Abstract
The objective of this study was to assess the accuracy and reliability of mercury and aneroid sphygmomanometers. Measurement of accuracy of calibration and evaluation of physical conditions were carried out in 524 sphygmomanometers, 351 from a hospital setting, and 173 from private medical offices. Mercury sphyg- momanometers were considered inaccurate if the meniscus was not ‘0’ at rest. Aneroid sphygmomanometers were tested against a properly calibrated mercury manometer, and were considered calibrated when the error was ⩽3 mm Hg. Both types of sphygmomanometers were evaluated for conditions of cuff/bladder, bulb, pump and valve. Of the mercury sphygmomanometers tested 21% were found to be inaccurate. Of this group, unreliability was noted due to: excessive bouncing (14%), illegibility of the gauge (7%), blockage of the filter (6%), and lack of mercury in the reservoir (3%). Bladder damage was noted in 10% of the hospital devices and in 6% of private medical practices. Rubber aging occurred in 34% and 25%, leaks/holes in 19% and 18%, and leaks in the pump bulb in 16% and 30% of hospital devices and private practice devices, respectively. Of the aneroid sphygmomanometers tested, 44% in the hospital setting and 61% in private medical practices were found to be inaccurate. Of these, the magnitude of inaccuracy was 4–6 mm Hg in 32%, 7–12 mm Hg in 19% and > 13 mm Hg in 7%. In summary, most of the mercury and aneroid sphygmomanometers showed inaccuracy (21% vs 58%) and unreliability (64% vs 70%).
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 digital issues and online access to articles
$119.00 per year
only $9.92 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Mion, D., Pierin, A. How accurate are sphygmomanometers?. J Hum Hypertens 12, 245–248 (1998). https://doi.org/10.1038/sj.jhh.1000589
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jhh.1000589
Keywords
This article is cited by
-
Diagnostic accuracy of mercurial versus digital blood pressure measurement devices: a systematic review and meta-analysis
Scientific Reports (2022)
-
Use of mercury-based medical equipments and mercury content in effluents of tertiary care hospitals in India
Environmental Monitoring and Assessment (2015)
-
Assessing Blood Pressure Accuracy of an Aneroid Sphygmomanometer in a National Survey Environment
American Journal of Hypertension (2011)
-
Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
Journal of Human Hypertension (2010)
-
The extent of inaccurate aneroid sphygmomanometers in a hospital setting
Wiener Medizinische Wochenschrift (2010)