Abstract
Developing safe and effective nanoparticles for the delivery of messenger RNA (mRNA) is slow and expensive, partly due to the lack of predictive power of in vitro screening methods and the low-throughput nature of in vivo screening. While DNA barcoding and batch analysis present methods for increasing in vivo screening throughput, they can also result in incomplete or misleading measures of efficacy. Here, we describe a high-throughput and accurate method for the screening of pooled nanoparticle formulations within the same animal. The method uses liquid chromatography with tandem mass spectrometry to detect peptide barcodes translated from mRNAs in nanoparticle-transfected cells. We show the method’s applicability by evaluating a library of over 400 nanoparticle formulations with 384 unique ionizable lipids using only nine mice to optimize the formulation of a biodegradable lipid nanoparticle for mRNA delivery to the liver. Barcoding lipid nanoparticles with peptide-encoding mRNAs may facilitate the rapid development of nanoparticles for mRNA delivery to specific cells and tissues.
Similar content being viewed by others
Main
RNA therapeutics hold immense potential for the treatment of a wide variety of diseases by directly controlling protein production within specific cells in the body1,2,3,4,5. In particular, non-viral delivery of mRNA using lipid nanoparticles (LNPs) is an attractive method for the delivery of therapeutic proteins due to the transient nature of expression from mRNA and the potential for repeat dosing of synthetic nanoparticles (NPs)2,3,4. Furthermore, mRNA LNPs have already been applied in preclinical models for protein replacement therapy6, vaccination7,8 and gene editing9,10,11,12, as well as for the prevention of COVID-19 (refs. 13,14).
Despite this progress, there continues to be a need for safe, specific and efficacious delivery vehicles. One challenge to delivery lipid development is the poor capability of in vitro studies to predict in vivo biodistribution and efficacy, as well as the low-throughput nature of traditional in vivo studies15,16. While these issues have been partly addressed by the application of methods such as batch analysis8 and DNA and/or RNA barcoding17,18, these methods each have their own shortcomings that limit their use as screening approaches in preclinical studies. For example, the extent to which batch analysis can reduce the number of animals required for library screening depends on the composition of the library itself; in cases where a large fraction of a library consists of similarly performing LNPs, batch analysis can require a comparable number of animals to single LNP analysis. Furthermore, while DNA and/or RNA barcoding can provide a wealth of information regarding the separate biodistributions of dozens of NPs within the same animal, previous studies have shown that trafficking of LNPs to a specific tissue does not necessarily lead to expression within that tissue and that, often, tissues that have very low accumulation of a certain LNP will have functional delivery at a much higher rate than tissues with substantially higher accumulation19,20.
Recently, a method for in vivo screening of NPs for functional mRNA delivery using LNPs coformulated with Cre mRNA and DNA barcodes in conjunction with the transgenic Ai14 mouse, termed ‘FIND’, has been reported21. Briefly, in this system, successfully transfected cells will constitutively express tdTomato, and DNA barcodes that are colocalized with tdTomato signal can be quantified as an indirect measure of the extent of functional delivery21,22. While this presents a significant improvement over the original DNA barcoding assay, it still has several important limitations. For example, NPs that are internalized or retained on the surface of a target cell will result in positive hits in a FIND screen as long as the target cell is successfully transfected by a single NP type (Fig. 1a). This may lead to misleading results, especially given that studies have shown uptake of multiple NPs per cell across multiple endosomes23,24. To avoid this ‘bystander’ effect, an ideal multiplexed assay for functional delivery would instead directly measure the amount of protein production effected by each NP. In addition, LNPs containing mRNA barcodes and DNA barcodes have been shown to result in significantly different biodistributions, which may lead to additional bias18. Finally, FIND is dependent on the use of the transgenic Ai14 mouse model, precluding its use as a screening system in larger animal models and in specific disease models for which Cre-Lox reporter systems are not available.
Here, we have developed a peptide barcode-based screening system that allows for the simultaneous evaluation of multiple LNPs within the same animal by packaging a different peptide barcode encoding mRNA into each distinct type of LNP. Barcoded LNPs can then be pooled and administered in a single dose to the same animal and, once translation of successfully delivered mRNA has occurred in a target tissue or cell type, expression of each peptide barcode sequence can be quantified using liquid chromatography followed by tandem mass spectrometry (LC–MS/MS). Thus, each unique LNP formulation yields its own distinct measurement that is a direct quantification of protein production effected by it within the analysed tissue or cell type. Because this method does not rely on the presence of any reporter transgene, it is inherently model independent and theoretically may be used in any preclinical model. In this study we show that, by applying MS/MS, we are able to detect and quantify the expression of peptide barcodes from up to 65 distinct mRNA LNPs in both in vitro and in vivo models accurately and within a wide dynamic range. We then apply this system to screen a library of 384 ionizable lipids over more than 400 different LNPs for their ability to effect hepatic protein production and, as a result, develop a new biodegradable LNP, RM133-3-21, for potent functional mRNA delivery in vivo.
