Abstract
Objectives: (1) To develop a scale that is useful in evaluating the accuracy of multifrequency bioelectrical impedance analysis (MF-BIA) in the assessment of body water volumes against the accepted gold standard measurements based on isotope-dilution and total body potassium (TBK). (2) To perform a pilot test of the scale.
Design: A scale was developed to evaluate the accuracy of MF-BIA in the assessment of body water volumes. Questions were obtained from reading the scientific literature and discussions involving the four authors. Three of these and two additional independent readers pre-tested the scale. A weighting was identified for each question and a pilot test with a sample of 10 articles (different to those used for the questionnaire performance) was conducted. A further validation was carried out with a second set of 20 articles and two additional independent readers.
Results: The kappa statistic expressing the level of agreement between pairs of the first three authors using this scale with 10 articles, was 0.3, 0.4 and 0.6 after the first attempt. A second evaluation after specific changes improved the agreement to 0.8, 0.6 and 0.8. The mean score for 10 articles was 252±36 points from a total score of 400 (63±9%). The evaluation with the second set of 20 articles resulted in a κ of 0.7 from two pairs of authors. The evaluation with two additional reviewers resulted in a κ=0.7.
Conclusion: A tool has been developed to assess the accuracy of the MF-BIA technique and to identify methodological components, plan future studies and critically evaluate data in this area. It is likely that this tool may also be used to assess the accuracy of single frequency studies.
Sponsorship: COLCIENCIAS and University of Caldas, Colombia sponsor CH Gonzalez.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Altman DG . 1980 Statistics and ethics in medical research Br. Med. J. 28: 1336–1338
Altman DG . 1991 Practical Statistics for Medical Research London: Chapman and Hall
Altman DG, Gore SM, Gardner MH, Pocock SJ . 1983 Statistical guidelines for contributors to medical journals Br. Med. J. 286: 1489–1493
Armstrong LE, Kenefick RW, Castellani JW, Riebe D, Kavouras SA, Kuznicki JT . 1997 Bioelectrical impedance spectroscopy technique: intra-, extracellular and total body water Med. Sci. Sports Exerc. 29: 1657–1663
Baar J, Tannock I . 1989 Analysing the same data in two ways: a demonstration model to illustrate the reporting and misreporting of clinical trials J. Clin. Oncol. 7: 969–978
Bailar JC, Mosteller F . 1988 Guidelines for statistical reporting in articles for medical journals Ann. Intern. Med. 108: 266–273
Bland JM, Altman DG . 1986 Statistical methods for assessing agreement between two methods of clinical measurement Lancet 8: 307–310
Bland JM, Jones R, Bennet S, Cook DG, Haines AP, Macfarlane AJ . 1985 Is the clinical trial evidence about new drugs statistically adequate? Br. J. Clin. Pharmac. 19: 155–160
Brummer RJM, Bengtsson BA, Bosaeus I . 1992 Validation of body composition determination by bioelectrical impedance analysis in acromegaly Eur. J. Clin. Nutr. 46: 47–52
Chalmers TC, Smith H, Blackburn B, Silverman B, Schroeder B, Reitman D, Ambroz A . 1981 A method for assessing the quality of a randomised control trial Control Clin. Trials 2: 31–49
Chalmers I, Adams M, Dckersin K, Hetherington J, Tarnow-Moedi Q, Meinert C, Tonascia S, Chalmers TC . 1990 A cohort study of summary reports of controlled trials J.A.M.A. 263: 1401–1405
Cho MK, Bero LA . 1994 Instruments for assessing the quality of drug studies published in the medical literature J.A.M.A. 272: 101–104
Cornish BH, Ward LC, Thomas BJ, Jebb SA, Elia M . 1996 Evaluation of multiple frequency-bioelectrical impedance and Cole-Cole analysis for the assessment of water volumes in healthy humans Eur. J. Clin. Nutr. 50: 159–154
