Introduction

Strain and pressure sensors that are mechanically flexible, bendable, and stretchable are capable of being mounted on clothes and skin. These non-planar and deformable surfaces have attracted significant interest due to their potential for application in the detection of various physiological activities, health care monitoring, human motion detection, and diagnosis1,2. Numerous sensors have been demonstrated. The three major mechanical-to-electrical conversion principles are the capacitance3,4,5,6,7,8, piezo-electricity9,10, and piezo-resistivity11,12,13,14,15,16,17. Piezo-based sensors rely upon either electrical voltage or resistance changes under mechanical deformation. For instance, high-performance piezo-resistivity in 1D or 2D nanomaterials with efficient pressure-sensitive percolation of their networked structures upon pressure application has been employed. This property gave rise to a high pressure sensitivity12,13,14. On the other hand, capacitive sensors utilize capacitance changes in pressure-sensitive dielectric films under mechanical stimuli. These sensors are advantageous owing to their fast response times and compact circuit layouts with vertically stacked device architectures3,4,5,6,7. To make these sensors suitable for various applications, particularly for largely deformable strain detection, the sensing materials should be either elastomeric or efficiently embedded in a rubbery matrix. These requirements make the sensors tolerant to repetitive deformation6,7,8. Numerous previous works have been devoted to developing elastomer-based dielectrics for enhancing the sensitivity through efficient large-scale integration by combining a variety of structural architectures3,4,5,8. These efforts have provided data supporting the relevance of these capacitive sensors. The sensor functionality was, however, limited to pressure and strain detection, thus precluding the realization of an interactive sensing capability that converts the stimulus to a human-readable output.

The visualization of either a pressure or a strain source while sensing it can further extend the usefulness of a sensor by offering novel functions, such as shape and position recognition of a strained object and time-dependent motion monitoring of an object on a sensor3,5,6,9,10,14,17. This approach, commonly studied in the area of stimuli-interactive displays, utilizes the active matrix circuitry associated with active circuit elements such as transistors to provide precise spatial recognition3. For instance, tunable coloration/light emission have been successfully demonstrated by combining optical elements with pressure sensors, allowing for the visualization of pressure; examples include organic light emitting diodes (OLEDs)18 and electroluminescent19, electrochromic20, thermochromic21,22, and triboelectrification devices23. The visualization of a large strain of over 50% is required for wearable and skin-mountable sensors. However, this visualization is not straightforward and is possible with only a few mechanochromic systems that are sufficiently resistant to repetitive large strain deformation24,25. Despite the great success in visualizing large strain with mechanochromic films, no work has combined these films with electrically detectable strain sensors and human motion detection.

When a photonic crystal (PC) consisting of a periodic lattice arrangement of two different optical components is altered by strain, its structural colors (SCs) arising from the constructive interference of light with the periodic structure can be strain-dependent. This property gives rise to a useful method for the low-power reflective mode visualization of strain (Table S1, Supporting information)24,25,26,27,28,29,30,31,32,33,34,35. In particular, SCs based on self-assembled block copolymers (BCPs) are more suitable, as their periodicities and dielectric constants are readily changed by mechanical forces such as shear, tensile, and compressive forces24,25,29. For instance, a BCP film with a non-volatile plasticizing solvent as a domain swelling agent was successfully responsive to an approximately 100% strain imposed on the film24. We envisioned that a previously developed BCP soft solid with visible-range SCs36 could be suitable as the visualization component in a mechanically deformable large strain sensor when a thin, soft BCP SC film is appropriately embedded in an elastomeric medium. This approach is widely used to detect strain based on the strain-dependent capacitance change.

Here, we present a highly stretchable capacitive sensor with the ability to simultaneously visualize strain. For the visualization of the strain, a mechanochromic bilayer of ionic gel (IG) containing an ionic liquid as a BCP domain swelling agent and a BCP SC soft solid film with 1D periodic lamellae whose surface normal is perpendicular to the film surface is embedded in an elastomeric poly(dimethyl siloxane) (PDMS) polymer. Our device consisting of three vertically stacked components (hydrogel ionic conductor/BCP SC:IG in PDMS/hydrogel ionic conductor) successfully responds to strain through a strain-dependent capacitance change of the BCP SC:IG in the PDMS layer. At the same time, the BCP SC:IG film is strain-responsive. This property arises from an efficient change in the 1D lamellae structure under strain. The initial red SC of the sensor blueshifts and turns blue when fully stretched. This change gives rise to a full-color SC alteration as a function of strain. Our BCP SC strain sensor exhibits a fast strain response with a multi-cycle reliability in both the capacitance and the SC change over 1000 cycles, allowing for convenient visible recognition of finger bending, localized pressure and the shape of a strained object.

Materials and methods

Materials

A symmetric polystyrene-b-poly(2-vinylpyridine) (PS-b-P2VP) block copolymer was synthesized via sequential living anionic polymerization in tetrahydrofuran (THF) at −78 °C using sec-butyllithium as an initiator37. The number-average molecular weight (Mn) and polydispersity index (PDI = Mw/Mn), characterized by size-exclusion chromatography (SEC), were measured to be 130 kg mol−1 and 1.03, respectively, as shown in Fig. S1. The PS volume fraction (fPS) of the BCP were determined to be 0.51 by 1H nuclear magnetic resonance (1H NMR) spectroscopy (Fig. S2) based on the mass densities of the two blocks (1.05 and 1.14 g cm−3 for PS and P2VP, respectively). Propylene glycol monomethyl ether acetate, chloroform, bromoethane, hexane, 1,4-dibromobutane, and acetonitrile were purchased from Sigma-Aldrich. Poly (vinylidene fluoride-trifluoroethylene-chlorofluoroethylene) (PVDF-TrFE-CFE) containing 8 wt% CFE was purchased from Piezotech. Acrylamide (AAm; Sigma, A8887), N,N-methylenebisacrylamide (MBAA; Sigma, M7279), N,N,N′,N′-tetramethylethylenediamine (TEMED; Sigma, T7024), ammonium persulfate (AP; Sigma, A9164), and lithium chloride (LiCl; Sigma, L4408) were also purchased from Sigma-Aldrich and used to fabricate a hydrogel. VHB 4905 was purchased from 3 M and used as received

Preparation of BCP SC:IG Bilayers

BCP SC films were prepared by spin-coating PS-b-P2VP block copolymer solutions (7 wt% in propylene glycol monomethyl ether acetate) onto silicon wafers. The films were subsequently solvent-annealed in chloroform vapor at 60 °C for 12 h. The P2VP domains of the BCP films were then selectively quaternized using 1-bromoethane and 1,4-dibromobutane in hexane at 60 °C for 24 h. The initial stopband of the BCP SC film was controlled by the degree of quaternization and the amount of 1,4-dibromobutane used during the quaternization process. IG layers consisting of PVDF-TrFE-CFE and Li+TFSI− were prepared by spin-coating onto a BCP film at 2000 r.p.m. for 60 s.

Preparation of BCP SC:IG Embedded in PDMS

PDMS with a curing agent ratio of 20:1 was poured into half of a mold (width: 15 mm, length: 70 mm, thickness: 1 mm) and pre-cured at 80 °C after removing the bubbles with a vacuum pump. A BCP SC:IG layer was transferred to the pre-cured PDMS. Additional PDMS was subsequently poured onto the BCP SC:IG layer on the pre-cured PDMS followed by thermal curing at 80 °C for 3 h.

Fabrication of the BCP strain sensor

The hydrogel was prepared as reported in the previous paper7. The bottom ion-conductive hydrogel was cut into the desired shape and carefully placed on a VHB film. A BCP SC film embedded in PDMS was attached to the hydrogel. The top ion-conductive hydrogel was placed on the BCP SC:IG in PDMS, followed by attachment of another VHB layer to the top hydrogel to prevent the evaporation of water from the hydrogels.

Characterization and Instrumentation

The cross-sectional morphologies of the 1D in-plane lamellar structures in the BCP SC:IG in PDMS were imaged by TEM (JEM-F200) with thin cross-sectional samples prepared by a focused ion beam (FIB-4601F). 2D SAXS measurements were performed with 10 BCP SC films vertically stacked on each other to obtain a sufficient X-ray scattering intensity using the PLS-II 9 A U-SAXS beamline at the Pohang Accelerator Laboratory. Reflectance spectra were taken by a UV-vis pectrometer (Ocean Optics USB2000, Filmetrics F40, and LAMBDA 750). A lab-made metal frame was used to stretch the BCP SC sensors during the reflectance measurements. The capacitance change measurements of the BCP SC strain sensors were performed with a precision LCR meter (Agilent E4980A) under ambient conditions. For the strain-dependent capacitance change measurements, a computer-controlled universal manipulator (Teraleader) was set up with the LCR meter.

