Abstract
To understand neural circuit mechanisms underlying behavior, it is crucial to observe the dynamics of neuronal structure and function in different regions of the brain. Since current noninvasive imaging technologies allow cellular-resolution imaging of neurons only within ~1 mm below the cortical surface, the majority of mouse brain tissue remains inaccessible. While miniature optical imaging probes allow access to deep brain regions, cellular-resolution imaging is typically restricted to a small tissue volume. To increase the tissue access volume, we developed a clear optically matched panoramic access channel technique (COMPACT). With probe dimensions comparable to those of common gradient-index lenses, COMPACT enables a two to three orders of magnitude greater tissue access volume. We demonstrated the capabilities of COMPACT by multiregional calcium imaging in mice during sleep. We believe that large-volume in vivo imaging with COMPACT will be valuable to a variety of deep tissue imaging applications.
This is a preview of subscription content, access via your institution
Access options
Access Nature and 54 other Nature Portfolio journals
Get Nature+, our best-value online-access subscription
$29.99 / 30 days
cancel any time
Subscribe to this journal
Receive 12 print issues and online access
$259.00 per year
only $21.58 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Data availability
The imaging datasets generated during and/or analyzed during the current study are available at https://doi.org/10.5281/zenodo.5110292 and https://doi.org/10.5281/zenodo.511030529. Source data for Figs. 3 and 4 and Extended Data Fig. 7 are provided with this paper.
Code availability
The code employed in the measurement and data analysis is available at https://doi.org/10.5281/zenodo.5047100.
References
Chen, T.-W. et al. Ultrasensitive fluorescent proteins for imaging neuronal activity. Nature 499, 295–300 (2013).
Denk, W. & Svoboda, K. Photon upmanship: why multiphoton imaging is more than a gimmick. Neuron 18, 351–357 (1997).
Betley, J. N. et al. Neurons for hunger and thirst transmit a negative-valence teaching signal. Nature 521, 180 (2015).
Cox, J., Pinto, L. & Dan, Y. Calcium imaging of sleep–wake related neuronal activity in the dorsal pons. Nat. Commun. 7, 10763 (2016).
da Silva, J. A., Tecuapetla, F., Paixão, V. & Costa, R. M. Dopamine neuron activity before action initiation gates and invigorates future movements. Nature 554, 244 (2018).
Attardo, A., Fitzgerald, J. E. & Schnitzer, M. J. Impermanence of dendritic spines in live adult CA1 hippocampus. Nature 523, 592 (2015).
Hunnicutt, B. J. et al. A comprehensive excitatory input map of the striatum reveals novel functional organization. eLife 5, e19103 (2016).
Howe, M. W. & Dombeck, D. A. Rapid signalling in distinct dopaminergic axons during locomotion and reward. Nature 535, 505 (2016).
Mittmann, W. et al. Two-photon calcium imaging of evoked activity from L5 somatosensory neurons in vivo. Nat. Neurosci. 14, 1089–U1195 (2011).
Ouzounov, D. G. et al. In vivo three-photon imaging of activity of GCaMP6-labeled neurons deep in intact mouse brain. Nat. Methods 14, 388–390 (2017).
Kondo, M., Kobayashi, K., Ohkura, M., Nakai, J. & Matsuzaki, M. Two-photon calcium imaging of the medial prefrontal cortex and hippocampus without cortical invasion. eLife 6, e26839 (2017).
Yacoub, E., Harel, N. & Uğurbil, K. High-field fMRI unveils orientation columns in humans. Proc. Natl Acad. Sci. USA 105, 10607–10612 (2008).
Levene, M. J., Dombeck, D. A., Kasischke, K. A., Molloy, R. P. & Webb, W. W. In vivo multiphoton microscopy of deep brain tissue. J. Neurophysiol. 91, 1908–1912 (2004).
Göbel, W., Kerr, J. N., Nimmerjahn, A. & Helmchen, F. Miniaturized two-photon microscope based on a flexible coherent fiber bundle and a gradient-index lens objective. Opt. Lett. 29, 2521–2523 (2004).
Jung, J. C., Mehta, A. D., Aksay, E., Stepnoski, R. & Schnitzer, M. J. In vivo mammalian brain imaging using one- and two-photon fluorescence microendoscopy. J. Neurophysiol. 92, 3121–3133 (2004).
Fu, L., Gan, X. & Gu, M. Characterization of gradient-index lens-fiber spacing toward applications in two-photon fluorescence endoscopy. Appl. Opt. 44, 7270–7274 (2005).
Flusberg, B. A. et al. High-speed, miniaturized fluorescence microscopy in freely moving mice. Nat. Methods 5, 935 (2008).
Chia, T. H. & Levene, M. J. Microprisms for in vivo multilayer cortical imaging. J. Neurophysiol. 102, 1310–1314 (2009).
Bocarsly, M. E. et al. Minimally invasive microendoscopy system for in vivo functional imaging of deep nuclei in the mouse brain. Biomed. Opt. Express 6, 4546–4556 (2015).
Barretto, R. P. et al. Time-lapse imaging of disease progression in deep brain areas using fluorescence microendoscopy. Nat. Med. 17, 223 (2011).
Yang, W. & Yuste, R. In vivo imaging of neural activity. Nat. Methods 14, 349 (2017).
Tearney, G. J. et al. In vivo endoscopic optical biopsy with optical coherence tomography. Science 276, 2037–2039 (1997).
Kim, P. et al. In vivo wide-area cellular imaging by side-view endomicroscopy. Nat. Methods 7, 303 (2010).
Gent, T. C., Bandarabadi, M., Herrera, C. G. & Adamantidis, A. R. Thalamic dual control of sleep and wakefulness. Nat. Neurosci. 21, 974–984 (2018).
Yüzgeç, Ö., Prsa, M., Zimmermann, R. & Huber, D. Pupil size coupling to cortical states protects the stability of deep sleep via parasympathetic modulation. Curr. Biol. 28, 392–400. e393 (2018).
Resendez, S. L. et al. Visualization of cortical, subcortical and deep brain neural circuit dynamics during naturalistic mammalian behavior with head-mounted microscopes and chronically implanted lenses. Nat. Protoc. 11, 566 (2016).
Leith, E. N. & Upatnieks, J. Reconstructed wavefronts and communication theory. JOSA 52, 1123–1130 (1962).
Tang, J., Germain, R. N. & Cui, M. Superpenetration optical microscopy by iterative multiphoton adaptive compensation technique. Proc. Natl Acad. Sci. USA 109, 8434–8439 (2012).
Wei, B.W. et al. Clear optically matched panoramic access channel technique (COMPACT) for large-volume deep brain imaging. Zenodo https://doi.org/10.5281/zenodo.5110292 and https://doi.org/10.5281/zenodo.5110305 (2021).
Acknowledgements
This work was funded by the NIH (grant nos. U01NS094341, U01NS107689, U01NS118302 to M.C.) and Purdue University. The funders had no role in study design, data collection and analysis, decision to publish or preparation of the manuscript. M.C. thanks S. Sternson (HHMI Janelia research campus) and J. Isaacson (UCSD) for valuable comments and discussion, and thanks the Howard Hughes Medical Institute for scientific instruments.
Author information
Authors and Affiliations
Contributions
M.C. invented COMPACT and designed and implemented the imaging system. M.C. and W.-B.G. supervised the research. W.-B.G. designed the biology experiment. B.W., C.W. and Z.C. collaborated on the experiment, data analysis and figure preparation. B.L. assisted the EEG/EMG and sleep studies. All authors contributed to the writing of the manuscript.
Corresponding author
Ethics declarations
Competing interests
In March 2020, Purdue University filed a utility patent for the COMPACT-based deep brain neurophotonic interface (inventor Meng Cui; U.S. Application No 16/833,550), which covered the concept, design and implementation of COMPACT.
Additional information
Peer review information Nina Vogt was the primary editor on this article and managed its editorial process and peer review in collaboration with the rest of the editorial team.
