Abstract
In recent years, silicon photonic platforms have undergone rapid maturation enabling not only optical communication but complex scientific experiments ranging from sensors applications to fundamental physics investigations. There is considerable interest in deploying photonics-based communication and science instruments in harsh environments such as outer space, where radiation damage is a significant concern. In this study, we have examined the impact of cobalt-60 γ-ray radiation up to 1 megagray (MGy) absorbed dose on silicon photonic devices. We do not find any systematic impact of radiation on passivated devices, indicating the durability of passivated silicon devices under harsh conditions.
Introduction
The last three decades have witnessed an exponential growth in photonics, driven in part by improvements in micro-electronics fabrication techniques and by increasing adoption of photonics components by the telecommunications industry. Tools originally developed for the telecommunications industry are now being exploited to develop novel sensors for a wide variety of applications and deployment scenarios1,2,3,4,5,6,7,8,9. Photonic sensors and communication systems are particularly valuable for operation in harsh environments, e.g. outer space and nuclear power plants, due to their small size, low power consumption, and tolerance to environmental variables such as mechanical vibrations10,11,12,13.
Such devices are nevertheless quite sensitive to external stimuli that produce changes in refractive index of the host material. In suitably designed photonic devices, small changes in temperature can produce measurable changes in resonance peak wavelength, thus making them useful for photonic thermometry and similar applications9. This sensitivity to refractive index is geometrically increased in resonant devices, like the ring resonator or photonic crystal cavity, where refractive index sensitivity grows with the device’s quality factor. Whether this sensitivity affects their usefulness in high radiation environments, however, is an open question10,13. Radiation induced damage is known to cause dislocations and other defects in crystalline structure that affect refractive index14. We recently demonstrated that Ge-doped fiber Bragg gratings (FBG) show complex dose-dependent changes in resonance peak center resulting in significant offset errors of up to ± 16.5 °C in thermometry applications15. These changes in Bragg resonance are independent of the polymer coating15 and likely derive from significant change in Ge coordination14.
In silicon-on-insulator (SOI) based electronic devices, trapped charges and local changes in bond structure are a known cause of device failure16. In principle, changes in the refractive index due to changes in free carrier population and damage to the Si lattice can significantly degrade the measurement sensitivity and accuracy of a photonic sensor. Bhandaru et al.17 have reported that unpassivated Si ring resonator devices exposed to relatively low levels of ionizing radiation (<9 kGy) show a blue shift in resonance wavelength which was not observed for passivated devices exposed to ≈1.5 kGy of ionizing radiation. The authors attributed the observed shift in unpassivated devices to accelerated growth of native oxide. Similar results have been reported for amorphous silicon and silicon nitride devices11,12. We note that a photonic sensor operating in a high radioactivity environment such as a nuclear power plant is expected to receive about 1 MGy18 of dose per year. Under such conditions it is possible that sensor performance may be negatively impacted by changes in refractive index, covalent bond breaking, radiation induced densification and/or changes in surface chemistry. Such changes would result in increased propagation losses resulting in lower quality factors and drift in resonance wavelength of resonant devices.
In this study, we systematically examine the impact of γ-radiation, up to a cumulative dose of 1 MGy (1 Gy = 100 Rad) from 60Co γ-ray radiation on silicon ring resonators and Bragg waveguides across multiple devices and chips. The dose absorbed by such chips was modelled using a radiation transport Monte Carlo simulation based on engineering drawings of the source and previous measurements of the radiation field. Further details of the Monte Carlo simulations used to calculate absorbed dose and the experimental setup are given in the Methods section. Our results indicate that silicon photonic devices can withstand high cumulative doses without any significant degradation in performance.
Results
Bragg waveguides
Bragg waveguides and ring resonators exposed to varying levels of γ-ray radiation do not show any significant changes in spectral characteristics. A typical Bragg waveguide transmission spectrum, shown in Fig. 1, does not show any systematic changes in either the peak center or the bandwidth of the Bragg waveguide rejection window. The variation in peak center observed between the different dose spectra is found to be 8 pm and is not correlated with dose (R2 = 0.28). Similarly, variation in linewidth (2.6 pm) is poorly correlated with dose (R2 = 0.54) and is within the measurement uncertainty of ±7 pm. The linewidth in a Bragg device is directly proportional to the refractive index contrast between the waveguide and etched step regions (where the evanescent field interacts with the surrounding oxide material, sampling an effectively lower refractive index than the unetched waveguide region)19. A lack of significant change in Bragg linewidth, therefore, suggests the oxide layer immediately next to the Si does not suffer any significant changes such as bond breaking or densification of the oxide layer due to radiation exposure. Similarly, a lack of significant change in peak isolation suggests the devices escaped with little to no damage to the Si surface or lattice.
Ring resonators
In ring resonators, where spectral consequences of small changes in device characteristics, such as refractive index, are expected to magnify due to recirculation of light in the ring structure, we do not observe any significant dependence on absorbed dose. We have examined the impact of radiation in several ring resonator devices with quality factors (Q-factors) ranging from 5,000 to 30,000 at room temperature. As shown in Figs 2 and 3, ring resonator devices do not show any significant dose-dependent change in the free spectral range (FSR), Q-factor, and peak position. The FSR was uncorrelated with dose (R2 =0.08), with a standard deviation for the 4 doses of 2.5 pm (0.031%). The Q-factor did decrease over time, but that decrease was the same for the control chip as for the irradiated chips and thus cannot be unambiguously ascribed to dose (Fig. 2 top). The observed decrease of ≈12% in Q-factor is correlated with peak input power and is reproduced when input power is doubled, indicating the observed effect is due to the device undergoing self-heating during the laser scan, not radiation damage. The small variation in absolute peak position observed for Chips 1–3 between irradiations (average standard deviation of [13 ± 13] pm) is statistically indistinguishable to changes observed in the control chip. This small variability was found to be random, with the most stringent test coming from the peak position at 20 °C (measured at 0 Gy dose), which was found to be uncorrelated to dose, with R2 = 0.01. We note that all four chips are from the same batch and contain the same devices. The control chip traveled with the other chips to and from the photonics lab to the radiation facility but was never exposed to radiation itself.
As quantified above, the FSR of the devices does not show any significant changes, clearly indicating that neither the group index nor the dispersion (parameters important in communication systems) is impacted by radiation exposure. Examination of the temperature-dependent response of ring resonator devices shows that the temperature sensitivity is also not impacted by radiation dose. For the data shown in Fig. 3, the average and standard deviation of the three responses was (76.9 ± 0.2) pm/°C. A linear regression of response as a function of dose returned a slope of (−4 ± 2) \({10}^{-4}\frac{{\rm{pm}}}{^\circ {\rm{C}}\cdot {\rm{Gy}}}\), which was not significant at the 95% level (t = −1.8, p = 0.32). The slight offset variability observed between doses (residuals shown in Fig. 3 insert) is within the limited precision of the thin film resistance thermometer (±0.1 °C) when employed using nominal coefficients.
Discussion
In this study, we have examined the impact of ionizing radiation on silicon photonics devices. Devices were irradiated within a self-contained, commercially produced 60Co irradiator, and delivered doses were estimated using well-established widely available Monte Carlo codes. Measurement of device characteristics such as peak center, peak width, FSR and temperature sensitivity do not reveal any significant dose-dependent changes, indicating that for all devices tested, the characteristic group index, dispersion and thermo-optic coefficient remain constant for aggregate doses up to 1 MGy (the maximum absorbed dose delivered in this study). These results are in stark contrast with those of FBG-based sensors, where radiation induced changes in Bragg resonance result in significant drift in device characteristics10,13,15. Our results bode well for efforts to leverage existing infrastructure in silicon photonics to develop communication and sensor platforms for operating in harsh environments, such as industrial sterilization of health care products or radiation processing systems where doses can be in the range 15 kGy to 300 kGy20,21, or nuclear power plants where dose rates of 10 kGy/h are possible18. Precision photonic sensors could find additional use in instrumentation used in radiotherapy clinics or space-based systems, where much lower aggregate doses (<100 Gy) are more commonplace but high reliability and accuracy are paramount22,23,24.
Methods
Photonic interrogation
The experimental measurement apparatus has been described in detail elsewhere9,25. Briefly, a C-band laser (New Focus TLB-6700 series1) is swept over the sensor resonance. Ten percent of laser power was immediately picked up from the laser output for wavelength monitoring (HighFinesse WS/7) while the rest is evanescently coupled to the photonic device under test using an optical fiber held within a few microns of the chip surface. The photonic chip itself was mounted on a Peltier assembly atop a 3-axis stage (Newport). Input from a platinum resistance thermometer (measurement accuracy ±0.1 °C) is fed to a proportional-integral-derivative controller that drives a thermoelectric cooler and maintains the temperature to within 0.02 °C of the set value. Photonic chips were fabricated at the CEA-LETI (Laboratoire d’Electronique des Technologies de l’Information, France) fabrication facility using Complementary Metal–Oxide–Semiconductor (CMOS) technology. Three of the representative chips from the batch were systematically exposed to varying levels of γ-ray radiation at the NIST high-dose dosimetry laboratory, while a fourth chip, used as a control, was never exposed to radiation, though it traveled with the other three chips between the photonics testing facility and the radiation facility.
Gamma-ray irradiation
Photonic sensors were irradiated with γ-rays in the NIST high-dose dosimetry laboratory. Three Gammacell (GC) 220 60Co irradiators (Nordion, Canada) were used with dose rates between 0.2 kGy/h and 3.9 kGy/h. Most of the irradiations were done using irradiator number GC207, which contained a nominal activity of 1.76*1014 Bq on a reference date of December 31, 2016 and delivered an absorbed dose rate to water, determined using alanine dosimetry, of R = 1.08 Gy/s on the reference date, with an expanded uncertainty26 of about 2%. This amounts to a dose rate per 60Co activity of D = 6.12*10−15 Gy/s/Bq.
Monte carlo calculations of absorbed dose
Monte Carlo simulations were undertaken to calculate the dose to the silicon devices based on measured dose to alanine calibration pellets. A simplified geometry for the GC 220 was created based on the irradiator specification sheet27 using the EGSnrc code DOSRZnrc28. The 1 cm diameter 60Co rods were simulated as a single cylindrical shell. Following Rodrigues et al.29, aluminum and steel shells of 2 mm thickness each were implemented between the sources and the exposure chamber. The 60Co emission spectrum was simplified to consist of two 1.25 MeV γ-rays.
Two irradiation geometries were simulated- the chamber calibration and chip irradiation, shown in Fig. 4. The calibration geometry, used to transfer calibration from the primary standard of absorbed dose to water, consists of 5-mm diameter alanine pellets stacked inside a polystyrene cylinder (pedestal) of wall thickness 3.7 mm30. For the chip irradiation, one chip at a time was placed inside a glass beaker of diameter and wall thickness of 30.5 mm and 1.3 mm, respectively. Although the chip device layer was only a few μm thick, the simulated dose to the chip was averaged over the top 100 μm of the chip, to achieve adequate Monte Carlo statistics.
For the calibration geometry, the EGSnrc simulated result was D = 6.23 10−15 Gy/s/Bq, which is 2% higher than the nominal calibrated value. This agreement is adequate, considering the approximate source geometry of the EGSnrc model and the Monte Carlo counting statistics of about 2%. Despite the adequate agreement in absolute dose per activity, the EGSnrc model was not used for an absolute calculation of dose, but only used to scale the dose from the calibration geometry to the chip geometry. For the chip geometry, the EGSnrc result was D = 5.42 10−15 Gy/s/Bq. Thus, the ratio of the calculated dose for the chip geometry to the calibration geometry was 0.870, with a total Monte Carlo uncertainty of about 3%.
Scaling the calibrated value for R by the ratio of the EGSnrc-calculated D values for the chip geometry to the calibration geometry, results in a dose rate to the chip of 0.94 Gy/s with an expanded uncertainty of 7% (k = 2).
An approximate gamma-ray field map was calculated by numerically solving an integral representing the γ-ray flux, F, inside a chamber consisting of a thin, radiating, cylindrical shell,
where L = 210 mm is the shell length, r = 105 mm is the shell radius, and (x,h) is the test position within the chamber. No interactions were considered. The field map, relative to the value in the center of the chamber, is shown in Fig. 5. Along the vertical axis of the chamber (x = 0), the field changes by −1% at z = ± 18 mm. Along the midplane of the chamber (h = 0), the field changes by +1% at x = ±1 mm. Therefore, the \(\approx 5\) mm positioning accuracy of the chip would not significantly affect the absorbed dose beyond the Monte Carlo and calibration accuracy.
To explore the issue of transient charged particle equilibrium (TCPE), a Geant431 Monte Carlo model was constructed for a version of the chip geometry. A 1.25 MeV γ-ray source was incident from the side of the chip, aligned with the center of the top layer, which was 200 μm thick – much thicker than the actual device layer, but still not thick enough to achieve TCPE. Only about 1 out of 50 γ-rays interact with the chip. Of those that do, about 80% produce Compton-scattered electrons that escape into the air from the top layer. Since there is not an equal energy flux of electrons produced in the air that pass into the top Si layer, TCPE is not achieved. Therefore, the absorbed dose to the chip cannot simply be calculated based only on the relative linear-energy transfer and density of silicon relative to water. Rather, full Monte Carlo simulations are required, as were done here.
Disclaimer
Certain equipment or materials are identified in this paper in order to specify the experimental procedure adequately. Such identification is not intended to imply endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the materials or equipment identified are necessarily the best available.
Data availability
The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Guha, B., Preston, K. & Lipson, M. Athermal silicon microring electro-optic modulator. Opt. Lett. 37, 2253–2255 (2012).
Kim, H.-T. & Yu, M. Cascaded ring resonator-based temperature sensor with simultaneously enhanced sensitivity and range. Optics Express 24, 9501–9510, https://doi.org/10.1364/OE.24.009501 (2016).
Qiu, F. et al. Athermal Hybrid Silicon/Polymer Ring Resonator Electro-optic Modulator. ACS Photonics 3, 780–783, https://doi.org/10.1021/acsphotonics.5b00695 (2016).
Li, M., Wu, X., Liu, L., Fan, X. & Xu, L. Self-Referencing Optofluidic Ring Resonator Sensor for Highly Sensitive Biomolecular Detection. Analytical Chemistry 85, 9328–9332, https://doi.org/10.1021/ac402174x (2013).
Oates, T. C. & Burgess, L. W. Sensitive Refractive Index Detection Using a Broad-Band Optical Ring Resonator. Analytical Chemistry 84, 7713–7720, https://doi.org/10.1021/ac3018907 (2012).
Bonnot, K. et al. Biophotonic Ring Resonator for Ultrasensitive Detection of DMMP As a Simulant for Organophosphorus Agents. Analytical Chemistry 86, 5125–5130, https://doi.org/10.1021/ac500903s (2014).
Ren, M. et al. Nano-optomechanical Actuator and Pull-Back Instability. ACS Nano 7, 1676–1681, https://doi.org/10.1021/nn3056687 (2013).
Shopova, S. I. et al. On-Column Micro Gas Chromatography Detection with Capillary-Based Optical Ring Resonators. Analytical Chemistry 80, 2232–2238, https://doi.org/10.1021/ac702389x (2008).
Xu, H. et al. Ultra-Sensitive Chip-Based Photonic Temperature Sensor Using Ring Resonator Structures. Optics Express 22, 3098–3104 (2014).
Brasch, V., Chen, Q.-F., Schiller, S. & Kippenberg, T. J. Radiation hardness of high-Q silicon nitride microresonators for space compatible integrated optics. Optics Express 22, 30786–30794, https://doi.org/10.1364/OE.22.030786 (2014).
Du, Q. et al. Gamma radiation effects in amorphous silicon and silicon nitride photonic devices. Optics Letters 42, 587–590, https://doi.org/10.1364/OL.42.000587 (2017).
Grillanda, S. et al. Gamma radiation effects on silicon photonic waveguides. Optics Letters 41, 3053–3056, https://doi.org/10.1364/OL.41.003053 (2016).
Morichetti, F. et al. Alpha Radiation Effects on Silicon Oxynitride Waveguides. ACS Photonics 3, 1569–1574, https://doi.org/10.1021/acsphotonics.6b00431 (2016).
Alessi, A. et al. Irradiation temperature influence on the in-situ measured radiation induced attenuation of Ge-doped fibers. IEEE Transactions on Nuclear Science PP, 1-1, https://doi.org/10.1109/TNS.2016.2627598 (2016).
