Abstract
Fluid overload in septic intensive care unit (ICU) patients is common and strongly associated with poor outcome. There is currently no treatment for capillary leak, which is mainly responsible for high positive fluid balance (FB) in sepsis. We hypothesized that increasing interstitial pressure with extensive corporeal compression would reduce FB. The objective of this study was to evaluate the feasibility, efficacy, and safety of a compression treatment during sepsis. This pilot, two-center, single-arm trial enrolled critically ill, non-surgical, septic patients receiving mechanical ventilation. The therapeutic intervention was the early application of compression bandages on more than 80% of the body surface. The primary outcome was negative net FB on day 7. The primary endpoint was reached in 29 of 45 patients (64%) with available data, for a planned objective of 26. By day 4, cumulative FB was 7280 ml [3300–9700]. SOFA- and aged-matched patients from a historical cohort had a significantly higher FB at 1, 2 and 7 days. Tolerance was good, although low-stage pressure ulcers were observed in 16 patients (26%). No effect on intra-abdominal pressure or respiratory plateau pressure was observed. In conclusion, corporeal compression demonstrated potential efficacy in limiting FB during septic shock, with acceptable feasibility and tolerance.
Similar content being viewed by others
Introduction
Fluid resuscitation is a cornerstone of supportive therapy at the acute phase of septic shock1 but it is associated with the risk of fluid overload. Due to the inflammation-induced increase in capillary permeability2, intravascular hypovolemia3,4,5 coexists with fluid overload in the interstitium, and is recognized as an independent risk factor of mortality6,7,8,9,10,11.
In the context of high vascular permeability, and as stated by the revised Starling equation, the main determinant for fluid transfer from the vessel lumen to the interstitium is the hydrostatic pressure difference between the intravascular and interstitial compartments (net filtration pressure)12. Until such time as these pressures become equal, plasma is filtered through the endothelium towards the interstitium, where fluid accumulates to form edema13. On the other hand, the large volume of fluid continuously leaking into the interstitium contributes to the persistent hypovolemia (with the need for repeated fluid replacement), hemodynamic instability, and associated organ failure that characterize septic shock. We hypothesized that the application of external pressure might increase interstitial pressure, immediately reducing the filtration pressure gradient and thereby the filtered volume. A similar approach for edema prevention has previously been proposed in acute respiratory distress syndrome (ARDS) patients with high alveolo-capillary permeability and edema reduction with positive airway pressure14. The present pilot study aimed to test the proof of concept of external corporeal compression to control fluid balance (FB), and evaluate the feasibility and tolerance of this technique.
Results
From February 2015 to December 2016, 62 patients were enrolled in the study. Thirteen patients (21%) died before day 7 and 4 patients (6.5%) were discharged from the ICU. Finally, 45 patients completed the protocol and had available fluid balance data at day 7 (Fig. 1). Table 1 shows the characteristics of the study population.
Bandage process
A median of three health care workers (from 2 to 6) were necessary to apply the bandages. The median time required to complete the bandage procedure was 20 minutes [17–25] using six 15cm-width and two 20cm-width bands. Bandages were handled for a median total time of 55 minutes per patient, mainly during the first day. An example of complete corporeal compression is shown in Fig. 2.
Protocol adherence
The time between admission and the first bandage was 9 hours on average (Table 1). The median duration of the bandage was 4 days [3–7]. Compression was discontinued for the following reasons: achievement of the pre-defined target (22 patients; 42%); suspected or confirmed compression-induced discomfort (9 patients; 17%); ICU discharge (6 patients; 12%); death before day 7 (7 patients; 13%); presence of cutaneous ulcers (3 patients; 6%); required surgical procedure (5 patients; 10%); repetitive diarrhea (1 patient; 2%); end-of-life decision (1 patient; 2%).
Primary outcome
The interim efficacy analysis was performed after the first stage of Simon’s plan (21 patients). The negative FB (<+500cc) rate at day 7 was observed in 13 of 21 patients (62%; 95% CI: 41,1%, 82,7%), allowing us to resume recruitment for the second stage as the threshold of 11 responses was reached. The final analysis was conducted as planned on the mITT population of 45 evaluable patients. A negative FB was observed in 29 of 45 patients with available data at day 7 (64%; 95% CI: 50.5%, 78.4%), exceeding the target of 26 responses. The day to day FB over the first 7 days is shown in Fig. 3.
