Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Cerumenogram: a new frontier in cancer diagnosis in humans

Abstract

Cancer is the deadliest human disease and the development of new diagnosis methods is important to increase the chances of a cure. In this work it was developed a new method, named here for the first time as cerumenogram, using cerumen (earwax) as a new biomatrix for diagnosis. Earwax samples collected from cancer patients (cancer group) and cancer-free patients (control group) were analyzed by Headspace/Gas Chromatography-Mass Spectrometry (HS/GC-MS), following with multivariate analysis steps to process the raw data generated. In total, 158 volatile organic metabolites (VOMs) were identified in the cerumen samples. The 27 selected as potential VOMs biomarkers for cancer provided 100% discrimination between the cancer and control groups. This new test can thus be routinely employed for cancer diagnoses that is non-invasive, fast, cheap, and highly accurate.

Introduction

Cancer is a disease characterized by the uncontrollable rise of abnormal cells in the body that extend through organs and tissues and can spread all over an organism. One in three sudden deaths from non-communicable diseases is due to cancer1. The International Agency for Research on Cancer (IARC) estimated that there will be 18.1 million new cancer cases and 9.6 million cancer deaths in 2018 across 20 world regions2. Cancer incidences in humans are attributed to many factors, such as age, lifestyle behavior, hormones, and the exposure to environmental carcinogens3,4. Due to the many factors responsible for cancer diseases, and its huge ratio of incidence and mortality, early cancer diagnoses are urgently needed.

In a clinical routine, many conventional diagnostics tests depend on the suspected type of cancer in the patient, which include cytology, biopsy, blood tests, and physical exam. These tests are limited and often use painful and invasive methods; moreover, some types of cancer are not detected due the limitations of the tests. The existing non-invasive methods such as computed tomography (CT) and magnetic resonance imaging (MRI), are associated with high false-positive rates and harmful for patients, due to the risk of radiation exposure5.

Alternative approaches to these traditional diagnostics tools have been developed involving screening biomarkers in biological samples (biomatrices) using analytical methods. However, the search for biomarkers to develop a clinical diagnosis in early stages are widely associated with an invasive biomatrix, such as serum tests6,7,8 and clinical tumor samples9,10,11.

Many researchers in the bioanalytical field have focused attention on the development of new non-invasive techniques for cancer diagnoses12, which has led to the study of volatile organic metabolites (VOMs) present in human and animals biomatrices, as biomarkers for a wide range of diseases13,14. VOMs are a part of the metabolomics field that can also reflect the status of the body, and serve as a potential alternative to diagnose several diseases, because they can provide tests that are non-invasive, painless, cheap, fast, and easy15. VOMs are thermostable molecules that extend to a vast class of chemical compounds with a boiling point that goes from <0 °C (e.g. methane) to about 250 °C (e.g. limonene)14,16. VOMs are produced mainly for specific routes of a biochemical pathway (endogenous VOMs), or by exposure to an exogenous source (exogenous VOMs).

Endogenous VOMs are the aim in the studies to develop new diagnoses, because they are produced by reactive oxygen species (ROS) and free radicals excreted from the mitochondria in an oxidative stress process. ROS and liberated free radical attack many cellular structures (including RNA and DNA), and when accumulated in tissues, ROS destroys many different molecules, generating a wide range of VOMs classes14. ROS production is associated with the most inflammatory condition in cells, such as cancer diseases; therefore, ROS products are manifested at different levels in abnormal cell conditions and are accumulated in several biomatrices, such as urine, feces, sweat, tears, saliva, breath, and cerumen15,17,18.

Moreover, in the early stages of cancer, cancerous cells proliferate rapidly; consequently, adenosine monophosphate (AMP)-activated protein kinase is activated to accelerate the breakdown of lipids, for energy production to meet the energy requirement of cell proliferation and thus change the VOMs composition in body fluids19. Several studies have been conducted in recent years exploring the use of VOMs as biomarkers to identify cancer.

For this purpose, some diagnostic exams for cancer using blood, saliva, breath, fecal extract, and urine have been tested20,21,22,23,24, with some disadvantages such as affected by nutritional factors; low quantity and liability to diurnal variations of the VOMs composition; discriminations for polar or nonpolar VOMs depending on the polarity of the biomatrix; require time consuming pre-concentration steps; and effect of pH on composition25.

Nevertheless, despite the advantages of cerumen in relation to other biomatrices, such as no need for sample preparation, easy collect (painless), and less liability to external contamination (due to the location inside the auditory canal)25, it has been a neglected body secretion. Although cerumen is a concentrated form of excretion of polar and nonpolar metabolites, suitable for tracking long-term changes26. Only recently, has cerumen been used as a source of information about race, ethnicity and gender for individuals from East Asian, African, and Caucasian descent27,28. Recently, our research group successfully used cerumen VOMs to diagnose diabetes mellitus (DM) and differentiate between DM type I and II29. We have also investigated the viability of cerumen to diagnose intoxications and metabolic alterations in animals25,30, as well as for forensic applications as a monitoring biomatrix for drug abuse analysis31.

However, to date, cerumen has never been tested with the purpose of identifying and selecting potential volatile biomarkers for cancer. Thus, our work purposes the use of cerumen as a new biomatrix to diagnosis cancer in a new method named here, for the first time, as cerumenogram, with the principal objective to increase the accessibility to an accurate cancer diagnosis test, improving the chances of a cure. This identification is extremely important to advance the frontier for the development of new clinical diagnosis methods, allowing identification of cancer in a fast and conclusive way, using a non-invasive and easily collected biomatrix rich in both polar and nonpolar components. Thus, using Headspace/Gas Chromatography-Mass Spectrometry (HS/GC-MS) - a common technique found in many analytical laboratories around the world - analysis of cerumen volatile compounds, cerumenogram emerges as a new approach for cancer diagnosis.

Results

We collected samples from healthy subjects (control group) and a cancer group within different ranges of first cancer diagnostic. The cancer patients were either in early (0–6 months), medium (6–12 months), and later (between 1 and 5 years or more) intervals of diagnostic. The cancer patients had been diagnosed with either Lymphoma (n = 11), Carcinoma (n = 28) or Leukemia (n = 13). Cancer samples were collected from individuals that have been in cancer treatment (chemotherapy, radiotherapy or both), and from patients that have not received any type of cancer treatment. Information about the date of samples’ collection, order of analysis and type of cancer of each sample is provided in the Supplementary Table 1 (Table S1). In addition, all information collected about the subjects from all groups in this study is summarized in Supplementary Table 2 (Table S2).

Cerumen VOMs profile

The 102 cerumen samples collected from the cancer (n = 52) and control group (n = 50, healthy subjects, cancer free), were analyzed by HS/GC-MS. The 158 VOMs identified including organooxygen, carboxylic acids, organosulfur, hydrocarbons, and organonitrogen compounds. These compounds are summarized in Table S3 enumerate by the sequence of elution, absolute, and relative to the Internal Standard (IS) retention time. The fingerprint signals, of cerumen metabolomic profile, from GC-MS Total Ion Chromatograms (TIC) of the cancer group (divided into Carcinoma, Lymphoma, and Leukemia) contrasted with the control group are shown in Supplementary Fig. 1 (Fig. S1), where a wide range of compounds were identified, and the different TIC profile for each group is notable. Among the 158 VOMs, the largest group was the ketones with 36 compounds; followed by 24 hydrocarbons; 17 amines and amides derivatives; 14 esters and/or ethers; 14 aldehydes; 14 carboxylic acid; 13 furanic, lactones, and derivatives; 13 alcohols and derivatives; 8 pyran; 3 organosulfur; and 2 epoxides/oxabicyclo compounds.

