Abstract
A measurement system for the relative permittivity of a physiological solution under 50 Hz magnetic fields (MF) is presented. It is based on a phase-sensitive surface plasmon resonance (SPR) system. Relative permittivity was analyzed for different solute concentrations of sodium chloride under various MF exposure parameters. We found that MF exposure at 0.2–4.0 mT step-wise decreased significantly the SPR phase signal of a 0.9% sodium chloride solution while 0.1 mT of MF exposure did not. The decreases in the SPR phase signal depended on the duration of MF exposure and the signal reached a plateau after 15 min of exposure. Interestingly, the decreased SPR phase signal showed a gradual increase and approached the background level when the exposure was drawn off. In addition, we found that the response of the sodium chloride solution to MF also depended on its concentration. In brief, the relative permittivity of sodium chloride in solutions appears to be practically affected by 50 Hz MF exposure. Our data indicates that the relative permittivity of the saline solution influenced by MF exposure should be considered when investigating the biological effects of MF exposure on organisms in experimental study.
Similar content being viewed by others
Introduction
With the development of the electric power industry and wide usage of electronic products, the public concerns have been raised on exposure to increasing electromagnetic fields, especially extremely low frequency magnetic fields (ELF-MF), which range from 1–300 Hz. In 2002, the International Agency for Research on Cancer (IARC) has classified ELF-MF as a possible carcinogen to humans according to limited epidemiological evidences1. It remains inconclusive whether exposure to ELF-MF increases risks of other detrimental health effects2. Moreover, laboratory studies did not clarify the biological effects induced by ELF-MF and their underlying mechanisms3,4,5. The critical issue is that the biophysical mechanisms of ELF-MF acting on organisms are not clear.
Dielectric properties are vital biophysical features of biological tissues and biological activity is an index to assess the active state of tissues. Wang et al. has reported that the dielectric properties of human tissue are related to its biological activities6. The permittivity, which is a vital dielectric property related to the ability to store electric charge, has a great value in various medical areas including electromagnetic protection, electromagnetic imaging and disease diagnosis7,8,9. Thus, it is reasonable that the normal dielectric properties of tissues or cells are important for maintaining their biological function. It is well known that permittivity is related to refractive index. For the saline solution, a non-magnetic material, μr is very close to 1, thus, we can obtain , where εr represents the relative permittivity and n represents the refractive index10,11. To that end, we studied the effects of ELF-MF exposure on refractive index with phase-interrogation surface plasmon resonance (SPR) sensing.
Surface plasmons are free electron oscillations at the metal-dielectric interface and can be optically excited12. SPR sensing is an optical refractive index sensing technology with high sensitivity, label-free and real-time detection13. It has been widely applied in many areas, including proteomics, pharmacy, genomics, pollutants detection and food safety14,15,16,17,18,19,20,21. Conventional SPR sensors are based on amplitude detection and can be classified as intensity-interrogation22, angle-interrogation23 and wavelength-interrogation24. SPR sensors based on phase-interrogation have been extensively studied since the late 1990s, because their resolution is 2 to 3 orders of magnitude higher than that of amplitude-interrogation (10−7–10−8 RIU)10,25,26,27. The change in permittivity of the sample could be reflected by the SPR phase signal change. That means, when the change in SPR phase signal is detected, we can consider that the permittivity of the sample changes. In this study, we have obtained the SPR phase signals of sodium chloride solutions under ELF-MF exposure with various parameters in a phase-interrogation SPR sensing system based on a novel parallel-moving prism phase modulator (PM-PPM). The effects of ELF-MF on sodium chloride solutions with different concentrations have been studied by analyzing the changes in SPR phase signals.
Results
Figure 1 shows the setup of our phase-sensitive SPR sensing system. In this system, a stabilized laser with a wavelength of 671 nm was used as the light source. The light went through a linear polarizer and a beam splitter and was then incident into the PM-PPM, which was equipped with three BK7 rhombic prisms. A mirror was used to reflect the light back into the prism. The modulated light was then filtered with a pin hole to reduce the stray light and struck the SPR sensor at an appropriate angle to meet the resonance condition. The reflected light from the SPR sensor passed through an analyzer and then the interference light was detected by a photo detector. The SPR sensor in the Kretschmann configuration included a homemade microfluidic chip (size: 25.4 × 25.4 mm2) with one reaction chamber and one gold spot and a right angle coupling prism.