Secondary outcomes
All secondary outcomes (including feasibility and safety) were analyzed in the intention-to-treat population (n = 62). The cumulative FB at day 4 was 7280 ml [3300–9700], which included the pre-compression volume resuscitation (2495cc [1350–3500]). In the first week after inclusion, 49 patients (79%) had at least one day with FB < + 500 ml, occurring before day 4 in 34 patients (69%). Total SOFA score decreased to 8 [4–10] after 72 h versus 12 [10–13] at the time of inclusion. Respiratory and renal sub-scores also decreased at 72 hours (2 [1.5–3] versus 3 [3–4] and 1 [0–2.5] versus 2 [0–3], respectively). The median time to norepinephrine weaning was 2 days [1.5–3]. The median length of ICU stay was 11 days [4–22] with a median duration of mechanical ventilation of 6 days [4–13]. Overall mortality was 29% in-ICU, 34% at 28 days and 50% at 90 days.
Historical control group
The fluid balance results of 50 patients from this study were compared to a group of 50 SOFA- and age-matched septic shock patients with acute kidney injury (AKI) from a historical cohort15. Demographic characteristics and fluid balance data for patients of both groups are summarized in Table 2. FB was significantly lower at 1, 2 and 7 days in the corporeal compression group (Fig. 4) This difference was not only the result of lower diuresis (which was expected, since all patients in the historical cohort had AKI) but was also due to significantly lower fluid requirements on days 1 and 2 (2330 vs. 2845, p < 0.001; and 2070 vs. 2835, p < 0.01, respectively), suggesting a role of compression in reducing capillary leak. Mortality was markedly lower in the corporeal compression group (18% vs 48% in the historical cohort at day 7, p = 0.001).
Compression tolerance
Median interface pressure was 17 mmHg [14–20] (measured 34 times in 14 patients). Pressure-induced ulcers were observed in 16 patients (26%), with 12 at stage I (persistent redness) and 4 at stage II (dermabrasion). No stage III or IV lesions were observed. Most of the lesions (10 patients) were located on the tibial crest and/or knees, especially in patients treated with prone positioning. Compression had to be discontinued in only 3 patients due to cutaneous lesions.
The abdominal pressure level was 10.5 mmHg [8–13] before compression and did not change significantly 12–24 hours after bandage application (11 mmHg [8–14], p = 0.57). It remained stable during the following days (Supplementary Fig. 1). The plateau pressure did not change significantly after bandage application (20 [16–25] vs. 21 [17–25] mbar after 12 hours, p = 0.46), nor did thoraco-pulmonary compliance (Supplementary Fig. 2).
Discussion
The present study is the first report of the use of corporeal compression to improve FB in septic shock patients. The primary endpoint, namely achieving a negative FB at day 7, was reached in 64% of the patients, suggesting that this treatment technique holds promise for future investigation in a phase III trial. At day 4, the cumulative FB was 7580 ml (including the FB recorded before compression), which is substantially lower than that reported by Boyd et al. at day 4 (11000 ml)7. This study, like ours, enrolled septic shock patients and recorded FB before patient inclusion. This discrepancy in the results could be due to a change in practice trending towards limiting fluid therapy. However, more recent studies with similar severity scores did not find significantly lower FBs16. Furthermore, when we compared FB in our cohort with a matched cohort of patients recruited more recently in our own centre, we confirmed the significantly lower FB in patients treated with compression, associated with a reduction in fluid requirements. The proportion of patients (69%) who had at least one day with FB < + 500 ml before day 4 also suggests a positive effect of compression. In an observational study, only 31% of septic shock patients had a negative FB before day 4, and they had a better survival rate9.
For this pilot study, we chose a single-arm design derived from cancer trials, the Simon’s plan. This type of design was developed specifically to optimize the sample size of early stage pharmaceuticals studies, for the preparation of phase III trials. At this stage, our study was not intended to provide a conclusive answer about the efficacy of the treatment. It confirmed the feasibility and safety of corporeal compression during sepsis, but its clinical benefits can only be assessed on intermediary endpoints compared to data from the literature and clinical experience.
The control of fluid overload is currently a major goal to improve sepsis management. The endothelial permeability is regulated by at least 5 known molecules during sepsis, with various signaling pathways17. Drugs targeting these regulatory mechanisms are currently under investigation18. However, it seems very difficult to target all these pathways involving various ligands and receptors and a mechanistic treatment such as this compression method might be the best approach for reduction of fluid overload and associated outcomes in sepsis.