Cumberland, L. T. et al. Radiation Hardness of Fiber Bragg Grating Thermometers. arXiv:1710.07176 [physics.ins-det] (2017).
Schrimpf, R. D. et al. In 2010 IEEE International SOI Conference (SOI) 1–4 (San Diego, CA, 2010).
Bhandaru, S., Hu, S., Fleetwood, D. M. & Weiss, S. M. Total Ionizing Dose Effects on Silicon Ring Resonators. IEEE Transactions on Nuclear Science 62, 323–328, https://doi.org/10.1109/TNS.2014.2387772 (2015).
Fernandez, A. F. et al. Long-term radiation effects on fibre Bragg grating temperature sensors in a low flux nuclear reactor. Measurement Science and Technology 15, 1506–1511, https://doi.org/10.1088/0957-0233/15/8/013 (2004).
Klimov, N. N., Mittal, S., Berger, M. & Ahmed, Z. On-chip silicon waveguide Bragg grating photonic temperature sensor. Optics Letters 40, 3934–3936, https://doi.org/10.1364/OL.40.003934 (2015).
ANSI/AAMI/ISO. Sterilization of health care products - Radiation - Part 2: Establishing the sterlization dose. ANSI/AAMI/ISO 11137-2 (2013).
Rouif, S. Radiation cross-linked polymers: Recent developments and new applications. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 236, 68–72, https://doi.org/10.1016/j.nimb.2005.03.252 (2005).
Grimm, J. L. et al. tolerance limits and dose volume histogram evaluation for stereotactic body radiotherapy. Journal of Applied Clinical Medical Physics 12 (2011).
Guo, J. et al. Variations of dose rate observed by MSL/RAD in transit to Mars. Astronomy & Astrophysics 577, A58, https://doi.org/10.1051/0004-6361/201525680 (2015).
Domen, S. R. A Sealed Water Calorimeter for Measuring Absorbed Dose. Journal of Research of the National Institute of Standards and Technology 99, 121–141 (1994).
Ahmed, Z., Filla, J., Guthrie, W. & Quintavall, J. Fiber Bragg Gratings Based Thermometry. NCSLI Measure 10, 24–27 (2015).
Desrosiers, M. F., Puhl, J. M. & Cooper, S. L. An Absorbed-Dose/Dose-Rate Dependence for the Alanine-EPR Dosimetry System and Its Implications in High-Dose Ionizing Radiation Metrology. J. Res. Natl,. Inst. Stand. Technol. 113, 79–95 (2008).
GAMMACELL 220 Instruction manual, 6th edition, Atomic Energy of Canada Limited. (Atomic Energy of Canada, Ottawa, 1968).
Kawrakow, I., Mainegra-Hing, E., Rogers, D.W.O., Tessier, F. & Walters, B.R.B. (ed NRCC Report) (Ottawa, 2017).
Rodrigues, R. R. et al. Retrieval of GammaCell 220 irradiator isodose curves with MCNP simulations and experimental measurements. Brazilian Journal of Physics 40, 120–124 (2012).
Humphreys, J. C. et al. Vol. NIST SP250-44, (NIST, Gaithersbrug, MD, 1998).
Agostinelli, S. et al. Geant4—a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 506, 250–303, https://doi.org/10.1016/s0168-9002(03)01368-8 (2003).
Acknowledgements
The authors acknowledge the NIST/CNST NanoFab facility for providing opportunity to fabricate silicon photonic temperature sensors.
Author information
Authors and Affiliations
Contributions
R.E.T. planned the irradiation scheme. L.T.C. and I.M.P. irradiated the chips. Z.A. and N.N.K. made the photonic measurements. Z.A. and R.F. analyzed the data. R.F. performed the Monte Carlo simulations. Z.A. and R.F. drafted the manuscript, R.E.T. and I.M.P. made significant edits, and all authors provided final review.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ahmed, Z., Cumberland, L.T., Klimov, N.N. et al. Assessing Radiation Hardness of Silicon Photonic Sensors. Sci Rep 8, 13007 (2018). https://doi.org/10.1038/s41598-018-31286-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-31286-9
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.