Statistical analysis

Using the data matrix of the 158 VOMs identified, we run a Hierarchical Cluster Analysis (HCA) labelling ethnicity/race as parameters and, as shown in Supplementary Fig. 2 (Fig. S2), there is no ethnicity/race effect on cerumen’s VOMs expression. Since the ethnicity/racial of the individuals has low influence in the types of the VOMs produced in cerumen, but influencing only in the VOMs concentration27,28, it was applied the binary model (VOMs absence/presence) aiming to avoid the effect of this factor in cancer detection. Besides that, the influence of gender on VOMs produced in cerumen was verified using gender’s parameters in the HCA. As shown in Supplementary Figs 3 and 4 (Figs S3 and S4), also cerumen samples from males and females are not discriminated by its VOMs profile. Thus, a binary model was constructed aiming to visualize and explore similarities and dissimilarities in the data. In this model, we utilized a Genetic Algorithm for a Partial Least Squares regression (GA-PLS) to select the most informative VOMs. This method is commonly used in very large data matrices and produces good improvement of the data32. In this case, the GA-PLS selected 27 out of 158 VOMs identified in cerumen analysis as a fingerprint for cancer diagnoses: 3 ketones; 3 ester and/or ether compounds; 1 aldehyde; 4 pyran compounds; 2 furanic, lactones, and derivatives; 1 epoxides/oxabicyclo; 3 hydrocarbons; 3 carboxylic acid; 3 alcohols and derivatives; 3 amines and amides derivatives; and 1 organosulfur compound.

Using these 27 selected VOMs, we run a HCA and observed that all samples were correctly discriminated between cancer and control group, as shown in circular dendrogram in Fig. 1. However, there was no separation between the cancer types analyzed (Carcinoma, Lymphoma, and Leukemia), or between the type of treatment that the patients were previous submitted. Moreover, to verify the effect of the gender in the cancer samples discrimination, we run a HCA using these 27 potential biomarkers to observe any type of over-classification by gender on cancer identification. As shown in the Supplementary Figs 5 and 6 (Figs S5 and S6), there is no gender discrimination in the samples by these 27 cerumen VOMs profile, and the only factor in the discrimination of the samples according to the current cerumen/VOMs biomarkers data is cancer. These results indicate that the 27 VOMs selected by GA-PLS are promising biomarkers in cerumen for cancer diseases since the discrimination pattern shown in Fig. 1 is an excellent result when considering that the data set is of intermediate size. The 27 VOMs selected are shown in Table S4 with their respective chemical structure.

Figure 1
figure1

Circular dendrogram of the 102 cerumen samples using the 27 VOMs peak signals selected by GA-PLS from the 158 VOMs analyzed by HS/GC-MS. The circular dendrogram illustrates successful separation between the samples from the control (blue number) and cancer groups (red number). Samples from patients with different types of cancer are represented by different colors, and the oncological treatments are represented by different geometric symbols. Numbers on the branches in the HCA correspond to the order of samples analysis.

Discussion

The cerumen analysis provides a TIC with many peaks and different profiles for each cancer type leading to the identification of a wide range of compounds (Fig. S1). A previous compendium published in 2014 presented the VOMs composition of breath, saliva, blood, milk, skin secretions, feces, and urine, but cerumen was not included mainly due to the lack of studies that explore this biomatrix33. However, the cerumenogram can identify 158 VOMs, which is an excellent number of compounds compared to 130 found in urine34 and 120 in saliva of humans35, using the same analytical technique, GC-MS. Therefore, cerumen is a potential source of biomarkers for many metabolomic changes, due to the wide variety of VOMs.

Using the binary data approach, 27 VOMs were selected by GA-PLS, which are 2,5-Dihydrofuran (VOM 3), 2-Butanone (VOM 5), 2-Methyl-3-buten-2-ol (VOM 6), 3-Methylhexane (VOM 10), 2-Pentanone (VOM 11), 1-Methylcyclooctene (VOM 40), 6-Methyl-7-oxabicyclo[4.1.0]heptan-2-one (VOM 42), 5-Ethyldihydro-2(3 H)-furanone (VOM 43), 6-Methyltetrahydro-2H-pyran-2-one (VOM 47), 2,5-Dimethylaniline (VOM 58), 1-Decanol (VOM 59), 6-Propyltetrahydro-2H-pyran-2-one (VOM 72), 6-Butyltetrahydro-2H-pyran-2-one (VOM 85), 3-Phenylthiophene (VOM 88), N-(3-Acetylphenyl)acetamide (VOM 99), 2,3-Dimethylquinoline (VOM 102), 1-Dodecanol (VOM 103), Dodecanoic acid (VOM 105), 1-(Decyloxy)decane (VOM 120), Eicosane (VOM 126), 6-Heptyltetrahydro-2H-pyran-2-one (VOM 128), n-Tetradecanoic acid (VOM 130), 7-Octadecanone (VOM 134), n-Octadecanoic acid (VOM 141), n-Octadecanal (VOM 142), Diisobutyl phthalate (VOM 147), and Bis(2-ethylhexyl) phthalate (VOM 157).

These data set were submitted in multivariate analysis, HCA, to visualize if the samples from cancer and control group could be discriminated. Precisely, these 27 compounds demonstrated a 100% accurate discrimination between cancer and control group samples (Fig. 1). These produced VOMs are distinct in each organism due to the cell process of cancer development in the human organism, which includes tumor-promotion inflammation and genome instability and mutation17,36. However, even in these different clinical cases of the patients in the cancer group, such as treatment and cancer type, these 27 VOMs selected by GA-PLS successfully discriminate all samples from cancer and control group without over-classification by ethnicity/race or gender, and they are definitely potential cancer biomarkers in cerumen.

To construct a database with a large number of individuals in healthy and cancer conditions, all variables selected by GA-PLS were maintained, although some variables, such as 1-Methylcyclooctene (VOM 40), 2,5-Dimethylaniline (VOM 58), 1-Decanol (VOM 59), 3-Phenylthiophene (VOM 88), and 1-Dodecanol (VOM 103) (Table S3), are not important for the discrimination process, and their exclusion does not change the discrimination obtained by the model until. The 1-Methylcyclooctene (VOM 40), 2,5-Dimethylaniline (VOM 58), 1-Decanol (VOM 59), 3-Phenylthiophene (VOM 88), and 1-Dodecanol (VOM 103) selected by GA-PLS are not discussed here since they are not important for discriminating the samples by multivariate analysis, but metabolites 5-Butyldihydro-2(3 H)-furanone (VOM 69) and n-Nonadecanoic acid (VOM 145) are discussed to emphasize their changes in the frequency of occurrence between cancer and control group, although they were not selected by GA-PLS. These 27 biomarkers selected by GA-PLS are from different organic class, such as organooxygen (ketones, aldehydes, furans, esters and ethers, pyrans, epoxides, and alcohols), organic acids (carboxylic acids), organonitrogen (amines and amides derivatives), organosulfur (dialkyldisulfides and thioethers), and hydrocarbons (alkanes, alkenes, benzene, and substituted derivative). Some of them are associated for the first time as expression of cancer cells.

