Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Experimental Oncology
  • Published:

Intraoperative detection of somatostatin-receptor-positive neuroendocrine tumours using indium-111-labelled DTPA-D-Phe1-octreotide

Abstract

After injection of 111In-labelled DTPA-D-Phe1-octreotide, intraoperative tumour localisation was performed using a scintillation detector in 23 patients with neuroendocrine tumours. Count rates from suspect tumour lesions and adjacent normal tissue were expressed as a ratio before (Rin situ) and after (Rex vivo) excision. 111In activity concentration ratios of tumour tissue to blood (T/B) were determined in a gamma counter. In patients with midgut carcinoids, (all scintigraphy positive), false Rin situ recordings were found in 4/29 macroscopically identified tumours. T/B ratios were all high (27-650). In patients with medullary thyroid carcinomas (eight out of ten scintigraphy positive), misleading Rin situ results were found in 4/37 macroscopically identified tumours. T/B ratios were lower (3-39) than those seen in midgut carcinoids. Two out of four patients with endocrine pancreatic tumours had positive scintigraphy, reliable intraoperative measurements and very high T/B ratios (910-1500). One patient with a gastric carcinoid had correct measurements in situ and ex vivo with high T/B ratios (71-210). In situ measurements added little information to preoperative scintigraphy and surgical findings using the present detection system. Rex vivo measurements were more reliable. The very high T/B ratios seen in midgut carcinoids and some endocrine pancreatic tumours would be favourable for future radiation therapy via somatostatin receptors.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wangberg, B., Forssell-Aronsson, E., Tisell, LE. et al. Intraoperative detection of somatostatin-receptor-positive neuroendocrine tumours using indium-111-labelled DTPA-D-Phe1-octreotide. Br J Cancer 73, 770–775 (1996). https://doi.org/10.1038/bjc.1996.134

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/bjc.1996.134

This article is cited by

Search

Quick links