-target oxygen saturation (SpO2:85% to 89%) vs high-target SpO2 (91% to 95%) have shown variable results regarding mortality and morbidity in extremely preterm infants. Because of the variation inherent to the accuracy of pulse oximeters, the unspecified location of probe placement, the intrinsic relationship between SpO2 and arterial oxygen saturation (SaO2) and between SaO2 and partial pressure of oxygen (PaO2) (differences in oxygen dissociation curves for fetal and adult hemoglobin), the two comparison groups could have been more similar than dissimilar. The SpO2 values were in the target range for a shorter period of time than intended due to practical and methodological constraints. So the studies did not truly compare ‘target SpO2 ranges’. In spite of this overlap, some of the studies did find signficant differences in mortality prior to discharge, necrotizing enterocolitis and severe retinopathy of prematurity. These differences could potentially be secondary to time spent beyond the target range (SpO2 <85 or >95%) and could be avoided with an intermediate but wider target SpO2 range (87% to 93%). In conclusion, significant uncertainty persists about the desired target range of SpO2 in extremely preterm infants. Further studies should focus on studying newer methods of assessing oxygenation and strategies to limit hypoxemia (<85% SpO2) and hyperoxemia (>95% SpO2).
This is a preview of subscription content, access via your institution
Relevant articles
Open Access articles citing this article.
-
LED light can falsify pulse oximetry readings via the stroboscopic effect
Physical and Engineering Sciences in Medicine Open Access 19 September 2023
-
Lower pass threshold (≥93%) for critical congenital heart disease screening at high altitude prevents repeat screening and reduces false positives
Journal of Perinatology Open Access 17 August 2022
-
Early oxygen levels contribute to brain injury in extremely preterm infants
Pediatric Research Open Access 22 March 2021
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
References
Vento M . Oxygen supplementation in the neonatal period: changing the paradigm. Neonatology 2014; 105 (4): 323–331.
De Halleux V, Truttmann A, Gagnon C, Bard H . The effect of blood transfusion on the hemoglobin oxygen dissociation curve of very early preterm infants during the first week of life. Semin Perinatol 2002; 26 (6): 411–415.
Weindling M, Paize F . Peripheral haemodynamics in newborns: best practice guidelines. Early Hum Dev 2011; 86 (3): 159–165.
Sola A, Golombek S, Bueno MT, Lemus-Varela L, Zuluaga C, Dominguez F et al. Safe oxygen saturation targeting and monitoring in preterm infants. Can we avoid hypoxia and hyperoxia?. Acta Paediatr 2014; 103 (10): 1009–1018.
Schmidt B, Whyte RK, Roberts RS . Trade-off between lower or higher oxygen saturations for extremely preterm infants: the first Benefits of Oxygen Saturation Targeting (BOOST) II Trial reports its primary outcome. J Pediatrics 2014; 165 (1): 6–8.
Carlo WA, Finer NN, Walsh MC, Rich W, Gantz MG, Laptook AR et al. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med 2010; 362 (21): 1959–1969.
Schmidt B, Whyte RK, Asztalos EV, Moddemann D, Poets C, Rabi Y et al. Effects of targeting higher vs lower arterial oxygen saturations on death or disability in extremely preterm infants: a randomized clinical trial. JAMA 2013; 309 (20): 2111–2120.
Darlow BA, Marschner SL, Donoghoe M, Battin MR, Broadbent RS, Elder MJ et al. Randomized controlled trial of oxygen saturation targets in very preterm infants: two year outcomes. J Pediatrics 2014; 165 (1): 30–35.e2.
Stenson BJ, Tarnow-Mordi WO, Darlow BA, Simens J, Zuszczak E, Askie L et al. Oxygen saturation and outcomes in preterm infants. N Engl J Med 2013; 368 (22): 2094–2104.
Drazen JM, Solomon CG, Greene MF . Informed consent and SUPPORT. N Engl J Med 2013; 368 (20): 1929–1931.
Fanaroff JM . Ethical support for surfactant, positive pressure, and oxygenation randomized trial (SUPPORT). J Pediatrics 2013; 163 (5): 1498–1499.