Results
We reasoned that an ideal screening system for functional mRNA delivery would be model independent so that it could be applied in any preclinical model of disease, would consist of multiple measures of protein production that are each orthogonal to any others such that multiple formulations could be tested within the same assay and would be highly sensitive and quantitative over a wide dynamic range. The simplest approach to having an orthogonal functional output for each NP within a pool would be to have each NP effect production of a unique protein. The target tissues or cell populations could then be collected and lysed, and each expressed protein could be detected and its expression level measured using LC–MS/MS, which is a selective and sensitive method for protein detection and quantification (Fig. 1b). Since the only prerequisite for this assay is that the targeted cell type be able to translate functional protein from exogenously delivered mRNA, the proposed method would inherently be model independent. Thus, the assay as described would meet all three of our design criteria for an ideal screening system for functional delivery.
To that end, we developed an assay in which NPs are formulated with unique peptide barcode encoding mRNAs, which, when functionally delivered to the cytoplasm of target cells, express a protein fused with a peptide barcode sequence that can be detected and quantified through LC–MS/MS and a short epitope tag for quantification of expression using enzyme-linked immunosorbent assay. To reduce background noise from non-barcoded proteins present within target cells, we used a monomeric variant of streptavidin (monomeric streptavidin, mSA)25,26, which can easily be enriched from crude lysates using a biotinylated scaffold, as the carrier protein for each peptide barcode (Fig. 1c). After barcode-tagged mSA is immobilized on biotinylated beads, the C-terminal end of the carrier protein is cleaved by tobacco etch virus (TEV) protease, releasing the peptide barcode into solution. Finally, the resulting peptide barcode mixture is separated from the biotinylated beads through filtration and run on LC–MS/MS to quantify the relative amounts of each peptide present in solution.
As an initial proof of concept, we wanted to determine whether this approach could be used to accurately measure functional delivery to cells cultured in vitro. To that end, we prepared a set of 24 mRNAs that, upon functional delivery to the cytosol of target cells, would be translated into functional carrier proteins tagged with unique peptide barcode sequences (Supplementary Table 1). To determine whether this assay would enable simultaneous quantification of functional delivery of each mRNA, we created two pools (F2 and F3) that were each composed of the same 24 peptide barcode mRNAs but in different relative amounts and used them to transfect human embryonic kidney 293T (HEK293T) cells (Fig. 2a). F2 was constructed by adding each peptide barcode mRNA (except bc28 and bc32, which were each added at the median dose) at a different dose ranging from 13.6 ng to 1.95 µg; F3 was constructed by forming six groups each consisting of four peptide barcode mRNAs, with the mRNAs of each group added at a relative dose four times lower than that of the previous group, such that the dynamic range covered (2.42 ng to 2.48 µg) was roughly three orders of magnitude (Supplementary Table 1). To account for natural variations in measured peptide abundance due to different extents to which peptides ionize and fragment, as well as any differences in translation efficiencies between mRNAs, we transfected a separate set of cells with an additional pool composed of each mRNA in an equal amount (equal delivery reference). By normalizing the MS2 intensity of each peptide with respect to its intensity in the equal delivery reference, we are able to obtain a relative peptide abundance with respect to the other peptides within the pool. In general, we observed a very strong correlation (R2 = 0.951 and R2 = 0.991 for pools F2 and F3, respectively) between the normalized abundance of each peptide barcode measured via LC–MS/MS to the dose of the corresponding mRNA (Fig. 2b).
Encouraged by these results, we performed a similar proof of concept experiment in vivo, using previously described cKK-e12 LNPs27 to deliver an mRNA pool composed of paired peptide barcode mRNAs at doses linearly spaced from 0.001 to 0.1 mg kg−1 (Fig. 2a and Supplementary Table 2). We again found that, when normalized to an equal delivery reference, the measured peptide abundances align closely (R2 = 0.929) with the administered doses of the corresponding peptide barcode mRNAs (Fig. 2b). Altogether, the results from these proof of concept experiments demonstrate that the peptide barcoding assay can accurately measure the amount of protein translated from multiple mRNAs within a single biological sample.
We then sought to optimize and expand the peptide barcode mRNA library to increase the screening throughput of the system. Our previous proof of concept experiments were performed using HA-tagged barcode sequences; since this tag comprises over half of the amino acid sequence of each barcode, we reasoned that varying the epitope tag could substantially affect sensitivity and quantification using the assay. Thus, we explored the effect of using four different epitope tags (HA, c-myc, FLAG and 6xHis) on measured peptide abundance. As expected, the choice of epitope tag had a significant impact on peptide abundance, with myc-tagged barcodes having more than an order of magnitude increase in their measured precursor ion intensity relative to those that were HA-tagged; conversely, FLAG-tagged and His-tagged barcodes were either undetected or resulted in intensities that were several orders of magnitude lower than their HA-tagged and myc-tagged counterparts (Supplementary Fig. 1).
