Abstract
Electrocaloric1,2 and electrostrictive3,4 effects concurrently exist in dielectric materials. Combining these two effects could achieve the lightweight, compact localized thermal management that is promised by electrocaloric refrigeration5. Despite a handful of numerical models and schematic presentations6,7, current electrocaloric refrigerators still rely on external accessories to drive the working bodies8,9,10 and hence result in a low device-level cooling power density and coefficient of performance (COP). Here we report an electrocaloric thin-film device that uses the electro-thermomechanical synergy provided by polymeric ferroelectrics. Under one-time a.c. electric stimulation, the device is thermally and mechanically cycled by the working body itself, resulting in an external-driver-free, self-cycling, soft refrigerator. The prototype offers a directly measured cooling power density of 6.5 W g−1 and a peak COP exceeding 58 under a zero temperature span. Being merely a 30-µm-thick polymer film, the device achieved a COP close to 24 under a 4 K temperature span in an open ambient environment (32% thermodynamic efficiency). Compared with passive cooling, the thin-film refrigerator could immediately induce an additional 17.5 K temperature drop against an electronic chip. The soft, polymeric refrigerator can sense, actuate and pump heat to provide automatic localized thermal management.
This is a preview of subscription content, access via your institution
Access options
Access Nature and 54 other Nature Portfolio journals
Get Nature+, our best-value online-access subscription
$29.99 / 30 days
cancel any time
Subscribe to this journal
Receive 51 print issues and online access
$199.00 per year
only $3.90 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Data availability
All data generated or analysed during this study are included in the paper, the Extended Data and the Supplementary Information, and are also available from the corresponding authors upon request. Source data are provided with this paper.
References
Shi, J. et al. Electrocaloric cooling materials and devices for zero-global-warming-potential, high-efficiency refrigeration. Joule 3, 1200–1225 (2019).
Chen, X., Shvartsman, V. V., Lupascu, D. C. & Zhang, Q. M. Electrocaloric cooling—from materials to devices. J. Appl. Phys. 132, 240901 (2022).
Chen, X. et al. Relaxor ferroelectric polymer exhibits ultrahigh electromechanical coupling at low electric field. Science 375, 1418–1422 (2022).
Qian, X., Chen, X., Zhu, L. & Zhang, Q. M. Fluoropolymer ferroelectrics: multifunctional platform for polar-structured energy conversion. Science 380, eadg0902 (2023).
Chen, X., Zhu, W., Rattner, A. S. & Zhang, Q. A self-actuated electrocaloric polymer heat pump design exploiting the synergy of electrocaloric effect and electrostriction. J. Phys.: Energy 5, 024009 (2023).
Bradesko, A. et al. Coupling of the electrocaloric and electromechanical effects for solid-state refrigeration. Appl. Phys. Lett. 109, 143508 (2016).
Park, M. H. et al. Toward a multifunctional monolithic device based on pyroelectricity and the electrocaloric effect of thin antiferroelectric HfxZr1-xO2 films. Nano Energy 12, 131–140 (2015).
Ma, R. J. et al. Highly efficient electrocaloric cooling with electrostatic actuation. Science 357, 1130–1134 (2017).
Gu, H. et al. A chip scale electrocaloric effect based cooling device. Appl. Phys. Lett. 102, 122904 (2013).
Torelló, A. et al. Giant temperature span in electrocaloric regenerator. Science 370, 125–129 (2020).
Constable, G. & Somerville, B. A Century of Innovation: Twenty Engineering Achievements that Transformed our Lives (Joseph Henry, 2003).
Abergel, T. & Delmastro, C. Is cooling the future of heating? International Energy Agency Commentaries https://www.iea.org/commentaries/is-cooling-the-future-of-heating (2020).
Qian, X. Pumping into a cool future: electrocaloric materials for zero-carbon refrigeration. Front. Energy 16, 19–22 (2022).
Abas, N. et al. Natural and synthetic refrigerants, global warming: A review. Renew. Sustain. Energy Rev. 90, 557–569 (2018).
Hawken, P. (ed.) Drawdown: The Most Comprehensive Plan Ever Proposed to Reverse Global Warming (Penguin, 2017).
Yadav, S., Liu, J. & Kim, S. C. A comprehensive study on 21st-century refrigerants - R290 and R1234yf: a review. Int. J. Heat Mass Transf. 182, 121947 (2022).
Wang, D. et al. Experimental research on charge determination and accumulator behavior in trans-critical CO2 mobile air-conditioning system. Energy 183, 106–115 (2019).
Yu, B., Yang, J., Wang, D., Shi, J. & Chen, J. An updated review of recent advances on modified technologies in transcritical CO2 refrigeration cycle. Energy 189, 116147 (2019).
Hou, H., Qian, S. & Takeuchi, I. Materials, physics and systems for multicaloric cooling. Nat.Rev. Mat. 7, 633–652 (2022).
Franco, V. et al. Magnetocaloric effect: From materials research to refrigeration devices. Prog. Mater. Sci. 93, 112–232 (2018).