This pilot study suffers from several limitations. First, although we used a historical cohort to serve as a reference, it does not constitute an adequate control group. The results of this study should be confirmed by an appropriate randomized controlled trial. Second, corporeal compression cannot reduce edema formation in vital organs such as the kidneys and lungs. However, when looking at the course of SOFA score in our population, our data shows that it tended to improve (especially the renal and respiratory sub-score) in the first few days when patients were wearing the compression. This suggests that organ edema does not increase during compression. Indeed, the purpose of compression is to prevent further leakage of intravascular fluid rather than filtrating excess interstitial fluid back into the circulation. On the other hand, we anticipated a risk of abdominal hypertension with compression, but abdominal pressure was not significantly increased and there seemed to be no consequence on the course of renal function.
Also, the outcome evaluation using FB at day 7 might bias the results, considering that the median duration of compression was 4 days in this study. Thus, 7 days might be too late for the outcome evaluation, with a risk of underestimating the efficacy of compression on FB. The choice of day 7 to evaluate the incidence of negative FB was empirical, in the absence of any published data on the duration of capillary leak in septic shock patients. Finally, the compression protocol was not optimal in terms of body surface coverage (especially in crucial zones where a large volume of edema accumulates, such as the buttocks and upper thighs), and in its effective duration (early discontinuation for various reasons). This could also lead to an underestimation of the potential efficacy of corporeal compression.
Conclusion
This study demonstrates the feasibility of corporeal compression in septic shock and suggests a benefit on FB control, and might thus warrant further investigation in a phase III trial.
Methods
Patients
This prospective, multicenter, single-arm pilot study was approved by an independent ethics committee (Comité de Protection des Personnes Est-II) on 21st January 2015. The study protocol was conducted in accordance with the relevant guidelines and regulations. It adheres to the Declaration of Helsinki and the guidelines for Good Clinical Practice. The study was registered with the European Union Drug Regulating Authorities Clinical Trials (EudraCT) and the French Health Products Safety Agency under the number 150017B-81. Each patient or their legal representative gave written informed consent after being provided with clear information.
Patients were recruited in 2 Intensive Care Units: one in Dijon (university teaching hospital), and one in Chalon-sur-Saone (non-academic hospital). The inclusion criteria were: age ≥ 18 years; ICU admission ≤24 hours; severe sepsis or septic shock (as defined by the Sepsis-2 definition19), ≤24 hours after the first hypotension; endotracheal intubation with mechanical ventilation. The exclusion criteria were: recent (≤2 weeks) abdominal/pelvic surgery, BMI > 40, local contraindication to bandages (i.e. acute limb ischemia, crush syndrome with rhabdomyolysis, limb compartment syndrome, infected leg ulcers), pregnant women, patients under protective measures, and moribund patients (expected survival ≤24 hours).
External compression method
Non-elastic (“short stretch”) bandages were applied to cover 80% of the body surface. The type of bandage used (SOMOS Standard®; BSN medical, Germany; 15 cm or 20 cm width) exerts a low interface pressure (i.e. pressure measured between the skin and the fabric) with a low risk of skin lesions but good anti-edema efficacy20,21. The specifically trained paramedic team applied the bandages first on the four limbs. Then, on the abdomen and torso, the bandage was applied from the buttocks (overlapping the upper thigh bandage) up to a horizontal line delimited by the nipples (under the breasts in women).
Study procedures
Compression was applied immediately after inclusion and bandages were changed once daily or more often if necessary. The compression was stopped when the FB was negative (difference between fluid intake and output ≤+500cc) for 2 consecutive days or at day 7, whichever came first. The fluid strategy was left at the discretion of the physician in charge of the patient, with no pre-defined protocol.
Skin tolerance of bandages was checked daily by visual skin inspection. The severity of ulcers was quoted using the National Pressure Ulcer Advisory Panel stages I to IV22. The presence of ulcers related to compression was considered a motive for discontinuation of bandage compression. Compression could also be stopped for any of the following reasons: intra-abdominal pressure (IAP; intravesical pressure checked twice daily23) increased to a level compatible with abdominal compartment syndrome (IAP > 15 mmHg + decrease in urine output)24; or airway pressure (plateau pressure) increased or dynamic compliance (in volume-controlled mode) decreased significantly with compression.
Fluid management was guided by the European Society of Intensive Care Medicine guidelines25. Repeated assessment of volume status (every 8 hours at least) was performed using a validated method such as inferior vena cava respiratory variations, pulse-pressure respiratory variations, and/or passive leg raising maneuver. Cristalloid fluid boluses were administered accordingly and repeated if necessary. The choice was given between a balanced solution (Ringer’s lactate) or saline.
Primary and secondary outcomes
The primary outcome was the rate of patients with a negative FB at day 7 (regardless of the duration of compression).
The secondary outcomes were: cumulative FB during the first 4 days; death rate at 7, 28 and 90 days; course of SOFA score in the first 3 days; time to norepinephrine weaning; in-ICU length of stay; and the number of days under mechanical ventilation. The additional workload (daily handling time) for the technique was estimated (nurse-estimated time for bandage application or re-application). The reproducibility of interface pressure (between skin and bandage) was also verified, measured above the ankle (point B)26, when possible, by the investigator, with a specific device (Kikuhime®, Harada Co, Osaka, Japan).
Design and statistical analysis
We used Simon’s two-stage design27 with a one-sided alpha error of 10% and a power of 90%. In a historical cohort of septic shock patients from our center15, 50% of patients had a negative FB at day 7; we used this reference to define the minimum response rate to achieve. We initially expected a response rate of 70% with compression. A sample size of 45 evaluable patients was needed under these assumptions27.
The primary outcome was planned for the modified intention-to-treat (mITT) population (i.e. all patients with FB data at day 7) and was reported with one-sided exact 95% confidence interval. The first interim analysis (first stage of Simon’s design) was conducted after inclusion of the first 21 evaluable patients. The trial could be terminated if 11 or fewer patients had a negative FB at day 7 (i.e. discontinuation for futility). If the threshold of 12 patients was met, the trial could continue with the enrollment of the next 24 patients to reach 45 evaluable patients. Overall, if a total of 26 responses or more were observed, the treatment would be considered a success27.
The secondary outcomes were planned for the intention-to-treat (ITT) population, including all enrolled patients. Categorical variables were expressed in percentage and continuous variables were expressed in median [interquartile range, IQR]. Survival was estimated by Kaplan-Meier method. Safety and tolerance are described for each adverse event. Statistical analyses were performed using SAS version 9.2 (SAS Institute Inc., Cary, NC, USA).
Historical control group
In addition, to complete the study and validate our hypothesis with a view to planning a future randomized clinical trial, we used a group of historical controls from a cohort of septic shock patients from our center15 who were not managed by corporeal compression, to compare the pragmatic efficacy of the corporeal compression strategy on fluid balance. Patients from this cohort were matched for SOFA score (±2) and age (±5 years). The analysis was conducted on the whole population (i.e. not only patients with FB data through day 7) as daily FB was the focus of interest. FB calculation methods and means (time of origin, pre-ICU FB) had to be similar between the 2 groups and was thus recalculated for the study patients, when possible. Overall, the analysis was conducted on 50 patients from the study group and 50 matched control patients (Supplementary Fig. 3). Differences between the two groups were compared at each day using the Mann Whitney test for continuous variables and Fisher’s exact test for qualitative variables.
Data Availability
The datasets generated and analyzed during the current study are available from the corresponding author on reasonable request.
References
Rhodes, A. et al. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. In 43, 304–377 (Springer Berlin Heidelberg, 2017).
Christ, F., Gamble, J., Gartside, I. B. & Kox, W. J. Increased microvascular water permeability in patients with septic shock, assessed with venous congestion plethysmography (VCP). Intensive Care Med 24, 18–27 (1998).
Goldenberg, N. M., Steinberg, B. E., Slutsky, A. S. & Lee, W. L. Broken Barriers: A New Take on Sepsis Pathogenesis. Sci Transl Med 3, 88ps25–88ps25 (2011).
Lee, W. L. & Slutsky, A. S. Sepsis and endothelial permeability. N Engl J Med 363, 689–691 (2010).
Rivers, E. et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. The New England journal of medicine 345, 1368–1377 (2001).
Payen, D. et al. A positive fluid balance is associated with a worse outcome in patients with acute renal failure. Crit Care 12, R74 (2008).
Boyd, J. H., Forbes, J., Nakada, T.-A., Walley, K. R. & Russell, J. A. Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality*. Critical Care Medicine 39, 259–265 (2011).
Sadaka, F., Juarez, M., Naydenov, S. & O’Brien, J. Fluid Resuscitation in Septic Shock: The Effect of Increasing Fluid Balance on Mortality. J Intensive Care Med 29, 213–217 (2013).
Alsous, F., Khamiees, M., DeGirolamo, A., Amoateng-Adjepong, Y. & Manthous, C. A. Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study. Chest 117, 1749–1754 (2000).
Cordemans, C. et al. Fluid management in critically ill patients: the role of extravascular lung water, abdominal hypertension, capillary leak, and fluid balance. Ann Intensive Care 2(Suppl 1), S1 (2012).
Grams, M. E. et al. Fluid balance, diuretic use, and mortality in acute kidney injury. Clin J Am Soc Nephrol 6, 966–973 (2011).
Levick, J. R. & Michel, C. C. Microvascular fluid exchange and the revised Starling principle. Cardiovasc. Res. 87, 198–210 (2010).
Wiig, H., Rubin, K. & Reed, R. K. New and active role of the interstitium in control of interstitial fluid pressure: potential therapeutic consequences. Acta Anaesthesiologica Scandinavica 47, 111–121 (2003).
Constantin, J.-M. et al. Response to recruitment maneuver influences net alveolar fluid clearance in acute respiratory distress syndrome. Anesthesiology 106, 944–951 (2007).
Barbar, S. D. et al. Timing of Renal-Replacement Therapy in Patients with Acute Kidney Injury and Sepsis. N Engl J Med 379, 1431–1442 (2018).
Rameau, A., de With, E. & Boerma, E. C. Passive leg raise testing effectively reduces fluid administration in septic shock after correction of non-compliance to test results. Ann Intensive Care 7, 2 (2017).
Russell, J. A., Rush, B. & Boyd, J. Pathophysiology of Septic Shock. Crit Care Clin 34, 43–61 (2018).
Lewis, R. J. et al. Rationale and Design of an Adaptive Phase 2b/3 Clinical Trial of Selepressin for Adults in Septic Shock. Selepressin Evaluation Programme for Sepsis-induced Shock-Adaptive Clinical Trial. Ann Am Thorac Soc 15, 250–257 (2018).
Levy, M. M. et al. 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference. In 31, 1250–1256 (2003).
Ladwig, A., Haase, H., Bichel, J., Schuren, J. & Jünger, M. Compression therapy of leg ulcers with PAOD. Phlebology 29, 7–12 (2014).
van Geest, A. J., Veraart, J. C. J. M., Nelemans, P. & Neumann, H. A. M. The Effect of Medical Elastic Compression Stockings with Different Slope Values on Edema. Dermatologic Surgery 26, 244–247 (2000).
Black, J. et al. National Pressure Ulcer Advisory Panel’s updated pressure ulcer staging system. Adv Skin Wound Care 20, 269–274 (2007).
Malbrain, M. L. N. G. et al. Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions. In 32, 1722–1732 (Springer-Verlag, 2006).
Malbrain, M. L. N. G., De Laet, I. & Cheatham, M. Consensus conference definitions and recommendations on intra-abdominal hypertension (iah) and the abdominal compartment syndrome (acs) - the long road to the final publications, how did we get there? Acta Clin Belg 62(Suppl 1), 44–59 (2007).
Cecconi, M. et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. In 40, 1795–1815 (2014).
Partsch, H. & Mosti, G. Comparison of three portable instruments to measure compression pressure. Int Angiol 29, 426–430 (2010).
Simon, R. Optimal two-stage designs for phase II clinical trials. Control Clin Trials 10, 1–10 (1989).
Acknowledgements
The authors thank Fiona Ecarnot (EA3920, University Hospital Besancon, France) for translation and editorial assistance, and the nursing teams of the Dijon University Hospital and William Morey Hospital, for their dedication to this protocol.
Author information
Authors and Affiliations
Consortia
Contributions
A.D., A.L., A.S.F., P.E.C., S.P. and J.P.Q. designed the trial. A.D., A.L., J.P.Q., D.P. and A.S.F. drafted the manuscript. A.S.F. and L.J. prepared the methodological plan and statistical analysis. A.D., A.L., J.M.D., C.A., P.A., P.E.C., S.P., J.P.Q. recruited patients and recorded data. A.D., A.L., A.S.F., J.M.D., C.A., P.A., J.B.R., S.P., P.E.C., D.P. and J.P.Q. read and approved the final manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
A comprehensive list of consortium members appears at the end of the paper
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Dargent, A., Large, A., Soudry-Faure, A. et al. Corporeal Compression at the Onset of Septic shock (COCOONs): a compression method to reduce fluid balance of septic shock patients. Sci Rep 9, 11566 (2019). https://doi.org/10.1038/s41598-019-47939-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-019-47939-2
This article is cited by
-
Fluid accumulation syndrome in sepsis and septic shock: pathophysiology, relevance and treatment—a comprehensive review
Annals of Intensive Care (2024)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.