Among the polar VOMs, the most numerous class found in cerumen were the ketones. The ketones are abundantly found in urine, breath, saliva, and tissue samples34,35,37,38. These compounds are produced in the human organism from many different metabolic pathways, mainly endogenous decarboxylation of acetyl-CoA, β-oxidation of fatty acids, and exogenous pathways (air contaminants, diet, smoking). The increase of some ketone bodies in the organism were associated with the growth of cancer cells36,39,40. As seen in Table S4, in our analysis the GA-PLS selected three ketones as cancer biomarkers in cerumen: 2-Butanone, 2-Pentanone, and 7-Octadecanone.

The 2-Butanone (VOM 5) was found in 96.2% in cancer samples, while in the control group it was found in 58% samples (38.2% difference) (Table S3). This biomarker was already detected in abnormal concentration in feces of adults with Crohn’s disease41, in the saliva of children with celiac disease42, and in the urinary profile of breast cancer patients43. Another ketone biomarker in cerumen, 2-Pentanone (VOM 11), when found in high levels in feces, has been associated with inflammatory bowel diseases44. In addition, 7-Octadecanone (VOM 134), a ketone of high molecular weight, was selected as a cancer biomarker in this biomatrix; however, this is the first time that this compound has been associated with some pathology.

In addition to the polar VOMs identified here, fourteen aldehydes were detected in cerumen analysis. Several sources, exogenous and endogenous, are responsible for a presence of aldehydes in an organism. In endogenous pathways, these carbonyl compounds arise in the body, mainly by a mechanism involving process of metabolized alcohols and reduction of hydroperoxide by cytochrome P450 as a secondary product of lipid peroxidation. For the exogenous route, tobacco smoke, the products utilized in detoxification process of tobacco, and dietary lifestyle are the main sources of aldehydes in the body14. Aldehydes are also commonly found in the urinary biosignature34, salivary profile35, and in gastric tissue samples38.

Among fourteen aldehydes identified here, only one, n-Octadecanal (VOM 142), was selected by GA-PLS as a cancer biomarker. The n-Octadecanal has been found in the plasma of patients with Sjogren-Larsson syndrome (SLS) and can also be found in feces from healthy subjects45,46. However, this is the first time that n-Octadecanal has been associated with cancer diseases.

Some cyclic compounds containing oxygen as a heteroatom, such as furanic, lactones, and derivatives, were identified in our analysis. In the human organism, these compounds are produced by the dehydration of monosaccharides, also as a result of the catalysis reaction of fatty acid oxidation by lipoxygenases47. The VOMs formed by the fatty acid peroxidation maybe liberated as a consequence of oxidative stress into the inflammatory cells by general blood circulation48. Otherwise, studies have suggested that these compounds have higher production in patients with colorectal cancer than in healthy individuals47, and high levels of these compounds are also associated with breast and lung cancer43,49.

The GA-PLS selected two furanic compounds as cancer biomarkers: 2,5-Dihydrofuran (VOM 3) and 5-Ethyldihydro-2(3 H)-furanone (VOM 43). The 5-Butyldihydro-2(3 H)-furanone (VOM 69) was not selected by GA-PLS; however, it seems to be a very important VOM due to its presence in 40% more samples from the cancer group than the control group (Table S3). This is the first time that 2,5-Dihydrofuran (VOM 3) has been associated with cancer diseases. In addition, the other furanic derivative compound selected as cancer biomarker in cerumen, 5-Ethyldihydro-2(3 H)-furanone (VOM 43), when presents in abnormal levels in feces, has been correlated with some gastrointestinal diseases, such as Campylobacter jejuni infection50.

Esters and ethers are commonly found in cerumen due to the formation processing of this biomatrix. Cerumen is formed by the combination of ceruminous glands with sebaceous glands, resulting in a mixture of fatty material and sweat secretions51. Thus, cerumen contains many heavy molecular weight compounds, such as wax esters, triacyclglycerols, and cholesterol52,53. In our bioanalytical analysis, we identified fourteen ester and ether compounds, and among them, three were selected as cancer biomarkers: 1-(Decyloxy)decane (VOM 120), Diisobutyl phthalate (VOM 147), and Bis(2-ethylhexyl) phthalate (VOM 157). This is the first time that these compounds have been indicated as biomarkers for cancer diseases. On the other hand, the phthalate compounds are known endocrine disruptors, dermal adsorption and urine secretions of these compounds has been widely study54,55.

In addition, the two-last classes of heterocyclic compounds, with oxygen as a heteroatom, found in cerumen samples were the Pyran and the Epoxide/Oxabicyclo compounds. We detected in cerumen samples eight Pyran and two Epoxide/Oxabicyclo compounds. The GA-PLS selected four Pyran compounds as cancer biomarkers: 6-Methyltetrahydro-2H-pyran-2-one (VOM 47), 6-Propyltetrahydro-2H-pyran-2-one (VOM 72), 6-Butyltetrahydro-2H-pyran-2-one (VOM 85), and 6-Heptyltetrahydro-2H-pyran-2-one (VOM 128). In addition, one Epoxide/Oxabicyclo compound was selected: 6-Methyl-7-oxabicyclo[4.1.0]heptan-2-one (VOM 42).

However, only 6-Methyltetrahydro-2H-pyran-2-one has already been detected in abnormal conditions in feces of patients with colorectal cancer56. The other three Pyran compounds related here are being described as cancer biomarkers for the first time. The epoxide compounds are produced in the human organism by the isoprene metabolization in liver microsomes by cytochrome P450 (CYP2E1 and CYPB6) to mono and di-epoxides compounds57,58. The Epoxide selected here as cancer biomarker in cerumen is also being related for the first time as an expression of cancer cells.

The analysis of cerumen identified thirteen alcohols and derivatives. Alcohols have exogenous and endogenous routes that can explain their presence in the human organism. In the endogenous ways, alcohols are a secondary product of lipid peroxidation, and low-weight alcohols are produced in pyruvate metabolism by intestinal bacteria37,59. For the exogenous routes, alcohols are release in the gastrointestinal tract into the blood, following enzyme metabolization (such as alcohol dehydrogenases), concomitantly with the reduction of nicotinamide adenine dinucleotide (NAD+ to NADH), and by cytochrome P450 (CYP2E1)14.

Alcohols have many routes of body-scape, mainly through urine, sweat, feces, breath, saliva, and breast milk17. Three alcohols were selected by GA-PLS as cancer biomarker in cerumen: 2-Methyl-3-buten-2-ol (VOM 6), 1-Decanol (VOM 59), and 1-Dodecanol (VOM 103). However, the 1-Decanol only appeared in 10% of the control samples, while this compound was not found in the cancer group (Table S3). The 1-Dodecanol only changed 0.6% between cancer and control group (Table S3). The 2-Methyl-3-buten-2-ol was the main biomarker found in this class, and it is being reported here as a cancer biomarker for the first time.

We identified fourteen carboxylic acids in the cerumen biomatrix. Carboxylic acids are produced in the organism and mainly released through oxidation of cytotoxic aldehydes dehydrogenase (ALDH) enzymes60. Studies identify volatile organic acids as important intermediates in different biological processes usually due to bacterial activity, such as degradation of carbohydrates in the intestine by bacterial anaerobic process61. These organic compounds are commonly found in urine34, saliva35, and human tissue38.