Detection Sensitivity
To explore the detection sensitivity of SPR on the refractive index, the SPR signals of different concentrations of sodium chloride solutions were measured at a constant temperature of 25 °C, since it is well known that the refractive index of chloride solution is positively related with concentration. The results showed that the SPR signal was gradually increased following increased concentration (Fig. 2a,b). We also found that the detection limit on the concentration of SPR was lower than 0.01%, suggesting a relatively high sensitivity. SPR phase corresponding to glycerin solutions with various known refractive index values were also detected (Fig. 2c). From this we could see that the sensitivity and resolution of our system were about 1900 rad/RIU and 3.421 × 10−7 RIU (calculated using Equ. (S1) and (S2)). The curve between every two spots in Fig. 2(c) could be seen as a linear line, which could be used to estimate refractive index change of sodium chloride solutions after MF exposure (Supplementary: Table S1).
Study on the Effects of ELF-MF on the Permittivity of Sodium Chloride Solutions
By exploring the effects of ELF-MF on the relative permittivity of sodium chloride solutions, an SPR signal of 0.9% sodium chloride solution, a physiological saline solution, was measured in the presence or absence of 50 Hz MF exposure. The results demonstrated that the SPR phase signal decreased under MF exposure in a time-dependent manner when compared to the control experiment, which did not have MF exposure (Fig. 3a,b). Interestingly, the SPR phase signal reached a constant value after 15 min of MF exposure. Next, we exposed sodium chloride solutions to different exposure intensities of MF for 15 min and measured the SPR signals. We found that MF decreased SPR signals in a dose-dependent manner and MF at as low as 0.2 mT could significantly increase the SPR signal. However, 0.1 mT of MF exposure did not show any significant change (Fig. 3c,d). To evaluate whether MF at 0.1 mT affect the SPR signal for longer exposure durations, we exposed the solution to 0.1 mT MF for a longer time and found that none of the indicated exposure durations successfully affected the signal, indicating that 50 MF with an exposure intensity higher than 0.1 mT is necessary for initiating a response from the SPR signals (Fig. 4a,b). Taken together, these results suggested that MF exposure decreases the permittivity of sodium chloride solutions in a time and dose dependent way. One spot (50 Hz, 4.0 mT, 15 min) of 0.9% sodium chloride solution was chosen to estimate the refractive index change caused by MF exposure. According to the curve between SPR phase signal and refractive index (Fig. 3c), the change was about −3.95 × 10−4 RIU (Supplementary: Table S1).
The Effects of the ELF-MF on Permittivity of Sodium Chloride Solutions is Reversible
We next evaluated if the effects of MF exposure on SPR signals in sodium chloride solutions were reversible. To that end, we exposed the solution to MF at 4.0 mT for 15 min and then had the exposure drawn off. We found that the MF-decreased SPR phase signals began to intensify immediately even only 1 minute after exposure, gradually increased during the recovery time and almost approached the background level (before any MF exposure) after 60 min (Fig. 5a,b). These results indicate that permittivity decreased by MF is reversible.
The Effects of MF on Permittivity is Dependent on Concentration of Solutions
Since the decreases of SPR phase signals of sodium chloride solutions depend on MF exposure duration and dose, we next evaluated whether these effects depend on the solution itself, e.g., the concentrations of the solution. The SPR signals of sodium chloride solutions at 0.09%, 0.3% 0.9% and 3% were examined. The results showed that MF exposure to 0.1 mT for 15 min was able to significantly affect the SPR signals of 3% sodium chloride solutions but not lower concentrations of solutions (Fig. 6a–c). The MF exposure threshold for a SPR signal response of the 0.09% solution was up to 0.4 mT, suggesting that a lower solution concentration of sodium chloride results in a higher responsive threshold of MF exposure (Fig. 6c). In addition, we found that the solution concentration was a critical factor for the amplitude of the decreased SPR signals. The solutions with higher concentration were more responsive to MF under the same exposure parameters (Fig. 6d). Interestingly, we found similar response of human serum to ELF-MF exposure, in which the 50 Hz at 4.0 mT could decrease the amplitude of SPR phase signal (Supplementary: Fig. S1). These results indicate that bodily fluids for organisms might respond to MF differently.
