Abstract
This article forms part of a series looking at management of patients with tooth wear. Articulated study casts can be essential in assisting the clinician to plan and communicate proposed treatment to the dental technician and patient. Their production is often seen as straightforward, but a lack of attention to detail can quickly lead to articulated casts that do not replicate the patient clinical presentation. This in turn will lead to inaccurate planning and potentially a suboptimal treatment outcome. This article discusses a collection of the clinical records needed to produce accurate articulated study casts, which can be utilised for tooth wear planning. It also aims to present the evidence base for the recommendations outlined.
Key points
Articulated study casts can form an integral part of the treatment planning process for patients with complex tooth wear.
The stages to produce accurately mounted study casts include recording impressions to achieve high-quality study casts, recording a facebow, recording a centric relation record and lab mounting. Each stage needs to be carried out with the greatest of care to ensure consistent results.
After the records have been collected and processed by the laboratory, it is essential that the mounted study casts are verified for accuracy. Accuracy is by no means a guarantee and errors can occur at any point. This can result in mounted study casts that do not replicate the tooth contacts found clinically.
Similar content being viewed by others
Introduction
Articulated study casts can form an integral part of the treatment planning process for patients with complex tooth wear. The use of analogue techniques to produce articulated study casts is well documented.1,2,3,4,5,6,7 The use of digital techniques will be discussed in a separate article within this series.
Articulated study casts serve as a medico-legal record of the patients' pre-treatment presentation. They can be used to examine the static and dynamic occlusal contacts without muscular guarding or the visual limitation of the soft tissues. Duplicated study casts can be modified with mock equilibrations, tooth removal, or additive waxing, to simulate proposed treatment plans. They are also useful in the production of guides and stents. The production of articulated study casts comes at significant expense and must provide added value. They are not always necessary but are invaluable when executing complex tooth wear cases.
The stages to produce accurately mounted study casts include:
Recording impressions to achieve high-quality study casts
Recording a facebow
Recording a centric relation record (CRR)
Lab mounting and verification.
This article will aim to outline a simple and evidence-based summary of how to execute the stages above to a high standard.
Stage 1: recording impressions to achieve high-quality study casts
Alginate impression material in a universal stock tray will provide sufficient accuracy to produce high-quality study casts. Alginate provides a cheap and well-tolerated impression material. However, an understanding of the material's limitations is essential if it is to be used consistently.
Storage
Alginate is most commonly bought in bulk. After opening, the loose alginate is stored in an airtight container (Fig. 1). It is essential that alginate stored like this is shaken thoroughly before use. This serves two purposes. Firstly, it distributes the top layer and moisture-compromised alginate evenly throughout the mix. Secondly, it distributes the alginate evenly by weight. Alginate can be measured by weight or volume. Depending on how densely packed the alginate is, a single scoop by volume can vary considerably in weight. By shaking the alginate tub before measuring, the mix will be more homogenous.
Handling
By altering the powder-to-water ratio when mixing alginate, it is possible to manipulate the consistency. For the best results, it is best to maintain the volume of powder and vary the amount of water. Altering the powder-water ratio by up to 25% does not affect the accuracy of the impression.8 Setting time of alginates can vary considerably between manufacturers. Most setting times are based on 22 °C tap water and average 2-3 minutes. By increasing or decreasing the temperature of the water, the setting time can be manipulated. There is some evidence to suggest that higher temperature water results in less dimensionally accurate impressions. For the best results, cold water is recommended.9,10
Tray selection
The tray is the foundation of an accurate impression. Classically, metal rim lock trays were recognised to be the gold standard. This was born out of concerns about the rigidity of newer plastic stock trays, which were thought to flex and then rebound on impression removal. In reality, the studies that have investigated this have been concerned with high viscosity silicone putty, not alginate.11 When using alginate, universal plastic stock trays provide adequate rigidity.
Sizing the tray appropriately is essential. There should be good material support around the full arch and 3-5 mm clearance from the teeth around all aspects of the tray to allow adequate alginate thickness. Tray perforations through the alginate can lead to inaccurate impressions and ideally should be avoided, particularly in key areas (Fig. 2). Stock trays of adequate width will often not be long enough to capture the full length of the arch. In an attempt to capture the most posterior teeth, the clinician will often seat the tray too far back, resulting in the anterior teeth perforating through the impression material as the tray is rotated upwards. A better technique is to modify the stock tray to increase its length with a rigid material, such as an impression compound (Fig. 3). It can be tempting to use wax for this purpose, as it is cheap and fast to use, but it is flexible and can be easily distorted.
