Sir,
Patients with previous radial keratotomy (RK) have radial incisions of unknown depth, often extending to the limbus, limiting the space for safe placement of a corneal section for phacoemulsification. We report a case of dehiscence of an RK incision during phacoemulsification.
Case report
An 85-year-old male with high myopia presented with a best-corrected visual acuity (BCVA) of 6/36 in either eye. Examination revealed bilateral RK with eight incisions in each eye and significant bilateral lens opacity. The RK, performed 14 years earlier, reduced his myopia (spherical equivalent) from −17.00 to −5.50 D in the right eye and −19.50 to −6.00 D in the left eye. Phacoemulsification in the right eye was carried out through a superior clear corneal section. During phacoemulsification one of the RK incisions adjacent to the section started to dehisce resulting in profuse leak and anterior chamber shallowing. A 10/0 nylon suture perpendicular to the RK incision apposed the gape preventing further extension of the dehiscence (Figure 1). Phacoemulsification was completed without further complication with insertion of a foldable silicone intraocular lens (IOL). In the absence of pre-RK refraction or keratometry, we used the standard Holladay formula with axial length measurements from B-scan ultrasound and keratometry from a Nidek handheld keratometer. The IOL selected was predicted to give a −1.67 D postoperative refraction. Postoperative recovery was uneventful and corneal topography was stable at 2 weeks (Figure 2a) and 10 weeks (Figure 2b) postoperatively. Suture removal was deferred to maintain wound integrity and to limit corneal flattening in the axis of the incision. Myopic degeneration limited the BCVA to 6/12 with a manifest refraction of −0.75 −1.25 × 131 at 3 months after surgery. Uneventful phacoemulsification was carried out using a superior scleral tunnel for the left eye. Insertion of a foldable silicone IOL produced a BCVA of 6/12 with a manifest refraction of −1.75 −1.00 × 26 at 3 months.
Comment
Dehiscence of RK incisions has been previously reported during penetrating keratoplasty, retinal detachment surgery and following blunt trauma.1,2,3,4,5 There has also been a single case report of wound dehiscence during clear corneal cataract surgery 11 months after RK, which necessitated suturing of the keratotomy incision.6 The slow healing of RK incisions is evidenced by clinical reports of late dehiscence, supported by histological findings.7 Our patient developed dehiscence during phacoemulsification 14 years after RK.
The calculation of IOL power in the presence of RK is reported to be inaccurate in the absence of pre-RK keratometry with a high incidence of postoperative central corneal flattening and hyperopic shift.8,9 In our case, pre-RK keratometry was not available at the time of surgery, hence we relied on prephacokeratometry and B-scan axial length measurements using the Holladay for-mula to calculate IOL power. This simple method produced a satisfactory prediction of lens power for both eyes.
Postoperative central corneal flattening and hyperopic shift are reported following cataract surgery, mimicking the changes seen after the initial RK. This is often accompanied by a diurnal variation in vision. It is postulated that both of these phenomena are related to postoperative corneal oedema, which would be more evident on waking. Slow resolution of this hyperopic shift precludes early intervention with lens exchange. As the interval between RK and cataract surgery increases, incision integrity improves and corneal flattening is less evident.8 In our case, the 14-year gap between RK and phacoemulsification might explain the refractive stability demonstrated by postoperative topography.
Cataract surgeons may consider the following to optimise management of cataract patients with previous RK: (1) only use a clear corneal incision if there is sufficient distance between the RK incisions, otherwise consider a scleral tunnel; (2) dehiscence can be managed by suturing of the radial incision; (3) as the interval between RK and cataract surgery increases, improved integrity of the RK incisions may reduce the expected postoperative hyperopic shift.
References
McDonnell PJ . Sight-threatening complications after radial keratotomy. Arch Ophthalmol 1996; 114: 211–213.
Glasgow BJ, Brown HH, Aizuss DH, Mondino BJ, Foos RY . Traumatic dehiscence of incisions seven years after radial keratotomy. Am J Ophthalmol 1988; 106: 703–707.
Vinger PF, Mieler WF, Ostreider JH, Easterbrook M . Ruptured globes following radial and hexagonal keratotomy surgery. Arch Ophthalmol 1996; 114: 129–134.
Peacock LW, Slade SG, Martiz J, Chuang A, Yee RW . Ocular integrity after refractive procedures. Ophthalmology 1997; 104 (7): 1079–1083.
Pinheiro MN, Bryant MR, Tayyanipour R, Nassaralla BA, Wee WR, McDonnell PJ . Corneal integrity after refractive surgery. Ophthalmology 1995; 102 (2): 297–301.
Budak K, Friedman NJ, Koch DD . Dehiscence of a radial keratotomy incision during clear corneal cataract surgery. J Cataract Refract Surg 1998; 24: 278–280.
Binder PS, Nayak SK, Deg JK, Zavala EY, Sugar J . An ultrastructural and histochemical study of long-term wound healing after radial keratotomy. Am J Ophthalmol 1987; 103: 432–440.
Koch DD, Liu JF, Hyde LL, Rock RL, Emery JM . Refractive complications of cataract surgery after radial keratotomy. Am J Ophthalmol 1989; 108: 676–682.
Bardocci A, Lofoco G . Corneal topography and postoperative refraction after cataract phacoemulsification following radial keratotomy. Ophthalmic Surg Lasers 1999; 30 (2): 155–159.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Freeman, M., Kumar, V., Ramanathan, U. et al. Dehiscence of radial keratotomy incision during phacoemulsification. Eye 18, 101–103 (2004). https://doi.org/10.1038/sj.eye.6700526
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.eye.6700526
This article is cited by
-
Lensectomy after radial keratotomy: 1-year follow-up
International Ophthalmology (2019)
-
Ruptured globe 20Â years after radial and transverse keratotomy
International Ophthalmology (2012)
-
Delayed radial keratotomy dehiscence following uneventful phacoemulsification cataract surgery
Eye (2007)