Abstract
Reconfigurable photovoltaic modules are a promising approach to improve the energy yield of partially shaded systems. So far, the feasibility of this concept has been evaluated through simulations or simplified experiments. In this work, we analyse the outdoor performance of a full-scale prototype of a series-parallel photovoltaic module with six reconfigurable blocks. Over a 4-month-long period, its performance was compared to a reference photovoltaic module with static interconnections and six bypass diodes. The results show that under partial shading, the reconfigurable module produced 10.2% more energy than the reference module. In contrast, under uniform illumination the energy yield of the reconfigurable PV module was 1.9% lower due to the additional losses introduced by its switching matrix. Finally, a modification in the reconfiguration algorithm is proposed to reduce the output current–voltage range of the module and simplify the design of module-level power converters while limiting the shading tolerance loss.
Similar content being viewed by others
Introduction
The role of urban integrated photovoltaic (PV) systems is becoming increasingly important for the development of net-zero-energy districts and the achievement of the UN Sustainable Development Goals1. Nevertheless, most PV modules currently available in the market have been designed for utility/scale power plants in open landscapes. While in utility/scale PV power plants PV modules are most of the time uniformly illuminated, PV modules installed in densely populated areas are more frequently exposed to partial shading, which leads to a large reduction in the system’s performance ratio2. Therefore, in order to facilitate the integration, maximise the energy yield and minimise the levelised cost of electricity of PV systems in the urban environment, PV modules should be designed keeping the shading performance in mind3,4,5.
Conventional wafer-based PV modules consist of long strings of series-connected solar cells, aimed to keep the module output current low and minimise Joule losses in cables and power converters. The mainstream approaches to improve the shading tolerance of such PV modules consist in adding bypass diodes6,7 and connecting groups of solar cells in parallel8,9. Diodes are used to bypass the sections of a string with shaded solar cells allowing the illuminated sections to continue delivering electricity. Meanwhile, parallel interconnections enable shaded and illuminated cells to produce electricity at the expense of a higher output current10. In practice, PV modules with parallel interconnections are manufactured with cut cells to limit the module’s output current11,12. Some of the most noteable commercially available solutions for shading tolerant module topologies include modules with one bypass diode per cell13,14, series-parallel shingled modules15,16, and the shingle matrix concept17,18. One main advantage of these approaches with parallel interconnections is that the electrical design is generally compatible with the same power converters used for conventional modules. Conversely, the module manufacturing process is often more complex due to the increased number of cells and electrical interconnections per module.
Alternatively, power electronics can be implemented at submodule-level to boost the shading tolerance of PV modules19,20 without the need of modifying the PV module manufacturing process. While full power processing submodule integrated converters (subMICs) have already been implemented in commercially available solutions21,22,23, differential power processing subMICs are an emerging technology that can enable higher power conversion efficiencies24,25.
In this work, we focus on reconfigurable PV modules as an approach to exploit the benefits of the high shading tolerance of parallel interconnections and the low Joule losses of series interconnections26,27. Typically, a reconfigurable PV module consists of two or more blocks of solar cells that are connected to a switching matrix. The switching matrix can dynamically modify the electrical interconnections between the blocks according to the illumination conditions and maximise the module’s output power. In previous work, the authors have presented the design of a fully-reconfigurable series-parallel PV module28,29,30. Simulations results, suggest that under partial shading conditions this reconfigurable PV module could boost the annual energy yield by about 10% in comparison to a PV module with fixed interconnections and six bypass diodes. A similar simulation study on an alternative implementation of a reconfigurable PV module indicates that the annual energy yield of reconfigurable PV modules could be between 5% and 15% higher compared to conventional c-Si PV modules with 3 bypass diodes31.
Although promising, the concept of reconfigurable modules has not yet been validated using actual prototypes in realistic operating conditions. Leveraging previous modelling, design and numerical simulations, we now provide with experimental demonstration that reconfigurable PV modules are capable of outperforming a shade resilient PV module architecture with six bypass diodes. We show the outdoor operation of a highly-performing shade-resilient PV module architecture that does not rely on bypass diodes. Furthermore, we analyse the implications of limiting the degree of reconfigurability of the PV module to simplify the design of a suitable power converter.