Results and discussion

Design and fabrication of a BCP SC strain sensor

Our BCP SC strain sensor possesses a conventional capacitor structure with a mechanically responsive BCP SC:IG film in PDMS between two ion-conductive hydrogel electrodes physically protected with elastomeric VHB, as shown in Fig. 1a. The development of a BCP SC:IG film in PDMS started with fabricating a 1-μm-thick poly(styrene-block-2vinyl pyridine) (PS-b-P2VP) film with lamellae comprised of alternating PS and P2VP domains. A BCP solution in propylene glycol monomethyl ether acetate (PGMEA) was spin-coated. This step was followed by solvent annealing with chloroform vapor for 12 h, which gave rise to a film with highly ordered in-plane lamellae. Transmission electron microscopy (TEM) confirmed the formation of a stacked in-plane lamellae structure with a periodicity of approximately 60 nm (Fig. S3, Supporting information). Based on the nearly symmetric composition, both the PS and P2VP layers were 30 nm thick.

Fig. 1: a Schematic illustration of a BCP SC strain sensor.
figure 1

The sensor consists of VHB/hydrogel/BCP SC:IG in PDMS/hydrogel/VHB. Photograph of a cross-section of the sensor showing the layers vertically stacked on each other (right). b SEM image of a cross-sectioned BCP SC:IG in PDMS layer. The periodic BCP lamellae with the swollen QP2VP domains containing IL are visualized in the magnified images (right). c Schematic of the cross-section of a BCP SC:IG in PDMS layer. d UV-vis spectrum of a BCP SC sensor with its initial stop-band at a maximum wavelength of 650 nm. e 2D SAXS pattern of BCP SC films embedded in PDMS with the incident beam perpendicular to the surface normal of the films. To achieve a sufficient scattering intensity, 10 BCP films were stacked on each other. On the right-hand side, a plot of the scattering intensity vs. the scattering vector qz is shown. f Schematic representing the variation in the SC of a BCP SC:IG film embedded in PDMS as a function of strain

On the BCP film, which was quaternized and partially cross-linked through the pyridine rings of the P2VP blocks with a mixture of bromoethane and dibromobutane in hexane, a 3-μm-thick IG layer was coated on a poly(vinylidene fluoride-co-trifluoroethylene-co-chlorofluoro ethylene) (PVDF-TrFE-CFE) film containing a quaternized P2VP domain swelling agent, Li+TFSI−36. The degree of cross-linking of the quaternized P2VP (QP2VP) domains was determined by the amount of dibromobutane. The characteristic SC of the BCP SC:IG film instantly appeared and was dependent upon not only the amount of Li+TFSI− in the IG layer but also the fraction of dibromobutane (Fig. S4, Supporting information). The BCP SC:IG film was subsequently embedded in an approximately 1000 μm thick PDMS layer. A cross-section of the BCP SC:IG film embedded in PDMS prepared by a focused ion beam shows the periodic in-plane BCP lamellae with highly swollen QP2VP domains containing ionic liquid, as shown in Fig. 1b. The BCP SC:IG film embedded in PDMS is schematically illustrated in Fig. 1c. To electrically address the capacitance change of the PDMS containing the BCP SC:IG film under strain, two mechanically stretchable and ion-conductive hydrogel layers were placed on the top and bottom of the PDMS layer. Finally, the multilayered hydrogel/BCP SC:IG in PDMS/hydrogel structure was completely sealed in another rubbery matrix of VHB to prevent the evaporation of water from the hydrogel.