This analysis separated three organic acids as cancer biomarker in cerumen by GA-PLS. They are Dodecanoic acid (VOM 105), n-Tetradecanoic acid (VOM 130), n-Octadecanoic acid (VOM 141). The n-Nonadecanoic acid (VOM 145) was not selected by GA-PLS; however, this compound appears 53.4% more in cancer group than in control group samples (Table S3). These compounds, when present in abnormal concentration in many biomatrices, are widely associated with advanced or immature cancer pathology. Dodecanoic acid (VOM 105) has been found at high levels in saliva of patients with oral squamous cell carcinoma (OSCC), in patients with oral leukemia (OLK)62, colorectal patients56, and patients with metastatic melanoma63.

The n-Tetradecanoic acid (VOM 130), when detected in high levels in urine, has been associated with OLK and OSCC62, and detected in abnormal concentration in blood samples for an oesophageal cancer group64, and in feces and urine of colorectal patients65,66. In addition, high levels of n-Octadecanoic acid (VOM 141) has already been associated as a biomarker for breast cancer in blood analysis67, and in feces for colorectal cancer24. Finally, the n-Nonadecanoic acid (VOM 145) has also been detected in high levels in feces of patients with colorectal cancer68.

We have identified seventeen organic compounds in cerumen that has nitrogen as a heteroatom. Organonitrogen compounds, such as pyrrole, pyridine, amides, and derivatives were found in cerumen, and they can be related as natural products of the organism or associated to pollutants of exogenous sources (e.g. diet, air pollution, and cigarette smoke)69,70. Furthermore, some higher volatile organonitrogen emission from tissue samples have been associated with gastric, and lung tissue cancer38,71. In this analysis, three organonitrogen compounds were selected by GA-PLS as a cancer biomarker in cerumen: 2.5-Dimethylaniline (VOM 58), N-(3-Acetylphenyl)acetamide (VOM 99), and 2,3-Dimethylquinoline (VOM 102). This is the first time that these compounds have been found as an expression of some pathology.

The incomplete metabolism of cysteine and methionine by the transamination pathway are responsible for the expression of volatile organosulfur72. We detected three organosulfur compounds in the cerumen samples, among them, the Dimethyl disulfide (VOM 16), which was produced through the oxidation of methanethiol, also by gram-negative bacteria72,73. Interestingly, Dimethyl disulfide (VOM 16) has been detected as a potential cancer biomarker in many biomatrices, especially urine49, but in cerumen was not selected as a cancer biomarker. In cerumen only the 3-Phenylthiophene (VOM 88), of this class, was selected as a biomarker by GA-PLS; however, this compound is present only 2.5% more in cancer than in control group samples (Table S3).

We detected twenty-four hydrocarbons, the second most present class in cerumen samples. Many production routs of hydrocarbons have been connected to the presence of reactive oxygen species, due to oxygen free radicals that probably escape from mitochondria into a cytoplasm37. This analysis selected three hydrocarbons as cancer biomarkers: 3-Methylhexane (VOM 10), 1-Methylcyclooctene (VOM 40), and Eicosane (VOM 126). Eicosane, which was probably produced by peroxidation of polyunsaturated fatty acids (PUFAs), e.g. linoleic acid, present in the cell membrane74, has already been detected in saliva and feces of healthy subjects33,75. In addition, 3-Methylhexane, a result of peroxidation of PUFAs76, is related for the first time in the human organism. Thus, these hydrocarbons are found exclusively in cerumen as valuable cancer biomarkers.

In summary, we developed a new analytic approach to identify cancer in humans with some advances to another methods. The main merits of cerumen sampling over other non-invasive biomatrix include easy sample collection, painless and no discomfort or embarrassment associated with other biomatrices (such as blood, urine, and feces tests), no need for treatment or preconcentration of the sample, less inclined to contamination, and not liable to blood contamination of samples25.

In addition, cerumen was the first biomatrices to achieve a 100% efficiency in the discrimination between samples from cancer and control group, and the only limitation is the inability to discriminate between cancer types that would require further specific screening process77,78. However, it is worth emphasizing that, given its high reliability, accuracy, simplicity, and low cost, this test for cancer and other diseases using cerumen – here called for the first time as Cerumenogram – could be used frequently as a preceding diagnosis to be applied before the use of specific diagnostic methods for each type of cancer, which are much more expensive and still very rare.

Conclusion

Cerumen is a fingerprint of both polar and nonpolar substances excreted by biochemical reactions, and cancer cells produce different substance than healthy cells. These differences in chemical composition can be monitored to determine cancer early, since cerumen is continuously excreted. This new analytical test development obtained 100% efficiency in the discrimination of all samples used in this work, separating the cancer from the control group samples. The Cerumenogram is performed in a total time of around 3 hours, with an estimated analysis cost of US$ 50/per sample. This means that the analysis of VOMs in cerumen is a simple, fast, and cheap way to identify cancer, with the highest accuracy possible for a human that suffers from cancer. Furthermore, cerumen presents many advantages, such as painless collection and no liability of external contamination. This new method will allow a number of biomarkers identified for cancer diseases, 27 VOMs, to be monitored in an emergency or routine test, substantially reducing deaths from these diseases. The trend is that, from the encouraging data obtained here, soon, a so-called Cerumenogram will be a diagnostic test as common as a blood count is today, making it possible to save lives that could be eradicated by one of the deadliest diseases.

Methods

Test population: Patients and sample collection

Cerumen samples from 102 volunteers were collected at oncology unit of the Clinical Hospital, Federal University of Goiás (HC/UFG – Goiás, Brazil). Samples were collected from volunteers’ ears using a metallic curette and transferred in Eppendorf tubes, which were closed and stored in a freezer at −20 °C. All analyses were carried out a maximum of 7 days after the collect. The patients were divided into two groups: control group (Healthy subjects; cancer free, n = 50, age range 2–65 years old, 29 males and 21 females), and cancer group (n = 52, age range 33–83 years old, 25 males and 27 females).

Ethics committee approval

All volunteers who agreed to participate in this study signed an informed consent after the approval of local ethics committee at the Federal University of Goiás (#57880516.9.0000.5083). A questionnaire about their medical history was applied with the aimed of identifying and eliminating metabolites from medications, licit drugs, and treatment of past diseases that can show VOMs not coming from the cancer diseases or from the patient’s health conditions. Every step in this study was strictly conducted by following the Declaration of Helsinki. The main information extracted from the volunteers’ questionnaires are summarized in Table S2.

VOMs analysis

Cerumen samples were analyzed according to the recent method created in our research group29. In this way, 20 mg of each cerumen sample collected was weighed into 20 mL GC headspace vials and 0.2 µL of 3-methylcyclohexanone (Sigma-Aldrich, Saint Louis, MO, USA) was added as IS. In addition, gas-tight polytetrafluoroethylene (PTFE)-lined rubber septum caps were used to seal the vials. Then, the analyses were carried out by HS/GC-MS, applying all steps pre-established for GC-MS-based metabolomics, such as baseline correction, noise reduction, retention time alignment, and data-normalization79,80.

HS/GC-MS equipment

The cerumen sample analyses were conducted using a Shimadzu GCMS-QP2010 Ultra system and a Shimadzu AOC-5000 headspace analyzer (Shimadzu, Japan). The system uses a 2500 µL gas-tight syringe, a VT32–20 tray for 20 mL standard vials (PAL System, Zwingen, Switzerland) with a preheating module LHS0 Combi Pal with heating time and control of temperature (PAL System, Zwingen, Switzerland).

Headspace

Headspace sampler parameters were configured at: fill volume (2500 µL), fill speed (100 µL s−1), injection volume (2500 µL), injection speed (1 mL s−1), syringe temperature (150 °C), pre-warm time (10 min), equilibration time (3 min), syringe flushing time (5 min), re-flush time (5 ms), and post-flush time (5 ms). The preheating module parameters were set at: agitation speed (500 rpm), agitation on time (5 s), agitation off time (3 s), incubation temperature (160 °C), time of incubation (60 min).

Gas chromatography

VOMs were eluted in an analytical capillary column NST-100-ms (25 m × 0.25 mm i.d. × 0.3 µm film thickness) (NST, São Paulo, Brazil) with a polyethylene glycol high-polarity stationary phase. The injector was operated at 250 °C in the splitless mode applied with high purity helium (99.999% - 5.0, Helium, Air Liquide) as a carrier gas with a constant flow rate of 1.36 mL min−1 with a linear velocity for the carrier gas of 45.8 cm s−1. The oven temperature programming was set at: elution start in 30 °C (with isothermal heating for 5 min), a 2 °C min−1 gradient up until 45 °C (held 5 min), followed by another increase at 2 °C min−1 to 50 °C (held 5 min), another increase at 2 °C min−1 to until 120 °C, and another with 6 °C min−1 to 200 °C (held 5 min) ending at 5 °C min−1 to 250 °C (held 10 min), for a total of GC run time of 98.33 min.

Mass spectrometry

MS spectra of VOMs were acquired by electron ionization (EI) mode at 70 eV. The star cut-off time for MS recording was 0 min. Data acquisition was performed in full scan mode from 40 to 500 m/z with a scan time of 0.3 s and a scan speed of 1666 u s−1. The cerumen VOMs were confirmed by comparing their MS patterns with those of valid standards (ST) run in the same GC conditions, and by NIST11s Mass Spectral Library. Only compounds with more than 80% probability of a match to NIST11s library standards were considered. Finally, all the VOMs chromatographic peaks were confirmed by their respective retention time relative to the IS.

Statistical methods

The raw data generated in our analysis provides a total of 158 observations (chromatographic peaks) extracted from the test groups. A binary data model was constructed, where the 158 variables detected were transformed into binary output express as 1 for presence and 0 for absence, resulting in a data matrix of 102 rows representing the earwax samples by 158 columns for the VOMs.

Data treatment

A variable selection procedure using the GA-PLS results in 27 selected variables. The GA-PLS parameters were set as: population size of 100, window width at 1, maximum number of variables in each population of 100, convergence probability of 50%, mutation probability of 0.5%, maximum number of generations of 35, and contiguous cross-validation. HCA analyses using Ward agglomeration method were run applying Hamming distances as proximity measures of the binary data. GA-PLS was run according to PLS Toolbox 7.9 (Eigenvector Research Inc., Manson, WA, USA) algorithm using Matlab 2014b (MathWorks, Natick, MA, USA). The e1071 package was used to calculate Hamming distances under R version 3.5.1 (R Foundation for Statistical Computing, http://www.R-project.org)81.

Materials & correspondence

All data needed to interpret conclusions herein are presented in the paper and/or the Supplementary Information. Additional data related to this paper may be requested from the corresponding authors (J.M.G.B. and N.R.A.F.). Only the questionnaires filled out by the volunteers during the collection will not be available, due to the signature of their identity preservation agreement.

References

  1. 1.

    Ferlay, J., Wild, C. P. & Bray, F. The Burden of Cancer Worldwide: Current and Future Perspectives. Holland-Frei Cancer Med. 1–15, https://doi.org/10.1002/9781119000822.hfcm034 (2017).

  2. 2.

    Bray, A. et al. Global Cancer Statistics 2018: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. CA. Cancer J. Clin. 68, 1–31, https://doi.org/10.3322/caac.21492 (2018).

    Article  Google Scholar 

  3. 3.

    Weisburger, J. H. & Williams, G. M. The distinction between genotoxic and epigenetic carcinogens and implication for cancer risk. Toxicol. Sci. 57, 4–5, https://doi.org/10.1093/toxsci/57.1.4 (2000).

    CAS  Article  PubMed  Google Scholar 

  4. 4.

    Vineis, P. & Fecht, D. Environment, cancer and inequalities—The urgent need for prevention. Eur. J. Cancer 103, 317–326, https://doi.org/10.1016/j.ejca.2018.04.018 (2018).

    Article  PubMed  Google Scholar 

  5. 5.

    Frangioni, J. V. New technologies for human cancer imaging. J. Clin. Oncol. 26, 4012–4021, https://doi.org/10.1200/JCO.2007.14.3065 (2008).

    Article  PubMed  PubMed Central  Google Scholar 

  6. 6.

    Yokoi, A. et al. Integrated extracellular microRNA profiling for ovarian cancer screening. Nat. Commun. 9, 4319, https://doi.org/10.1038/s41467-018-06434-4 (2018).

    ADS  CAS  Article  PubMed  PubMed Central  Google Scholar 

  7. 7.

    Prensner, J. R., Rubin, M. A., Wei, J. T. & Chinnaiyan, A. M. Beyond PSA: The next generation of prostate cancer biomarkers. Sci. Transl. Med. 4, https://doi.org/10.1126/scitranslmed.3003180 (2012).

    Article  Google Scholar 

  8. 8.

    Hori, S. S. & Gambhir, S. S. Mathematical model identifies blood biomarker-based early cancer detection strategies and limitations. Sci. Transl. Med. 3, https://doi.org/10.1126/scitranslmed.3003110 (2011).

    Article  Google Scholar 

  9. 9.

    Cristescu, R. et al. Pan-tumor genomic biomarkers for PD-1 checkpoint blockade–based immunotherapy. Science. 362, eaar3593, https://doi.org/10.1126/science.aar3593 (2018).

    CAS  Article  PubMed  Google Scholar 

  10. 10.

    Din, S. et al. Mutational analysis identifies therapeutic biomarkers in inflammatory bowel disease-associated colorectal cancers. Clin. Cancer Res. clincanres. 3713, 2017, https://doi.org/10.1158/1078-0432.CCR-17-3713 (2018).

    Article  Google Scholar 

  11. 11.

    Andersen, J. N. et al. Pathway-based identification of biomarkers for targeted therapeutics: Personalized oncology with PI3K pathway inhibitors. Sci. Transl. Med. 2, https://doi.org/10.1126/scitranslmed.3001065 (2010).

    Article  Google Scholar 

  12. 12.

    Williams, R. M. et al. Noninvasive ovarian cancer biomarker detection via an optical nanosensor implant. Sci. Adv. 4, https://doi.org/10.1126/sciadv.aaq1090 (2018).

    ADS  Article  Google Scholar 

  13. 13.

    De Moraes, C. M. et al. Volatile biomarkers of symptomatic and asymptomatic malaria infection in humans. Proc. Natl. Acad. Sci. 115, 5780–5785, https://doi.org/10.1073/pnas.1801512115 (2018).

    CAS  Article  PubMed  Google Scholar 

  14. 14.

    Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A. & Haick, H. Hybrid Volatolomics and Disease Detection. Angew. Chemie - Int. Ed. 54, 11036–11048, https://doi.org/10.1002/anie.201500153 (2015).

    CAS  Article  Google Scholar 

  15. 15.