To increase throughput of the assay, we generated a library of transcription templates encoding 114 unique myc-tagged peptide barcode mRNAs (Supplementary Table 3). These were then combined in equal amounts and subsequently transcribed to produce a single pool of peptide barcode mRNAs; this pool was then delivered in vivo to the mouse liver using cKK-e12 LNPs, and the resulting peptide barcode mixture was analysed using LC–MS/MS to identify a subset of suitable barcode sequences (Fig. 2c). Of the 114 unique barcode sequences, we identified a set of 65 peptides with high peptide dot products in liver lysates from treated mice, low dot products in PBS injected liver lysates, high signal to noise ratio (measured as the ratio of peptide abundance in treated liver lysates to abundance in untreated liver lysates) and some degree of separation in either precursor mass or retention time from other peptides in the library (Fig. 2d and Supplementary Table 3). We then performed an in vivo validation experiment in the mouse liver using either multiple reaction monitoring (MRM) or data-independent acquisition (DIA) for quantification of peptide abundance and observed excellent correlations between mRNA dose and measured precursor ion intensity, with slightly better quantification using DIA (R2 = 0.944) than MRM (R2 = 0.825) (Fig. 2e and Supplementary Fig. 2). In vitro validation experiments in HEK293T cells yielded similar results, indicating that the expanded library of 65 peptide barcodes can be used to accurately and simultaneously measure functional delivery rates both in vitro and in vivo (Supplementary Fig. 3). We note that only a weak correlation was observed between MS1 intensities of peptides expressed from the equal delivery controls in cultured HEK293T cells and mouse liver lysates (R2 = 0.412), which may be due to differences in translation efficiency in the two contexts, as well as differences in peptide extraction efficiencies from the two matrices (Supplementary Fig. 4).
We then sought to demonstrate that peptide barcoding can be used to develop and optimize LNP formulations. To that end, we synthesized a library of 384 unique ionizable lipids, all featuring the same general branched tail structure containing several biodegradable ester linkages, using the combinatorial reaction and components shown in Fig. 3. We then screened this library for mRNA delivery efficacy by formulating each ionizable lipid into a separate LNP with 1,2-dioleoyl-sn-glycero-3-phosphoethanolamine (DOPE), cholesterol and C14-PEG2000, and assaying for hepatic protein production effected by each LNP. Using the peptide barcoding assay, this entire library was screened using only eight mice (48 unique LNPs per mouse, not including replicates). To avoid potential false positives from background peptides that may be mistaken for barcodes, we set a minimum peptide dot product cut-off of 0.8. Of the 384 LNPs evaluated, 43 resulted in peptide dot products greater than the cut-off, with most (37 out of 43) being derived from either timnodonic acid (133-) or docosahexaenoic acid (137-) (Fig. 4a). We then validated the top four hits identified in the peptide barcoding analysis using the firefly luciferase (FLuc) assay and found that all four LNPs resulted in high levels of FLuc protein production in the liver when evaluated individually (Fig. 4b).
Next, we explored whether we could further improve performance of the lead compound, RM133-3, by optimizing its formulation. Several previous ionizable lipid screens have been performed using either a constant 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC)28,29 or DOPE20,30 formulation; in addition, a systematic study of the factors important for LNP efficacy found that phospholipid identity and ionizable lipid to weight ratio were the most significant predictors of LNP performance27. Thus, we chose to vary the phospholipid identity (DOPE versus DSPC) and the ionizable lipid to mRNA weight ratio (10, 15 and 20), as well as the molar ratios of lipid components in the formulation, which we varied linearly between the constant DSPC and DOPE formulations previously mentioned (Fig. 5a and Supplementary Table 4). Using a full factorial design of these variables, we generated a library of 24 unique peptide-barcoded LNPs with RM133-3 as the ionizable lipid and administered these to the same mouse. From this library, we identified three formulations that performed at a significantly higher level than the original RM133-3 formulation (Fig. 5b). In accordance with previous findings27,31, we found that formulations containing DOPE significantly outperformed those that contained DSPC (Extended Data Fig. 1). To verify that the barcoding analysis can be used to quantitatively assess individual LNP performance in a pooled setting, we compared the top three performing LNPs (RM133-3-20, RM133-3-14 and RM133-3-21) as well as the worst performing LNP (RM133-3-04) to the original formulation (RM133-3-01) using the human erythropoietin (hEPO) assay (Fig. 5c). While the ranking of the top three LNPs identified in the peptide barcoding analysis was not preserved in the results of the hEPO assay, we found that all three top performers did, in fact, outperform the original formulation; in addition, the worst performing LNP in the barcoding analysis resulted in lower protein production than any other formulation tested. Finally, the top-performing LNP, RM133-3-21, was found using the FLuc assay to be roughly 4.5 times more potent than DLin-MC3-DMA, which is a benchmark ionizable lipid currently used in the clinic (Fig. 5d).