This article is organised in the following way. First, we describe the experimental setup used to monitor and compare the performance of the PV modules. Next, we present a direct comparison between the measured performance of the reconfigurable and reference PV modules. Last, we employ submodule current and voltage measurements to analyse the trade-off between shading tolerance and current-voltage output range in the reconfigurable PV module.
RESULTS
Experimental setup
The reconfigurable PV module and a reference PV module with static interconnections compared in this study are schematically represented in Fig. 1. Both modules were laminated in-house using commercial 5-inch mono c-Si solar cells from the same batch. Each PV module is divided into six blocks of cells. Each block consists of 16 solar cells connected in series and a bypass diode. In the reference module, all six blocks are (statically) connected in series as illustrated in Fig. 1a. Instead, in the reconfigurable module28 depicted in Fig. 1b, the blocks of cells are connected to the switching matrix shown in Fig. 1c. It should be noted that the bypass diodes are not required for the operation of the reconfigurable PV module, but they were included in the prototype as an additional safety measure. The switching matrix, implemented with MOSFETs, allows the module to adopt 27 different series-parallel electrical configurations illustrated in Fig. 1d. The 27 configurations are classified as s1p6, s2p3, s3p2 and s6p1, where the first number indicates the amount of blocks that are connected in series forming a string, and the second number indicates how many strings of series-connected blocks are connected in parallel. While s2p3 and s3p2 both represent sets of multiple configurations with the same electrical topology, s1p6 and s6p1 each represent a single configuration where all the blocks are connected in parallel and in series, respectively.
A synchronous reconfiguration algorithm is implemented in a microcontroller to dynamically select the best configuration of the reconfigurable PV module in response to the illumination conditions. The reconfiguration algorithm measures the short-circuit current of the six blocks of cells and aims to connect as many blocks in series as possible without exceeding predefined thresholds that determine the maximum relative current difference for each set of configurations28 as explained in the Methods section. For instance, when the PV module is uniformly illuminated, configuration s6p1 is chosen since it delivers the lowest current and minimises Joule losses. On the other hand, when the PV module becomes partially shaded, configurations with parallel interconnected blocks will be chosen to reduce current mismatch losses. It should be noted that, from all the configurations, s1p6 is the one that presents the highest shading tolerance, but at the same time the one that implies the highest currents and thus Joule losses.
Both PV modules were mounted on a rack as shown in Fig. 2a at the PVMD group monitoring station (51.9997∘ N, 4.3690∘ E) in Delft, the Netherlands. The thermal and electrical performance of the PV modules have been monitored during 4 months under different shading conditions. The experiments were conducted between May and August 2021 to take advantage of the sunniest period of the year in the Netherlands, which was essential to induce partial shading.
During the four-month-long monitoring campaign four shading experiments were performed as illustrated in Fig. 2b–e. During experiment 0, the modules were unshaded and facing South. During experiments 1 to 3, the PV modules were shaded by objects that were symmetrically fixed on the mounting rack to emulate shading caused by structures usually present on rooftops, such as chimneys and dormers. The goal of these experiments was to evaluate the performance of the module when shading different numbers of groups of cells simultaneously. In Experiment 1, the rack was facing South and the shading bars were distributed to shade 3 blocks at the same time. Different bar lengths were used to progressively shade and unshade the blocks during sunrise and sunset. In Experiment 2, the rack was rotated towards Southeast and the shading bars were placed together close to the top of the rack to shade mostly the top left block at noon. In Experiment 3, the shading objects were widened to shade the two blocks on the top left corner of the PV modules at noon.
