Abstract
The current use of monkeys for testing intraocular fluids and viscoelastic materials is being questioned because of the decreasing availability and increasing cost of these scarce animals. The rabbit is an inexpensive, readily available, and convenient animal which might provide an alternative model for this purpose. In this study we have outlined the lens changes (clefts or vacuoles) that are observed in the New Zealand white rabbit as a result of toxicity to intraocular test materials. We used two viscoelastic agents, 1% sodium hyaluronate-HealonĀ® and 2% carboxymethylcellulose, and balanced salt solution to evaluate the efficacy and reproducibility of lens changes in this test study. The lens changes in each case were reproducible and could easily be graded. When used in concert with other tests, this new test can help in the preliminary evaulation of an ophthalmic material before its final clinical use in humans.
Similar content being viewed by others
Article PDF
References
Friedenwald JS, Hughes WF, Herrmann H : Acidbase tolerance of the cornea. Arch Ophthalmol 1944, 31: 279ā83.
McDonald TO and Shadduck JA : Eye irrigation: Advances in Modern Toxicology, Vol. 4, Dermatotoxicology and Pharmacology, 1977, pp 162ā166.
McDonald TO, Britton B, Kasten K, et al:.: Reproducibility of ocular scores in experimental animals. Invest Ophthamol 1975, 14(S): 108.
Edelhauser HF, Van Horn DL, Hynduik RA, et al:.: Intraocular irrigating solutions: their effect on the corneal endothelium. Arch Ophthalmol 1975, 93: 648.
Edelhauser HF, Van Horn DL, Schultz RO, et al.:: Comparative toxicity of intraocular irrigating solutions on the corneal endothelium. Am J Ophthalmol 1976, 81: 473.
McCarey BE, Edelhauser HF, Van Horn D : Functional and structural changes in the corneal endothelium during in-vitro perfusion. Invest Ophthalmol 1973, 12: 410ā17.
Haimann MH, Abrams GW, Edelhauser HF, et al:.: The effect of intraocular irrigating solutions on lens clarity in normal and diabetic rabbits. Am J Ophthalmol 1982, 94: 594ā605.
Fechner PU : Preparation of 2% hydroxypropyl-methylcellulose for viscous surgery. Am Intraocular Implant Soc J 1985, 11: 606ā7.
Edelhauser HF, Hanneken AM, Pederson HJ, Van Horn DL : Osmotic tolerance of rabbit and human corneal endothelium. Arch Ophthalmol 1981, 99: 1281ā7.
Gonnering R, Edelhauser HF, Van Horn DL, Durant W : The pH tolerance of rabbit and human corneal endothelium. Invest Ophthalmol Visual Sci 1979, 18: 373ā90.
Killey F, Spencer J, Shimuzu C, Clark D : Effects of chondrotin sulfate in rabbit eyes. Invest Ophthalmol Vis Sci 1983, 24(S): 286.
Allarakhia L, Skelnik DL, Stangler RA, Chopp TM, Lindstrom RL : A comparative evaluation of toxicity, inflammation and intraocular pressure response of viscoelastic agents: Amvisc, Healon, methylcellulose, and Viscoat in the rabbit model. Presented at the annual meeting of the American Society of Cataract & Refractive Surgery, April 1987, Orlando, Florida.
Author information
Authors and Affiliations
Additional information
Supported in part by an unrestricted grant from Research to Prevent Blindness, Inc.
Rights and permissions
About this article
Cite this article
Allarakhia, L., Puumula, M. & Lindstrom, R. A test for crystalline lens biocompatibility. Eye 5, 113ā119 (1991). https://doi.org/10.1038/eye.1991.21
Issue Date: