Abstract
Purpose: To determine the effect of spontaneously elevated intraocular pressure (IOP) on the ocular circulation, and evaluate the result of IOP-lowering procedures in terms of haemodynamics.
Methods: Colour Doppler imaging (CDI) was employed to determine the peak systolic velocity (PSV), end-diastolic velocity (EDV) and time average maximal velocity (TAMV), as well as the Pourcelot ratio (PR) and pulsatility index (PI), of the central retinal artery (CRA), posterior ciliary arteries (PCA) and ophthalmic artery. Various CDI parameters of the eyes with elevated IOP were compared with those of the clinically healthy fellow eyes and the control eyes, separately. Also, data from CDI of glaucoma eyes obtained during the period of elevated IOP and then following IOP-lowering procedures were compared, deliberately avoiding the influence of glaucoma medications.
Results: Eyes (n = 12) with elevated IOP showed significantly decreased flow velocities of the CRA and significantly increased PR and PI of the nasal and temporal PCA, compared with the fellow and control eyes, respectively. Following IOP-lowering procedures, the PR and PI of the nasal PCA decreased significantly.
Conclusion: Spontaneously elevated IOP may induce haemodynamic changes in the CRA and PCA, but no significant change is identified in the ophthalmic artery. Flow velocities tend to decrease while the resistance indices tend to increase with elevated IOP. Such haemodynamic changes may reverse following normalisation of IOP.
Similar content being viewed by others
Article PDF
References
Hayreh SS, Revie IHS, Edwards J . Vasogenic origin of visual field defects and optic nerve change in glaucoma. Br J Ophthalmol 1970;54:461–72.
Socci N, Anderson DR . Blockage of axonal transport in optic nerve induced by elevation of intraocular pressure: effect of arterial hypertension induced by angiotensin I. Arch Ophthalmol 1983;101:94–7.
Armaly MF, Araki M . Optic nerve circulation and ocular pressure. Invest Ophthalmol 1975;14:724–31.
Hamasaki DI, Fujino T . Effects of intraocular pressure on ocular vessels: filling with India ink. Arch Ophthalmol 1967;78:369–79.
Geijer C, Bill A . Effects of raised intraocular pressure on retinal, prelaminar, laminar, and retrolaminar optic nerve blood flow in monkeys. Invest Ophthalmol Vis Sci 1979;18:1030–42.
Sossi N, Anderson DR . Effect of elevated intraocular pressure on blood flow: occurrence in cat optic nerve head studied with iodoantipyrine iodine-125. Arch Ophthalmol 1983;101:98–101.
Blumenthal M, Best M, Galin MA, Gitter KA . Ocular circulation: analysis of the effect of induced ocular hypertension on retinal and choroidal blood flow in man. Am J Ophthalmol 1971;71:819–25.
Riva CE, Grunwald JE, Petrig BL . Autoregulation of human retinal blood flow. Invest Ophthalmol Vis Sci 1986;27:1706–12.
Grunwald JE, Riva CE, Stone RA, et al. Retinal autoregulation in open-angle glaucoma. Ophthalmology 1984;91:1690–4.
Quigley HA, Hohman RM, Sanchez R, Addicks EM . Optic nerve head blood flow in chronic experimental glaucoma. Arch Ophthalmol 1985;103:956–62.
Canning CR, Restori M . Doppler ultrasound studies of the ophthalmic artery. Eye 1988;2:92–5.
Erickson SJ, Hendrix LE, Massaro BM, et al. Colour Doppler flow imaging of the normal and abnormal orbit. Radiology 1989;173:511–6.
Lieb WE, Cohen SM, Merton DA, et al. Colour Doppler imaging of the eye and orbit: technique and normal vascular anatomy. Arch Ophthalmol 1991;109:527–31.
Harris A, Sergott RC, Spaeth GL, et al. Colour Doppler analysis of ocular vessel blood velocity in normal-tension glaucoma. Am J Ophthalmol 1994;118:642–9.
Trible JR, Sergott RC, Spaeth GL, et al. Trabeculectomy is associated with retrobulbar haemodynamic changes: a colour Doppler analysis. Ophthalmology 1994;101:340–51.