To utilize the full visible color range of the SC under strain, we initially tuned the SC of the BCP film to red with a wavelength at the maximum reflectivity of approximately 650 nm, as shown in Fig. 1d. The average domain size of the swollen QP2VP of approximately 220 nm matches well to our finite-difference time-domain (FDTD) simulation in which the maximum reflection occurs at approximately 650 nm with periodic domains of QP2VP and PS of 220 and 30 nm, respectively36. The in-plane BCP lamellae were also confirmed by 2D small-angle X-ray scattering (SAXS) in transmittance mode, as shown in Fig. 1e. Spot-like multiple reflections appeared, which correspond to the 2nd-order, 3th-order, 4th-order, 5th-order, and 6th-order reflections at scattering vectors of approximately 0.050, 0.0769, 0.1028, 0.1273, and 0.153 nm−1, respectively, at the meridian of the 2D SAXS pattern. The first-order refection was rarely detected because of parasitic scattering near the incident beam at very low q regimes and was located at a scattering vector of approximately 0.025, giving rise to expected values of the relative peak positions of the high-order reflections with respect to the first peak position (qn/q1) of 1, 2, 3, 4, 5, and 6. The (100) plane distance obtained from 2π/q1 was 251 nm, which corresponded to the periodicity of the in-plane lamellae. This result was consistent with the microscope results shown in Fig. 1b. Note that to obtain sufficient scattering intensity, 10 layers of the BCP films swollen with ionic liquid were carefully stacked after removing the IG layers (Fig. S5, Supporting information). Our BCP SC strain sensor was then subjected to various mechanical deformations that could be quantitatively evaluated in terms of capacitance and SC changes, as schematically illustrated in Fig. 1f. The capacitance increased due to the decrease in the film thickness of the PDMS, and the stopband of the BCP SC blueshifted due to the decrease in the periodicity of the lamellae. One can anticipate that the capacitance change under strain may be dominated by dimensional changes in PDMS, which is 250 times thicker than the BCP SC:IG layer.

Capacitive strain-sensing performance of a BCP SC sensor

First, the capacitive sensing properties of our BCP SC sensor were examined, and the results are shown in Fig. 2. A capacitance change was observed in the sensor containing an approximately 4 μm thick BCP SC:IG film embedded in a 1000 μm thick PDMS with strain, as shown in Fig. 2a. The gauge factor (GF) of the device was evaluated as a function of strain, which is defined as GF = δ(∆C/C0)/δε, where ε is the applied strain, and C and C0 are the initial capacitances with and without applied strain, respectively. The results show that our sensor is capable of sensing a broad range of strain with a linear capacitance change as a function of the strain. The GF value from the slope of the capacitance-strain plot was approximately 0.6, which is similar to those obtained in previous capacitive strain sensors based on dielectric rubbers such as PDMS6. Our BCP SC strain sensor promptly responds to consecutive multiple strains at 25% with fast response and relaxation times (~80 msec), as shown in Fig. 2b. The capacitance change response of our sensor to strain was sufficiently sensitive to detect knee and elbow motions in real time (Fig. S6, Supporting information). Figure 2c shows the repetitive capacitance cycling of the sensor under various applied strain ranges of 20, 50, and 100%. We also evaluated the switching time constants as a function of the strain, and the results show that the time constants rarely change with strain (Fig. S7, Supporting information). Our device shows reliable capacitance response behavior during multiple strain/release cycles, in which the capacitance change was minimally altered, even after 5000 cycles with 50% strain, as shown in Fig. 2d.

Fig. 2: a Plot of the capacitance vs. strain for a BCP SC sensor.
figure 2

b Capacitance change under 25% strain with time. The insets show that the capacitance changes upon both stretching and release occur within 80 msec. c Capacitance changes during repetitive variations in the strain from 20 to 100%. d Endurance of the capacitance change during more than 5000 50% stretch/release cycles

Visualization of strain by BCP SC

A BCP SC:IG film embedded in PDMS allows for facile visible color sensing based on its SC change, which arises from dimensional changes in the self-assembled lamellae under strain. This change gives rise to direct strain visualization simultaneously with capacitive sensing of the strain, as shown in Fig. 3. A sensor that exhibited an initial red SC with a maximum reflectivity at a wavelength of approximately 650 nm was stretched at a rate of approximately 0.05 cm/s. Our sensor was readily stretched up to approximately 100% and above, where it started to tear. The SC of the sensor clearly blueshifted with strain, as shown in the UV-vis reflectivity results provided in Fig. 3a. The applied strain exerted compression in the direction normal to the plane of the strain, which led to a decrease in the BCP SC:IG film thickness in PDMS. The wavelengths at the maximum reflectivity were plotted as a function of strain, and the results in Fig. 3b show that the values almost linearly decreased with the strain in the visible range. It should be noted that while the shift in the maximum position under strain mainly arises from the change in the average periodic distance of a BCP nanostructure under strain, the reflectance change is more complicated because it is affected by various factors, such as the local film thickness variation and local scattering. In fact, we employed an optical fiber-type UV-vis spectrometer to characterize a small area of approximately 0.01 mm2 of the film. As described later, our BCP SC film contained numerous structural defects consisting of screw dislocations unevenly distributed in the film. The local scattering resulting from the screw dislocations was not uniform, and the film thickness also varied from point to point due to the unevenly distributed screw dislocations, giving rise to the variations in the reflectance.