Discussion
Over the years, it has become increasingly clear that in vitro screening methods are, in many cases, ill-suited for predicting the in vivo behaviour of nucleic acid delivery vehicles15,16, highlighting the need for increasing the throughput of in vivo testing. To address this, we have developed an LC–MS/MS based assay for directly measuring the functional delivery of mRNA in vivo by multiple NP carriers within the same animal. By barcoding each NP with an mRNA that encodes a distinct peptide tag, we are able to directly measure the protein production from up to 65 different NPs simultaneously within the same model, making it an ideal assay for applications such as protein replacement therapy and mRNA vaccination, where maximal protein production is desirable. By contrast, other barcoding methods rely on the measurement of DNA or RNA barcodes that have been delivered to the desired cells or tissues17,18; while these methods can be significantly improved by selecting only cells that have successfully been transfected21, they all rely on the assumption that the level of distribution of a NP to target cells is directly related to the level of protein production effected by that NP.
Although peptide barcoding of NPs presents a promising method for the development and optimization of mRNA delivery vehicles, it does have a few important limitations. First, while peptide barcoding will be useful for screening NPs for their capacity to deliver mRNA and can easily be adapted for plasmid delivery, it cannot be used to screen for the functional delivery of payloads that result in knockdown of a target protein. For these applications, DNA barcoding methods for indirectly measuring the level of protein knockdown effected by pooled NPs may be useful32,33. Second, multiple studies have now demonstrated that there can be non-linear effects associated with mixing different ionizable lipid species34,35. Indeed, in a pilot screen of the combinatorial library explored in this study, we observed some degree of non-linearity that resulted in a significantly higher measurement of protein production using our pooled barcoding analysis than with a traditional single NP analysis (Extended Data Fig. 2a–c). We further demonstrated that this non-linearity is inherent to NP pooling in general and is not specific to peptide barcoding (Extended Data Fig. 2d). We speculate that this may be the cause of discrepancies in Fig. 5, where the rank ordering of LNP efficacies in the hEPO and peptide barcoding assays differed, which further highlights the need for secondary validation assays following any pooled NP analysis. While further studies are required to determine the exact cause of this non-linearity and how to predict its occurrence, we speculate that it may be related to the level of chemical diversity, particularly within the lipid tails, present within a given NP pool.
A major advantage of DNA and RNA barcoding is the presence of an inherent signal amplification step, which affords a high level of sensitivity. While we have shown that peptide barcoding is also sensitive and can be used to detect and quantify hepatic protein expression at doses as low as 0.001 mg kg−1, further studies will need to be performed to determine whether this method can be used for NP development in applications where protein production may be several orders of magnitude lower. For example, we observed in initial experiments measuring splenic expression of peptide barcodes that, while expressed peptide barcodes can be detected in whole spleen lysates, quantification is much less reliable than in liver lysates (Supplementary Fig. 5). This suggests that further improvements to our assay should be explored to expand peptide barcoding to more challenging applications, particularly those in which the desired levels of protein expression are significantly lower than in the liver.
In this study, we have demonstrated a proof of concept for using peptide barcoding as a screening tool for mRNA delivery vehicles. However, there are several areas for further exploration that could potentially improve the sensitivity, accuracy and throughput of this assay. Although several affinity tag sequences were screened as part of this study, we note that due to its length relative to the entire peptide barcode, it is likely that further engineering of this affinity tag sequence, as well as its length, will result in better sensitivity and more accurate quantification. In addition, use of more recent proteomics methods may further improve the sensitivity and accuracy of peptide barcode quantification. While we have generated a library of 65 peptide barcodes, we anticipate that the throughput of this assay can be improved significantly by systematically screening larger peptide barcode libraries as we have done in Fig. 2. We note that incorporation of additional steps in this screening approach, such as cell-free translation to address potential variability in translation efficiency between different peptide sequences and evaluation of peptide barcodes in different tissue lysates, would likely result in a more streamlined process and ultimately a more robust assay. Furthermore, RNA sequencing can be performed in parallel to peptide barcoding to evaluate both protein expression in and biodistribution to target tissues. Last, the translation efficiency of exogenously delivered mRNA is expected to vary between different cell types. While this study has primarily been focused on the delivery of mRNA to the liver, which is predominantly composed of hepatocytes, tissues with more heterogeneous cell populations may require fractionation before analysis to ensure measurement of delivery to the correct cell type.
As a proof of concept, we have demonstrated that peptide barcoding can be used to quickly and efficiently screen a large library of NPs for their ability to effect protein production in vivo. To summarize, we have screened 384 new ionizable lipids spanning more than 400 distinct NP formulations using only a small fraction of the animals that would have been required using traditional FLuc or hEPO assays. Through this process, we have demonstrated that peptide barcoding can be used for both discovery of ionizable lipids for mRNA delivery and formulation screening for a more fine-tuned optimization of existing ionizable lipids. As a result, we have developed RM133-3-21, which is an LNP that performs at a level 4.5 times that of the benchmark lipid, DLin-MC3-DMA, while incorporating multiple ester linkages that are likely to improve its pharmacokinetics. Whereas here we have demonstrated the use of peptide barcoding for hepatic protein production, we expect that this method can readily be applied to screening for functional delivery to other tissues that have historically been more difficult to target using LNPs. As such, we anticipate that peptide barcoding of LNPs will greatly facilitate the rapid development of improved NPs for mRNA delivery to the liver, as well as to non-hepatic targets.
Methods
Plasmid and mRNA synthesis
Plasmids containing a T7 promoter upstream of a mSA coding sequence (CDS) with a C-terminal peptide barcode were used as templates for mRNA in vitro transcription (IVT). In short, a cassette containing the mSA CDS separated from an affinity tag by two BsaI cut sites was cloned into the pUC19 vector to generate an IVT template cloning vector. Individual templates were then generated by cloning in annealed DNA oligonucleotides corresponding to the desired variable barcode sequences. For the peptide barcode screen of Fig. 2c, a DNA oligonucleotide containing several degenerate bases flanked by two BsaI sites was amplified, and the resulting degenerate double-stranded DNA fragment was cloned into the generic IVT cloning vector using Golden Gate assembly. The degenerate oligonucleotide was designed to exclude certain amino acids, such as cysteine and methionine, to prevent any by-products that could reduce assay sensitivity. IVT templates were linearized using EcoRI, and mRNA was transcribed using the HiScribe T7 High Yield RNA Synthesis Kit (New England Biolabs). Capping was performed cotranscriptionally using CleanCap Reagent AG (TriLink Biotechnologies). Tailing was done enzymatically posttranscription using Escherichia coli Poly(A) Polymerase (New England Biolabs). The resulting capped and tailed mRNA was then purified using the Monarch RNA Cleanup Kit (New England Biolabs).
Ionizable lipid synthesis
Details on the synthesis and characterization of the ionizable lipid library of Fig. 3 are provided in the Supplementary Information.
LNP formulation
LNPs were formulated as previously described27. In short, a lipid solution consisting of an ionizable lipid, a phospholipid (either DOPE (Avanti Polar Lipids) or DSPC (Avanti Polar Lipids)), cholesterol (Sigma) and 14:0 PEG2000 PE (Avanti Polar Lipids) was prepared in ethanol. For benchmarking of RM133-3-21, DLin-MC3-DMA was purchased from Organix. The molar composition used was 35:16:46.5:2.5 unless otherwise noted. The lipid solution was mixed by flowing through a microfluidic channel36 with an aqueous mRNA solution containing 10 mM citrate buffer (pH 3) at a 1:3 organic to aqueous volume ratio. The resulting LNPs were then dialysed against PBS (pH 7.4) for 2 h at 4 °C with a buffer to sample volume ratio greater than 1,000. For all pooled analyses, LNPs were dialysed separately against PBS and pooled before dosing.
LNP characterization
The z-average diameter and polydispersity index (PDI) of LNPs were measured using dynamic light scattering (Zetasizer Nano ZS (Malvern Panalytical), DynaPro Plate Reader (Wyatt Technology)). Total mRNA content and encapsulation efficiency were determined by performing a modified Ribogreen (ThermoFisher) assay, as previously described37.
Cell culture and transfections
HEK293T cells were cultured at 37 °C and 5% CO2 in high glucose Dulbecco’s Modified Eagle Medium with GlutaMAX supplement (ThermoFisher) containing 10% fetal bovine serum and 1% penicillin-streptomycin. For in vitro transfections, 3 × 106 cells were plated without antibiotics in a T75 flask and allowed to adhere and grow for a period of 24 h, after which Lipofectamine RNAiMAX (ThermoFisher) lipoplexes containing 13.2 µg of a pool of peptide barcode mRNAs were added to each flask. Whole cell lysate was collected 24 h posttransfection and processed as described below.
Animal experiments
Animal experiments for this study were approved by the Massachusetts Institute of Technology Institutional Animal Care and Use Committee and were consistent with local, state and federal regulations as applicable. LNPs were administered to female 6–8-week-old C57BL/6 mice (Charles River laboratories) intravenously via the tail vein. For barcoding experiments, livers were collected and snap-frozen in liquid nitrogen 6 h postinjection and processed as described below. For hEPO experiments, blood was collected via tail-vein nicking into a clotting activator lined Microvette 100 Z tube (Sarstedt) 6 h postinjection. For FLuc experiments, whole organs were resected from mice at the indicated time point postinjection and imaged using an IVIS imaging system (PerkinElmer). Mice were euthanized through carbon dioxide asphyxiation.
