Main

Studies in the 1990s showed the value of the sentinel lymph node procedure for staging carcinoma of the breast.1, 2, 3 The technique identifies a sentinel lymph node or nodes in the axilla of a patient with breast carcinoma using a vital dye or radionuclide. If the sentinel lymph node is negative for malignancy, the patient can forego regular axillary lymph node dissection, since the probability that the additional dissected lymph nodes will contain metastatic tumor when the sentinel node is negative is about 5%.4, 5 Examination of the sentinel lymph nodes has been done by frozen section at many institutions. Although of lower quality than permanent sections, frozen sections permit the patient to have evaluation of the sentinel node done during their operation and avoid a second procedure. Intraoperative frozen sections have been controversial because of the labor-intensive techniques necessary to obtain a highly sensitive test, and because of the uncertain significance of frequently detected submicrometastatic carcinoma.

This is a retrospective observational study of the use of frozen section for the examination of sentinel lymph nodes in 874 breast carcinoma patients from 1998 to 2004 at a large private nonprofit teaching medical center. The accuracy of the technique and the problems encountered with its use are discussed.

Materials and methods

Between April 1998 and 2004, sentinel lymph nodes were sent to the laboratory from 908 cases. Sentinel lymph nodes were identified using 450 μCi of filtered technetium sulfur colloid and 3–5 ml of the vital dye isosulfan blue in the operating room.6 The lymph nodes were sent for frozen section diagnosis in 874 cases. Patients ranged in age from 32 to 78 years with a median age of 56 years. Lymph nodes were cut at approximately 2 mm intervals. The pieces were frozen and two or three hematoxylin- and eosin-(H&E) stained 6 μm thick sections were made at each of two levels from each piece. Permanent sections from these blocks were stained with hematoxylin and eosin and examined at three additional levels. An additional level from the paraffin block was stained immunohistochemically with a pankeratin antibody (AE1-AE3, Ventana Corp., Tucson, AZ, USA). The routine use of the anti-keratin was discontinued in 2001, but some pathologists continued to use anti-keratin in certain cases (eg lobular differentiation in the primary tumor, see discussion). Nonsentinel lymph nodes were also cut at 2 mm intervals and submitted entirely, but H&E-stained sections were produced from only one level from each block. Confidence intervals for sensitivity and specificity were calculated using the Wilson score method.7

Results

The number of sentinel lymph nodes ranged from 1 to 12, with a mean of 2.4 lymph nodes per case. Nonsentinel lymph nodes ranged from 0 to 34 in number with a mean of 8.5 lymph nodes. The cases were submitted by 32 different surgeons, but 62% of the submitted cases came from only three of the surgeons. Cases were examined by one of 11 different pathologists.

Table 1 shows the number of positive and negative frozen section results and the corresponding result on permanent section. In all, 16 of the cases were called atypical on frozen section. Overall, 68 of the cases that were negative on frozen section, had positive permanent sections that contained only small numbers of anti-keratin-positive cells (54 cases) or H&E-positive cells (14 cases). These cases were reviewed and all had tumor measuring less than 0.2 mm and most would be staged as ‘pN0(i+) sn’ in the TNM system. Since there is some evidence that these cases do not represent clinically important metastases, Table 2 shows the data with these cases classified as negative.

Table 1 Sentinel lymph node frozen section diagnoses vs permanent section diagnoses
Table 2 Sentinel lymph node frozen section diagnoses vs permanent section diagnoses

Table 3 shows the sensitivity, specificity, overall accuracy (efficiency, concordance rate), false reassurance rate and false alarm rate for the data in Tables 1 and 2. The 95% confidence intervals for sensitivity were 0.54–0.66 for Table 1 data and 0.77–0.87 for Table 2 data. The overall accuracy is the proportion of all cases that were correctly called either positive or negative on frozen section. The false reassurance rate is the proportion of cases called negative on frozen section that was positive on permanent section, that is, cases in which the surgeon was falsely reassured. The false alarm rate was created because of the unusual finding that some of the frozen sections had been called atypical. It is the proportion of frozen sections called atypical that were negative on permanent section, that is, cases in which the surgeon was given a false alarm.

Table 3 Sensitivity and specificity of frozen section diagnosis of sentinel lymph nodes

The 16 cases called ‘atypical’ on frozen section were reviewed by the author. Two cases were thought to have diagnostic carcinoma and had been given an under diagnosis originally, and two cases had probable carcinoma that was difficult to diagnose conclusively. Of the two cases with probable carcinoma on review, one had a few anti-keratin-positive cell clusters in the permanent sections and one had no evidence of tumor in permanent sections by H&E or anti-keratin stains. The other 12 cases had various appearances including some thought to represent histiocytes, high-endothelium venules, and unusual sections of germinal centers.