Special attention needs to be paid to large edentulous saddles or high-vaulted palates. Alginates do not self-support well and can sag before the gelation phase is complete. The tray is best augmented with compound or putty in these areas to prevent this (Fig. 4).12
Mechanical retention is provided in stock trays by perforations. This may not be sufficient to ensure impression accuracy. The use of alginate adhesive is recommended. In vitro studies have demonstrated that it can improve the dimensional accuracy of alginate impressions.13,14 It is essential that pooled adhesive is not left in the tray as this can act as a lubricant (Fig. 5). Attention to detail and ensuring that the adhesive is wrapped 2-3 mm on to the exterior of the tray will also help.
Mouth preparation
Mouth preparation should be carried out before making your alginate impression to achieve enhanced surface detail.15 The teeth should be gently dried with suction or gauze. Over-drying with 3-in-1 air should be avoided. If the teeth are over-dried, the alginate can form a chemical bond to the hydroxyapatite crystals. This happens most commonly if the pellicle is removed from the tooth when multiple sequential impressions are taken. It can be beneficial if alginate is smeared deeply into the occlusal fissures of the teeth (Fig. 6). This can reduce blebs and air blows. After a full set, the alginate impression should be removed with a sharp snap movement. Gentle wiggling or gradual unseating can cause viscous flow and limit the elastic recovery and accuracy of the impression. The removal of any unsupported excess alginate with a scalpel will reduce the chance of distortion, as the impression is packed for transport. This trimming of the alginate also allows an opportunity to check that the alginate is properly adhered to the tray (Fig. 7).
Disinfection and preparation for transport
A standard alginate impression is 85% water and is subject to ready release (syneresis) and absorption (imbibition) of water. Special attention has to be paid to impression disinfection, storage, transportation and the time delay until pouring, to prevent suboptimal performance.
The disinfection of an alginate impression can be completed by either immersion in a disinfectant bath or soaking with a disinfectant spray. Both have been shown as effective and achieve cross-infection control. The effect of disinfection on dimensional accuracy has been extensively researched. A recent critical review of the literature demonstrates that there are negligible effects on dimensional accuracy of the impression as long as the manufacturer's instructions are followed.16,17
It is commonly quoted that distortion of an alginate impression can start to develop in as little as 12 minutes after removal.18 This has led to the belief that an alginate impression needs to be cast as soon as possible after capture. This has been disputed in other publications and largely depends on the alginate being used.19,20 There have been huge advances in alginate in recent years, with some manufacturers claiming their alginate can maintain dimensional stability for as many as seven days. The evidence would support the dimensional stability of these newer extended pour alginates.21 That said, we cannot expect standard alginates to perform in this way. It is essential that these are poured as soon as possible.22 If there is likely to be periods of over 24 hours between recording and pouring of your impression, an extended pour alginate or addition cure silicone should be considered.23
Stage 2: recording a facebow transfer
The importance of the facebow transfer can be conceptionally difficult to grasp. A facebow allows us to record the spatial orientation of the maxilla to the terminal hinge axis clinically and then transfer this information via the mounting process to an articulator (Fig. 8).
Aesthetically, it allows any incisal and occlusal cants, relative to the horizontal reference plane being utilised, to be recorded. Although this can be achieved in other ways, a facebow is quick and predictable (Fig. 9). If this information is not provided, the technician's default mounting position will be to align the occlusal plane to the bench top. The facebow transfer also gives functional benefits. By mounting the maxillary model on the articulator at the same position relative to the terminal hinge axis as is present anatomically, the arc of opening and closing taken by the mandible is replicated on the articulator (Fig. 10). This is important and ensures that the morphology of any new prosthetic teeth take in to account the patient's arc of closure and rotation. This is particularly important if the occlusal vertical dimension is to be opened or closed on the articulator.
Limitations of facebows
There are many different articulator manufacturers on the market, each with their own specific facebow. It is essential that the correct facebow to the articulators used in your chosen laboratory is selected. Facebows rely on two posterior reference points and one anterior reference point when positioning their upper member. Confusingly, these reference points change depending on the brand of facebow utilised. It is therefore essential that the manufacturer's instructions are followed.