Extraction of peptide barcodes from lysate
Cultured cells were collected 24 h posttransfection and lysed using RIPA lysis and extraction buffer (ThermoFisher) to obtain whole cell lysates. Snap-frozen livers were thawed on ice, and 150 mg of each were weighed out into 2 ml of soft tissue homogenizing CK14 tubes (Bertin). Then, 1.5 ml of Triton X-100 lysis buffer (150 mM NaCl, 1.0% Triton X-100, 50 mM Tris) were added to each tube, and livers were homogenized using a Precellys 24 tissue homogenizer (Bertin) to obtain liver lysates. All lysis buffers were supplemented with protease inhibitors by diluting Protease Inhibitor Cocktail (100×) (Cell Signaling Technology) to 1× in the appropriate lysis buffer. Cell and liver lysates were then precleared with 100 µl of G-Sep Agarose CL-6B beads (G-Biosciences) for 1 h and subsequently incubated with 100 µl of Immobilized Biotin Resin (G-Biosciences) for 3 h at room temperature. Beads containing the immobilized protein were then washed and resuspended in a 50 µl solution containing TEV protease (New England Biolabs) and incubated overnight at 4 °C. The resulting bead solution was then filtered using 0.65 µm Ultrafree-MC centrifugal filters (Millipore Sigma) and the filtrate was run on LC–MS/MS.
LC–MS/MS for peptide barcode analysis
Here, 1 μl of the peptide sample was loaded with an autosampler directly onto a 50 cm EASY-Spray C18 column (Thermo Scientific). Peptides were eluted from the column using a Dionex Ultimate 3000 Nano LC system with a 5 min gradient from 1% buffer B to 7% buffer B (100% acetonitrile, 0.1% formic acid), followed by a 29.8 min gradient to 25% and a 10.2 min gradient to 36% B, followed by a 0.5 min gradient to 80% B and held constant for 4.5 min. Finally, the gradient was changed from 80% buffer B to 99% buffer A (100% water, 0.1% formic acid) over 0.1 min and then held constant at 99% buffer A for another 19.9 min. The application of a 2.2 kV distal voltage electrosprayed the eluting peptides directly into the Thermo Exploris480 mass spectrometer equipped with an EASY-Spray source (Thermo Scientific). Mass spectrometer-scanning functions and high-performance liquid chromatography gradients were controlled by the Xcalibur data system (Thermo Scientific). MS1 scan parameters were 60,000 resolution, scan range m/z 375–1,600, AGC at 300%, injection time (IT) at 50 ms. DIA scans were 33 2-Da windows from m/z 605–672 with 0.5 Da overlap and parameters of 15,000 resolution, HCD collision energy at 28%, AGC target at 200% and IT set to auto.
Statistics
All statistical analyses were performed using an unpaired, two-tailed Student’s t-test (when comparing only two groups) or a one-way analysis of variance (ANOVA) with Dunnett’s correction (when comparing three or more groups) in Graphpad Prism 9. In all figures, statistical significance is denoted by asterisks when P < 0.001, where *, **, *** and **** denote P < 0.05, P < 0.01, P < 0.001 and P < 0.0001, respectively.
Reporting summary
Further information on research design is available in the Nature Portfolio Reporting Summary linked to this article.
Data availability
The main data supporting the results in this study are available within the paper and its Supplementary Information. All data generated or analysed during the study are available from the corresponding author on reasonable request.
References
Yin, H. et al. Non-viral vectors for gene-based therapy. Nat Rev. Genet. 15, 541–555 (2014).
Kauffman, K. J., Webber, M. J. & Anderson, D. G. Materials for non-viral intracellular delivery of messenger RNA therapeutics. J. Control. Release 240, 227–234 (2016).
Li, B., Zhang, X. & Dong, Y. Nanoscale platforms for messenger RNA delivery. Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol. 11, e1530 (2019).
Kowalski, P. S., Rudra, A., Miao, L. & Anderson, D. G. Delivering the messenger: advances in technologies for therapeutic mRNA delivery. Mol. Ther. 27, 710–728 (2019).
Rhym, L. H. & Anderson, D. G. Nanoscale delivery platforms for RNA therapeutics: challenges and the current state of the art. Med 3, 167–187 (2022).
DeRosa, F. et al. Therapeutic efficacy in a hemophilia B model using a biosynthetic mRNA liver depot system. Gene Ther. 23, 699–707 (2016).
Pardi, N. et al. Zika virus protection by a single low-dose nucleoside-modified mRNA vaccination. Nature 543, 248–251 (2017).