PV module performance
The power generated by the reconfigurable and the reference PV modules was compared using the maximum power point (MPP) extracted from the I-V curves measured with a BK8616 electronic load and a LPVO PV monitoring unit in combination with an LPVO MP1010F-2 maximum power point tracking (MPPT) unit, respectively. As an example, the power delivered during a clear sky day by both PV modules during experiment 1 is presented in Fig. 3a. It can be noticed that, when the PV modules were partially shaded (i.e., in the morning and the afternoon) the reconfigurable PV module generated more power than the reference module. During these intervals, the voltage time-series in Fig. 3b reveals the progressive activation of the bypass diodes in the reference module and how the reconfigurable PV module switched between configurations throughout the day to minimise current mismatch losses.
Fig. 3a also shows that at noon, when the Sun was in the South and the modules were unshaded, the reference PV module outperformed the reconfigurable PV module. From Fig. 3b it is clear that both modules had the same electrical layout at noon since the reconfigurable module operated in the s6p1 (i.e., all-series) configuration. The voltage (and power) loss in the reconfigurable module during this period is a direct consequence of the resistive losses in the MOSFETs and the PCB traces of the switching matrix, which amount to an increase of 7.9% in the equivalent series resistance of the solar cells28.
The DC energy delivered by the PV modules during each of the experiments is summarised in Table 1. The shading row in Table 1 indicates the fraction of time (excluding dark hours) that the irradiance difference between the least and most illuminated cells in the module was higher than 50%, as a proxy for the amount of time that the modules were partially shaded. Results indicate that the reconfigurable PV module generated about 1.9% less energy than the reference module in the absence of shading due to the additional resistive losses in the switching matrix. Instead, under partial shading conditions (i.e., during experiments 1, 2, and 3), the reconfigurable PV module generated between 4.8% and 13.7% more energy than the reference module. It can be noticed that the difference is larger for the experiments when the PV modules were more frequently subject to partial shading (refer to Shading row in Table 1). Moreover, the DC yield difference between the reconfigurable and reference PV modules also depends on the number of blocks that are simultaneously shaded. From the positions of the shading objects in Fig. 2d, it can be noticed that during experiment 2, only one of the top blocks of cells was shaded most of the time. This shading pattern was effectively mitigated by the REF module, where the shaded block was bypassed and only one sixth of the total module power was lost. As a consequence, the DC yield difference in experiment 2 was significantly lower than in experiments 1 and 3, when more than one block of cells was often shaded at the same time.
It is worth mentioning that the yield of the reconfigurable module in Table 1 excludes the energy consumed by the switching matrix and the sensing circuitry, which is considered negligible. While the switching matrix can be kept in low-power consumption mode in between reconfiguration intervals reducing its consumption to 10 mW, the reconfiguration intervals last in average 150 ms28, during which the power consumption raises to about 1 W. Considering 16 hours of daylight and minutely reconfiguration events, it is estimated that the energy consumed by the electronics in the reconfigurable module was approximately 20 Wh for the entire monitoring campaign, which is about 0.02% of the total energy delivered by the reconfigurable PV module.
The DC yield difference between both modules was also evaluated as a function of the solar position. The results presented in Supplementary Fig. 1 show that in the absence of shading, the reference module performed mostly better than the reconfigurable module during of Experiment 0. Instead, during the experiments when shading objects were mounted on the rack, the reconfigurable module almost always outperformed the reference module except in two particular situtations: (1) when the sun was in front of the module (i.e., around South in Experiment 1, and around Southeast in Experiments 2 and 3), because the shading objects on the sides of the modules were not causing shading, and (2) when the sun was behind the plane of array, because the modules received only diffuse and reflected irradiance and the current mismatch was significantly reduced.
The pie charts in Fig. 4 show the percentage of the energy delivered by the different configurations of the reconfigurable module during each of the shading experiments. As expected, during experiment 0, the reconfigurable PV module was mostly operated in the s6p1 (all-series) configuration because the module was uniformly illuminated. During experiments 1 to 3, the algorithm frequently chose configurations with parallel interconnections to reduce the current mismatch caused by the partial shading. In particular, it should be noticed the s1p6 (all-parallel) configuration contributed to a significant share of the total generated electricity in all three experiments when the PV module was partially shaded. As explained before, the s1p6 configuration implies low output voltages and high output currents that entail a burden on the design and performance of the power converter for the reconfigurable PV module.
