Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Practice Point
  • Published:

The low-dose corticotropin-stimulation test revisited: the less, the better?

Abstract

In the standard corticotropin-stimulation test, which is used to assess the function of the hypothalamo–pituitary–adrenal axis, synthetic corticotropin is administered at a dose of 250 µg. Previous studies suggested that tests that use lower corticotropin doses had better discrimination than standard-dose tests possibly by avoiding supraphysiological concentrations of corticotropin. Here, we discuss a meta-analysis by Kazluaskaite et al. that compared standard-dose and low-dose corticotropin-stimulation tests and concluded that the low-dose test has a superior sensitivity and specificity. Superiority over the standard-dose test, however, was only found following a series of internal corrections and adjustments conducted by the investigators that might be inappropriate. Unadjusted meta-analyses demonstrated no advantage of the low-dose test over the standard-dose test. As data on the long-term follow-up of patients with borderline results are only available for the standard 250 µg dose test, this test should continue to be advocated, with assay-specific cut-off levels.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

References

  1. Stewart PM et al. (1998) A rational approach for assessing the hypothalamo–pituitary–adrenal axis. Lancet 1: 1208–1210

    Google Scholar 

  2. Dickstein G et al. (1991) Adrenocorticotropin stimulation test: effects of basal cortisol level, time of day, and suggested new sensitive low-dose test. J Clin Endocrinol Metab 72: 773–789

    Article  CAS  Google Scholar 

  3. Mayenknecht J et al. (1998) Comparison of low- and high-dose corticotropin stimulation tests in patients with pituitary disease. J Clin Endocrinol Metab 83: 1558–1562

    Article  CAS  Google Scholar 

  4. Dorin RI et al. (2003) Diagnosis of adrenal insufficiency. Ann Intern Med 139: 194–204

    Article  Google Scholar 

  5. Kazlauskaite R et al. (2008) Corticotropin tests for hypothalamic-pituitary-adrenal axis insufficiency: a meta-analysis. J Clin Endocrinol Metab [10.1210/jc.2008-0710]

  6. Abdu TA et al. (1999) Comparison of the low-dose short synacthen test (1 µg), the conventional-dose short synacthen test (250 µg), and the insulin-tolerance test for assessment of the hypothalamo-pituitary-adrenal axis in patients with pituitary disease. J Clin Endocrinol Metab 84: 838–843

    CAS  Google Scholar 

  7. Agha A et al. (2006) The long-term predictive accuracy of the short synacthen (corticotropin) stimulation test for assessment of the hypothalamic-pituitary-adrenal axis. J Clin Endocrinol Metab 91: 43–47

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Paul M Stewart.

Ethics declarations

Competing interests

The authors declare no competing financial interests.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Stewart, P., Clark, P. The low-dose corticotropin-stimulation test revisited: the less, the better?. Nat Rev Endocrinol 5, 68–69 (2009). https://doi.org/10.1038/ncpendmet1038

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1038/ncpendmet1038

This article is cited by

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing