Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Comment
  • Published:

Dental implants

Can narrow-diameter implants enhance patient-reported outcomes for mandibular implant-retained overdentures?

Abstract

Study design

A systematic review and meta-analysis.

Objective

To evaluate and compare stability and functionality between narrow and standard implant-retained mandibular overdentures in edentulous patients from multiple perspectives. Assessments included clinical parameters [survival rate (SR) and marginal bone loss (MBL)], along with patient-reported outcome measures (PROMs) including patient satisfaction and oral health-related quality of life (OHRQoL).

Methods

The study protocol followed PRISMA criteria for reporting reviews and meta-analyses. Using appropriate keywords, electronic search was conducted in each of the following databases: Medline, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus, up to July 22, 2022. There were no restrictions based on language, publication type, or publication date. Additionally, ongoing studies were explored in ClinicalTrials.gov and WHO ICTRP, while cross-references in each selected study were manually examined. The eligible studies were randomized controlled trials (RCTs) or controlled clinical trials (CCTs) comparing narrow implants (diameter ≤ 3.5 mm) to standard implants (diameter > 3.5–4.5 mm) retaining mandibular overdentures in edentulous patients. Excluded were studies with unclear implant diameter information, fewer than 5 patients per group, observational studies, reviews, and laboratory studies. Two authors independently conducted study selection, data collection, and analysis, resolving any discrepancies through discussion with a third author. Methodological quality was assessed using RoB-2 and ROBINS-I tools. Implant SR and MBL measurements at final follow-up were recorded, while patient satisfaction and OHRQoL were evaluated using visual analogue scale (VAS-100) and oral health impact profile (OHIP) questionnaire, respectively.

Results

After duplicate removal, 782 publications and 83 registered clinical trials were identified, of which 26 were eligible for full-text assessment. Ultimately, the quantitative evaluation included 12 publications from 8 independent studies: 4 parallel design RCTs and 4 CCTs. Risk of bias assessment revealed variations among the studies, with only one study being rated as having low risk. The follow-up periods ranged from 1 to 3 years. Meta-analysis showed no significant difference in SR and MBL between narrow and standard implant groups (p = 0.29 and p = 0.93, respectively), with considerable heterogeneity (I2 = 100% and I2 = 78%, respectively). Regarding PROMs, the narrow implant group showed significantly higher levels of patient satisfaction (mean difference (MD): 8.18; 95% CI: 5.83 to 10.53; p < 0.00001; I2 = 36%) and exhibited a significant improvement in OHRQoL (MD: −4.36; 95% CI: −6.83 to −1.89; p < 0.001; I2 = 55%) compared to the standard implant group.

Conclusion

For implant-retained mandibular overdentures, the use of narrow implants is associated with comparable SR and MBL, along with higher patient satisfaction and better OHRQoL improvement as compared to standard implants, offering a viable alternative option for patients with diminished alveolar bone width.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

References

  1. Schierz O, Reissmann DR. Dental patient-reported outcomes—the promise of dental implants. J Evid Based Dent Pract. 2021;21:101541.

    Article  PubMed  Google Scholar 

  2. Majid OW. Submucosal dexamethasone injection improves quality of life measures after third molar surgery: a comparative study. J Oral Maxillofac Surg. 2011;69:2289–97.

    Article  PubMed  Google Scholar 

  3. Majid OW, Al-Mashhadani BA. Perioperative bromelain reduces pain and swelling and improves quality of life measures after mandibular third molar surgery: a randomized, double-blind, placebo-controlled clinical trial. J Oral Maxillofac Surg. 2014;72:1043–8.

    Article  PubMed  Google Scholar 

  4. Slade GD, Spencer AJ. Development and evaluation of the oral health impact profile. Community Dent Health. 1994;11:3–11.

    CAS  PubMed  Google Scholar 

  5. Hebling E, Pereira AC. Oral health-related quality of life: a critical appraisal of assessment tools used in elderly people. Gerodontology. 2007;24:151–61.

    Article  PubMed  Google Scholar 

  6. Kutkut A, Bertoli E, Frazer R, Pinto-Sinai G, Fuentealba Hidalgo R, Studts J. A systematic review of studies comparing conventional complete denture and implant retained overdenture. J Prosthodont Res. 2018;62:1–9.

    Article  PubMed  Google Scholar 

  7. Storelli S, Caputo A, Palandrani G, Peditto M, Del Fabbro M, Romeo E, et al. Use of narrow-diameter implants in completely edentulous patients as a prosthetic option: a systematic review of the literature. Biomed Res Int. 2021;2021:5571793.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Park JH, Shin SW, Lee JY. Narrow-diameter versus regular-diameter dental implants for mandibular overdentures: a systematic review and meta-analysis. J Prosthodont. 2023;32:669–78.

    Article  PubMed  Google Scholar 

  9. Majid OW. Does flapless immediate implant placement lead to significant preservation of buccal bone compared to flap surgical protocol? Evid Based Dent. 2024;25:9–10.

    Article  PubMed  Google Scholar 

  10. Majid OW. Dose- and time-dependent association of smoking and its cessation with risk of peri-implant diseases. Evid Based Dent. 2024;25:15–6.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Omer Waleed Majid.

Ethics declarations

Competing interests

The author declares no competing interests.

Additional information

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Majid, O.W. Can narrow-diameter implants enhance patient-reported outcomes for mandibular implant-retained overdentures?. Evid Based Dent (2024). https://doi.org/10.1038/s41432-024-01017-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1038/s41432-024-01017-3

Search

Quick links