Fig. 3: a Reflectance spectra of a BCP SC sensor as a function of strain.
figure 3

The initial BCP SC without strain, which exhibits a wavelength at the maximum reflection of approximately 650 nm, blueshifted with strain. b Plot of the wavelength at the maximum reflection as a function of strain. c Photographs of the sensor as a function of strain. All scale bars represent 1 cm. d Wavelengths at the maximum reflection during repetitive stretching (100% strain) and release cycles. e Variation in the wavelength at the maximum reflection with repetitive stretching (100% strain) and release cycles. f 1D SAXS plots of the scattering intensity vs. the scattering vector qz of BCP SC films under different strains. To achieve a sufficient scattering intensity, 10 BCP films were stacked on each other. g Periodicities of the BCP lamellae under strains of 0, 50, 100, and 0%

The representative photographs of the sensor under the corresponding strain shown in Fig. 3c clearly suggest that the full visible range can be utilized for sensing a large strain of up to 100%. It should also be noted that the local variations in the BCP SC observed in the photographs was mainly due to the presence of non-uniform BCP SC films. In fact, a completely flat and uniform BCP SC film was difficult to obtain during the transfer process in which a film prepared on a Si substrate was transferred to a PDMS layer, and instead, locally crumpled and irregular films were often achieved, giving rise to non-uniform SC, as shown in Fig. 3c. Another reason for the non-uniform SC is due to the screw dislocations that were unevenly distributed in the film, creating randomly located microscale cracks during repetitive strain events, as described in a later section. Our sensor was reliably stretched to 100% and repeatedly recovered to its original shape. This cycle gave rise to repetitive switching of the SC from red to blue during multiple strain/release cycles, as shown in Fig. 3d. A reliable SC change during consecutive strain/release cycles was observed, as shown in Fig. 3e, where the initial SC with a wavelength at the maximum reflectivity of 650 nm barely changed during the 100 strain/release cycles. No significant degradation of the SC was observed, even after 1000 deformation cycles (Fig. S8, Supporting information).

To confirm that a decrease in the domain size occurred due to the external strain, SAXS experiments were performed, and the results are shown in Fig. 3f, g. 1D plots of a BCP SC in PDMS as a function of the strain obtained from the 2D SAXS results (Fig. S9, Supporting information) clearly show that the set of reflections shifted to higher q values with strain. This indicates a decrease in the periodicity of the BCP film with strain. When the strain was released from the BCP film, the set of reflections recovered its original state without strain. It should be again noted that the first-order reflection peaks of the film under strain could not be detected because of parasitic scattering near the incident beam at very low q regimes. The lamellar periodicity values from the first-order reflections with different strains were 251, 196, and 174 nm for strains of 0, 50, and 100%, respectively. The film after removing the strain exhibited as lamellar periodicity of 246 nm, as shown in Fig. 3g.