Discussion
In this study we have measured relative permittivities (refractive index) of sodium chloride solutions under 50 Hz magnetic fields based on a phase-sensitive surface plasmon resonance (SPR) system with a high sensitivity of about 1900 rad/RIU and a high resolution of about 3.421 × 10−7 RIU. We have found that SPR phase signals (monotonously related to the relative permittivity) decrease under MF exposure in a time and dose dependent manner and the decreased SPR phase signals were reversible when the exposure was drawn off. Furthermore, the SPR signal responses of sodium chloride solutions depend on the solute concentrations. For 0.9% sodium chloride solution, the refractive index decreased by 3.95 × 10−4 RIU after MF exposure (50 Hz, 4.0 mT, 15 min). Similar to 50 Hz MF exposure, we found that exposure to ELF-MF of other frequency (e.g., 30 Hz and 130 Hz) could decrease SPR phase signals in sodium chloride solutions (Supplementary: Fig. S2). Abbe refractometer was also used to measure the refractive index of 0.9% sodium chloride solution after MF exposure (Supplementary: Fig. S3), which was in good agreement with the results of SPR sensing. However, compared to abbe refractometer, SPR sensing offers higher sensitivity and resolution, which can detect much smaller refractive index change. Our data suggest that the relative permittivity of a saline solution is influenced by MF exposure, which should be considered in experimental studies on the biological effects induced by MF exposure.
It has been reported recently that SPR sensing can be enhanced based on nanomaterials which can modify the sensing substrate or be used as an amplification tag, which can enhance the electric field of the sensing substrate28. With the improvement of the sensitivity, phase-sensitive SPR sensing can be used to monitor the interaction between proteins19 and detect specific molecules with extremely low concentration29.
Methods
Theoretical Analysis
The Kretschmann configuration is used to optically excite SPR in our phase-sensitive SPR system. In the Kretschmann configuration, a 3 nm chromium layer and a 50 nm gold layer are deposited on a BK7 glass slide in sequence, which couples to the bevel of a coupling prism. When total internal reflection (TIR) occurs on the prism/gold interface, an evanescent wave is induced with the wave vector parallel to the interface as
where np represents the refractive index of the coupling prism, θi is the incident angle on the prism/gold interface, wis the angular frequency of the incident light and c is the speed of light. From Maxwell’s equations, the propagation constant of the surface plasmons confined to the interface between the gold and the sample can be deduced as
where εsample and εgold are the dielectric constants of the sample and the gold, respectively.
When kev = ksp, the surface plasmon can be resonantly excited. The reflected p-polarized light suffers a phase jump while the phase of the s-polarized light stays almost unchanged. As a result, a phase difference φspr is created, which is related to the refractive index of the sample in contact with the gold surface. In our system, a parallel-moving prism phase modulator (PM-PPM) is used to extract φspr. In the novel proposed PM-PPM, the phase difference between p-polarized and s-polarized light can be modulated by the TIR in an uncoated rhombic prism. It is apparent to all that TIR occurs on a prism/air interface when the light incident angle θi is larger than the critical angle, which will lead to a different phase shift of p-polarized light and s-polarized light. From the formula of the reflectivity of p-polarized and s-polarized light (i.e., the Fresnel formula), the phase difference φm after m times TIR can be calculated as follows30,31,
where n represents the refractive index of the prism. φp and φs are defined as the phase shifts of p-polarized light and s-polarized light after m times (m counts) of TIR at the incident angle of θi. It is worth noting that φm is determined by the refractive index of the prism, the incident angle and the TIR count. When the refractive index of the prism and the TIR count are fixed, we can achieve different phase difference between p-polarized and s-polarized light by modulating the incident angle. The rhombic prism is quite suitable to be used as a phase difference modulator in phase-sensitive SPR biosensors because of the unique characteristics of the TIR.
The interference intensity between the projection of p-polarized and s-polarized can be described as,
where Ip and Is are the projection intensities of the reflected p-polarized and s-polarized light on the axis of the linear analyzer. By the expansion of the cosine component, the interference intensity can also be written as,
When IA = Ip + Is, and , the interference intensity can be simplified to
The phase of SPR can be extracted by
Three different φmi(i = 1, 2, 3), i.e., φm1 = 0.85π, φm2 = 0.66π and φm3 = 0.40π can be offered by PM-PPM with three prisms fixed on a motor-driven stage in different incident angles and the related Ii (i = 1, 2, 3) can be detected correspondingly. The interference intensity can be written in the form
As a result, the phase of SPR φspr can be extracted after IB and IC are calculated.