Most facebows utilise the external auditory meatus (EAM) as a convenient, but arbitrary, posterior reference point to represent the terminal hinge axis (THA). The THA is an imaginary line drawn between the patient's condyles around which the mandible rotates in early opening and late closing. Because of this, they are more appropriately named 'earbows' (Fig. 11). The EAM is not the exact position of the THA, but most earbows are accurate to 6 mm.24
Manufacturers have gone to great lengths to construct the upper member of their facebow in order to account for the average discrepancy between the anatomical position of the THA and the EAM. But there is no doubt that this 'one size fits all' approach will lead to inaccuracy. The impact of this has been studied by researchers and it has been concluded that even a 5 mm discrepancy between the EAM and the THA will result in only a 0.2 mm discrepancy in mandibular position on closure when a 3 mm thick CCR inter-occlusal record is used.25 This discrepancy is unlikely to significantly impact most cases and is a small price to pay for the incredible ease with which the 'earbow' can be used clinically. Greater accuracy can be achieved but involves advanced equipment, such as pantographs and fully adjustable articulators.
When recording the facebow, a non-flexible material, such as silicone bite registration material or beauty wax, should be used to record the tooth positions on the bite fork. It should be possible to stabilise the study cast on the bite fork with three well-distributed points of contact. If this is not possible due to the distribution of the teeth, then a wax record block will be necessary. Ideally, this should be constructed on the model to be mounted to improve accuracy of fit.
Stage 3: recording a centric relation record
Centric Relation (CR) is a maxillomandibular relationship, independent of tooth position. In CR, the mandible is restricted to a purely rotation movement. Diagnostic casts are mounted on the articulator in CR using a CRR.
Passive rotation of the mandible
The first stage in recording a CRR is to ensure that the clinician is able to reproducibly rotate the patient's mandible with the condyles fully seated. There is debate in the literature about the true anatomic position of the condyle when the mandible is in CR.26 But as clinicians, we recognise CR as the familiar feel of 'passive rotation' of the mandible. An accurate CRR can be time-consuming to achieve depending on the degree of muscle guarding the patient has. It is best to test the degree of muscle guarding by gently manipulating the mandible up and down (Fig. 12). There are various techniques to achieve this but the most common is bi-manual manipulation.27
Passive rotation of the mandible is generally either immediately possible or stunted and difficult. Movement of the patient's head while manipulating the mandible indicates that muscle guarding is present. If muscle guarding is present, then the clinician should seek to achieve muscle relaxation, or deprograming, before proceeding to record the CRR. There is a variety of different techniques that can be used to achieve this and they are best thought of like a ladder of increasing complexity (Box 1). The clinician should only ascend to the next rung as each of the simpler techniques has been exhausted and failed to deprogramme the muscles successfully. The most straightforward technique that can be successful in achieving muscle relaxation is to simply hold the teeth apart for 2-3 minutes. This is easily achieved using cotton wool rolls (Fig. 13). It is essential that during this process, the patient should not be allowed to re-close their teeth into the inter-cuspal position. This will immediately re-introduce a degree of muscle guarding.
In some patients, this simple technique is not enough, and they require more dynamic movement of the mandible to allow relaxation of the muscles. The use of a mirror handle or a small stack of wooden spatulas can be useful, encouraging the patient to slide their mandible forward and back on them (Fig. 14). A leaf gauge can also be useful for this purpose. The use of which is well-explained in published articles.28
If this is unsuccessful a Lucia Jig can be used.29,30,31 These can be bought prefabricated and relined, or constructed from scratch using pattern resin or cold cure acrylic. The advantage of the Lucia Jig is that it can be left in place for extended periods without direct clinician input. This is hugely advantageous if the patient's muscles need longer to deprogramme. The Lucia Jig will often need adjusting to achieve a single lower incisor contact. The production of an even gothic arch tracing on the Lucia Jig indicates that patient has been deprogrammed (Fig. 15). If the patient is partially dentate, it may not be possible to construct a Lucia Jig and the clinician could consider using a central bearing apparatus as an alternative.
If all of the steps above are exhausted and muscle guarding remains, it may be that longer-term deprograming is needed. This can be achieved with a stabilisation splint. This appliance can be sequentially equilibrated until such time, as consistent occlusal contacts are recorded at multiple review appointments. This is unnecessary in all but the most extreme of cases.
Recording the centric relation record
A CRR should be recorded with the maxillary and mandibular teeth apart. It should never be perforated by the occlusal contacts. Traditionally, a trimmed piece of beauty wax has been used to record the CRR. A modern alternative is to use a green stick impression compound stop and poly vinyl silicone (PVS) bite registration material (Fig. 16). It can also be useful to mock the anterior stop in composite to represent where your proposed build-ups will extend to (Fig. 17).