Mechanism of the reversible visualization of strain in the BCP SC strain sensor

The linear variation in the SC of the BCP SC:IG film with strain and the SAXS results suggest that affine deformation occurred in our sensor, and thus, the BCP lamellae with their initial periodicity decreased accordingly with the macroscopic strain. It is surprising that the periodic lamellae, particularly those having glassy PS domains that are minimally deformable with strain, underwent reversible large strain deformation. We revealed that the reversible deformation of the BCP films was attributed to two main factors: (1) the unique geometry of our BCP SC sensor, in which a BCP SC:IG film was embedded in an elastomeric PDMS and (2) the presence of an ionic liquid in the QP2VP domains. Note that all of the following experiments were carried out after removing the IG layer to clearly elucidate the deformation of the BCP film. A BCP film placed on a PDMS substrate without the ionic liquid was severely torn when stretched up to 100% strain in addition to the characteristic buckled structure with a periodicity of approximately 100 microns, as shown in Fig. 4a. When stretched by strain εs, a BCP film was compressed perpendicular to the strain direction (Fc), resulting in a buckled structure along the strain direction in some areas. When released to the 0% strain state, another compressive force was exerted in the film parallel to the initial strain direction. A secondary buckled structure occurred in the film perpendicular to the compressive force. In contrast, mechanical failure was significantly reduced to give a buckled structure finer than that on PDMS when the BCP film was embedded in PDMS, as shown in Fig. 4b. This result implies that the confinement of the BCP film is beneficial for mitigating the mechanical failure of the film. The two types of buckled structures were also observed during stretch and release cycles.

Fig. 4: OM images of (a) a BCP film containing no ionic liquid on PDMS, (b) a BCP film containing no ionic liquid embedded in PDMS and (c) a BCP film containing ionic liquid embedded in PDMS and the film stretched with a strain of 100% (left) and released to a strain of 0% (right).
figure 4

All of the scale bars in the OM images represent 100 μm. SEM images of (d) the in-plane, (inset) inclined, and (e) cross-sectional views of a BCP film containing ionic liquid embedded in PDMS after a 100% stretching and release cycle. The characteristic micron-scale buckled structure that developed both parallel and perpendicular to the stretching direction is shown. f TM-AFM image in height contrast of a BCP SC film before stretching. The screw dislocations that act as channels for transporting the ionic liquid into the QP2VP domains are apparent

More importantly, the ionic liquid that is miscible with the QP2VP domains and causes them to swell plays a key role in reducing the mechanical failure during repetitive strain/release cycles when combined with the aforementioned unique confined geometry of the BCP film. Since the QP2VP domains become elastic due to the plasticization of the polymers with ionic liquid4,38, no large fracture of the film was observed, and the buckled structure was much finer when a BCP film with ionic liquid embedded in PDMS was stretched to 100% strain than that without ionic liquid, as shown in Fig. 4c. The secondary buckled structure also developed and was again much finer than that without ionic liquid, giving rise to two characteristic types of micro-buckled structures, as shown in Fig. 4d. A cross-sectional view of a deformed BCP film with ionic liquid also reveals a few-micron-scale buckled structure, as shown in Fig. 4e. A micro-buckled lamellae structure after the stretch/release cycle was also observed in the SAXS results, in which more broad reflections were observed after the cycle than for a film before deformation (Fig. S6, Supporting information). The film with the fine texture remained even after multiple strain/release cycles. This feature allowed for reliable and cyclic SC modulation.

What remains unclear is how the glassy PS domains periodically placed between the elastic QP2VP domains containing ionic liquid reliably respond to the 100% large strain/release cycles. The affine deformation of the PS domains that are immiscible with the ionic liquid is not plausible, and an alternative mechanical response to the strain should be proposed to explain the reversible SC modulation. In our BCP SC:IG film, the ionic liquid preferentially diffuses into the QP2VP domains proceeding from the top to the bottom of the micron-thick BCP film. The transport across the alternating PS and QP2VP in-plane layers occurs via the vertically oriented screw dislocations created while preparing the IG layer on the BCP layer. In our previous work, numerous screw dislocations a few micrometers in size developed in a BCP film39. When mechanical tensile stress is applied to a ductile film on an elastic substrate, the microcracks will deform slowly and withstand repeated loading and unloading cycles40. We speculate that the centers of individual dislocations, which serve as channels for the ionic liquid, are responsible for efficient release of the mechanical stress exerted on the PS domains. Since mechanical rupture of the PS domains around the screw dislocations can occur rather evenly throughout the film under strain, it can be fully recovered when the strain is removed. We also identified the presence of screw dislocations a few micrometers in size uniformly distributed in the BCP film after detaching the IG layer from the BCP film, as shown in Fig. 4f. The micron-scale buckled structure may arise from the presence of screw dislocations in the film.