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data
Extended Data Fig. 1 Procedure for imaging probe alignment.
(a) Optical setup for probe alignment. (b) Images from camera 1 and 2. (c) Capillary alignment. (d) Top view of the capillary.
Extended Data Fig. 2 High-resolution compound probe for two-photon COMPACT imaging.
(a) Compound lens configuration. (b) Two-photon imaging of 0.5 μm fluorescence beads. (c, d) The imaging point spread function for imaging 100 and 400 μm outside the capillary, respectively. (e) Two-photon imaging of Thy1-eGFP mouse brain with an imaging depth of 1.8 mm. The maximum working distance reached 450 μm. (f) Neuronal structures at the indicated working distances.
Extended Data Fig. 3 Comparison of COMPACT imaging and dissected tissue imaging in Thy1-eGFP mouse brain.
(a, b) Image comparison for the bottom of the imaging volume (COMPACT probe at 0 degree). (c, d) Comparison for the region at which the COMPACT probe was at 24 degree. (e, f) Comparison for the region at which the COMPACT probe was at 52 degree.
Extended Data Fig. 4 Surgical procedure for capillary implantation.
(a) Design of the head-bar for head fixed animal imaging. (b) Illustration of the surgical procedures during capillary implantation.
Extended Data Fig. 5 Docking method for the imaging probe.
(a, b) Illustration of the docking approach for holding the imaging probe in place. (c) A quick-release probe holder for fine adjustment of probe orientation and depth. We employed this probe docking method for the calcium imaging of awake mice, which is shown in Supplementary Video 5.
Extended Data Fig. 6 Repeated probe insertion and imaging.
Cell locations before and after reloading the animal to the imaging system. The probe insertion repeatability can be reproduced in all experiments.
Extended Data Fig. 7 COMPACT-based calcium imaging with simultaneous electromyography (EMG) and electroencephalography (EEG) recording.
(a–c) Imaging locations for ROI 1 and 2. (d, e) Representative images showing calcium activity of neurons during awake and asleep states in ROI 1 and 2, respectively. The imaging experiments were repeated independently on 5 mice with similar results. (f, g) The EMG, EEG, ΔF/F0 of each cell and their average in ROI 1 and 2, respectively. The awake and asleep states are labeled on top, which was based on the EMG signal levels.
Supplementary information
Supplementary Information
Supplementary Figs. 1–5 and Table 1.
Supplementary Video 1
Design of the two-photon COMPACT imaging system. The optical configuration of the two-photon imaging system and the operation of whole-depth panoramic two-photon imaging.
Supplementary Video 2
Two-photon structural imaging of Thy1-eGFP mouse brain. The acquisition of the image volume shown in Supplementary Fig. 1b.
Supplementary Video 3
Comparison of COMPACT imaging and dissected tissue imaging in Thy1-eGFP mouse brain. The acquisition of the images shown in Extended Data Fig. 2.
Supplementary Video 4
Two-photon calcium imaging of awake mouse brain. The acquisition of the image volume shown in Fig. 3.
Supplementary Video 5
Two-photon calcium imaging of awake mouse brain using the probe docking method.
Supplementary Video 6
Longitudinal multiregional calcium imaging of neuronal activity associated with pupil size.
Source data
Source Data Fig. 3
Calcium activity source data.
Source Data Fig. 4
Calcium activity source data, pupil size source data, statistical source data.
Source Data Extended Data Fig. 7
EMG/EEG, calcium activity source data.
Rights and permissions
About this article
Cite this article
Wei, B., Wang, C., Cheng, Z. et al. Clear optically matched panoramic access channel technique (COMPACT) for large-volume deep brain imaging. Nat Methods 18, 959–964 (2021). https://doi.org/10.1038/s41592-021-01230-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41592-021-01230-3
This article is cited by
-
Geometric transformation adaptive optics (GTAO) for volumetric deep brain imaging through gradient-index lenses
Nature Communications (2024)
-
Large-volume and deep brain imaging in rabbits and monkeys using COMPACT two-photon microscopy
Scientific Reports (2022)