Abstract
Here we present a completely new DNA decontamination reagent, DNA-ExitusPlus. In comparison with conventional products, DNA-ExitusPlus guarantees fast and efficient destruction of nucleic acids without corrosive or toxic properties. DNA-ExitusPlus was developed by AppliChem GmbH, Darmstadt, in cooperation with multiBIND biotec GmbH, Dortmund.
Main
The polymerase chain reaction (PCR) has set the standard for DNA amplification technology1, and the rapid extension of PCR technologies has resulted in multiple new applications2,3. The latest protocols and enzyme variants for PCR reactions allow the detection of even single DNA molecules1. One important consequence of the improved sensitivity in DNA amplification is the necessity to avoid any contamination from unwanted external DNA molecules.
The latest research in genetic technology has demonstrated that the presence of free DNA molecules can pose serious problems4,5. Infections, biological transformations or recombination of genomes can be generated by free DNA plasmids or fragments3,4,5,6,7. Changes in viral and bacterial infectivity are observed and are related to the phenomenon of resistance against multiple antibiotics8. As a result, the detection of DNA contamination or prevention of amplification artifacts in PCR experiments is essential for all applications as well as biological containment and safety.
Investigations of the properties of conventional DNA decontamination reagents revealed two major problems. First, none of the reagents studied destroyed DNA molecules efficiently, and second, existing reagents typically contain components with corrosive or even toxic properties. As a consequence, we saw the necessity to develop new solutions for effective DNA decontamination.
DNA decontamination reagents use three different molecular principles for destruction or inactivation of genetic material: modification, denaturation and degradation. Safe DNA decontamination depends on the degradation of DNA into very small fragments. We developed a DNA degradation test to compare conventional decontamination reagents with the new DNA-ExitusPlus. This test allows sensitive quantification of the fragmentation process (Fig. 1).
One surprising result was that some of the conventional reagents are based only on the principles of modification or denaturation. This is revealed by the complete absence of any degraded DNA molecules (Fig. 1). Thus the genetic information is only masked but not destroyed. By chemical demasking reactions the DNA sequences of these molecules would be available and active again. Based on our knowledge about gene technology and the principles of recombination, we concluded that these reagents are no longer appropriate.
However, even reagents that cause degradation of DNA show only limited and partial destruction. Hence, very large DNA fragments containing the complete genetic information still survive treatment. Only DNA-ExitusPlus achieves rapid and efficient degradation.
Another severe disadvantage of conventional reagents is revealed in a test of their corrosive potential. For this purpose different metal plates were incubated with aliquots of the reagents (Fig. 2). This test demonstrates that all currently available products contain aggressive chemicals with corrosive, harmful or even toxic effects. Known ingredients of conventional reagents are azides, mineral acids like phosphoric acid or hydrochloric acid, aggressive peroxides or strong alkaline substances like sodium hydroxide. Therefore, after only 20 min of incubation, irreversible damage of metal surfaces is observed (Fig. 2). The newly developed reagent DNA-ExitusPlus exhibits its unique characteristics especially in this test. For all metal surfaces no corrosion is observed; DNA-ExitusPlus was also tested on many different plastic surfaces without any indication of damage (data not shown). DNA-ExitusPlus offers an efficient, gentle and environmentally safe alternative and proves its superiority to other available decontamination reagents. DNA-ExitusPlus not only degrades and removes all DNA molecules with high efficiency but is neither toxic nor corrosive.
In summary, one observes the following new and unique characteristics: (i) catalytic and cooperative effects guarantee rapid nonenzymatic degradation of nucleic acids, (ii) all components of DNA-ExitusPlus are biodegradable and not harmful or toxic, (iii) no aggressive mineral acids or alkaline substances are used. Equipment and materials are not damaged or corroded even after prolonged incubation
Currently, the most effective method for decontamination appears to be autoclaving. Under standard conditions for autoclaving, DNA molecules are degraded into fragments of 20 to 30 base pairs. However, recent investigations with highly sensitive PCR analysis demonstrate that even after autoclaving larger DNA fragments can persist9. Furthermore, autoclaving can only be used for decontamination of heat-resistant materials and equipment that fit into the autoclave. Decontamination of laboratory benches or larger equipment is impossible.
Efficient degradation of DNA molecules by DNA-ExitusPlus was monitored by PCR analysis (Fig. 3) proving that no amplifiable DNA templates are present. Today, only very different nonstandardized PCR tests are used as controls for successful DNA decontamination. In the case of large DNA control templates, low DNA concentrations and high dilutions in the washing steps, evidence for successful DNA decontamination is very limited. Therefore one has to be very cautious about using a single PCR test as evidence for complete decontamination because such a PCR test would also be negative in the case where DNA is only modified or masked. For complete evaluation of the potential of a DNA decontamination reagent one has to use PCR analysis in combination with a sensitive DNA degradation test.
The tests described here reveal the unique characteristics of DNA-ExitusPlus. These properties offer new opportunities for potential applications in the health sector, the life sciences, medical hygiene, food production and the household. We are convinced that this product defines a new standard for efficient, rapid and gentle DNA decontamination. According to the latest results on biological activities of free DNA molecules, such a product is critical for the new tasks concerning biological containment and safety.
References
Innis, M.A. et al. (eds.) PCR Protocols: A Guide to Methods and Applications (Academic Press, Inc., San Diego, 1990).
Cavalli-Sforza, L.L. The Human Genome Diversity Project: past, present and future. Nat. Rev. Genet. 6, 333–340 (2005).
Tumpey, T.M. et al. Characterization of the reconstructed 1918 Spanish influenza pandemic virus. Science 310, 77–80 (2005).
Burns, P.A. et al. Transformation of mouse skin endothelial cells in vivo by direct application of plasmid DNA encoding the human T24 H-ras oncogene. Oncogene 6, 1973–1978 (1991).
Moniz, M. et al. HPV DNA vaccines. Front. Biosci. 8, d55–d68 (2003).
Gibbs, M.J. et al. Recombination in the hemagglutinin gene of the 1918 “Spanish flu.” Science 293, 1842–1845 (2001).
Kaiser, J. Biocontainment. 1918 flu experiments spark concerns about biosafety. Science 306, 591 (2004).
Guyot, A. et al. Molecular epidemiology of multi-resistant Escherichia coli. J. Hosp. Infect. 43, 39–48 (1999).
Elhafi, G. et al. Microwave or autoclave treatments destroy the infectivity of infectious bronchitis virus and avian pneumovirus but allow detection by reverse transcriptase-polymerase chain reaction. Avian Pathol. 33, 303–306 (2004).
Author information
Authors and Affiliations
Corresponding authors
Additional information
Disclaimer
This article was submitted to Nature Methods by a commercial organization and has not been peer reviewed. Nature Methods takes no responsibility for the accuracy or otherwise of the information provided.
Rights and permissions
About this article
Cite this article
Esser, KH., Marx, W. & Lisowsky, T. DNA decontamination: DNA-ExitusPlus in comparison with conventional reagents. Nat Methods 3, i–ii (2006). https://doi.org/10.1038/nmeth853
Issue Date:
DOI: https://doi.org/10.1038/nmeth853