Miao, L. et al. Delivery of mRNA vaccines with heterocyclic lipids increases anti-tumor efficacy by STING-mediated immune cell activation. Nat. Biotechnol. 37, 1174–1185 (2019).
Yin, H. et al. Therapeutic genome editing by combined viral and non-viral delivery of CRISPR system components in vivo. Nat. Biotechnol. 34, 328–333 (2016).
Miller, J. B. et al. Non-Viral CRISPR/Cas gene editing in vitro and in vivo enabled by synthetic nanoparticle co-delivery of Cas9 mRNA and sgRNA. Angew. Chem. Int. Ed. https://doi.org/10.1002/anie.201610209 (2017).
Yin, H. et al. Structure-guided chemical modification of guide RNA enables potent non-viral in vivo genome editing. Nat. Biotechnol. 35, 1179–1187 (2017).
Finn, J. D. et al. A single administration of CRISPR/Cas9 lipid nanoparticles achieves robust and persistent in vivo genome editing. Cell Rep. 22, 2227–2235 (2018).
Polack, F. P. et al. Safety and efficacy of the BNT162b2 mRNA Covid-19 vaccine. N. Engl. J. Med. 383, 2603–2615 (2020).
Baden, L. R. et al. Efficacy and safety of the mRNA-1273 SARS-CoV-2 vaccine. N. Engl. J. Med. 384, 403–416 (2021).
Whitehead, K. A. et al. In vitro - in vivo translation of lipid nanoparticles for hepatocellular siRNA delivery. ACS Nano 6, 6922–6929 (2012).
Paunovska, K. et al. A direct comparison of in vitro and in vivo nucleic acid delivery mediated by hundreds of nanoparticles reveals a weak correlation. Nano Lett. 18, 2148–2157 (2018).
Dahlman, J. E. et al. Barcoded nanoparticles for high throughput in vivo discovery of targeted therapeutics. Proc. Natl Acad. Sci. USA 114, 2060–2065 (2017).
Guimaraes, P. P. et al. Ionizable lipid nanoparticles encapsulating barcoded mRNA for accelerated in vivo delivery screening. J. Control. Release 316, 404–417 (2019).
Fenton, O. S. et al. Synthesis and biological evaluation of ionizable lipid materials for the in vivo delivery of messenger RNA to B lymphocytes. Adv. Mater. 29, 1606944 (2017).
Fenton, O. S. et al. Customizable lipid nanoparticle materials for the delivery of siRNAs and mRNAs. Angew. Chem. Int. Ed. 57, 13582–13586 (2018).
Sago, C. D. et al. High-throughput in vivo screen of functional mRNA delivery identifies nanoparticles for endothelial cell gene editing. Proc. Natl Acad. Sci. USA 115, E9944–E9952 (2018).
Kauffman, K. J. et al. Rapid, single-cell analysis and discovery of vectored mRNA transfection in vivo with a loxP-flanked tdTomato reporter mouse. Mol. Ther. Nucl. Acids 10, 55–63 (2018).
Gilleron, J. et al. Image-based analysis of lipid nanoparticle-mediated siRNA delivery, intracellular trafficking and endosomal escape. Nat. Biotechnol. 31, 638–646 (2013).
Vermeulen, L. M. P. et al. Endosomal size and membrane leakiness influence proton sponge-based rupture of endosomal vesicles. ACS Nano 12, 2332–2345 (2018).
Demonte, D., Drake, E. J., Lim, K. H., Gulick, A. M. & Park, S. Structure-based engineering of streptavidin monomer with a reduced biotin dissociation rate. Proteins 81, 1621–1633 (2013).
Lim, K. H., Huang, H., Pralle, A. & Park, S. Stable, high-affinity streptavidin monomer for protein labeling and monovalent biotin detection. Biotechnol. Bioeng. 110, 57–67 (2013).
Kauffman, K. J. et al. Optimization of lipid nanoparticle formulations for mRNA delivery in vivo with fractional factorial and definitive screening designs. Nano Lett. 15, 7300–7306 (2015).
Hassett, K. J. et al. Optimization of lipid nanoparticles for Intramuscular administration of mRNA vaccines. Mol. Ther. Nucleic Acids 15, 1–11 (2019).
Sabnis, S. et al. A novel amino lipid series for mRNA delivery: improved endosomal escape and sustained pharmacology and safety in non-human primates. Mol. Ther. 26, 1509–1519 (2018).
Hajj, K. A. et al. Branched-tail lipid nanoparticles potently deliver mRNA in vivo due to enhanced ionization at endosomal pH. Small 15, e1805097 (2019).
Rui, Z. et al. Helper lipid structure influences protein adsorption and delivery of lipid nanoparticles to spleen and liver. Biomater. Sci. 9, 1449–1463 (2021).