Limiting the electrical operating range
Results show that in the absence of shading, the REC module is mostly operated in the s6p1 configuration and delivers power at approximately the same current as the REF module. Instead, when there is partial shading, the reconfigurable PV module tends to deliver higher currents because the algorithm chooses configurations with different combinations of blocks connected in parallel. The electrical operating ranges of the REF and REC modules are compared in Fig. 5, where it is illustrated how much energy was delivered at each voltage, current and power level during the experiments when the PV modules were partially shaded. In Fig. 5c, it can be noticed that the REC module generated up to 40.8 A, about 6 times more than the maximum current of 7.2 A delivered by the REF module in Fig. 5a. Besides, the output voltage of the REF module ranged from 13.3 V to 57.9 V, while the output voltage of the REC module range from 5.6 V to 52.3 V. As a result of the extended electrical output range, a power converter for a reconfigurable PV module would be larger, less efficient and/or more expensive than a power converter for a conventional PV module. Although the design of a suitable power converter for a reconfigurable PV module is beyond the scope of this work, one way to reduce the burden on the design of such power converter is by adapting the operation of the reconfiguration algorithm. This specific approach will be addressed in the rest of this Section.
One straightforward approach to ease the design of the power converter consists in limiting the electrical output range of the reconfigurable module. This can be achieved by avoiding the configuration s1p6, which delivers the highest currents and lowest voltages. When configuration s1p6 is avoided, the reconfiguration algorithm chooses as an alternative the best s2p3 configuration, and consequently, the reconfigurable module becomes less shading tolerant.
Even though the best s2p3 configuration was not measured, it can be reconstructed using the I–V curves of the different blocks, which were regularly measured during the whole experimental campaign with the current and voltage sensors integrated in the switching matrix. The I–V curve of the different module configurations were recreated by interpolating and adding the measured voltages (in the case of series connections) or currents (in the case of parallel connections) of each of the six blocks of cells in Fig. 1c. This method for generating I–V curves has been validated for various PV module topologies10,28.
Figure 6 depicts the operating range of the reconfigurable PV module for the presented shading scenarios after modifying the algorithm to preclude configuration s1p6. While the REC module with the original reconfiguration algorithm generated in average 10.2% more energy than the REF module (only considering shading experiments 1 to 3), the energy yield of the REC module with the modified algorithm would be 6.4% higher than the REF module. In return, the maximum output current of the reconfigurable PV module would drop to 20.2 A and the output voltage would range from 10.7 V to 52.3 V.
Discussion
Our measurements indicate that in the absence of shading the reconfigurable PV module performed 1.9% worse than the reference module due to the additional resistive losses introduced by the switching matrix. Instead, when the PV modules were subject to partial shading, the reconfigurable PV module delivered an average 10.2% more energy. In particular, the difference between the energy yield of both modules was larger for shading scenarios in which two or more blocks of cells were often shaded at the same time.
During all the shading experiments, about 40% of the energy was delivered by the s1p6 configuration, in which all six blocks of cells are connected in parallel. Although the s1p6 is the most shading tolerant of the 27 possible configurations, it is also the one that generates the highest currents and thus may lead to the highest losses at system level. To avoid high currents, we analysed the performance of a hypothetical reconfigurable PV module in which the configuration s1p6 is precluded. This analysis was performed by using the I–V curves of each block of cells, that were regularly measured during the mentioned shading experiments, to reconstruct the I–V curve of different module configurations. On the one hand, we show that this approach limits the maximum current and the minimum voltage generated by the reconfigurable PV module, which implies a simpler design of the power converter and reduced Joule losses in cables. On the other hand, it was found that when the s1p6 configuration is precluded, the yield of reconfigurable module would be reduced on average by 3.8%. It is expected that by reducing the output current of the PV module to approximately 20 A, Joule losses in cables and conversion losses in power electronic devices would also be significantly smaller. In order to verify whether it is beneficial to avoid configuration s1p6, the complexity of the design and efficiency of power converters for both versions of the reconfigurable module must be carefully investigated and system-level analyses must be performed.
