Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Review Article
  • Published:

Accuracy of blood pressure monitoring devices: a critical need for improvement that could resolve discrepancy in hypertension guidelines

Abstract

Hypertension is the most significant modifiable risk factor for cardiovascular disease and contributes to the highest global burden of disease. Blood pressure (BP) measurement is among the most important of all medical tests, and it is critical for BP monitoring devices to be accurate. Comprehensive new evidence from meta-analyses clearly shows that many BP monitoring devices (including oscillometric machines and “gold standard” mercury auscultation) do not accurately represent the BP within the arteries at the upper arm (brachial) or central aorta. Particular variability in the accuracy of BP devices compared with intra-arterial BP has been demonstrated in the cuff BP range from prehypertension to grade I hypertension (systolic BP 120–159 to diastolic BP 80–99 mmHg). This is within the BP range that is most common among people worldwide and, thus almost certainly, feeding confusion around optimal hypertension guideline thresholds. At the individual level, inaccurate BP devices have major potential consequences for best practice patient management, where underestimation of true BP is a missed opportunity to lower cardiovascular risk (with therapeutics or lifestyle) and overestimation of true BP could lead to overmedication. Each problem leads to increased cost from preventable cardiovascular events and unnecessary medications. Altogether, there is a critical need to improve the accuracy standards of BP monitoring devices. In the meantime, out-of-office BP (24 h of ambulatory BP and/or home BP monitoring) or automated, unobserved in-office BP monitoring that takes the average of multiple readings using validated devices are the best available options to determine BP control.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Lim SS, Vos T, Flaxman AD, Danaei G, Shibuya K, Adair-Rohani H, et al. A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010. Lancet. 2012;380:2224–60.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Lawes CM, Vander Hoorn S, Law MR, Elliott P, MacMahon S, Rodgers A. Blood pressure and the global burden of disease 2000. Part II: estimates of attributable burden. J Hypertens. 2006;24:423–30.

    Article  CAS  PubMed  Google Scholar 

  3. Olsen MH, Angell SY, Asma S, Boutouyrie P, Burger D, Chirinos JA, et al. A call to action and a lifecourse strategy to address the global burden of raised blood pressure on current and future generations: the Lancet Commission on hypertension. Lancet. 2016;388:2665–712. [Epub Ahead of Print]

    Article  PubMed  Google Scholar 

  4. Sharman JE, Stowasser M. Australian Association for exercise and sports science position statement on exercise and hypertension. J Sci Med Sport. 2009;12:252–7.

    Article  PubMed  Google Scholar 

  5. Appel LJ, Brands MW, Daniels SR, Karanja N, Elmer PJ, Sacks FM. Dietary approaches to prevent and treat hypertension. a scientific statement from the American Heart Association. Hypertension. 2006;47:296–308.

    Article  CAS  PubMed  Google Scholar 

  6. Ettehad D, Emdin CA, Kiran A, Anderson SG, Callender T, Emberson J, et al. Blood pressure lowering for prevention of cardiovascular disease and death: a systematic review and meta-analysis. Lancet. 2016;387:957–67.

    Article  PubMed  Google Scholar 

  7. Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45:142–61.

    Article  CAS  PubMed  Google Scholar 

  8. Whelton PK, He J, Appel LJ, Cutler JA, Havas S, Kotchen TA, et al. Primary prevention of hypertension: clinical and public health advisory from the National High Blood Pressure Education Program. J Am Med Assoc. 2002;288:1882–8.

    Article  Google Scholar 

  9. Poulter NR, Castillo R, Charchar FJ, Schlaich MP, Schutte AE, Tomaszewski M, et al. Are the American Heart Association/American College of Cardiology High Blood Pressure Guidelines fit for global purpose?: Thoughts from the International Society of Hypertension. Hypertension. 2018;72:260–2.

    Article  CAS  PubMed  Google Scholar 

  10. Booth J. A short history of blood pressure measurement. Proc R Soc Med. 1977;70:793–9.

    CAS  PubMed  PubMed Central  Google Scholar 

  11. Sharman JE, Laurent S. Central blood pressure in the management of hypertension: soon reaching the goal? J Hum Hypertens. 2013;27:405–11.

    Article  CAS  PubMed  Google Scholar 

  12. McEniery CM, Cockcroft JR, Roman MJ, Franklin SS, Wilkinson IB. Central blood pressure: current evidence and clinical importance. Eur Heart J. 2014;35:1719–25.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Karamanoglu M, O’Rourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J. 1993;14:160–7.

    Article  CAS  PubMed  Google Scholar 

  14. Rowell LB, Brengelmann GL, Blackmon JR, Bruce RA, Murray JA. Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man. Circulation. 1968;37:954–64.

    Article  CAS  PubMed  Google Scholar 

  15. Protogerou AD, Stergiou GS, Vlachopoulos C, Blacher J, Achimastos A. The effect of antihypertensive drugs on central blood pressure beyond peripheral blood pressure. Part II: evidence for specific class-effects of antihypertensive drugs on pressure amplification. Curr Pharm Des. 2009;15:272–89.

    Article  CAS  PubMed  Google Scholar 

  16. Kelly RP, Gibbs HH, O’Rourke MF, Daley JE, Mang K, Morgan JJ, et al. Nitroglycerin has more favourable effects on left ventricular afterload than apparent from measurement of pressure in a peripheral artery. Eur Heart J. 1990;11:138–44.

