Introduction

Corrosion is the result of spontaneous chemical or electrochemical reactions between metals and the surrounding environment and has costly and detrimental effects on a variety of industries1,2. To achieve corrosion protection, corrosion-resistant alloys, organic coatings, corrosion inhibitors, and anodic/cathodic protection are widely used, but the limitations of these materials, such as high cost, heavy contamination, and operational difficulties, have not been complete overcome3,4,5,6. As a result of in-depth research on metal products that were preserved over a dozen centuries ago via archeological processes and metallic materials that were slightly degraded in renovation projects, it was found that microorganisms may play a key role in inhibiting corrosion7,8. Based on the above studies, microbiologically influenced corrosion inhibition (MICI), as an environmentally friendly anticorrosion method, is expected to be adopted as a green anticorrosion strategy in the future9,10,11.

MICI directly or indirectly mitigates corrosion through microorganisms and their metabolic activities, such as microbial respiration to consume corrosive substances, formation of an extracellular polymeric substance (EPS) protective layer, formation of a microbiologically induced mineralized layer, competitive microbial corrosion inhibition, and secretion of corrosion inhibitors12. Due to the complexity of the environment and the diversity of microorganisms, multiple MICI mechanisms may coexist and synergistically inhibit corrosion. For example, Faisal et al.13 discovered that Shewanella oneidensis sp., a facultative anaerobic iron-reducing bacterium (IRB), could inhibit corrosion of X52 carbon steel through aerobic respiration and iron respiration. After repeated redox deposition of iron and mixing with EPSs, a dense protective layer was formed on the metal surface, resulting in a maximum corrosion rate of only ~0.1 mm y−1 in an S. oneidensis-inoculated medium and ~0.5 mm y−1 in a sterile medium. Nardy et al.14 discovered the formation of mineral deposition layers on the surface of sheet pilings used for reinforcement of waterways and dikes, which did not suffer serious corrosion even after over 50 years of use. According to microbial community analysis, the formation of mineral deposition layers was closely related to the metabolic processes of methanogens15.

As an MICI mechanism, microbiologically induced carbonate precipitation (MICP) has been applied for corrosion protection and repair of concretes16,17,18,19,20,21. MICP refers to the use of microbial cell walls or EPSs as crystal nucleation sites to form a microenvironment with high concentrations of carbonate and calcium ions, thereby promoting the deposition of carbonates22,23,24,25. Due to differences in the metabolic characteristics of microorganisms, the morphology of calcium carbonate can vary, with forms such as calcite, aragonite, and vaterite, among which calcite is the most stable crystal structure26,27. Xu et al.28 investigated the potential of Sporosarcina pasteurii DSM 33 immobilized in porous ceramic particles to be used as a self-healing agent for the repair of cracks in reinforced concrete. Microorganism intervention promoted the complete healing of the cracks within 120 days, with a maximum repair width of 450 μm. The Tafel polarization results indicated that the concrete underwent active-to-passive transitions during the MICP process. However, MICP for corrosion protection of metallic materials has been developing in recent years. Liu et al.29 found that marine Pseudoalteromonas lipolytica could convert biofilms into biomineralized hybrid films composed of calcite and EPSs in a simulated marine medium, showing strong corrosion inhibition and self-healing activity. By comparing the wild-type strain of P. lipolytica, a strain overproducing EPSs and a strain lacking EPS production, it was confirmed that the EPS-overproducing strain had stronger corrosion inhibition, indicating that the formation of protective biomineralization films was closely related to EPSs.

In this study, the influence of biomineralization caused by S. putrefaciens on the MICI of Q235 carbon steel was investigated. The surface morphologies of Q235 carbon steel after immersion with and without S. putrefaciens were observed using scanning electron microscopy (SEM). The biofilm was evaluated using confocal laser scanning microscopy (CLSM). The MICI behaviors of the Q235 carbon steel were investigated based on measurements of weight loss, potentiodynamic polarization curves, and scanning electrochemical microscopy (SECM). The compositions of the surface product in media with and without S. putrefaciens were investigated using energy-dispersive spectrometry (EDS) and X-ray photoelectron spectroscopy (XPS). The compositions and microstructures of the mineralized particles were analyzed using X-ray diffraction (XRD) and transmission electron microscopy (TEM). Soluble iron and calcium were analyzed using inductively coupled plasma mass spectrometry (ICP-MS). The wear resistance of the mineralized layers was tracked by weight loss assays and surface morphology changes under mixed sand–water erosion conditions.

Results and discussion

Corrosion morphologies

Figure 1 shows the morphology of the surface products on the carbon steel coupon after immersion in sterile and S. putrefaciens-inoculated media for 7 and 14 days. In Fig. 1b and e, optical images of the macroscopic corrosion morphology on the 14th day are shown in the red frame. In Fig. 1b, a large number of reddish-brown corrosion products were uniformly deposited on the coupon surface. In contrast, grayish surface products instead of typical rust-like corrosion products were observed to uniformly cover the coupon surface in the S. putrefaciens-inoculated medium (Fig. 1e). The SEM images showed that a large quantity of corrosion products accumulated and formed a uniform layer on the coupon surface after immersion in the sterile medium for 14 days (Fig. 1b). In the enlarged image (Fig. 1c), it was observed that the corrosion product layer was extremely loose. The cracks observed on the surface of the corrosion product layer may result from the drying process30. In the S. putrefaciens-inoculated medium, a large number of evenly distributed particles appeared on the coupon surface after 7 days of immersion (Fig. 1d). The number of particles further increased after 14 days, and the coupon surface was completely covered by a product layer composed of these particles (Fig. 1e). In the enlarged image (Fig. 1f), the particles were observed to have rhombohedral or trigonal structures, which were stacked on top of each other to form dense mineral-like layers.

Fig. 1: SEM and optical images of the surface products on the Q235 coupons.
figure 1

a, b Q235 surface in the sterile medium after 7 days and 14 days; d, e Q235 surface in S. putrefaciens-inoculated medium after 7 days and 14 days. c Enlarged image of panel b. f Enlarged image of panel e.

Figure 2 shows the surface morphology of the Q235 coupons under different culture conditions after removing the surface product. The coupons in the S. putrefaciens-inoculated medium exhibited almost no corrosion after immersion for 7 days, and the abraded scratches on the coupon surface were visible. Even after 14 days of immersion, scratches on the coupon surface could still be observed, with only slight corrosion occurring on the local coupon surface. In contrast, serious uniform corrosion was observed on the coupons immersed in the sterile medium on the 7th and 14th days. These results indicated that the corrosion of the Q235 steel was significantly inhibited due to the presence of S. putrefaciens.

Fig. 2: SEM images of Q235 coupons after removing the surface products.
figure 2

a, b Q235 surface in the sterile medium after 7 days and 14 days; c, d Q235 surface in S. putrefaciens-inoculated medium after 7 days and 14 days.

Biofilm observation

Figure 3 shows CLSM images of the biofilms formed on the surface of the Q235 carbon steel coupon after 7 and 14 days of immersion. A large number of bacteria uniformly adhered to the Q235 steel surface. After immersion for 7 days, the biofilm thickness was ~16 μm (Fig. 3a). In Fig. 3b, the biofilm thickness on the 14th day increased to ~22 μm. Notably, the blue areas represented mineralized particles between bacterial clusters on the coupon surface (Fig. 3c, d). In the process of microbial-induced mineralization, the bacterial cell wall acts as a crystal nucleation site31. A mineralized envelope is then formed around the cell and impedes access to nutrients, which may explain the observation that a large number of dead bacteria were distributed in the biofilm on the 14th day.

Fig. 3: CLSM images of S. putrefaciens biofilms on the surfaces of the Q235 carbon steel coupon.
figure 3

a, c after 7 days and b, d after 14 days.

In the cross-sectional images, the blue signal in Fig. 3d was more intense than that in Fig. 3c, indicating that the microbial-induced mineralization layers became thicker and more uniform after 14 days of immersion. The suspended living S. putrefaciens continuously adhered to the coupon surface to form mineral layers.