In the future, asynchronous algorithms together with other sensed parameters at the level of the PV module can be exploited to improve the performance of reconfigurable modules. Most interestingly, an approach based on machine learning could be implemented to facilitate an AI engine which optimally controls the reconfiguration. Finally, the presence of a microcontroller in the envisioned smart junction box can also be used to tokenise and trade energy packets in the future digital energy market.
Methods
Each of the blocks of 16 series-connected solar cells, that form both the reference and reconfigurable PV modules, were laminated in-house using the materials listed in Supplementary Table 1. The electrical characteristics of the solar cells are given in Supplementary Table 2 and, after lamination, the I–V curve of each block was measured using an EternalSunSpire A+A+A+ Xenon Single Long Pulse flash simulator to check the uniformity of the I–V characteristics of the blocks of cells under AM1.5g illumination.
The temperature of the modules was measured using T-type thermocouples attached to the backsheet of the PV modules and thermally insulated from the air at the positions indicated with green crosses in Fig. 1a, b.
The electrical performance of the reference PV module (REF) was monitored using an LPVO PV monitoring unit (PVMU) in combination with an MP1010F-2 MPPT unit32. The PVMU was used to perform I–V sweeps on the reference PV module at every minute. Meanwhile, the MP1010F-2 MPPT unit was employed in between these sweeps, ensuring a continuous extraction of power from the reference module by operating it at its maximum power point.
The electronics required to operate and monitor the reconfigurable PV module were installed in the electrical box shown in Supplementary Fig. 2, which was mounted on the rear side of the rack. The microcontroller unit, where the reconfiguration algorithm shown in Fig. 7 was implemented, controls the state of the MOSFETs of the switching matrix through a driver circuit.
In this prototype, all the devices were powered by an external power supply. Nevertheless, the power consumption of the switching matrix is minimal and it can be eventually self-powered by the solar cells in the PV module. The electrical performance of the reconfigurable PV module (REC) was monitored using a BK8616 (B&K PRECISION) electronic DC load which was connected to the output of the switching matrix. Both the REC and the REF PV modules were connected to the respective measurement equipment using 4-wire connections. Although it was not possible to monitor both modules using the same equipment due to the differences in the electrical output ranges, the selected equipment has similar measurement accuracy as shown in Supplementary Table 3. The maximum measurement error was 7.5 mW and 5.5 mW with the BK8616 and the LPVO PVMU, respectively.
In addition, the voltage and current sensors integrated in the switching matrix (see Fig. 1c) were calibrated to measure the voltage and current of each individual block. Only the current sensors were required for the operation of the reconfiguration algorithm. The voltage sensors were added to enable the measurement of block-level I–V curves, which were then processed to emulate different operating conditions.
The measurement procedure for the reconfigurable module is shown in Fig. 8. The setup consisted of a PC that was used to synchronise the operation of the switching matrix and the DC load, and to store the measurements. Reconfiguration was performed on a minutely basis by the microcrontroller in the switching matrix upon the reception of the triggering command sent by the PC. Before each reconfiguration event, all the blocks in the reconfigurable PV module are connected in parallel to measure the I–V curves of each block using the current and voltage sensors integrated in the switching matrix. Next, the microcontroller of the switching matrix executes the reconfiguration algorithm and the reconfigurable module switches to the optimal configuration. Finally, the I–V curve of the reconfigurable module is measured with the electronic DC load and then the module is kept at its maximum power point using a perturb and observe (P&O) maximum power point tracking algorithm, also implemented through the BK8616 electronic load, for 1 min until the next reconfiguration event. It should be noted that under normal operation, it is not necessary to measure the I–V curves of each block of cells because the reconfiguration algorithm only requires the short-circuit current to find the best module configuration28.
Reporting summary
Further information on research design is available in the Nature Portfolio Reporting Summary linked to this article.