It is important that a rigid PVS material is used, ideally one with a Vickers hardness of D or above. Pink or silver wax are not suitable to record a CRR as they are not rigid at room temperature.32
It is essential that the CRR has a minimum of tripod contacts on the remaining teeth. If the patient has multiple missing posterior teeth, there may be a need to include wax registration rims as part of the CRR (Fig. 18). Wax rims can introduce large errors into the registration process if not managed carefully due to the differential between tooth and mucosa compressibility. Ideally, the wax registration blocks should have been fabricated on the study casts that are to be articulated. It is best to prevent wax registration rims coming into direct contact with each other, with their final vertical position recorded using silicone registration material. This will reduce the risk of them being compressed into the mucosa and rebounding when placed on to a study cast (Fig. 19).
Silicone bite registration material records more surface detail than alginate. The high degree of accuracy with which the silicone captures the fissure pattern of the teeth prevents the occlusal record from fully seating on the study casts produced from the alginate impressions (Fig. 20). It is therefore essential that the CRR is 'cut back' to show cusp tips only. It is also essential for the same reason that blebs and air blows are removed from the stone model. Without doing so, the registration will not fully seat down (Fig. 21, Fig. 22). It can be advantageous to record the impressions and CRR at separate staged appointments, as this allows the stability of the CRR to be checked in clinic before sending to the laboratory for mounting.
Stage 4: lab mounting and verification
After the records above have been collected and processed by the laboratory, it is essential that the mounted study casts are verified for accuracy. Accuracy is by no means a guarantee and errors can occur at any point. This can result in mounted study casts that do not replicate the tooth contacts found clinically.
The occlusion should already have been examined in detail clinically.33,34,35,36 Verification can be completed in different ways. The recording of multiple CRRs allows the use of a Centri-Check.37 More practically, the initial tooth contact in CR can be marked with articulating paper clinically. Occlusal indicator wax can also be used to record and retain this tooth contact. An occlusal sketch could be used for the same purpose (Fig. 23).
When the models are returned from the laboratory, the initial tooth contact on the study casts should replicate those found clinically. This can be marked with articulating foil and confirmed with the occlusal indicator wax or occlusal sketch (Fig. 24). If the clinical occlusal contacts are not replicated, then retaking the CRR or remounting the casts may need to be considered.
Conclusion
The production of accurate articulated study casts is a time-consuming process. Each stage in the process must be executed to the highest standard if we are to be successful.
Alginate provides a cheap and accurate impressions material but must be handled with care to achieve the best results. The use of a facebow is not always necessary, particularly if not increasing the occlusal vertical dimension. But when needed, the ear bow can provide adequate accuracy for most tooth wear cases, even accepting its limitations relative to a pantograph with fully adjustable articulator. The recording of a CRR can be challenging, particularly in patients with extensive muscle guarding. But by using a staged approach to deprogram the patient's muscles, and selection of the correct inter-occlusal material, an accurate record can be achieved . Even with excellent clinical techniques and care, it cannot be assumed that the lab mounting process will progress without fault. The verification of mounting accuracy in comparison to the patient's clinical tooth contacts is essential for success.
References
Mehta S, Banerji S. The application of occlusion in clinical practice part 2: the taking of occlusal records. Dent Update 2019; 46: 30-41.
Banerji S, Mehta S. The application of occlusion in clinical practice part 3: practical application of the essential concepts in clinical occlusion. Dent Update 2019; 46: 100-112.
Mehta S, Banerji S. The application of occlusion in clinical practice part 1: essential concepts in clinical occlusion. Dent Update 2019; 45: 1003-1015.
Hassall D. Centric relation and increasing the occlusal vertical dimension: concepts and clinical techniques - part one. Br Dent J 2021; 230: 17-22.
Hassall D. Centric relation and increasing the occlusal vertical dimension: concepts and clinical techniques - part two. Br Dent J 2021; 230: 83-89.
Rosenstiel S, Land M, Fujimoto J. Contemporary Fixed Prosthodontics. 4th ed. Missouri: Mosby, 2006.
Shillingburg H, Sather D, Wilson E et al. Fundamental of Fixed Prosthodontics. 4th ed. Chicago: Quintessence Publishing, 2012.
Abdelraouf R M, Bayoumi R E, Hamdy T M. Effect of Powder/Water Ratio Variation on Viscosity, Tear Strength and Detail Reproduction of Dental Alginate Impression Material (In Vitro and Clinical Study). Polymers (Basel) 2021; 13: 2923.
Nili M, Davari O. Comparsion of the Effect of Different Temperatures of Water on Dimensional Accuracy of Bayer and Iralign Alginate. Shiraz J Dent 2006; 7: 89-97.
Harris W T Jr. Water temperature and accuracy of alginate impressions. J Prosthet Dent 1969; 21: 613-617.