Analysis of the surface products

Figure 4a, b shows the SEM images of S. putrefaciens cells on the steel surface in the early stage of immersion. After 3 days of immersion, relatively loose flaky minerals appeared on the S. putrefaciens cell wall. As the immersion time increased, the flaky minerals became very dense, and they completely wrapped the S. putrefaciens cell on the 7th day. EDS analysis (Fig. 4c, d) showed a high level of calcium in the flaky minerals on the bacterial surface. These results combined with the analysis of carbon and oxygen content indicated that the flaky minerals may be calcium carbonate. Compared with that of point 1, the calcium content of point 2 increased slightly from 18.56 to 21.92%, while the iron content of point 2 decreased significantly from 18.74 to 5.43%. Based on these results, it was evident that the mineral layers on the coupon surface were induced by S. putrefaciens, and the degree of mineralization increased with time32.

Fig. 4: SEM and EDS images of S. putrefaciens cells on the surface of a Q235 coupon.
figure 4

a Third day, b seventh day, c point 1, d point 2.

X-ray diffraction (XRD) was used to further analyze the composition of the mineral layer (Supplementary Fig. 1). The mineral particles were mechanically removed from the product layer on the coupons using a steel scraper in S. putrefaciens-inoculated medium after 14 days. According to the XRD results, the mineral particles were mainly composed of calcite. The identified peaks of calcite at 2θ values of 23.25°, 29.48°, and 36.18° correlated with lattice indices of (012), (104) and (110), respectively33,34. Figure 5 shows TEM and EDS images of a single-mineral particle35. The mineral particle had a rhombohedral structure. The selected area electron diffraction (SAED) pattern in Fig. 5b shows clear diffraction spots and fuzzy diffuse rings, which indicated that the mineral particle was a mixture of polycrystalline and amorphous structures. The high-resolution TEM analyses in Fig. 5c showed that the mineral precipitates were polycrystalline with at least three planes. The lattice spacings of the precipitates were 0.19, 0.23, and 0.29 nm, corresponding to the (116), (113), and (006) planes, respectively (Fig. 5c). The elemental maps showed that the mineral particles were dominated by C, O, and Ca, which were distributed evenly. Consistent with the XRD analysis, the lattice-spacing pattern further confirmed that the precipitates were calcite, which is the most stable crystal structure of calcium carbonate.

Fig. 5: TEM and EDS images of precipitates on the Q235 coupon after 14 days.
figure 5

a TEM and EDS images of a mineral particle from the Q235 coupon surface; b SAED pattern; c high-resolution transmission electron microscopy (HRTEM) analyses. The elemental maps show that C, O, and Ca were evenly distributed on the particle surface.

To further investigate the influence of microbiologically induced mineralization on the corrosion behavior, the high-resolution Fe2p, Ca2p, C1s, and O1s peaks of the XPS spectra of the steel coupons incubated with and without S. putrefaciens for 14 days were compared (Fig. 6). The corresponding binding energy of each compound is listed in Table 1. The high-resolution Fe2p spectra of the corrosion products of the Q235 steel in the sterile and S. putrefaciens-inoculated media are shown in Fig. 6a. The Fe2p spectra can be fitted with three peaks, namely, FeOOH, Fe2O3, and Fe3O436,37. Compared with the peak intensity in the spectrum of the steel immersed in the S. putrefaciens-inoculated medium, that in the spectrum of the steel immersed in the sterile medium was stronger, and the peak was attributed mainly to oxides and hydroxides of trivalent iron, indicating more serious corrosion. Figure 6b presents the high-resolution Ca2p spectra, and the peaks at 351.1 and 347.1 eV were assigned to calcium carbonate. The intensity of the Ca2p peak for the coupon immersed in the S. putrefaciens-inoculated medium was much stronger than that for the sample immersed in the sterile medium. These results indicated that the presence of S. putrefaciens could form mineral layers with calcium carbonate as the main component on the steel surface and could effectively inhibit corrosion. Figure 6c, d presents the high-resolution C1s and O1s spectra. The C1s spectrum could be fitted with three peaks, corresponding to C-(C, H), C-(O, N), and \({{{\mathrm{CO}}}}_3^{{{{\mathrm{2 - }}}}}\)38,39. The \({{{\mathrm{CO}}}}_3^{{{{\mathrm{2 - }}}}}\) signal peak in the S. putrefaciens-inoculated medium was mainly attributed to calcium carbonate mineral layers. In the sterile medium, the \({{{\mathrm{CO}}}}_3^{{{{\mathrm{2 - }}}}}\) signal peak may be attributed to the adsorption of \({{{\mathrm{CO}}}}_3^{{{{\mathrm{2 - }}}}}\) on the loose rust layer from the 2216E medium. Similarly, the stronger C-(C, H) signal in the sterile medium may also be attributed to the adsorption of organics from the 2216E medium. The O1s spectrum could be fitted with five peaks, namely, O2−, OH, carbonate, organic O, and H2O. The O2− peak was attributed to iron oxides in the rust layers. Its strength was obviously lower in the spectrum for the sample in the S. putrefaciens-inoculated medium, which was consistent with the results of the Fe high-resolution spectrum. Notably, the peaks of organic O and H2O were detected in the spectrum of the sample immersed in the S. putrefaciens-inoculated medium. The peak of organic O was attributed to the EPSs mixed in the mineral layer, and the H2O peak may be attributed to calcium carbonate monohydrate, which is the thermodynamic metastable phase of calcium carbonate40,41.