Data availability
The PV module performance data generated in this study have been deposited in the 4TU.ResearchData data repository [https://doi.org/10.4121/52702ca1-87ca-4429-b3ec-11cf2eb1c921]33. Source data are provided with this paper.
References
Sustainable development goals (United Nations, accessed 5 November 2023); https://www.un.org/sustainabledevelopment/energy/.
Moraitis, P., Kausika, B. B., Nortier, N. & van Sark, W. Urban environment and solar PV performance: the case of the Netherlands. Energies 11, 1333 (2018).
Klasen, N., Lux, F., Weber, J., Roessler, T. & Kraft, A. A comprehensive study of module layouts for silicon solar cells under partial shading. IEEE Journal of Photovoltaics 12, 546–556 (2022).
Calcabrini, A. et al. Low-breakdown-voltage solar cells for shading-tolerant photovoltaic modules. Cell Reports Physical Science 3, 101155 (2022).
Başoğlu, M. E. Comprehensive review on distributed maximum power point tracking: Submodule level and module level MPPT strategies. Solar Energy 241, 85–108 (2022).
Pannebakker, B. B., de Waal, A. C. & van Sark, W. Photovoltaics in the shade: one bypass diode per solar cell revisited. Progress in Photovoltaics: Research and Applications 25, 836–849 (2017).
Sinapis, K., Rooijakkers, T. T., Pacheco Bubi, R. & van Sark, W. Effects of solar cell group granularity and modern system architectures on partial shading response of crystalline silicon modules and systems. Progress in Photovoltaics: Research and Applications 29, 977–989 (2021).
Carr, A. J., et al. Tessera: Scalable, shade robust module. In IEEE 42nd Photovoltaic Specialist Conference (PVSC), 1-5 https://doi.org/10.1109/PVSC.2015.7356286 (2015).
Kunz, O., Evans, R. J., Juhl, M. K. & Trupke, T. Understanding partial shading effects in shingled pv modules. Solar Energy 202, 420–428 (2020).
Calcabrini, A., Weegink, R., Manganiello, P., Zeman, M. & Isabella, O. Simulation study of the electrical yield of various PV module topologies in partially shaded urban scenarios. Solar Energy 225, 726–733 (2021).
Mittag, M. et al. Cell-to-Module (CTM) Analysis for Photovoltaic Modules with Shingled Solar Cells. In IEEE 44th Photovoltaic Specialist Conference (PVSC) 1531-1536 https://doi.org/10.1109/PVSC.2017.8366260 (2017).
Brecl, K., Bokalič, M. & Topič, M. Annual energy losses due to partial shading in PV modules with cut wafer-based Si solar cells. Renewable Energy 68, 195–203 (2021).
Hanifi, H. et al. A novel electrical approach to protect PV modules under various partial shading situations. Solar Energy 193, 814–819 (2019).
AE Smart Hot-Spot Free (AE Solar, accessed 5 November 2023); https://ae-solar.com/products/ae_hm6_66_370w-400.
Performance Solar Panels (Maxeon Solar Technologies, accessed 5 November 2023); https://maxeon.com/us/solar-panel-products/performance-solar-panels.
Solaria Advantage: Power In The Shade (Solaria, accessed 5 November 2023) https://www.solaria.com/blog/solar-shading.
Klasen, N., Weisser, D., Rößler, T., Neuhaus, D. H. & Kraft, A. Performance of shingled solar modules under partial shading. Progress in Photovoltaics: Research and Applications 30, 325–338 (2022).
Shingle Matrix Technology (M10 Solar Equipment, accessed 5 November 2023); https://www.m10solar.com/en/solutions/shingle-matrix-technology/.
Mazumdar, P., Enjeti, P. N., & Balog, R. S. Smart PV modules - Design considerations. In IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), 1-6 https://doi.org/10.1109/PEDES.2012.6484408 (2012).
Gao, Q., Zhang, Y., Yu, Y. & Liu, Z. A direct current-voltage measurement method for smart photovoltaic modules with submodule level power optimizers. Solar Energy 167, 52–60 (2018).
