Abstract
OBJECTIVES: To document low sound levels, the range and pattern of levels, and the relative effects of operational (staff and equipment generated) and facility (building generated) noise on the acoustic environment of a level III nursery.
STUDY DESIGN: A quasi-experimental, prospective, longitudinal study of one bed space. Operational noise was reduced through staff behavior change while facility noise was reduced through renovation.
RESULTS: Initial noise levels were typical of those in the literature and in recently measured nurseries. About 80% of sound levels were between 62 and 70 dBA. The lowest levels (Lmin) were 60 to 65 dBA. After staff behavior change, Lmin was about 56 dBA although the highest levels (Lmax) remained at 78 to 100 dBA. Levels following renovation were reduced to Lmins of 47 to 51 dBA and Lmaxs of 68 to 84 dBA, perceived as three or four times quieter than initially.
CONCLUSIONS: Staff behavior as well as the acoustical characteristics of the facility determine the levels of noise and quiet in an intensive care nursery.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Philbin MK . The influence of auditory experience on the behavior of preterm newborns J Perinatol 2000 20: S68–76
Ando Y, Hattori H . Effects of noise on sleep of babies J Acoust Soc Am 1977 62: 199–204
Gädeke R, Döring B, Keller F, Vogel Å . The noise level in a children's hospital and the wake-up threshold in infants Acta Paediatr Scand 1969 58: 164–70
Murray B, Campbell D . Sleep states in the newborn: influence of sound Neuropaediatrie 1971 2: 335–42
Strauch C, Brandt S, Edwards-Beckett J . Implementation of a quiet hour: effect on noise levels and infant sleep states Neonatal Network 1993 12: 31–5
Keefe MR . Comparison of neonatal nighttime sleep–wake patterns in nursery versus rooming-in environments Nurs Res 1987 36: 140–4
Morris BH, Philbin MK, Bose C . Physiological effects of sound on the newborn J Perinatol 2000 20: S55–60
Philbin MK, Taber KH, Hayman LA . Preliminary report: changes in vital signs of term newborns during MR Am J Neuroradiol 1996 17: 1033–6
Philbin MK, Robertson A, Hall JW III . Recommended permissible noise criteria for occupied, newly constructed or renovated hospital nurseries J Perinatol 1999 19: 559–63
Anderssen SH, Nicolaisen RB, Gabrielsen GW . Autonomic response to auditory stimulation Acta Paediatr 1993 82: 913–8
Long JG, Lucey JF, Philip AGS . Noise and hypoxemia in the intensive care nursery Pediatrics 1980 65: 143–5
Steinschnneider A . Sound intensity and respiratory responses in the neonate. Comparison with cardiac rate responses Psychosomat Med 1968 30: 534–41
Gray L, Philbin MK . Measuring sound in hospital nurseries J Perinatol 2000 20: S100–4
Gray L . Properties of sound J Perinatol 2000 20: S21–30
Harris CM . Handbook of Acoustical Measurements and Noise Control New York: Acoustical Society of America 1998 p 20–44
Hirschorn M . Noise Control Reference Handbook Bronx, NY: Industrial Acoustics Company 1989 p B1–4 C1–10, F1–22
Cole JG, Begish-Duddy A, Judas ML, Jorgensen KM . Changing the NICU environment: the Boston City Hospital model Neonatal Network 1990 9: 15–23
Evans J, Philbin MK . Facility and operations planning for quiet hospital nurseries J Perinatol 2000 20: S105–12
Beranek L . Acoustical Measurements New York: American Institute of Physics 1988 p 513
Moore BCJ . Loudness, adaptation, and fatigue In: Moore BCJ, editor Introduction to the Psychology of Hearing 2nd ed New York: Academic Press 1982 p 48–9
Als H, Duffy FH, McAnulty GB . Behavioral differences between preterm and full term newborns as measured with the APIB system scores: I Infant Behav Dev 1988 11: 305–18
Als H, Duffy FH, McAnulty GB . The APIB, an assessment of functional competence in preterm and full-term newborns regardless of gestational age at birth: II Infant Behav Dev 1988 11: 319–31
Acknowledgements
The authors thank Bassel Choucair, Oswaldo Gaytan, MD, PhD, and Steven Philip for their help with data collection and graphics, the administration and nursery staff of Memorial Hermann Children's Hospital for financial support and all-important human effort, the Division of Neonatology of the University of Texas — Houston Medical School for its sustained intellectual and administrative support, and Jack B. Evans, P.E. for suggestions regarding technical aspects of the manuscript. The work was performed in the Otolaryngology Laboratory of the University of Texas — Houston Medical School.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Philbin, M., Gray, L. Changing Levels of Quiet in an Intensive Care Nursery. J Perinatol 22, 455–460 (2002). https://doi.org/10.1038/sj.jp.7210756
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jp.7210756
This article is cited by
-
Neonatal intensive care unit incubators reduce language and noise levels more than the womb
Journal of Perinatology (2020)
-
Noise pollution level in a pediatric hospital
International Journal of Environmental Science and Technology (2019)
-
The Effect of Listening to Holy Quran Recitation on Weaning Patients Receiving Mechanical Ventilation in the Intensive Care Unit: A Pilot Study
Journal of Religion and Health (2019)
-
Is Less Noise, Light and Parental/Caregiver Stress in the Neonatal Intensive Care Unit Better for Neonates?
Indian Pediatrics (2018)
-
The influence of APACHE II score on the average noise level in an intensive care unit: an observational study
BMC Anesthesiology (2015)