Lokugamage, M. P., Sago, C. D., Gan, Z., Krupczak, B. R. & Dahlman, J. E. Constrained nanoparticles deliver siRNA and sgRNA to T cells in vivo without targeting ligands. Adv. Mater. 31, 1902251 (2019).
Sago, C. D. et al. Nanoparticles that deliver RNA to bone marrow identified by in vivo directed evolution. J. Am. Chem. Soc. 140, 17095–17105 (2018).
Miao, L. et al. Synergistic lipid compositions for albumin receptor mediated delivery of mRNA to the liver. Nat. Commun. 11, 2424 (2020).
Cheng, Q. et al. Selective organ targeting (SORT) nanoparticles for tissue-specific mRNA delivery and CRISPR-Cas gene editing. Nat. Nanotechnol. 15, 313–320 (2020).
Chen, D. et al. Rapid discovery of potent siRNA-containing lipid nanoparticles enabled by controlled microfluidic formulation. J. Am. Chem. Soc. 134, 6948–6951 (2012).
Heyes, J., Palmer, L., Bremner, K. & MacLachlan, I. Cationic lipid saturation influences intracellular delivery of encapsulated nucleic acids. J. Control. Release 107, 276–287 (2005).
Acknowledgements
We acknowledge project funding from Translate Bio (Lexington, MA, USA) and the Marble Center for Cancer Nanomedicine, as well as support from the Cancer Center Support (core) (grant no. P30-CA14051) from the National Cancer Institute. We thank the Koch Institute Swanson Biotechnology Center for technical support, specifically the Biopolymers & Proteomics core and Preclinical Imaging and Testing core.
Author information
Authors and Affiliations
Contributions
L.H.R. developed the peptide barcoding concept. L.H.R., R.S.M. and D.G.A. conceived the study and designed experiments. L.H.R. and G.S. performed all in vitro and in vivo barcoding, hEPO and FLuc assays, including LNP formulation and animal work. A.K. developed and performed the LC–MS/MS method for all samples. R.S.M. designed and synthesized the combinatorial ionizable lipid library screened in this study. L.H.R., R.S.M. and D.G.A. contributed to the analysis and interpretation of the results and to the writing of the paper.
Corresponding author
Ethics declarations
Competing interests
Three of the authors (L.H.R., R.S.M. and D.G.A.) have filed a patent (US provisional application 63/289,343) on the technology described in this manuscript. The remaining authors declare no competing interests.
Peer review
Peer review information
Nature Biomedical Engineering thanks Xiangrong Song and the other, anonymous, reviewer(s) for their contribution to the peer review of this work.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data
Extended Data Fig. 1 Comparison of formulations containing DOPE or DSPC.
a Data of Fig. 4 replotted with DOPE formulations highlighted in red and DSPC formulations highlighted in blue. b Comparison of LNPs with identical molar compositions, differing only in phospholipid identity. Values shown are mean of n = 3 mice/group, with error bars representing the SD. * p < 0.05, ** p < 0.005, *** p < 0.0005.
Extended Data Fig. 2 Pilot screen using a small subset of the combinatorial library.
a A list of esters (left) and amines (right) used to generate lipids for the pilot screen. b Peptide barcoding analysis of the pilot library. Only lipids that resulted in a peptide dot product > 0.8 are shown. c Individual particle analysis using the top four hits, showing that the top three lipids from the peptide barcoding analysis do not result in significant protein production. d FLuc assay confirming that FLuc mRNA-containing LNPs composed of any of the three ‘false positives’ alone do not result in detectable protein expression, whereas a 1:1 mixture of hEPO mRNA-containing cKK-e12 LNPs and FLuc mRNA-containing ‘false positive’ LNPs results in robust protein expression. Values shown are the mean of n = 3 mice/group, with error bars representing the SD. The FLuc assay of panel d was performed twice with similar results.
Supplementary information
Supplementary Information
Supplementary Methods, Figs. 1–5 and Tables 1–4.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Rhym, L.H., Manan, R.S., Koller, A. et al. Peptide-encoding mRNA barcodes for the high-throughput in vivo screening of libraries of lipid nanoparticles for mRNA delivery. Nat. Biomed. Eng 7, 901–910 (2023). https://doi.org/10.1038/s41551-023-01030-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41551-023-01030-4
This article is cited by
-
In situ combinatorial synthesis of degradable branched lipidoids for systemic delivery of mRNA therapeutics and gene editors
Nature Communications (2024)
-
Strategies for non-viral vectors targeting organs beyond the liver
Nature Nanotechnology (2024)
-
Combinatorial development of nebulized mRNA delivery formulations for the lungs
Nature Nanotechnology (2024)
-
Nano–Bio Interactions: Exploring the Biological Behavior and the Fate of Lipid-Based Gene Delivery Systems
BioDrugs (2024)