    Article  CAS  PubMed  Google Scholar 

  17. Millasseau S, Agnoletti D. Non-invasive estimation of aortic blood pressures: a close look at current devices and methods. Curr Pharm Des. 2015;21:709–18.

    Article  CAS  PubMed  Google Scholar 

  18. Borlaug BA, Olson TP, Abdelmoneim Mohamed S, Melenovsky V, Sorrell VL, Noonan K, et al. A randomized pilot study of aortic waveform guided therapy in chronic heart failure. J Am Heart Assoc. 2014;3:e000745.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Sharman JE, Marwick TH, Gilroy D, Otahal P, Abhayaratna WP, Stowasser M. Randomized trial of guiding hypertension management using central aortic blood pressure compared with best-practice care: principal findings of the BP GUIDE study. Hypertension. 2013;62:1138–45.

    Article  CAS  PubMed  Google Scholar 

  20. Sharman JE, Avolio AP, Baulmann J, Benetos A, Blacher J, Blizzard CL, et al. Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization. Eur Heart J. 2017;38:2805–12.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Williams B, Mancia G, Spiering W, Agabiti Rosei E, Azizi M, Burnier M, et al. ESC/ESH Guidelines for the management of arterial hypertension. European Heart J. 2018;39:3021–104.

  22. Bordley J 3rd, Connor CA, Hamilton WF, Kerr WJ, Wiggers CJ. Recommendations for human blood pressure determinations by sphygmomanometers. Circulation. 1951;4:503–9.

    Article  PubMed  Google Scholar 

  23. Picone DS, Schultz MG, Otahal P, Aakhus S, Al-Jumaily AM, Black JA, et al. Accuracy of cuff-measured blood pressure: systematic reviews and meta-analyses. J Am Coll Cardiol. 2017;70:572–86.

    Article  PubMed  Google Scholar 

  24. Omboni S, Parati G, Groppelli A, Ulian L, Mancia G. Performance of the AM-5600 blood pressure monitor: comparison with ambulatory intra-arterial pressure. J Appl Physiol (Bethesda, MD, 1985). 1997;82:698–703.

    Article  CAS  Google Scholar 

  25. Manios E, Vemmos K, Tsivgoulis G, Barlas G, Koroboki E, Spengos K, et al. Comparison of noninvasive oscillometric and intra-arterial blood pressure measurements in hyperacute stroke. Blood Press Monit. 2007;12:149–56.

    Article  PubMed  Google Scholar 

  26. Danaei G, Finucane MM, Lin JK, Singh GM, Paciorek CJ, Cowan MJ, et al. National, regional, and global trends in systolic blood pressure since 1980: systematic analysis of health examination surveys and epidemiological studies with 786 country-years and 5·4 million participants. Lancet. 2011;377:568–77.

    Article  PubMed  Google Scholar 

  27. Whelton PK, Carey RM, Aronow WS, Casey DE Jr., Collins KJ, Dennison Himmelfarb C, et al. 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Hypertension. 2018;71:e13–e115.

    CAS  PubMed  Google Scholar 

  28. Jones DW, Appel LJ, Sheps SG, Roccella EJ, Lenfant C. Measuring blood pressure accurately: new and persistent challenges. J Am Med Assoc. 2003;289:1027–30.

    Article  Google Scholar 

  29. Head GA, McGrath BP, Mihailidou AS, Nelson MR, Schlaich MP, Stowasser M, et al. Ambulatory blood pressure monitoring in Australia: 2011 consensus position statement. J Hypertens. 2012;30:253–66.

    Article  CAS  PubMed  Google Scholar 

  30. O’Brien E, Parati G, Stergiou G, Asmar R, Beilin L, Bilo G, et al. European Society of hypertension position paper on ambulatory blood pressure monitoring. J Hypertens. 2013;11:11.

    Google Scholar 

  31. Sharman JE, Howes FS, Head GA, McGrath BP, Stowasser M, Schlaich M, et al. Home blood pressure monitoring: Australian expert consensus statement. J Hypertens. 2015;33:1721–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  32. Sharman JE, Blizzard L, Kosmala W, Nelson MR. Pragmatic method using blood pressure diaries to assess blood pressure control. Ann Fam Med. 2016;14:63–69.

    Article  PubMed  PubMed Central  Google Scholar 

  33. Myers MG, Godwin M, Dawes M, Kiss A, Tobe SW, Kaczorowski J. Measurement of blood pressure in the office. recognizing the problem and proposing the solution. Hypertension. 2009;55:195–200.

    Article  PubMed  Google Scholar 

  34. Mancia G, Fagard R, Narkiewicz K, Redon J, Zanchetti A, Bohm M, et al. 2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). Eur Heart J. 2013;34:2159–219.

    Article  PubMed  Google Scholar 

  35. Banegas JR, Ruilope LM, de la Sierra A, Vinyoles E, Gorostidi M, de la Cruz JJ, et al. Relationship between clinic and ambulatory blood-pressure measurements and mortality. N Engl J Med. 2018;378:1509–20.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to James E. Sharman.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sharman, J.E., Marwick, T.H. Accuracy of blood pressure monitoring devices: a critical need for improvement that could resolve discrepancy in hypertension guidelines. J Hum Hypertens 33, 89–93 (2019). https://doi.org/10.1038/s41371-018-0122-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/s41371-018-0122-6

Search

Quick links