Neese, B. et al. Large electrocaloric effect in ferroelectric polymers near room temperature. Science 321, 821–823 (2008).
Nair, B. et al. Large electrocaloric effects in oxide multilayer capacitors over a wide temperature range. Nature 575, 468–472 (2019).
Zhang, S. et al. Solid-state cooling by elastocaloric polymer with uniform chain-lengths. Nat. Commun. 13, 9 (2022).
Tušek, J. et al. A regenerative elastocaloric heat pump. Nat. Energy 1, 16134 (2016).
Li, B. et al. Colossal barocaloric effects in plastic crystals. Nature 567, 506–510 (2019).
Kobeco, P. & Kurtchatov, I. Dielectric properties of Rochelle salt crystal. Z. Phys. 66, 192–205 (1930).
Meng, Y. et al. A cascade electrocaloric cooling device for large temperature lift. Nat. Energy 5, 996–1002 (2020).
Li, J. et al. High cooling performance in a double-loop electrocaloric heat pump. Science 382, 801–805 (2023).
Legait, U., Guillou, F., Kedous-Lebouc, A., Hardy, V. & Almanza, M. An experimental comparison of four magnetocaloric regenerators using three different materials. Int. J. Refrig. 37, 147–155 (2014).
Engelbrecht, K., Bahl, C. R. H. & Nielsen, K. K. Experimental results for a magnetic refrigerator using three different types of magnetocaloric material regenerators. Int. J. Refrig. 34, 1132–1140 (2011).
Cui, H. et al. Flexible microfluidic electrocaloric cooling capillary tube with giant specific device cooling power density. Joule 6, 258–268 (2022).
Sette, D. et al. Electrocaloric cooler combining ceramic multi-layer capacitors and fluid. APL Mater. 4, 091101 (2016).
Zheng, S. et al. Colossal electrocaloric effect in an interface-augmented ferroelectric polymer. Science 382, 1020–1026 (2023).
Ribeiro, C. et al. Electroactive poly(vinylidene fluoride)-based structures for advanced applications. Nat. Protoc. 13, 681–704 (2018).
Yang, H., Deng, Y., Cao, B. & Zhu, Y. Study on the local and overall thermal perceptions under nonuniform thermal exposure using a cooling chair. Build. Environ. 176, 106864 (2020).
Qian, X. et al. High-entropy polymer produces a giant electrocaloric effect at low fields. Nature 600, 664–669 (2021).
Bai, P. et al. An active pixel‐matrix electrocaloric device for targeted and differential thermal management. Adv. Mater. 35, 2209181 (2023).
Song, X., Lu, D., Lei, Q., Wang, D. & Chen, J. Energy and exergy analyses of a transcritical CO2 air conditioning system for an electric bus. Appl. Therm. Eng. 190, 116819 (2021).
Ye, Z., Shi, J. & Chen, J. Frosting behavior of louvered-fin and tube heat exchanger after surface treatment: experimental analysis. Appl. Therm. Eng. 194, 117066 (2021).
Feng, B., Tu, J., Zhang, Y.-H., Fan, L.-W. & Yu, Z.-T. An improved steady-state method for measuring the thermal contact resistance and bulk thermal conductivity of thin-walled materials having a sub-millimeter thickness. Appl. Therm. Eng. 171, 114931 (2020).
Zhou, T., Zhao, Y. & Rao, Z. Fundamental and estimation of thermal contact resistance between polymer matrix composites: a review. Int. J. Heat Mass Transf. 189, 122701 (2022).
Cai, Y. et al. Polymeric nanocomposites for electrocaloric refrigeration. Front. Energy 17, 450–462 (2023).
Han, D. et al. Molecular interface regulation enables order-disorder synergy in electrocaloric nanocomposites. Joule 7, 2174–2190 (2023).
Moench, S. et al. Enhancing electrocaloric heat pump performance by over 99% efficient power converters and offset fields. IEEE Access 10, 46571–46588 (2022).
Defay, E. et al. Enhanced electrocaloric efficiency via energy recovery. Nat. Commun. 9, 1827 (2018).
Rao, Z. et al. Curvy, shape-adaptive imagers based on printed optoelectronic pixels with a kirigami design. Nat. Electron. 4, 513–521 (2021).
Bo, Y. et al. Electrostatic actuating double‐unit electrocaloric cooling device with high efficiency. Adv. Energy Mater. 11, 2003771 (2021).
Wang, Y. et al. A high-performance solid-state electrocaloric cooling system. Science 370, 129–133 (2020).
Qian, S. et al. Not-in-kind cooling technologies: a quantitative comparison of refrigerants and system performance. Int. J. Refrig 62, 177–192 (2016).
Acknowledgements
This work was supported by the National Key R&D Program of China (2020YFA0711500, 2020YFA0711503), the National Natural Science Foundation of China (52076127) and the Natural Science Foundation of Shanghai (20ZR1471700, 22JC1401800). X.Q. expresses thanks for the support by the State Key Laboratory of Mechanical System and Vibration (Grants No. MSVZD202211 and No. MSVZD202301), the Oceanic Interdisciplinary Program of Shanghai Jiao Tong University (Project No. SL2020MS009), the Prospective Research Program at Shanghai Jiao Tong University (19X160010008) and the support of the Shanghai Jiao Tong University 2030 Initiative. We thank Luology (Shandong) Advanced Equipment Technology Co., Ltd for support with contact thermal resistance tests. We thank S. Lin for his support with the simulation software. We express thanks for the support by the Student Innovation Center, the Instrumental Analysis Center at Shanghai Jiao Tong University and the National Facility for Translational Medicine (Shanghai).
Author information
Authors and Affiliations
Contributions
X.Q. conceived the concept, designed the device and wrote the manuscript. X.Q., D.H. and Y.Z. conducted the experiments for device performance characterization and reviewed the manuscript. D.H. and S.Z. carried out the materials. C.H. and X.C. measured the strain–electric field curves. D.H., Q.L. and F.D. carried out the simulation. Y.Z. and J.S. supervised the thermal resistance tests. X.Q., D.H. and Y.Z. took the device pictures. D.H., D.W. and Y.Z. designed the energy recovery circuit. H.D., W.C. and G.L. sputtered the electrodes. D.H. and F.D. designed the controlling logical models. X.Q. and J.C. administrated the project. X.Q. supervised the project. All authors analysed and interpreted the data.
Corresponding author
Ethics declarations
Competing interests
X.Q., D.H., Q.L. and Y.Z. are inventors on a patent application related to the described work. The other authors declare no competing interests.
Peer review
Peer review information
Nature thanks Kilian Bartholomé, Brahim Dkhil and the other, anonymous, reviewer(s) for their contribution to the peer review of this work.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data figures and tables
Extended Data Fig. 1 Comparison between the measured temperatures from the infrared camera under various emissivity.
a, Temperature images provided by the IR camera, in which the circle areas are effective for 0.2 and 0.4 emissivity. b, Comparison of temperature data acquired by thermocouple (grey dot line) and IR camera (dots, with light blue line for guidance) at different surrounding temperatures.
Extended Data Fig. 2 Calibration process for heat flux sensor.
a, System designed for measuring cooling power, with a calibration resistance and a sensor signal amplifier. b, Heat loss is caused by foam covering the surface of the resistance in the calibration process. c, Heat loss is caused by air convection on the surface of the DMP film in the practical testing process. d and f, Heat flux signal changing with time until stability as the resistance was heated with foam (d) and air convection (f). e and g, Linear fitting results showing the correlation coefficients with foam (e) and air convection (g).
Extended Data Fig. 3 Measurement of bouncing heights of the DMP and the base terpolymer.
a, View of the camera, in which the 1 mm PP sheet was used as a reference. b, Measured heights of the terpolymer and the DMP under various electric fields.
Extended Data Fig. 4 Bouncing heights have a significant impact on the leakage between the heat source and the heat sink.
a, Heat leakage signals of the device due to the low hGap ~ 0.6 mm. b, As reducing the hGap of the DMP device to ~ 0.6 mm, the heat leakage signals are enhanced.
Extended Data Fig. 5 Long-time operation performance tests.
a, Cooling signal comparison of TD-0.6% at initial and after 1,000,000 cycles. b, Entropy changes of TD-0.6% at initial and after 61,200 cycles. c, Heat flux density curves of the device at initial, after 23,100 cycles, and after 70,800 cycles. d, Comparison of average cooling power densities corresponding to different cycles.
Extended Data Fig. 6 Applied voltage and fluxing charge measurements.
a, Circuit designed to measure fluxing charges through the device. b, Measured current through and voltage on the device.
Extended Data Fig. 7 Simulation for energy recovery between two devices utilizing a circuit with an inductance.
a, Circuit designed to recover the discharging energy. b, Voltage changes of 2 DMP films with time. c, An enlarged view of (b) at around 1 s showing that the recovering process is less than one microsecond.
Extended Data Fig. 8 On/off control by measuring the capacity of the DMP film.
In the on/off control cycle, a micro-computer continuously monitors the dielectric constant of the DMP film. The dielectric constant at a reference temperature of 30 °C serves as the baseline. Simultaneously, the real-time dielectric constant is calculated from the capacitance measurements obtained using an LCR metre. When the real-time dielectric constant exceeds the reference value, the system triggers the high voltage amplifier that then applies AC high voltages to the DMP film.
Supplementary information
Supplementary Information
This file contains Supplementary Figs. 1–10, Tables 1–3 and Notes 1 and 2.
Supplementary Video 1
Motion of the DMP film. When the DMP film was sandwiched between the hot and cold ends, we could not clearly observe the motion of the DMP film. To clearly capture the motion from the top view, we removed the hot and cold ends and allowed the DMP film to bounce freely. The video shows the DMP film powered by a voltage of 2 kV at an operating frequency of 0.5 Hz.
Supplementary Video 2
A 3 × 3 fridge array. Arrays of electrodes with millimetre scales could be designed to meet the cooling needs of surfaces with uneven heat distribution. This video demonstrates a 3 × 3 array circuit in which each unit could be driven on its own by controlling the specified voltage and operating frequency. