Commentary

About a decade ago the FDI World Dental Federation initiated a project with the objective to critically appraise the scientific evidence for claims of relationship between characteristics of root formed dental implants and clinical performance.1 In the exhaustive report the authors addressed the prevailing opinion at the time amongst researchers and clinicians that the short implants failed more frequently than the longer implants. Following a critical appraisal of the underlying evidence for this prevailing opinion it was cautioned that: ‘... any demonstrable numerical relationship between two clinical variables in an often extensive and heterogeneous data set may in theory also be due to confounding clinical or patient factors, or it can be just a spurious statistical phenomenon. A prospective study that addresses the influence of implant length on treatment success, preferably randomised and/or blinded, can provide indications as to the extent to which this may be an aetiological factor for implant failure. As no such studies have been carried out, it cannot be ruled out that the reported association between implant lengths and clinical failure is a reflection of anatomical limitations in actual treatment situations. In other words, implant length is a surrogate variable for what actually represents differences in case and site selections in clinical trials.’

Since the 2003 FDI report, six systematic reviews (SRs) have been published about short implants and outcomes,2, 3, 4, 5, 6, 7 supplementing the excellent review paper by Telleman and co-workers.8 Unfortunately, the statement above still holds true in 2011. Not a single study amongst the approximately 150 papers to which the seven SRs refer has been specifically designed to appraise the effects of implant lengths on clinically relevant outcomes. As a consequence, clinicians and investigators are left to struggle with identifying and interpreting any kind of clinical data that contain some element of information about the possible effects of implant length on treatment outcomes. Hence, the potential for bias and opinions based on flawed deductive reasoning is high.

It is unclear why many clinicians routinely use the maximum implant length achievable within the relevant anatomical limitations. Admittedly, laboratory bench-studies have shown that higher pull-out forces may be required for longer implants, but the clinical relevance of such tests is unclear. Two- and three-dimensional photo-elastic studies, finite element analysis and other statistical modeling methods have demonstrated how various levels of compressive and tensile stresses can develop within the implant, the implant:tissue interface and/or in the cortical and trabecular bone. However, these laboratory experiments have failed to elucidate the relationship between occlusal load and the dissipation of forces to the implant:tissue interface in vivo, and whether the stresses achieved are actually detrimental remains elusive from both an internal and external study validity perspective. We simply don't know what is too little or too much stress; only carefully controlled clinical studies in humans can determine this.

Two different primary questions are being addressed in the cited SRs:1, 2, 3, 4, 5, 6, 7, 8 ‘What is the clinical performance of implants shorter than, e.g, ≤7mm2 or ≤9mm?”6,8 and, ‘Do the longer implants demonstrate better clinical performance than the shorter ones, eg, 10mm vs 8.5mm vs 7mm;3 10, 11.5 or 13mm vs 8.5, 8, 7 or 6mm;4 ≥10mm vs <10 vs ≤8mm;5 or ≥10mm vs ≥7 and <10mm?7 The different questions are reflected by the choice and selection of primary studies used for extracting data to answer the questions. While the first question is about prognosis the second is about making comparisons between two or more different interventions. Some will suggest that comparing implant dimensions (including length) may be of interest, while a contrarian opinion will be that it is more relevant to compare the use of short implants versus some form of bone augmentation intervention made necessary by the placement of a longer implant.

Also, the time element that has been considered in the various SRs differs. The three prognosis SRs aim to address: What is the clinical performance of the ≤7mm implants over a minimum of 2 years2 or ≤9mm over a minimum of 1 year?6,8 The comparison SRs seek to answer: Do the longer implants demonstrate better clinical performance than the shorter ones in general,4 alternatively over a minimum of 1 year,3,5 alternatively within the first year of loading.7

The cited SRs1, 2, 3, 4, 5, 6, 7, 8 have extracted data from between 122 and 546 primary studies, and the authors have used different strategies to attempt to quality assure the search for the primary research studies. Some limit the search of bibliographic databases to Medline2, 3, 4, 6 while others include also Embase and/or the Cochrane library.1, 5, 7, 8 Five SRs include data from all study designs1, 2, 3, 4, 6 while three have limited their data extraction to prospective5 or even ‘high quality’/‘methodologically acceptable’7,8 prospective studies. Two SRs limit their focus to partially dentate patients,2,8 while others are limited to only ‘Brånemark-compatible’3 or ‘rough-surface’ implants.5 Moreover, the level of sophistication of the statistical analyses range from applying multivariate logistic regression2 or Mantel-Haenzel-Tests7 to the purely descriptive.1 Outcomes that are analysed are either crude failure rates ignoring the observation time element,2, 3, 5, 7 cumulative survival rates (CSRs),4,6 or as failures per implant exposure time as a basis for estimates of two-year CSR based on a Poisson distribution of adverse events.8 Meta-analyses were applied in one SR to estimate the relative risks of selecting shorter implants5 while another estimated CSRs as a function of several clinical variables, including implant lengths.6 Statistical checks for publication bias was reported in two SRs,5,7 while tests for statistical heterogeneity amongst the primary studies was applied in four SRs.5,6, 7, 8

The introductory quote from the 2003 FDI report1 stated that ‘...any demonstrable numerical relationship between two clinical variables in an often extensive and heterogeneous data set may in theory also be due to confounding clinical or patient factors...’. A striking lack of detail regarding these factors in the primary reports is discussed by all eight SR author groups.1, 2, 3, 4, 5, 6, 7, 8 However, while some author groups chose to simply exclude potentially eligible articles due to lack of information in the reports, other groups made attempts to collect, with more or less success, additional information about methodological content from the original authors of the primary studies.5, 7, 8 The quality of a SR with or without a meta-analysis can never be better than the quality of the primary studies; bluntly stated, this means ‘garbage in, garbage out’. This fact may be the explanation for why some of the SRs following statistical analyses identify some potential confounding clinical co-variables and some do not (Table 1).

Table 1 Systematic reviews2, 3, 4, 5, 6, 7, 8 reporting whether implant length is associated with clinical performance (Yes/No) statistically adjusted or corrected (Yes/No/Not analysed) for clinical variables likely to be considered as study confounders (Discussed)

It is indeed a great challenge to interpret data-sets from methodologically weak clinical studies. Heterogeneous data sets add an additional level of confounding. Under these circumstances it takes courage by an independent clinician or researcher to express an opinion based on the available evidence. It is commendable that most of the authors of the reviews discuss their concerns about internal and external validity of the primary studies. The conclusions of the SRs clearly contrast, and presently it is unknown which one should be regarded as the most trustworthy.

So what clinical practice recommendations can be drawn from the current body of research? No strong recommendations, unfortunately. Short implants seem to be a viable alternative to longer implants as well as to augmentation techniques over a follow-up of about two years. Beyond the first years following implant placement the current scientific data are insufficient for providing clinical guidance. Moreover, no strong prognostic factors associated with an adverse outcome of using short dental implants have been identified – except perhaps as Telleman and co-workers have identified,8 ie, a likely less predictable positive outcome in the maxilla amongst heavy smokers.