Deline, C., Meydbray, J., & Donovan, M. Photovoltaic Shading Testbed for Module-Level Power Electronics: 2016 Performance Data Update. Technical Report NREL/TP-5J00-62471, (National Renewable Energy Laboratory, 2016).
Trinapeak eBook (Trina Solar, accessed 5 November 2023); https://pages.trinasolar.com/eBook-Trinapeak-US.html.
Taylor brochure (Taylor Technologies BV, accessed 5 November 2023); https://www.taylor.solar/support#installers-downloads.
Doubleday, K., Choi, B., Maksimovic, D., Deline, C. & Olalla, C. Recovery of inter-row shading losses using differential power-processing submodule DC-DC converters. Solar Energy 135, 512–517 (2016).
Gokdag, M., Akbaba, M. & Gulbudak, O. Switched-capacitor converter for PV modules under partial shading and mismatch conditions. Solar Energy 170, 723–731 (2018).
Nguyen, D. & Lehman, B. An adaptive solar photovoltaic array using model-based reconfiguration algorithm. IEEE Trans. Ind. Electron. 55, 2644–2654 (2008).
Velasco-Quesada, G., Guinjoan-Gispert, F., Piqué-López, R., Román-Lumbreras, M. & Conesa-Roca, A. Electrical PV Array Reconfiguration Strategy for Energy Extraction Improvement in Grid-Connected PV Systems. IEEE Trans. Ind. Electron. 56, 4319–4331 (2009).
Calcabrini, A. et al. A fully reconfigurable series-parallel photovoltaic module for higher energy yields in urban environments. Renewable Energy 179, 1–11 (2021).
Isabella, O., Ziar, H., & Zeman, M. Smart cell-level power managed PV module. Patent WO2 019 143 242A4 https://patents.google.com/patent/WO2019143242A4/ (2019).
Zeman, M., Isabella, O., Calcabrini, A., Stornelli, V., & Muttillo, M. Switching matrix for reconfigurable PV modules and systems. Patent WO2 021 206 540 A1 https://patents.google.com/patent/WO2021206540A1 (2021).
Baka, M., Manganiello, P., Soudris, D. & Catthoor, F. A cost-benefit analysis for reconfigurable PV modules under shading. Solar Energy 178, 69–78 (2019).
PV monitoring solutions (Laboratory of Photovoltaics and Optoelectronics - University of Ljubljana, accessed 5 November 2023); http://lpvo.fe.uni-lj.si/fileadmin/files/Storitve/PVmonitoring/LPVO_leaflet_PV_monitoring_system.pdf.
Calcabrini, A., Muttillo, M., Zeman, M., Manganiello, P., & Isabella, O. Data underlying the publication: Electrical performance of a fully reconfigurable series-parallel photovoltaic module. 4TU.ResearchData. https://doi.org/10.4121/52702ca1-87ca-4429-b3ec-11cf2eb1c921 (2023).
Acknowledgements
This work is supported by the sector plan of the Dutch government in photovoltatronics research. Furthermore, the authors would like to thank EternalSun Spire (www.eternalsunspire.com), especially Stefan Roest and Elias Garcia Goma for helping us to test the PV modules at EternalSun’s facilities.
Author information
Authors and Affiliations
Contributions
Conceptualisation: A.C., M.M., P.M and O.I.; Methodology: A.C., M.M. and P.M.; Hardware: M.M. and A.C.; Software: M.M. and A.C.; Investigation: A.C., M.M. and P.M.; Resources: P.M., O.I. AND M.Z.; Writing - Original Draft: A.C.; Writing - Review & Editing: M.M., P.M., O.I. and M.Z.; Supervision: P.M., O.I and M.Z.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature Communications thanks Victor Flores Mendes and Yves-Marie Saint-Drenan for their contribution to the peer review of this work. A peer review file is available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Source data
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Calcabrini, A., Muttillo, M., Zeman, M. et al. Electrical performance of a fully reconfigurable series-parallel photovoltaic module. Nat Commun 14, 8113 (2023). https://doi.org/10.1038/s41467-023-43927-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-023-43927-3
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.