Cho G C, Chee W W L. Distortion of disposable plastic stock trays when used with putty vinyl polysiloxane impression materials. J Prosthet Dent 2004; 92: 354-358.
Van Noort R. Introduction to Dental Materials. 4th ed. Missouri: Mosby, 2013.
Marafie Y, Looney S, Nelson S, Chan D, Browning W, Rueggeberg F. Retention strength of impression materials to a tray material using different adhesive methods: an in vitro study. J Prosthet Dent 2008; 100: 432-440.
Leug K C, Chow T W, Woo E C, Clark R K. Effect of adhesive drying time on the bond strength of irreversible hydrocolloid to stainless steel. J Prosthet Dent 1999; 81: 586-590.
Al Qahtani M A, Alrefaie M, Altamimi A et al. Evaluation of pre-alginate impression preparation methods in the surface accuracy of dental cast. Saudi Dent J 2019; 31: 451-456.
Kotsiomiti E, Tzialla A, Hatjivasiliou K. Accuracy and stability of impression materials subjected to chemical disinfection - a literature review. J Oral Rehabil 2008; 35: 291-299.
Taylor R L, Wright P S, Maryan C. Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater 2002; 18: 103-110.
Miller M W. Syneresis in alginate impression materials. Br Dent J 1975; 139: 425-430.
Dahl B L, Dymbe B, Valderhaug J. Bonding properties and dimensional stability of hydrocolloid impression systems in fixed prosthodontics. J Prosthet Dent 1985; 53: 796-800.
Wadhwa S S, Mehta R, Duggal N, Vasudeva K. The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials. Contemp Clin Dent 2013; 4: 313-318.
Porrelli D, Berton F, Piloni A C et al. Evaluating the stability of extended-pour alginate impression materials by using an optical scanning and digital method. J Prosthet Dent 2021; DOI: 10.1016/j.prosdent.2020.06.022.
Sedda M, Casarotto A, Raustia A, Borracchini A. Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemp Dent Pract 2008; 9: 59-66.
Naumovski B, Kapushevska B. Dimensional Stability and Accuracy of Silicone-Based Impression Materials Using Different Impression Techniques - A Literature Review. Pril (Makedon Akad Nauk Umet Odd Med Nauki) 2017; 38: 131-138.
Teteruck W R, Lundeen H C. The accuracy of an ear-face bow. J Prosthet Dent 1966; 16: 1039-1046.
Weinberg L A. An evaluation of the face-bow mounting. J Prosthet Dent 1961; 11: 32-42.
Keshvad A, Winstanley R B. Review An appraisal of the literature on centric relation. Part I. J Oral Rehabil 2000; 27: 823-833.
Orthlieb J-D, Hernandez G, Darmouni L, Ré J P, Girardeau A, Slavicek G. Myostabilized centric relation. Int J Stomatol Occlusion Med 2011; 4: 87-94.
Campbell S. Technique tips - a simplified method of recording centric relation contact position (crcp) using the leaf gauge. Dent Update 2013; 40: 780.
Lucia V O. A technique for recording centric relation. J Prosthet Dent 1964; 14: 492-505.
Wilson P H R, Banerjee A. Recording the retruded contact position: a review of clinical techniques. Br Dent J 2004; 196: 395-402.
Kantor M E, Silverman S I, Garfinkel L. Centric-relation recording techniques-a comparative investigation. J Prosthet Dent 1972; 28: 593-600.
Shargill I, Ashley M. Good night, squashbite a how to paper on better wax occlusal records. Dent Update 2006; 33: 626-631.
Ramford S P, Ash M. Occlusion. 4th ed. Philadelphia: W B Saunders Co, 1995.
Wassell R, Naru A, Steele J, Nohl R. Applied Occlusion.Chicago: Quintessence Publishing, 2008.
Davies S, Gray R M. What is occlusion? Br Dent J 2001; 191: 235-245
Davies S J, Gray R M. The examination and recording of the occlusion: why and how. Br Dent J 2001; 191: 291-302.
Whip Mix. Centri-Check System Instructions for Use. 2008. Available at https://www.whipmix.com/wp-content/uploads/2021/08/centri_check_inst.pdf (accessed February 2023).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The author declares no conflicts of interest.
Written consent to publish was obtained from those photographed in Figures 8 and 12.
Rights and permissions
Open Access. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0.© The Author(s) 2023
About this article
Cite this article
Cowan, C. Occlusal records in the production of mounted study casts for tooth wear planning and management. Br Dent J 234, 385–392 (2023). https://doi.org/10.1038/s41415-023-5674-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41415-023-5674-3