Cox R, Soeters PB . 2000 Validation of bio-impedance spectroscopy: effects of degree of obesity and ways of calculating volumes from measured resistance values Int. J. Obes. Relat. Metab. Disord. 24: 271–280
De Lorenzo A, Candeloro N, Andreoli A, Deurenberg P . 1995 Determination of intracellular water by multifrequency bioelectrical impedance Ann. Nutr. Metab. 39: 177–184
Detsky AS, Naylor DC, O'Rourke K, McGeer AJ, L'Abbe KA . 1992 Incorporating variations in the quality of individual randomised trials into meta-analysis J. Clin. Epidemiol. 45: 255–265
Deurenberg P . 1996 Multifrequency-bioelectrical impedance a comparison between the Cole-Cole modelling and Hanai equations with the classical impedance index approach Ann. Hum. Biol. 23: 31–40
Deurenberg P, Westrate I, Paymans I, Koy K . 1988 Factors affecting bioelectrical impedance measurements in humans Eur. J. Clin. Nutr. 42: 1017–1022
Ellis KJ . 1996 Whole-body counting and neutron activation analysis In Human Body Composition, eds. AF Roche, SB Heymsfield & TG Lohman 45–61 Champaign, IL: Human Kinetics
Ellis KJ, Wong WW . 1998 Human hydrometry: comparison of multifrequency bioelectrical impedance with 2H2O and bromide dilution J. Appl. Physiol. 85: 1056–1062
Emerson JD, Colditz GA . 1983 Use of statistical analysis in The New England Journal of Medicine New Engl. J. Med. 309: 709–713
Evans M, Pollock AV . 1985 A score system for evaluating random control clinical trials of prophylaxis of abdominal surgical wound infection Br. J. Surg. 72: 256–260
Forbes GB . 1987 Techniques for estimating body composition In Human Body Composition 5–45 New York: Springer
Gardner MJ, Altman DG, Jones DR, Machin D . 1983 Is the statistical assessment of papers submitted to the British Medical Journal effective? Br. Med. J. Clin. Res. 286: 1485–1488
Gardner MJ, Machin D, Campbell MJ . 1986 Use of checklists in assessing the statistical content of medical studies Br. Med. J. 292: 810–812
Gonzalez C, Evans JA, Smye SW, Holland P . 1999 Variables affecting Bioimpedance analysis measurements of body water Med. Biol. Engng. Comp. 37: 106–107
Goodman SN, Berlin J, Fletcher SW, Fletcher RH . 1994 Manuscript quality before and after peer review and editing at Annals of Internal Medicine Ann. Intern. Med. 121: 11–21
Hannan WJ, Cowen SJ, Plester CE, Fearon KVH, Debeau A . 1995 Comparison of bioelectrical impedance spectroscopy and multifrequency bioimpedance analysis for the assessment of extracellular and total body water in surgical patients Clin. Sci. 89: 651–658
Hardy RJ, Thompson SG . 1998 Detecting and describing heterogeneity in meta-analysis Stat. Med. 17: 841–856
Ho TL, Kushner RF, Schoeller DA, Gudivaka R, Spiegel DM . 1994 Bioelectrical impedance analysis of total body water in haemodialysis patients Kidney Inte. 46: 1438–1442
Hoffer EC, Meador CK, Simpson DC . 1969 Correlation of whole-body impedance with total body water volume J. Appl. Physiol. 27: 531–534
Jebb SA, Elia M . 1993 Techniques for the measurement of body composition: a practical guide Int. J. Obes. Relat. Metab. Disord. 17: 611–621
Jenicek M . 1989 Meta-analysis in medicine. Where we are and where we want to go? J. Clin. Epidemiol. 42: 35–44
Johnson DW, Thomas BJ, Fleming SJ, Westhuyzen J, Moran D, Ward LC . 1996 Monitoring of extracellular and total body water during haemodialysis using multifrequency bioelectrical impedance analysis Kidney Blood Press Res. 19: 94–99
Kelly S, Berry E, Proderick P, Harris KM, Cullingworth J, Gathercole L, Hutton J, Smith MA . 1997 The identification of bias in studies of the diagnostic performance of imaging modalities Br. J. Radiol. 70: 1028–1035
Khan KS, Daya S, Jadad A . 1996 The importance of quality of primary studies in producing unbiased systematic reviews Arch. Intern. Med. 156: 661–666
Kushner RF, Gudivaka R, Schoeller DA . 1996 Clinical characteristics influencing bioelectrical impedance analysis measurements Am. J. Clin. Nutr. 64: 423–427
Lionel NDW, Herxheimer A . 1970 Assessing reports of therapeutic trials Br. Med. J. 3: 637–640
Lykken GI, Lukaski HC, Bolonchuck WW, Sandstead HH . 1983 Potential errors in body composition as estimated by whole body scintillation counting J. Lab. Clin. Med. 4: 651–658
McMaster University Health Sciences Centre . 1981 How to read clinical journals: III. To learn the clinical course and prognosis of disease Can. Med. Assoc. J. 124: 869–872
Moher D, Jadad AR, Nichol G, Penman M, Tugwell P, Walsh S . 1995 Assessing the quality of randomised controlled trials: an annotated bibliography of scales and checklists Control Clin. Trials. 16: 62–73
Moher D, Jadad AR, Tugwell P . 1996 Assessing the quality of randomised controlled trials Int. J. Tech. Assess. Health Care. 12: 195–208
Mulrow CD, Linn WD, Gaul MK, Pugh JA . 1989 Assessing quality of a diagnostic test evaluation J. Gen. Intern. Med. 4: 288–295
National Institutes of Health Technology Assessment Conference Statement . 1994 Bioelectrical impedance analysis in body composition Am. J. Clin. Nutr. 64: 524S–532S
NHS Centre for Reviews and Dissemination . 1996 Undertaking Systematic Reviews of Research on Effectiveness. CRD Guidelines for those Carrying Out or Commissioning Reviews (CRD report no. 4) York: NHS Centre for Reviews and Dissemination, University of York
Oxman AD . 1994 Checklists for review articles Br. Med. J. 309: 648–651
Pullicino E, Coward WA, Elia M . 1992 The potential use of dual frequency bioelectrical impedance in predicting the distribution of total body water in health and disease Clin. Nutr. 11: 69–74
Reisch JS, Tyson JE, Mize G . 1989 Aid to the evaluation of therapeutic studies Paediatrics 84: 815–827
Rochon PA, Gurwitz JH, Cheung CM, Hayes JA, Chalmers TC . 1994 Evaluating the quality of articles published in journal supplements compared with the quality of those published in the parent journal J.A.M.A. 272: 108–113
Schoeller DA . 1996a Bioelectrical impedance analysis for the measurement of human body composition: where do we stand and what is the next step? Nutrition 12: 760–762
Schoeller DA . 1996b Hydrometry In Human Body Composition, eds. AF Roche, SB Heymsfield & TG Lohman 25–44 Champaign, IL: Human Kinetics
Schoeller DA, Kushner RF, Taylor P, Dietz WH, Bandini L . 1985 Measurement of total body water: isotope dilutions techniques In Body Composition Assessment in Youth and Adults: Sixth Ross Conference on Medical Research, ed. AF Roche 124–129 Columbus, OH: Ross Laboratories.
Streiner DL, Norman GR . 1995 From items to scales. In Health Measurement Scales: a Practical Guide to their Development and Use 85–103 Oxford: Oxford University Press
Van Marken Lichtenbelt WD, Snel YEM, Brummer RJM, Koppeschaar HPF . 1997 Deuterium and bromide dilution and bioelectrical impedance spectrometry independently show that growth hormone-deficient adults have an enlarged extracellular water compartment related to intracellular water J. Clin. Endocrinol. Metab. 82: 907–911
Visser M, Deurenberg P, Staveren WA . 1995 Multi-frequency bioelectrical impedance for assessing total body water and extracellular water in elderly subjects Eur. J. Clin. Nutr. 49: 256–266
Westerterp KR, Wouters L, Van Marken Lichtenbelt WD . 1995 The Maastricht protocol for the measurement of body composition and energy expenditure with labeled water Obes. Res. 3: 49–57
Working Group on Recommendations for reporting of clinical Trials in the Biomedical Literature . 1994 Call for comments on a proposal to improve reporting of clinical trials in the biomedical literature Ann. Intern. Med. 121: 894–895
Author information
Authors and Affiliations
Corresponding author
Appendix
Appendix
Rights and permissions
About this article
Cite this article
Gonzalez, C., Evans, J., Smye, S. et al. Total body water measurement using bioelectrical impedance analysis, isotope dilution and total body potassium: a scoring system to facilitate intercomparison. Eur J Clin Nutr 56, 326–337 (2002). https://doi.org/10.1038/sj.ejcn.1601316
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.ejcn.1601316