Access
To read this story in full you will need to login or make a payment (see right).
Letters to Nature
Nature 426, 421-424 (27 November 2003) | doi:10.1038/nature02144; Received 1 July 2003; Accepted 21 October 2003
Open Innovation Challenges
-
Methods of Modeling Adaptation in Populations
The analysis of adaptation with a population is a frequently encountered computational modeling scen...
-
Novel Approaches to Protecting Maize from Insect Damage
The Seeker is looking for novel approaches to protecting maize from insect damage. This Challenge re...
nature jobs
Senior Faculty Positions
- Torrey Pines Institute for Molecular Studies
- Port St. Lucie, FL
Research Fellow
- Beth Israel Deaconess Medical Center
- Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215
Microfluidic sorting in an optical lattice
M. P. MacDonald1, G. C. Spalding1,2 & K. Dholakia1
- School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS, UK
- Department of Physics, Illinois Wesleyan University, Bloomington, Illinois 61702, USA
Correspondence to: M. P. MacDonald1 Email: mpm4@st-and.ac.uk
Abstract
The response of a microscopic dielectric object to an applied light field can profoundly affect its kinetic motion1. A classic example of this is an optical trap, which can hold a particle in a tightly focused light beam2. Optical fields can also be used to arrange, guide or deflect particles in appropriate light-field geometries3, 4. Here we demonstrate an optical sorter for microscopic particles that exploits the interaction of particles—biological or otherwise—with an extended, interlinked, dynamically reconfigurable, three-dimensional optical lattice. The strength of this interaction with the lattice sites depends on the optical polarizability of the particles, giving tunable selection criteria. We demonstrate both sorting by size (of protein microcapsule drug delivery agents) and sorting by refractive index (of other colloidal particle streams). The sorting efficiency of this method approaches 100%, with values of 96% or more observed even for concentrated solutions with throughputs exceeding those reported for fluorescence-activated cell sorting5. This powerful, non-invasive technique is suited to sorting and fractionation within integrated ('lab-on-a-chip') microfluidic systems, and can be applied in colloidal, molecular and biological research.
To read this story in full you will need to login or make a payment (see right).