    Mal, M. Noninvasive metabolic profiling for painless diagnosis of human diseases and disorders. Futur. Sci OA 2, FSO106–FSO106, https://doi.org/10.4155/fsoa-2015-0014 (2016).

    CAS  Article  Google Scholar 

  16. 16.

    Sethi, S., Nanda, R. & Chakraborty, T. Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases. 26, 462–475, https://doi.org/10.1128/CMR.00020-13 (2013).

    CAS  Article  Google Scholar 

  17. 17.

    Hakim, M. et al. Volatile organic compounds of lung cancer and possible biochemical pathways. Chem. Rev. 112, 5949–5966, https://doi.org/10.1021/cr300174a (2012).

    CAS  Article  PubMed  Google Scholar 

  18. 18.

    Shokry, E. & Filho, N. R. A. Insights into cerumen and application in diagnostics: Past, present and future prospective. Biochem. Medica 27, https://doi.org/10.11613/BM.2017.030503 (2017).

  19. 19.

    Hardie, D. G. AMP-activated/SNF1 protein kinases: Conserved guardians of cellular energy. Nat. Rev. Mol. Cell Biol. 8, 774–785, https://doi.org/10.1038/nrm2249 (2007).

    CAS  Article  PubMed  Google Scholar 

  20. 20.

    Cao, D. et al. A Multiplex Model of Combining Gene-Based, Protein-Based, and Metabolite-Based With Positive and Negative Markers in Urine for the Early Diagnosis of Prostate Cancer. 710, 700–710, https://doi.org/10.1002/pros.21286 (2011).

    Article  Google Scholar 

  21. 21.

    Zhong, X. et al. Rapid recognition of volatile organic compounds with colorimetric sensor arrays for lung cancer screening. 3671–3681, https://doi.org/10.1007/s00216-018-0948-3 (2018).

    CAS  Article  Google Scholar 

  22. 22.

    Yang, J., Xu, G., Zheng, Y. & Kong, H. Diagnosis of liver cancer using HPLC-based metabonomics avoiding false-positive result from hepatitis and hepatocirrhosis diseases. 813, 59–65, https://doi.org/10.1016/j.jchromb.2004.09.032 (2004).

    CAS  Article  Google Scholar 

  23. 23.

    Sugimoto, M. & Wong, Æ. D. T. Capillary electrophoresis mass spectrometry-based saliva metabolomics identified oral, breast and pancreatic cancer-specific profiles. 78–95, https://doi.org/10.1007/s11306-009-0178-y (2010).

    Article  Google Scholar 

  24. 24.

    Goedert, J. J. et al. Fecal metabolomics: assay performance and association with colorectal cancer. 35, 2089–2096, https://doi.org/10.1093/carcin/bgu131 (2018).

    CAS  Article  Google Scholar 

  25. 25.

    Shokry, E. et al. Earwax metabolomics: An innovative pilot metabolic profiling study for assessing metabolic changes in ewes during periparturition period. PLoS One 12, 1–22, https://doi.org/10.1371/journal.pone.0183538 (2017).

    CAS  Article  Google Scholar 

  26. 26.

    Trumble, S. J. et al. Baleen whale cortisol levels reveal a physiological response to 20th century whaling. Nat. Commun. 9, https://doi.org/10.1038/s41467-018-07044-w (2018).

  27. 27.

    Prokop-Prigge, K. A., Thaler, E., Wysocki, C. J. & Preti, G. Identification of volatile organic compounds in human cerumen. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 953–954, 48–52, https://doi.org/10.1016/j.jchromb.2014.01.043 (2014).

    CAS  Article  Google Scholar 

  28. 28.

    Prokop-Prigge, K. A. et al. Ethnic/Racial and Genetic Influences on Cerumen Odorant Profiles. J. Chem. Ecol. 41, 67–74, https://doi.org/10.1007/s10886-014-0533-y (2014).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  29. 29.

    Shokry, E., de Oliveira, A. E., Avelino, M. A. G., de Deus, M. M. & Filho, N. R. A. Earwax: A neglected body secretion or a step ahead in clinical diagnosis? A pilot study. J. Proteomics 159, 92–101, https://doi.org/10.1016/j.jprot.2017.03.005 (2017).

    CAS  Article  PubMed  Google Scholar 

  30. 30.

    Shokry, E. et al. Earwax: A clue to discover fluoroacetate intoxication in cattle. Toxicon 137, 54–57, https://doi.org/10.1016/j.toxicon.2017.07.014 (2017).

    CAS  Article  PubMed  Google Scholar 

  31. 31.

    Shokry, E., Marques, J. G., Ragazzo, P. C., Pereira, N. Z. & Filho, N. R. A. Earwax as an alternative specimen for forensic analysis. Forensic Toxicol. 35, 348–358, https://doi.org/10.1007/s11419-017-0363-z (2017).

    Article  PubMed  PubMed Central  Google Scholar 

  32. 32.

    Leardi, R. & Lupiáñez González, A. Genetic algorithms applied to feature selection in PLS regression: How and when to use them. Chemom. Intell. Lab. Syst. 41, 195–207, https://doi.org/10.1016/S0169-7439(98)00051-3 (1998).

    CAS  Article  Google Scholar 

  33. 33.

    De Lacy Costello, B. et al. A review of the volatiles from the healthy human body. J. Breath Res. 8, https://doi.org/10.1088/1752-7155/8/1/014001 (2014).

    ADS  CAS  Article  Google Scholar 

  34. 34.

    Porto-Figueira, P., Pereira, J. A. M. & Câmara, J. S. Exploring the potential of needle trap microextraction combined with chromatographic and statistical data to discriminate different types of cancer based on urinary volatomic biosignature. Anal. Chim. Acta 1023, 53–63, https://doi.org/10.1016/j.aca.2018.04.027 (2018).

    CAS  Article  PubMed  Google Scholar 

  35. 35.

    Cavaco, C. et al. Screening of salivary volatiles for putative breast cancer discrimination: an exploratory study involving geographically distant populations. Anal. Bioanal. Chem. 410, 4459–4468, https://doi.org/10.1007/s00216-018-1103-x (2018).

    CAS  Article  PubMed  Google Scholar 

  36. 36.

    Hanahan & Weinberg. Cell - Hallmarks of Cancer: The Next Generation. Cell, Vol. 144, Issue 5, 646–674, 4 March 2011 144, 646–674, https://doi.org/10.1016/j.cell.2011.02.013 (2011).

    CAS  Article  Google Scholar 

  37. 37.

    Filipiak, W. et al. A Compendium of Volatile Organic Compounds (VOCs) Released By Human Cell Lines. Curr. Med. Chem. 23, 2112–2131, https://doi.org/10.2174/0929867323666160510122913 (2016).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  38. 38.

    Mochalski, P. et al. Ex vivo emission of volatile organic compounds from gastric cancer and non-cancerous tissue. J. Breath Res., https://doi.org/10.1088/1752-7163/aacbfb (2018).

    ADS  CAS  Article  Google Scholar 

  39. 39.

    Schwarz, K. et al. Breath acetone - Aspects of normal physiology related to age and gender as determined in a PTR-MS study. J. Breath Res. 3, https://doi.org/10.1088/1752-7155/3/2/027003 (2009).

    ADS  CAS  Article  Google Scholar 

  40. 40.

    Pereira, J. et al. Breath analysis as a potential and non-invasive frontier in disease diagnosis: An overview. Metabolites 5, 3–55, https://doi.org/10.3390/metabo5010003 (2015).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  41. 41.