Sergott RC, Aburn NS, Trible JR, et al. Colour Doppler imaging: methodology and preliminary results in glaucoma. Surv Ophthalmol 1994;38(Suppl):S65–71.
Rankin SJA, Walman BE, Buckley AR, Drance SM . Colour Doppler imaging and spectral analysis of the optic nerve vasculature in glaucoma. Am J Ophthalmol 1995;119:685–93.
Best M, Galin M, Toyofuku H, Blumenthal M . Differential fluorescein angiography of the ocular fundus. Ann Ophthalmol 1972;4:189–209.
Minckler DS, Spaeth GL . Optic nerve damage in glaucoma. Surv Ophthalmol 1981;26:128–48.
Guthoff RF, Berger RW, Winkler P, et al. Doppler ultrasonography of the ophthalmic and central retinal vessels. Arch Ophthalmol 1991;109:532–6.
Russell RWR . Evidence for autoregulation in human retinal circulation. Lancet 1973;II:1048–50.
Klaver JHJ, Greve EL, Goslinga H, et al. Blood and plasma viscosity measurements in patients with glaucoma. Br J Ophthalmol 1985;69:765–70.
Trope GE, Garcia Salinas R, Glynn M . Blood viscosity in primary open-angle glaucoma. Can J Ophthalmol 1987;22:202–4.
Greenfield DS, Heggerick PA, Hedges TR . Colour Doppler imaging of normal orbital vasculature. Ophthalmology 1995;102:1598–605.
Williamson TH, Lowe GDO, Baxter GM . Influence of age, systemic blood pressure, smoking and blood viscosity on orbital blood velocities. Br J Ophthalmol 1995;79:17–22.
Mendivil A, Guartero V, Mendivil MP . Colour Doppler imaging of the ocular vessels. Graefes Arch Clin Exp Ophthalmol 1995;233:135–9.
Sponsel WE, DePaul KL, Kaufman PL . Correlation of visual function and retinal leukocyte velocity in glaucoma. Am J Ophthalmol 1990;109:49–54.
Rosen ES, Boyd TAS . New method of assessing choroidal ischemia in open-angle glaucoma and ocular hypertension. Am J Ophthalmol 1970;70:912–21.
Hayreh SS . Pathogenesis of visual field defects: role of the ciliary circulation. Br J Ophthalmol 1970;54:289–311.
Baxter GM, Williamson TH . Colour Doppler imaging of the eye: normal ranges, reproducibility, and observer variation. J Ultrasound Med 1995;14:91–6.
Harris A, Williamson TH, Martin B, Shoemaker JA, Sergott RC, Spaeth GL, Katz JLL . Test/retest reproducibility of colour Doppler imaging assessment of blood flow velocity in orbital vessels. J Glaucoma 1995;4:281–6.
Williamson TH, Harris A . Colour Doppler ultrasound imaging of the eye and orbit. Surv Ophthalmol 1996;40:255–67.
Laatikainen L, Mantyla P . Effects of a fall in the intraocular pressure level on the peripapillary fluor-escein angiogram in chronic open-angle glaucoma. Acta Ophthalmol (Copenh) 1974;52:625–33.
Adamson SL, Morrow RJ, Langille BL, et al. Site-dependent effects of increases in placental vascular resistance on the umbilical arterial velocity waveform in fetal sheep. Ultrasound Med Biol 1990;16:19–27.
Thompson RS, Trudinger BJ, Cook CM . Doppler ultrasound waveform indices: A/B ratio, pulsatility index and Pourcelot ratio. Br J Obstet Gynaecol 1988;95:581–8.
Pearce JM, Cambell S, Cohen-Overbeek T, et al. References ranges and sources of variation for indices of pulsed Doppler flow velocity waveforms from the uteroplacental and fetal circulation. Br J Obstet Gynaecol 1988;95:248–56.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Liu, C., Chou, YH., Chou, J. et al. Retrobulbar haemodynamic changes studied by colour Doppler imaging in glaucoma. Eye 11, 818–826 (1997). https://doi.org/10.1038/eye.1997.212
Issue Date:
DOI: https://doi.org/10.1038/eye.1997.212