Discussion

Since the popularization of the sentinel lymph node procedure for breast carcinoma, intraoperative examination of axillary sentinel lymph nodes by frozen section has been controversial. This has been because there is a strong desire to perform the sentinel lymph node biopsy and the subsequent axillary node dissection during a single procedure, but the reported sensitivity of frozen section for the detection of carcinoma in the sentinel node has ranged as low as 54%.8 In a study by Veronesi et al2 in which sentinel lymph nodes were bisected and only one-half of the lymph node was frozen, frozen section diagnosis had a sensitivity of 64% with an overall accuracy of 83%.

Attempts to improve the sensitivity of intraoperative examination have included step sectioning the lymph node, using anti-keratin immunohistochemistry at the time of frozen section, and using cytological preparations from the sentinel lymph node.4, 9, 10 Some of these techniques increase the laboratory workload at the time of frozen section quite dramatically, but sensitivities (in reports with more than 100 patients) have been as high as 93%.4 Recently, Krogerus compared two frozen section techniques.11 Lymph nodes were either bisected and cut twice at each of five levels or they were cut at a thickness of 1–1.5 mm with a razor blade and two sections and touch preparations were made from each piece. The authors claimed that the second method was less labor intensive and found more metastases, but the sensitivity for detection of carcinoma was actually higher using the first technique, since there were no false-negative cases.

In our laboratory a compromise technique was developed in which lymph nodes for frozen section were cut at 2 mm thickness and two sections were cut at each of two or three levels and stained with hematoxylin and eosin. Our data show that frozen sections performed by 11 different pathologists during a 6-year period were highly specific, but only moderately sensitive for the detection of metastatic carcinoma in axillary sentinel lymph nodes. There was no case with a falsely positive frozen section, but in 94 cases, the frozen section was called negative and the subsequent permanent sections contained carcinoma cells (13.3% of negative frozen section cases). Sentinel lymph nodes were positive for metastatic carcinoma of any size in 29% of cases.

The controversy over the use of frozen sections on sentinel lymph nodes has been further complicated by the discovery of increasing numbers of lymph nodes with very small numbers of tumor cells. Prior to the use of the sentinel lymph node technique, routine histologic examination of axillary lymph nodes examined only a small portion of the node. It has been known for many years that routine lymph node examination understages a significant proportion of breast cancer patients.12 It was thought that the sentinel lymph node technique would eliminate this problem by permitting the laboratory to concentrate its resources on the careful examination of a small number of lymph nodes. Unfortunately, many of the positive sentinel lymph nodes detected with step sections and immunohistochemistry have had very small numbers of tumor cells, and the clinical significance of micrometastatic carcinoma (0.2–2.0 mm) and submicrometastatic carcinoma (<0.2 mm) is uncertain. Studies on the clinical significance of these cells have had mixed results,13, 14, 15, 16, 17 and the results of long-term follow-up are not yet available. A recent study by Moore et al18 found evidence that sentinel lymph node tumor cells detected by immunohistochemistry only, might be due to so-called benign transport, and not represent true metastases. Our department confronted the problem of the increasingly frequent finding of individual anti-keratin-positive tumor cells in sentinel lymph nodes in 2001, when some of the pathologists and staff oncologists were concerned that these cells might not represent clinically significant metastases. These patients, staged as N0(i+) sn in the TNM system, were not being treated as having positive axillary lymph nodes in the community, but there was considerable patient anxiety from the diagnosis. Routine use of anti-keratin immunohistochemistry on sentinel lymph nodes was discontinued at that time as recommended by at least some authorities.19 Anti-keratin continued to be used in cases with lobular differentiation in the breast primary tumor, and in cases with other atypical features.

When cases with submicrometastatic tumor were eliminated from the false-negative cases in our data, frozen section sensitivity rose from 0.60 to 0.83 and the overall accuracy rose from 0.89 to 0.96. This is expected, since frozen sections in general have had an accuracy of 0.89–0.99,20 and the key difference between sentinel lymph nodes and a more typical lymph node frozen section is that the pathologist is trying harder to detect a smaller amount of tumor. These values also indicate that intraoperative frozen section diagnosis is a useful technique, especially if patients with only submicrometastatic carcinoma are not considered to have positive lymph nodes. By using frozen sections, 153 patients in our study had axillary lymph node dissection at the same time as their excisional biopsy and 32 patients had to have a second procedure because of a falsely negative frozen section. But if frozen section had not been used, all 185 patients would have had a second procedure.

An interesting phenomenon occurred at the time that routine immunohistochemical staining was stopped. The number of cases called ‘atypical’ on frozen section began to increase. This occurred despite the well-known dictum for frozen section diagnosis, ‘In cancer there are only three possible diagnoses: positive for cancer, negative for cancer, or no diagnosis made’,21 and was probably due to the perceived pressure to find carcinoma cells in the sentinel lymph node. Of the 16 cases called atypical on frozen section, only three had carcinoma on permanent sections. This gives a ‘false alarm’ rate of 0.81, indicating that the atypical diagnosis on sentinel lymph node frozen sections was not helpful.