    De Preter, V. et al. Faecal metabolite profiling identifies medium-chain fatty acids as discriminating compounds in IBD. Gut 64, 447–458, https://doi.org/10.1136/gutjnl-2013-306423 (2015).

    CAS  Article  PubMed  Google Scholar 

  42. 42.

    Francavilla, R. et al. Salivary microbiota and metabolome associated with celiac disease. Appl. Environ. Microbiol. 80, 3416–3425, https://doi.org/10.1128/AEM.00362-14 (2014).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  43. 43.

    Silva, C. L., Passos, M. & Câmara, J. S. Solid phase microextraction, mass spectrometry and metabolomic approaches for detection of potential urinary cancer biomarkers - A powerful strategy for breast cancer diagnosis. Talanta 89, 360–368, https://doi.org/10.1016/j.talanta.2011.12.041 (2012).

    CAS  Article  PubMed  Google Scholar 

  44. 44.

    Ahmed, I., Greenwood, R., Costello, B., Ratcliffe, N. & Probert, C. S. Investigation of faecal volatile organic metabolites as novel diagnostic biomarkers in inflammatory bowel disease. Aliment. Pharmacol. Ther. 43, 596–611, https://doi.org/10.1111/apt.13522 (2016).

    CAS  Article  PubMed  Google Scholar 

  45. 45.

    Willemsen, M., IJlst, L. & Steijlen, P. Clinical, biochemical and molecular genetic characteristics of 19 patients with the Sjögren–Larsson syndrome. Brain 124, 1426–1437, https://doi.org/10.1093/brain/124.7.1426 (2001).

    CAS  Article  PubMed  Google Scholar 

  46. 46.

    Dixon, E. et al. Solid-phase microextraction and the human fecal VOC metabolome. PLoS One 6, 1–9, https://doi.org/10.1371/journal.pone.0018471 (2011).

    CAS  Article  Google Scholar 

  47. 47.

    Jiménez-Pacheco, A. et al. Furan and p-xylene as candidate biomarkers for prostate cancer. Urol. Oncol. Semin. Orig. Investig. 36, 243.e21–243.e27, https://doi.org/10.1016/j.urolonc.2017.12.026 (2018).

    CAS  Article  Google Scholar 

  48. 48.

    Boots, A. W. et al. The versatile use of exhaled volatile organic compounds in human health and disease. J. Breath Res. 6, https://doi.org/10.1088/1752-7155/6/2/027108 (2012).

    ADS  Article  Google Scholar 

  49. 49.

    Passos, M. Investigation of urinary volatile organic metabolites as potential cancer biomarkers by solid-phase microextraction in combination with gas chromatography-mass spectrometry. Br. J. Cancer. 1894–1904, https://doi.org/10.1038/bjc.2011.437 (2011).

    CAS  Article  Google Scholar 

  50. 50.

    Garner, C. E. et al. Volatile organic compounds from feces and their potential for diagnosis of gastrointestinal disease. FASEB J. 21, 1675–1688, https://doi.org/10.1096/fj.06-6927com (2007).

    CAS  Article  PubMed  Google Scholar 

  51. 51.

    Koçer, M., Güldür, T., Akarçay, M., Miman, M. C. & Beker, G. Investigation of age, sex and menstrual stage variation in human cerumen lipid composition by high performance thin layer chromatography. J. Laryngol. Otol. 122, 881–886, https://doi.org/10.1017/S0022215107000783 (2008).

    Article  PubMed  Google Scholar 

  52. 52.

    Guest, J. F., Greener, M. J., Robinson, A. C. & Smith, A. F. Impacted cerumen: Composition, production, epidemiology and management. QJM - Mon. J. Assoc. Physicians 97, 477–488, https://doi.org/10.1093/qjmed/hch082 (2004).

    CAS  Article  Google Scholar 

  53. 53.

    Schwartz, S. R. et al. Clinical Practice Guideline (Update): Earwax (Cerumen Impaction). Otolaryngol. Head. Neck Surg. 156, S1–S29, https://doi.org/10.1177/0194599816671491 (2017).

    Article  PubMed  Google Scholar 

  54. 54.

    Hopf, N. B. et al. Skin permeation and metabolism of di(2-ethylhexyl) phthalate (DEHP). Toxicol. Lett. 224, 47–53, https://doi.org/10.1016/j.toxlet.2013.10.004 (2014).

    CAS  Article  PubMed  Google Scholar 

  55. 55.

    Zhang, S., Liu, L., Steffen, D., Ye, T. & Raftery, D. Metabolic profiling of gender: Headspace-SPME/GC-MS and1H NMR analysis of urine. Metabolomics 8, 323–334, https://doi.org/10.1007/s11306-011-0315-2 (2012).

    CAS  Article  Google Scholar 

  56. 56.

    Sinha, R. et al. Fecal Microbiota, Fecal Metabolome, and Colorectal Cancer Interrelations. PLoS One 11, e0152126, https://doi.org/10.1371/journal.pone.0152126 (2016).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  57. 57.

    Watson, W. P., Cottrell, L., Zhang, D. & Golding, B. T. Metabolism and molecular toxicology of isoprene. Chem. Biol. Interact. 135–136, 223–238, https://doi.org/10.1016/S0009-2797(01)00192-2 (2001).

    Article  PubMed  Google Scholar 

  58. 58.

    Bogaards, J. J. P., Freidig, A. P. & Van Bladeren, P. J. Prediction of isoprene diepoxide levels in vivo in mouse, rat and man using enzyme kinetic data in vitro and physiologically-based pharmacokinetic modelling. Chem. Biol. Interact. 138, 247–265, https://doi.org/10.1016/S0009-2797(01)00276-9 (2001).

    CAS  Article  PubMed  Google Scholar 

  59. 59.

    Chippendale, T. W. E., Španěl, P. & Smith, D. Time-resolved selected ion flow tube mass spectrometric quantification of the volatile compounds generated by E. coli JM109 cultured in two different media. Rapid Commun. Mass Spectrom. 25, 2163–2172, https://doi.org/10.1002/rcm.5099 (2011).

    ADS  CAS  Article  PubMed  Google Scholar 

  60. 60.

    Marchitti, S. A., Brocker, C., Stagos, D. & Vasiliou, V. Non-P450 aldehyde oxidizing enzymes: the aldehyde dehydrogenase superfamily. Expert Opin. Drug Metab. Toxicol. 4, 697–720, https://doi.org/10.1517/17425255.4.6.697 (2008).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  61. 61.

    Gill, P. A., van Zelm, M. C., Muir, J. G. & Gibson, P. R. Review article: short chain fatty acids as potential therapeutic agents in human gastrointestinal and inflammatory disorders. Aliment. Pharmacol. Ther. 48, 15–34, https://doi.org/10.1111/apt.14689 (2018).

    CAS  Article  PubMed  Google Scholar 

  62. 62.

    Wei, J. et al. Salivary metabolite signatures of oral cancer and leukoplakia. Int. J. Cancer 129, 2207–2217, https://doi.org/10.1002/ijc.25881 (2011).

    CAS  Article  PubMed  Google Scholar 

  63. 63.

    Frankel, A. E. et al. Metagenomic Shotgun Sequencing and Unbiased Metabolomic Profiling Identify Specific Human Gut Microbiota and Metabolites Associated with Immune Checkpoint Therapy Efficacy in Melanoma Patients. Neoplasia (United States) 19, 848–855, https://doi.org/10.1016/j.neo.2017.08.004 (2017).