MF Exposure System
The ELF-MF exposure system (OX9-1) used in this study was designed and provided by Dr. Bao32. It consists of a “U” type magnet enwrapped in coils, a current amplifier and a central regulator. Once initiated, ELF-MF (e.g., 50 Hz MF) was produced inside the magnet and the central regulator was used to control the intensity and frequency. The control group was conducted under the same conditions but without the ELF-MF exposure.
Statistical Analysis
For each experiment, the value was presented as means ± standard deviation (SD). All computations were performed with SPSS 16.0. The statistical differences between exposed and sham-exposed were tested using the Dunnett’s two-tailed t-test. A probability level of P < 0.05 was considered statistically significant.
Additional Information
How to cite this article: Jiang, L. et al. The effects of magnetic fields exposure on relative permittivity of saline solutions measured by a high resolution SPR system. Sci. Rep. 6, 25111; doi: 10.1038/srep25111 (2016).
References
Repacholi, M. Concern that “EMF” magnetic fields from power lines cause cancer. Sci Total Environ 426, 454–458 (2012).
McNamee, D. A. et al. A literature review: the cardiovascular effects of exposure to extremely low frequency electromagnetic fields. Int Arch Occup Environ Health 82, 919–933 (2009).
Lazzaro, D. V. et al. A consensus panel review of central nervous system effects of the exposure to low-intensity extremely low-frequency magnetic fields. Brain Stimul 6, 469–476 (2013).
Vijayalaxmi & Prihoda, T. J. Genetic damage in mammalian somatic cells exposed to extremely low frequency electro-magnetic fields: a meta-analysis of data from 87 publications (1990–2007). Int J Radiat Biol 85, 196–213 (2009).
Lee, H. C. et al. Effect of extremely low frequency magnetic fields on cell proliferation and gene expression. Bioelectromagnetics 36, 506–516 (2015).
Wang, H. et al. Correlation between the dielectric properties and biological activities of human ex vivo hepatic tissue. Phys Med Biol 60, 2603–2617 (2015).
Funk, R. H., Monsees, T. & Ozkucur, N. Electromagnetic effects - From cell biology to medicine. Prog Histochem Cytochem 43, 177–264 (2009).
Halter, R. J., Hartov, A. & Paulsen, K. D. A broadband high-frequency electrical impedance tomography system for breast imaging. IEEE Trans Biomed Eng 55, 650–659 (2008).
Laufer, S., Ivorra, A., Reuter, V. E., Rubinsky, B. & Solomon, S. B. Electrical impedance characterization of normal and cancerous human hepatic tissue. Physiol Meas 31, 995–1009 (2010).
Nelson, S. G., Johnston, K. S. & Yee, S. S. High sensitivity surface plasmon resonance sensor based on phase detection. Sens Actuators, B 35, 187–191 (1996).
Abdulhalim, I., Zourob, M. & Lakhtakia A. Surface plasmon resonance for biosensing: a mini-review. Electromagnetics 28, 214–242 (2008).
Homola, J. Surface plasmon resonance sensors for detection of chemical and biological species. Chem Rev 108, 462–493 (2008).
Schasfoort, R. B. & Ma, A. J. T. Handbook of Surface Plasmon Resonance. Royal Society of Chemistry, doi: 10. 1039/9781847558220 (2008).
Majka, J. & Speck, C. Analysis of protein-DNA interactions using surface plasmon resonance. Analytics of Protein-DNA Interactions 104, 13–36 (2007).
Teh, H. F., Peh, W. Y., Su, X. D. & Thomsen, J. S. Characterization of protein–DNA interactions using surface plasmon resonance spectroscopy with various assay schemes. Biochemistry 46, 2127–2135 (2007).
Baron, O. L., Pauron, D. & Antipolis, S. Protein-lipid interaction analysis by surface plasmon resoance (SPR). Bio-Protocol 4, 1–8 (2014).
