THERE have been a number of investigations as to the effect of carrier gas flow-rate on separation and column efficiency in gas-liquid chromatographic systems1–4. Many of the results present contradictory pictures of the effect exerted by this parameter. Keulemans1 states, “for a certain set of operational conditions there is an optimum linear gas velocity, but the optimum is very flat and the gas rate is consequently not a highly critical parameter”. James and Martin2 have shown that column efficiency is sensitive to flow-rate and that a decrease in flow-rate increases column efficiency. Their results show a 27 per cent increase in column efficiency when the flow-rate was decreased from 24 to 10 ml./min. Bethea and Wheelock3 reported that column efficiency, as measured by the H.E.T.P., is approximately tripled by raising the flow-rate from 5 to 27.5 ml./min. They found that increasing the flow-rate beyond the latter point gave only meagre increases in efficiency.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 51 print issues and online access
$199.00 per year
only $3.90 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
References
Keulemans, A. I. M., “Gas Chromatography”, 23 (Reinhold Publishing Corporation, New York, 1957).
James, A. T., and Martin, A. J. P., Biochem. J., 50, 679 (1952).
Bethea, R. M., and Wheelock, T. D., Abstracts of the 2nd Biannual International Gas Chromatography Symposium, 1 (published by the Instrument Society of America, Pittsburgh, Penn., 1959).
Mellor, N., in Desty, D. H. (ed.), “Vapour Phase Chromatography”, 67 (Butterworth Scientific Publications, London, 1957).
Lipsky, S. R., and Landowne, R. A., Ann. N.Y. Acad. Sci., 72 (13), 666 (1959).
Johnson, H. W., and Stross, F. H., Anal. Chem., 30, 1586 (1958).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
BERNHARD, R. Effect of Flow-Rate and Sample-Size on Column Efficiency in Gas-Liquid Chromatography. Nature 185, 311–312 (1960). https://doi.org/10.1038/185311a0
Issue Date:
DOI: https://doi.org/10.1038/185311a0
This article is cited by
-
Certain features of preparative gas chromatography in a stream of water vapor
Chemistry and Technology of Fuels and Oils (1979)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.