Fig. 6: High-resolution XPS spectra for the Q235 surface after immersion in sterile medium and in S. putrefaciens-inoculated medium for 14 days.
figure 6

ad correspond to Fe2p, Ca2p, C1s, and O1s, respectively.

Table 1 Binding energies of elements on the Q235 coupon surface from XPS.

ICP-MS

Supplementary Fig. 2 shows the concentrations of calcium ions and iron ions released from the steel coupons immersed in the sterile medium and the S. putrefaciens-inoculated medium for 3, 7, 11, and 14 days. The concentration of calcium ions in the sterile medium did not change substantially. However, the concentration of calcium ions in the S. putrefaciens-inoculated medium gradually decreased with the increase in immersion time. In the mineralization process, bacteria were used as carriers for the nucleation and growth of minerals, and their metabolites provided an environment of high local alkalinity and supersaturation of carbonate for mineral formation42. Combined with the results in Supplementary Fig. 3 indicate that the cell concentration and pH value of S. putrefaciens in the stationary phase were maintained at a high level after 7 days. In Supplementary Fig. 2a, the concentration of calcium ions in the S. putrefaciens-inoculated medium was approximately half the initial concentration on the 11th day, indicating that calcium deposition was closely related to the metabolic intensity of S. putrefaciens.

Supplementary Fig. 2b, the iron ion concentrations in the sterile medium substantially increased as the immersion time increased as a result of the corrosion of the steel surface. In contrast, the iron concentration was almost unchanged in the S. putrefaciens-inoculated medium. This indicated that S. putrefaciens effectively inhibited the dissolution of the steel, with only a small quantity of iron ions released at the beginning of immersion. When the bacterial growth reached the stationary phase, corrosion was inhibited with the maturation of the mineral layers.

Potentiodynamic polarization and weight loss measurements

Figure 7a shows the potentiodynamic polarization curves of the Q235 steel in the sterile and S. putrefaciens-inoculated media after 14 days of immersion. Compared with the steel immersed in the sterile medium, the sample in the S. putrefaciens-inoculated medium showed a significantly reduced corrosion current density (0.38 μA cm−2), which was less than one-tenth that in the sterile medium (4.86 μA cm−2). To further investigate the effect of S. putrefaciens on corrosion inhibition, the corrosion rates of the steel were determined by weight loss measurements after 3, 7, 11, and 14 days of immersion. According to Fig. 7b, the corrosion rate in the S. putrefaciens-inoculated medium was much lower than that in the sterile medium at every time point. After 14 days, the corrosion rate in the S. putrefaciens-inoculated medium (0.004 mm y−1) was also less than one-tenth that in the sterile medium (0.052 mm y−1), which was consistent with the results of the potentiodynamic polarization measurements.

Fig. 7: Evaluation of microbiologically influenced corrosion inhibition.
figure 7

a Potentiodynamic polarization curves; b corrosion rates of Q235 coupons in the sterile medium, in the S. putrefaciens-inoculated medium, and in the S. putrefaciens-inoculated medium without calcium.