    CAS  Article  Google Scholar 

  64. 64.

    Zhang, J. et al. Esophageal cancer metabolite biomarkers detected by LC-MS and NMR methods. PLoS One 7, https://doi.org/10.1371/journal.pone.0030181 (2012).

    ADS  CAS  Article  Google Scholar 

  65. 65.

    Weir, T. L., Manter, D. K., Sheflin, A. M., Barnett, B. A. & Heuberger, A. L. Stool Microbiome and Metabolome Differences between Colorectal Cancer Patients and Healthy Adults. PLoS One 8, e70803, https://doi.org/10.1371/journal.pone.0070803 (2013).

    ADS  CAS  Article  PubMed  PubMed Central  Google Scholar 

  66. 66.

    Cheng, Y. et al. Distinct urinary metabolic profile of human colorectal cancer. J. Proteome Res. 11, 1354–1363, https://doi.org/10.1021/pr201001a (2012).

    CAS  Article  PubMed  Google Scholar 

  67. 67.

    Lv, W. & Yang, T. Identification of possible biomarkers for breast cancer from free fatty acid profiles determined by GC-MS and multivariate statistical analysis. Clin. Biochem. 45, 127–133, https://doi.org/10.1016/j.clinbiochem.2011.10.011 (2012).

    CAS  Article  PubMed  Google Scholar 

  68. 68.

    Brown, D. G. et al. Metabolomics and metabolic pathway networks from human colorectal cancers, adjacent mucosa, and stool. Cancer Metab. 4, 1–12, https://doi.org/10.1186/s40170-016-0151-y (2016).

    CAS  Article  Google Scholar 

  69. 69.

    Domagala, A., Jarosz, T. & Lapkowski, M. Living on pyrrolic foundations - Advances in natural and artificial bioactive pyrrole derivatives. Eur. J. Med. Chem. 100, 176–187, https://doi.org/10.1016/j.ejmech.2015.06.009 (2015).

    CAS  Article  PubMed  Google Scholar 

  70. 70.

    Kulshreshtha, N. P. & Moldoveanu, S. C. Analysis of pyridines in mainstream cigarette smoke. J. Chromatogr. A 985, 303–312, https://doi.org/10.1016/S0021-9673(02)01472-3 (2003).

    CAS  Article  PubMed  Google Scholar 

  71. 71.

    Filipiak, W. et al. Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers. J. Breath Res. 8, https://doi.org/10.1088/1752-7155/8/2/027111 (2014).

    ADS  Article  Google Scholar 

  72. 72.

    Tangerman, A. Measurement and biological significance of the volatile sulfur compounds hydrogen sulfide, methanethiol and dimethyl sulfide in various biological matrices. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 877, 3366–3377, https://doi.org/10.1016/j.jchromb.2009.05.026 (2009).

    CAS  Article  Google Scholar 

  73. 73.

    Singh, S. & Lin, H. Hydrogen Sulfide in Physiology and Diseases of the Digestive Tract. Microorganisms 3, 866–889, https://doi.org/10.3390/microorganisms3040866 (2015).

    CAS  Article  PubMed  PubMed Central  Google Scholar 

  74. 74.

    Miakar, A. & Spiteller, G. Reinvestigation of lipid peroxidation of linolenic acid. Biochim. Biophys. Acta (BBA)/Lipids Lipid Metab. 1214, 209–220, https://doi.org/10.1016/0005-2760(94)90046-9 (1994).

    Article  Google Scholar 

  75. 75.

    Soini, H. A. et al. Analysis of Volatile Organic Compounds in Human Saliva by a Static Sorptive Extraction Method and Gas Chromatography-Mass Spectrometry. J. Chem. Ecol. 36, 1035–1042, https://doi.org/10.1007/s10886-010-9846-7 (2010).

    CAS  Article  PubMed  Google Scholar 

  76. 76.

    Kalluri, U., Naiker, M. & Myers, M. A. Cell culture metabolomics in the diagnosis of lung cancer - The influence of cell culture conditions. J. Breath Res. 8, https://doi.org/10.1088/1752-7155/8/2/027109 (2014).

    ADS  CAS  Article  Google Scholar 

  77. 77.

    Zhang, G. et al. Foxa1 defines cancer cell specificity. Sci. Adv. 2, https://doi.org/10.1126/sciadv.1501473 (2016).

    ADS  Article  Google Scholar 

  78. 78.

    Cohen, J. D. et al. Detection and localization of surgically resectable cancers with a multi-analyte blood test. Science. 359, 926–930, https://doi.org/10.1126/science.aar3247 (2018).

    ADS  CAS  Article  PubMed  PubMed Central  Google Scholar 

  79. 79.

    Katajamaa, M. & Orešič, M. Data processing for mass spectrometry-based metabolomics. J. Chromatogr. A 1158, 318–328, https://doi.org/10.1016/j.chroma.2007.04.021 (2007).

    CAS  Article  PubMed  Google Scholar 

  80. 80.

    Lubes, G. & Goodarzi, M. Analysis of Volatile Compounds by Advanced Analytical Techniques and Multivariate Chemometrics. Chem. Rev. 117, 6399–6422, https://doi.org/10.1021/acs.chemrev.6b00698 (2017).

    CAS  Article  PubMed  Google Scholar 

  81. 81.

    Hornik, K., Weingessel, A., Leisch, F. & Davidmeyerr-projectorg, M. D. M. Package ‘e1071’. (2018; https://cran.r-project.org/web/packages/e1071/e1071.pdf). [the easiest access to this source is via the URL] (2018).

Download references

Acknowledgements

This work was supporting by research funding provided by the “Coordenação de Aperfeiçoamento de Pessoal de Nível Superior” (CAPES) - Finance Code 001 - for the fellowship to J.M.G.B. and L.C.D. and the PNPD scholarship to E.S.; the research productivity grant to N.R.A.F. by the “Conselho Nacional de Desenvolvimento Científico e Tecnológico” (#312280/2016-5); and the management of financial resources by the “Fundação de Apoio à Pesquisa” (FUNAPE). We also thank to all the volunteers that accepted to participate and contribute to this work.

Author information

Affiliations

Authors

Contributions

J.M.G.B., N.P.Z., L.C.D., E.S. and N.R.A.F. developed the work conceptualization, visualization and the method validation. J.M.G.B., A.E.O. and N.R.A.F. performed the formal analysis, data curation, and writing-review and editing. J.M.G.B., E.S. and N.R.A.F. designed the methodology. J.M.G.B., N.P.Z. and L.C.D. conducted the experiments investigation. J.M.G.B., N.Z.P., L.C.D., C.G.O., M.F.G.S., M.A.G.A. an N.R.A.F. provided the data resources. J.M.G.B. and A.E.O. realized the software analysis. N.R.A.F. provided the funding acquisition and the project administration. J.M.G.B. and N.R.A.F. wrote the original draft.

Corresponding authors

Correspondence to João Marcos Gonçalves Barbosa or Nelson Roberto Antoniosi Filho.

Ethics declarations

Competing Interests

The authors declare no competing interests.

Additional information

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Barbosa, J.M.G., Pereira, N.Z., David, L.C. et al. Cerumenogram: a new frontier in cancer diagnosis in humans. Sci Rep 9, 11722 (2019). https://doi.org/10.1038/s41598-019-48121-4

Download citation

Further reading

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing