Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

  • Letter
  • Published:

Effect of Flow-Rate and Sample-Size on Column Efficiency in Gas-Liquid Chromatography

Abstract

THERE have been a number of investigations as to the effect of carrier gas flow-rate on separation and column efficiency in gas-liquid chromatographic systems1–4. Many of the results present contradictory pictures of the effect exerted by this parameter. Keulemans1 states, “for a certain set of operational conditions there is an optimum linear gas velocity, but the optimum is very flat and the gas rate is consequently not a highly critical parameter”. James and Martin2 have shown that column efficiency is sensitive to flow-rate and that a decrease in flow-rate increases column efficiency. Their results show a 27 per cent increase in column efficiency when the flow-rate was decreased from 24 to 10 ml./min. Bethea and Wheelock3 reported that column efficiency, as measured by the H.E.T.P., is approximately tripled by raising the flow-rate from 5 to 27.5 ml./min. They found that increasing the flow-rate beyond the latter point gave only meagre increases in efficiency.

This is a preview of subscription content, access via your institution

Access options

Buy this article

Prices may be subject to local taxes which are calculated during checkout

Similar content being viewed by others

References

  1. Keulemans, A. I. M., “Gas Chromatography”, 23 (Reinhold Publishing Corporation, New York, 1957).

    Google Scholar 

  2. James, A. T., and Martin, A. J. P., Biochem. J., 50, 679 (1952).

    Article  CAS  Google Scholar 

  3. Bethea, R. M., and Wheelock, T. D., Abstracts of the 2nd Biannual International Gas Chromatography Symposium, 1 (published by the Instrument Society of America, Pittsburgh, Penn., 1959).

  4. Mellor, N., in Desty, D. H. (ed.), “Vapour Phase Chromatography”, 67 (Butterworth Scientific Publications, London, 1957).

    Google Scholar 

  5. Lipsky, S. R., and Landowne, R. A., Ann. N.Y. Acad. Sci., 72 (13), 666 (1959).

    Article  ADS  CAS  Google Scholar 

  6. Johnson, H. W., and Stross, F. H., Anal. Chem., 30, 1586 (1958).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

BERNHARD, R. Effect of Flow-Rate and Sample-Size on Column Efficiency in Gas-Liquid Chromatography. Nature 185, 311–312 (1960). https://doi.org/10.1038/185311a0

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/185311a0

This article is cited by

Comments

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Search

Quick links

Nature Briefing

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Get the most important science stories of the day, free in your inbox. Sign up for Nature Briefing