Lantos JD . SUPPORTing premature infants. Pediatrics 2013; 132 (6): e1661–e1663.
Wright CJ, Saugstad OD . OHRP and SUPPORT: lessons in balancing safety and improving the way we care for patients. J Pediatrics 2013; 163 (5): 1495–1497.
Pharoah PD . The US Office for Human Research Protections' judgment of the SUPPORT trial seems entirely reasonable. BMJ 2013; 347: f4637.
Thornton H . The US Office for Human Research Protections' intervention in the SUPPORT trial was indeed ill conceived. BMJ 2013; 347: f4639.
Modi N . Ethical pitfalls in neonatal comparative effectiveness trials. Neonatology 2014; 105 (4): 350–351.
US Department of Health & Human Services. Public meeting: Matters related to protection of human subjects and research considering standard of care interventions. Wednesday, 28 August 2013, Washington, DC, USA. Available from http://www.hhs.gov/ohrp/newsroom/rfc/Public%20Meeting%20August%2028,%202013/supportmeetingtranscriptfinal.html.
Chan ED, Chan MM, Chan MM . Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations. Respir Med 2013; 107 (6): 789–799.
Emond D, Lachance C, Gagnon J, Bard H . Arterial partial pressure of oxygen required to achieve 90% saturation of hemoglobin in very low birth weight newborns. Pediatrics 1993; 91 (3): 602–604.
Harris AP, Sendak MJ, Donham RT, Thomas M, Duncan D . Absorption characteristics of human fetal hemoglobin at wavelengths used in pulse oximetry. J Clin Monit 1988; 4 (3): 175–177.
Pologe JA, Raley DM . Effects of fetal hemoglobin on pulse oximetry. J Perinatol 1987; 7 (4): 324–326.
Arikan GM, Haeusler MC, Haas J, Scholz H . Does the hemoglobin concentration in fetal blood interfere with the accuracy of fetal reflection pulse oximetry?. Fetal Diagn Ther 1998; 13 (4): 236–240.
Rajadurai VS, Walker AM, Yu VY, Oates A . Effect of fetal haemoglobin on the accuracy of pulse oximetry in preterm infants. J Paediatrics Child Health 1992; 28 (1): 43–46.
Masimo Radical 7 Signal Extraction Pulse CO-OXimeter with rainbow technology—Operator's manual 2010.
Hay WW Jr., Rodden DJ, Collins SM, Melara DL, Hale KA, Fashaw LM . Reliability of conventional and new pulse oximetry in neonatal patients. J Perinatol 2002; 22 (5): 360–366.
Johnston ED, Boyle B, Juszczak E, King A, Brocklehurst P, Stenson BJ . Oxygen targeting in preterm infants using the Masimo SET Radical pulse oximeter. Arch Dis Child Fetal Neonatal Edn 2011; 96 (6): F429–F433.
Saugstad OD, Aune D . Optimal oxygenation of extremely low birth weight infants: a meta-analysis and systematic review of the oxygen saturation target studies. Neonatology 2014; 105 (1): 55–63.
Di Fiore JM, Walsh M, Wrage L, Rich W, Finer N, Carlo WA et al. Low oxygen saturation target range is associated with increased incidence of intermittent hypoxemia. J Pediatrics 2012; 161 (6): 1047–1052.
Bateman D, Polin RA . A lower oxygen-saturation target decreases retinopathy of prematurity but increases mortality in premature infants. J Pediatrics 2013; 163 (5): 1528–1529.
Guyatt GH, Briel M, Glasziou P, Bassler D, Montori VM . Problems of stopping trials early. BMJ 2012; 344: e3863.
Bassler D, Briel M, Montori VM, Lane M, Glasziou P, Zhou Q et al. Stopping randomized trials early for benefit and estimation of treatment effects: systematic review and meta-regression analysis. JAMA 2010; 303 (12): 1180–1187.
Manja V, Mathew B, Carrion V, Lakshminrusimha S . Critical congenital heart disease screening by pulse oximetry in a neonatal intensive care unit. J Perinatol 2014 (e-pub ahead of print).
Milner QJ, Mathews GR . An assessment of the accuracy of pulse oximeters. Anaesthesia 2012; 67 (4): 396–401.
O'Reilly M . Masimo signal extraction technology pulse oximetry. Concerning the article by R.J. Rosychuk et al.: Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants [Neonatology 2012;101:14-19]. Neonatology 2012; 101 (4): 239–240 author reply 240.
Rosychuk RJ, Hudson-Mason A, Eklund D, Lacaze-Masmonteil T . Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants. Neonatology 2012; 101 (1): 14–19.
Quine D, Stenson BJ . Arterial oxygen tension (Pao2) values in infants <29 weeks of gestation at currently targeted saturations. Arch Dis Child Fetal Neonatal Edn 2009; 94 (1): F51–F53.
Quine D, Stenson BJ . Does the monitoring method influence stability of oxygenation in preterm infants? A randomised crossover study of saturation versus transcutaneous monitoring. Arch Dis Child Fetal Neonatal Edn 2008; 93 (5): F347–F350.
De Halleux V, Gagnon C, Bard H . Decreasing oxygen saturation in very early preterm newborn infants after transfusion. Arch Dis Child Fetal Neonatal Edn 2003; 88 (2): F163.
Furfaro S, Prosmanne J, Bard H . Hemoglobin oxygen dissociation (P50) in bronchopulmonary dysplasia. Biol Neonate 1990; 57 (2): 72–76.
Shiao SY . Effects of fetal hemoglobin on accurate measurements of oxygen saturation in neonates. J Perinat Neonatal Nurs 2005; 19 (4): 348–361.
Polin RA, Fox WW, Abman SH . Fetal and Neonatal Physiology: Expert Consult—Online and Print 4th ednvol. 2. Elsevier Limited: Oxford, UK, 2011.
Wimberley PD . Fetal hemoglobin, 2,3-diphosphoglycerate and oxygen transport in the newborn premature infant. Scand J Clin Lab Invest Suppl 1982; 160: 1–149.
Askie LM, Henderson-Smart DJ, Irwig L, Simpson JM . Oxygen-saturation targets and outcomes in extremely preterm infants. N Engl J Med 2003; 349 (10): 959–967.
Schmidt B, Roberts RS, Whyte RK, Asztalos EV, Poets C, Rabi Y et al. Impact of study oximeter masking algorithm on titration of oxygen therapy in the Canadian Oxygen Trial. J Pediatrics 2014; 165 (4): 666–671.e2.
Alderliesten T, Lemmers PM, Smarius JJ, van de Vosse RE, Baerts W, van Bel F . Cerebral oxygenation, extraction, and autoregulation in very preterm infants who develop peri-intraventricular hemorrhage. J Pediatrics 2013; 162 (4): 698–704 e692.
Claure N, Bancalari E . Automated closed loop control of inspired oxygen concentration. Respir Care 2013; 58 (1): 151–161.
Acknowledgements
This work was supported by a grant 5 R01 HD072929 (Optimal oxygenation in neonatal lung injury) to SL.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
The authors declare no conflict of interest.
Additional information
Supplementary Information accompanies the paper on the Journal of Perinatology website
Supplementary information
Rights and permissions
About this article
Cite this article
Lakshminrusimha, S., Manja, V., Mathew, B. et al. Oxygen targeting in preterm infants: a physiological interpretation. J Perinatol 35, 8–15 (2015). https://doi.org/10.1038/jp.2014.199
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/jp.2014.199
This article is cited by
-
LED light can falsify pulse oximetry readings via the stroboscopic effect
Physical and Engineering Sciences in Medicine (2023)
-
Lower pass threshold (≥93%) for critical congenital heart disease screening at high altitude prevents repeat screening and reduces false positives
Journal of Perinatology (2022)
-
Early oxygen levels contribute to brain injury in extremely preterm infants
Pediatric Research (2021)
-
Thresholds for oximetry alarms and target range in the NICU: an observational assessment based on likely oxygen tension and maturity
BMC Pediatrics (2020)
-
Reduced rate of treated retinopathy of prematurity after implementing lower oxygen saturation targets
Journal of Perinatology (2019)