To further elucidate the contribution of mineralized layers to corrosion inhibition, weight loss measurements were conducted in a calcium-free bacterial culture medium. The results showed that the corrosion was inhibited especially in the early stage (3 and 7 days) due to the presence of S. putrefaciens. However, the corrosion rates began to rise remarkably with extended immersion (11 and 14 days). In the early stage of the test, the S. putrefaciens biofilm had strong metabolic activity and can consume a large amount of dissolved oxygen, thereby suppressing the cathodic corrosion reactions. However, as the bacteria cells died after a longer culture time and the bacterial aerobic respiration intensity weakened, the corrosion rate began to increase. These results suggest that both the mineral formation and the biofilm can contribute to the mitigation of corrosion. The formation of a mineralized layer could provide longer-acting corrosion protection of the steel substrate.

Wear resistance

Wear resistance is an important property for a protective layer, especially in marine environments, where sandy seawater can easily cause erosion. The weight loss during the wear test was tracked to evaluate the wear resistance of S. putrefaciens-induced mineral layers. Figure 8a shows a schematic illustration of the wear-resistance testing equipment. The coupon was firmly adhered to the turntable and completely immersed in artificial seawater containing silica sand. The coupon was rotated at a speed of 1 m s−1 for 30-min cycles and weighed at the end of each cycle. In Fig. 8b, the weight loss was relatively fast in the first six cycles, which may be due to the weak adhesion of the mineral particles in the upper layer of the mineral layers. In the last four cycles, the erosion of the mineralized layer slowed significantly, indicating that the bottom of the mineralized layers was more cohesive and exhibited better protection performance. Supplementary Fig. 4 shows the SEM images of the Q235 coupon surface before and after the wear-resistance test. In Supplementary Fig. 4b, the surface morphology of the mineralized layer after ten cycles in the wear-resistance test was almost the same as the original morphology. The mineral particles still maintained sharp edges (Supplementary Fig. 4d). This result is consistent with the weight loss data, indicating that the mineralized layer has wear resistance43.

Fig. 8: Wear resistance of S. putrefaciens-induced mineral layers.
figure 8

a Schematic illustration of wear-resistance testing equipment; b weight loss of the coupons after different testing cycles.

In situ microbial self-healing effect of mineral layers

In actual marine environments, damage to material surfaces by mechanical and chemical attacks is inevitable. Microbial self-healing can repair the damage sustained by the protective layer and restore the physical shielding performance. Figure 9a shows the CLSM images of the surface of the mineral layers formed by S. putrefaciens, on which an artificial scratch with a width and depth of ~40 μm was made. After 7 days of immersion in the S. putrefaciens-inoculated medium, the deposition of mineral particles induced a self-healing effect of the surface morphology. The scratch region was flattened, the width of the scratch was reduced from 39.71 to 31.27 μm, and the depth of the scratch was significantly reduced from 37.84 to 13.27 μm. After 14 days, the coupon surface was almost completely repaired, with only minor traces observed at the scratch region, with a depth of only 8.34 μm (Fig. 9f).

Fig. 9: Stereo-optical micrographs and SECM images of a coating scratch during the S. putrefaciens-induced microbial self-healing process.
figure 9

a, d, g Before microbial self-healing; b, e, h immersion for 7 days in the S. putrefaciens-inoculated medium; c, f, i immersion for 14 days in the S. putrefaciens-inoculated medium.

The in situ microbial self-healing effect on the corrosion protection property of the mineralized layer was investigated by SECM, which monitored the concentration of oxygen over the scratch region. Competition between oxygen reduction at the tip of the UME and the cathodic corrosion reaction on the Q235 steel surface caused the current reduction in the SECM image44. In Fig. 9g, the current over the scratch region was sharply reduced, indicating that the oxygen in this area was almost completely consumed by the cathodic corrosion reaction on the exposed substrate. After 7 days, the scratch was covered with mineralized layers, which inhibited the progress of the cathodic reaction. In this case, the efficiency of the microbial self-healing effect, as determined by the I/Ia value at the scratch after microbial self-healing, was as high as 82%. As microbial self-healing continued, the crack was completely repaired on the 14th day.