Simultaneous sensing and visualization of external stimuli

The great advantage of our BCP SC strain sensor lies in the fact that the strain exerted on the device can be directly visualized through the SC over a large strain. For instance, the large strain arising from a finger bending motion was readily detected via a capacitance change (Fig. 5a) with the clear visualization of the strain on the sensor, which changed from red to green with the bending strain, as shown in Fig. 5b. Another example of both sensing and visualization of large strain induced by pressure was demonstrated with our BCP SC sensor wrapped around a push-pull gauge with different forces, as shown in Fig. 5c. A blueshift in the sensor was observed due to the large strain. When our sensor that includes a BCP SC film is bent, the region of the film above the neutral plane is stretched, while that below the neutral plane is compressed. The SC usually blueshifts, which is mainly due to the stretching of the upper regions since compression rarely alters the BCP structure. The inconsistency in the SC around the circular lines with the largest strains in Fig. 5c arises mainly from the non-uniform strain applied to the BCP SC film (Fig. S10, Supporting information). At the same time, the capacitance properly responded to two forces of 4 and 8 N, which again showed corresponding SCs of orange/green and blue, respectively.

Fig. 5: a Capacitance changes upon multiple finger bending/release motions.
figure 5

b Photographs showing a BCP SC sensor mounted on a finger upon finger bending and release. c Photographs of a BCP SC sensor with an area of 3 × 3cm2 wrapped around a push-pull gauge with a pressure of 0, 4 and, 8 N. The capacitance changes upon wrapping with 4 and 8N are shown in the plots on the right. d Photographs showing the device (c) strained by an 8N pressure at different positions. The capacitance changes during the events corresponding to 1, 2, 3, and 4 in the photographs on the left are shown on the right. e Photographs showing the devices pressurized with 4 different rubber stamps. The capacitance changes during the events on the left are shown on the right. All scale bars in (b), (c), (d) and (e) represent 1 cm

Direct visualization of strain by our BCP SC sensor is also advantageous because it offers a convenient way to obtain positional information of strained areas without pixelated sensing arrays. Four different positions were pressed with a push-pull gauge having a contact area of approximately 0.0625 π mm2 with the same pressure. While the capacitance change for all 4 pressing events was very similar due to the application of the same strain on the BCP SC sensor, the locations of the areas deformed by the cylinder were clearly visualized through the SC, as shown in Fig. 5d. We also designed topographic clover, tree, star and stick rubber stamps with similar areas. When these stamps were gently touched to a BCP SC sensor with an area of 9 cm2, both capacitance and SC information were obtained. Figure 5e shows that the four different shapes were clearly visualized in the SC (left images in Fig. 5e), while no significant difference was observed in the capacitance since there was no pressure difference. The SC-based position and shape recognition is one of the most unique properties of our BCP SC sensor, which conventional strain sensors do not possess (Table S2, Supporting information). Our simple but robust BCP SC sensor based on a low-power reflective mode displays a promising capability to directly visualize the spatial distribution of strain on a single device. On the other hand, conventional strain visualization requires high-density pixel arrays in display elements with complicated circuit integration to individually address spatial strain distributions.

Conclusion

We demonstrated that a novel BCP SC strain sensor is capable of electrically sensing strain through a capacitance change with simultaneous visualization of the strain. A thin mechanochromic bilayer of a BCP SC film with 1D periodic lamellae placed on an IG layer allowed for the direct visualization of strain while sensing the capacitance when embedded in an elastomeric PDMS dielectric medium. Our mechanically flexible and stretchable device consisting of a hydrogel ionic conductor/BCP SC:IG in PDMS/hydrogel ionic conductor structure exhibited a successful sensing performance, with both a capacitance change and an SC modulation observed as a function of strain up to 100%. This result held true even after 1000 strain/release cycles. The affine compression of the 1D lamellae under strain caused the BCP SC to blueshift with strain, offering a useful route for visualizing the strain in full color. The characteristic micron-scale buckled structure of a BCP SC film with periodic lamellae containing glassy PS domains that developed during multiple cycles of deformation and recovery was responsible for the successful SC detection under large strain. This study revealed that the buckled structure arose not only from the unique confined geometry of the BCP SC:IG film in PDMS but also from the ionic liquid, which transported through the screw dislocations in the BCP film and caused the BCP domains to swell. Our BCP SC strain sensor was suitable as a reflectively visible electronic skin, which readily recognized human motion of the finger, elbow, and knee.