Zijlstra, P., Paulo, P. M. & Orrit, M. Optical detection of single non-absorbing molecules using the surface plasmon resonance of a gold nanorod. Nat Nanotechnol 7, 379–382 (2012).
Jin, W. et al. A DNA sensor based on surface plasmon resonance for apoptosis-associated genes detection. Biosens Bioelectron 24, 1266–1269 (2009).
Law, W. C., Yong, K. T., Baev, A. & Prasad, P. N. Sensitivity improved surface plasmon resonance biosensor for cancer biomarker detection based on plasmonic enhancement. ACS Nano 5, 4858–4864 (2011).
Goodrich, T. T., Lee, H. J. & Corn, R. M. Direct detection of genomic DNA by enzymatically amplified SPR imaging measurements of RNA microarrays. J Am Chem Soc 126, 4086–4087 (2004).
Shumaker-Parry, J. S., Aebersold, R. & Campbell, C. T. Parallel, quantitative measurement of protein binding to a 120-element double-stranded DNA array in real time using surface plasmon resonance microscopy. Anal Chem 76, 2071–2082 (2004).
Manuel, M., Vidal, B., Lopez, R., Alegret, S. & Chamarro, J. A. Determination of Probable Alcohol Yield in Musts by Means of an Spr Optical Sensor. Sens Actuators, B 11, 455–459 (1993).
Liedberg, B. & Lundstrom, I. Principle of biosensing with an extended coupling matrix and surface plasmon resonance. Sens Actuators, B 11, 63–72 (1993).
Jorgenson, R. & Yee, S. S. A fiber-optic chemical sensor based on surface plasmon resonance. Sens Actuators, B 12, 213–220 (1993).
Wong, C. L. et al. Real-time protein biosensor arrays based on surface plasmon resonance differential phase imaging. Biosens Bioelectron 24, 606–612 (2008).
Law, W. C. et al. Wide dynamic range phase-sensitive surface plasmon resonance biosensor based on measuring the modulation harmonics. Biosens Bioelectron 23, 627–632 (2007).
Zeng, S. W. et al. Size dependence of Au NP-enhanced surface plasmon resonance based on differential phase measurement. Sens Actuators, B 176, 1128–1133 (2013).
Zeng, S. W., Baillargeat, D., Ho, H. P. & Yong, K. T. Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing application. Chem. Soc. Rev. 43, 3246–3452 (2014).
Zeng, S. W. et al. Graphene-gold metasurface architectures for ultrasensitive plasmonic sensing. Adv. Mater. 27, 6163–6169 (2015).
Ye, G. A., Yang, W., Jiang, L. & He, S. L. Surface Plasmon Resonance Phase-Sensitive Imaging (SPR-PI) Sensor Based on a Novel Prism Phase Modulator. PIER 145, 309–318 (2014).
Ye, G. A., Yang, W., Jiang, L., Qian, J. & He, S. L. A novel phase-sensitive SPR biosensor array based on prism phase modulator. Smart Photonic and Optoelectronic Integrated Circuits Xvi8989 (2014).
Wang, S., Bao, J. L. & Zhu, C. Y. Development of Real-time Electromagnetic Field Exposure System for Cell. High Voltage Engineering 41, 1409–1416 (2015).
Acknowledgements
We are grateful to Dr. JialiBao for assistance on the ELF-MF exposure system. This study was supported by grants from the Ministry of Science and Technology (2011CB503702), the Science and Technology Department of Zhejiang Province (2010R50007) and the National Natural Science Foundation of China (81573109).
Author information
Authors and Affiliations
Contributions
L.J. and X.Z. generated the experimental idea. L.J. set up the SPR system and completed the optical experiments. J.T. used the abbe refractometer to measure the refractive index. X.Z. analyzed the statistics. L.J., X.Z., Y.F. and D.Y. contributed in writing manuscript text. J.Q., G.C. and S.H. discussed the design of the structure and experimental results, as well as contributed in manuscript revise. S.H. finalized the manuscript.
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Electronic supplementary material
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Jiang, L., Zhao, X., Fei, Y. et al. The effects of magnetic fields exposure on relative permittivity of saline solutions measured by a high resolution SPR system. Sci Rep 6, 25111 (2016). https://doi.org/10.1038/srep25111
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/srep25111
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.