The above results indicated that S. putrefaciens-induced mineralization plays a key role in MICI, and the mechanism of MICI is shown in Fig. 10. In the initial stage of immersion, S. putrefaciens in the logarithmic phase rapidly proliferates and secretes EPSs, which attach to the coupon surface to form biofilms. EPSs include a variety of organic macromolecules, such as proteins, polysaccharides and other substances, which can act as a physical barrier to hinder the diffusion of dissolved oxygen to the metal surface45, and the functional groups, such as −COOH, −OH, and −NH2, can be deprotonated with increasing pH, making the EPSs negatively charged overall46. These features are beneficial for the chelation of calcium ions in solution and provide a favorable local environment for biomineralization47. Under alkaline conditions, the carbon dioxide produced by aerobic respiration dissolves in water to generate \({{{\mathrm{HCO}}}}_3^ -\). S. putrefaciens uses the cell wall as the nucleation site to induce carbonate deposition to form mineralized layers. Under the condition of complete immersion, the biomineralization process impedes the diffusion of dissolved oxygen to the metal surface, and the cathode process is inhibited48. Based on the above mechanism, the microorganisms only rely on the natural environment and their own metabolism to enable corrosion inhibition without the usage/release of toxic compounds and the additional manual intervention such as those associated with conventional corrosion mitigation methods. Thus, MICI based on bacterial mineralization is environmentally friendly and conforms to the direction of the development of anticorrosion technologies, although extensive laboratory and field studies are still needed to assess its viability in real and complex environmental conditions.

Fig. 10
figure 10

Schematic illustration of the MICI mechanism via biomineralization induced by S. putrefaciens.

In summary, the influence of S. putrefaciens on the MICI behavior of Q235 carbon steel was investigated in this study. In contrast to the severe corrosion of carbon steel coupons in a sterile medium, corrosion of the coupons in an S. putrefaciens-inoculated medium was inhibited by the biomineralized layers induced by S. putrefaciens. The biomineralized layers were characterized in terms of morphology, composition, electrochemical behaviors, microbial self-healing performance and wear resistance. The following conclusions can be drawn:

  1. 1.

    According to the morphology observations, electrochemical tests, and weight loss assays, the formation of biomineralized layers induced by S. putrefaciens mitigated uniform corrosion on the carbon steel during 14 days of immersion.

  2. 2.

    The XRD, TEM, and XPS results demonstrated that the mineralized layer was a mixture of calcite and a small quantity of EPSs.

  3. 3.

    The results of wear resistance and SECM measurements indicated that the biomineralized layers induced by S. putrefaciens possessed anti-abrasive and microbial self-healing properties, and the repaired surface had the same corrosion resistance as the complete mineralized layers.

Methods

Bacteria and media

The pure S. putrefaciens strain was obtained from the Marine Culture Collection of China (MCCC). The S. putrefaciens strain was cultured in 2216E medium containing 5.0 g peptone, 1.0 g yeast extract, 0.1 g ferric citrate, 19.45 g NaCl, 5.98 g MgCl2, 3.24 g Na2SO4, 1.8 g CaCl2, 0.55 g KCl, 0.16 g Na2CO3, 0.08 g KBr, 0.034 g SrCl2, 0.08 g SrBr2, 0.022 g H3BO3, 0.004 g NaSiO3, 0.0024 g NaF, 0.0016 g NH4NO3, and 0.008 g NaH2PO4 in 1 L deionized water. The pH of the medium was 7.2 ± 0.2. The 2216E medium was sterilized at 121 °C for 20 min in an autoclave (Panasonic, MLS-3781-PC). The cell numbers of the planktonic S. putrefaciens were measured using a hemocytometer under a light microscope (Zeiss, Lab A1) at ×400 magnification.

Materials and treatment

Q235 carbon steel coupons with dimensions of 10 × 10 × 3 mm3 were used for all tests. Table 2 shows the chemical compositions (wt%) of Q235 carbon steel. All coupons were abraded sequentially with 200, 400, 600, and 800 grit sandpapers and then rinsed with ethanol, as described in the literature49. Before each experiment, all the coupons were dried under ultraviolet light for 30 minutes. Immersion testing was conducted in a conical flask containing 50 ml liquid medium50. Three identical coupons were placed at the bottom of each conical flask. The coupons were completely immersed in liquid medium and did not touch each other.

Table 2 Chemical composition of Q235 carbon steel (wt%).

Surface characterization

Before and after removing the surface products, the morphologies were observed using SEM (Hitachi, SU8010). The surface products and the biofilm were removed by means of Clarke’s solution according to ASTM G1-0351. Before observing the bacteria attached to the coupons, the coupons were fixed in 2.5% (v/v) glutaraldehyde at 4 °C overnight and dehydrated with an ethanol gradient (50, 70, 85, 95, and 100 vol.%) to maintain the original morphology of the bacteria. The coupons were sputter-coated with Au to improve the surface conductivity before SEM observations. The biofilm on the coupon surface was observed using CLSM (Leica, TCS SP8) after live/dead fluorescent staining. The live and dead cells appeared green and red, respectively, as a result of SYTO-9 and propidium iodide (PI) dyes (Thermo Fisher, LIVE/DEAD™ BacLight™ Bacterial Viability Kit)52. The chemical compositions of the surface product layers were analyzed using X-ray diffraction (XRD, D8 Advance, Bruker) and XPS (Thermo Fisher, ESCALAB 250Xi). To evaluate the self-healing performance of S. putrefaciens, CLSM (Kenyence, VK-X260K) was used to observe the morphology of artificial defects before and after microbial self-healing.

Electrochemical measurements

Electrochemical measurements were performed using an electrochemical station (Gamry, Reference 600 Plus). The electrochemical behaviors of the Q235 carbon steel were evaluated using a traditional three-electrode system consisting of a Q235 coupon as the working electrode, platinum foil as the counter electrode, and a saturated calomel electrode (SCE) as the reference electrode. Before each electrochemical test, the open circuit potential (OCP) was measured for no less than 10 min to ensure measurement stability. Potentiodynamic polarization curves were obtained after 14 days of immersion in sterile and S. putrefaciens-inoculated media, and the scanning potential range was from −200 mVSCE to +200 mVSCE vs. OCP at a scanning rate of 0.166 mV s−1.

SECM measurements were performed using a microelectrochemical station (CH Instruments, 920D). The measurements were conducted by means of a four-electrode system consisting of the traditional three-electrode system and a platinum ultramicroelectrode (UME) as another working electrode53. The UME was composed of a platinum wire with a diameter of 10 μm encapsulated in a borosilicate glass capillary. According to the approach curve, the distance between the UME probe tip and the coupon surface was maintained at 25 μm. The probe was scanned on the XY plane over an area of 300 × 500 μm2 at a scanning rate of 50 μm s−1. In redox competitive mode, a constant potential of −0.6 V (Ag/AgCl) was applied to the probe tip to collect oxygen reduction signals. The oxygen reduction current (I) obtained in the artificial crack region was normalized to the current (Ia) obtained over the intact region54. The I/Ia values were used to evaluate the healing efficiency.

Weight loss assay and ICP-MS

Before the immersion tests, all coupons were weighed and recorded using an electronic balance (ME204, Mettler Toledo). After immersing the coupons for different times and removing the surface products according to ISO 8407, the coupons were rinsed with deionized water, dried with nitrogen and weighed again55. The uniform corrosion rate (mm y−1) was calculated from the weight loss data using the following equation:

$$V_{corr} = \frac{{8.76 \times 10^4 \times {\Delta}m}}{{\rho At}}$$
(1)

where Vcorr is the corrosion rate (mm y−1); ρ is the coupon density (g cm−3); A is the exposed coupon area (cm2); t is the testing time (h); and Δm is the difference between the weights of the coupon before and after immersion.

The concentrations of calcium and iron ions in the medium were evaluated using ICP-MS (Thermo Scientific, iCAP TQs). Sterile and S. putrefaciens-inoculated media with different immersion times were pretreated with concentrated nitric acid and then tested.

Wear-resistance test

The wear resistance of the mineral layers on the Q235 carbon steel coupons was evaluated using abrasive erosion testing equipment56. A sand–water mixture with a mass ratio of 1:20 was added to the water tank. The coupons were firmly glued to the edge of the rotating disk of the equipment, and the coupon working surface was perpendicular to the ground. During the test, the disk was rotated at a constant linear velocity of 1 m s−1 in 30-min cycles. After completing each cycle, the coupons were removed from the equipment, washed with deionized water, dried with nitrogen, and weighed. The wear resistance of the mineral layers was evaluated in terms of weight loss. Before the wear-resistance test, the original weight of the coupons with mineral layers was determined by means of an electronic analytical balance with a precision of 0.1 mg. After each cycle, the coupons were washed with deionized water and ethanol, dried with nitrogen, and weighed.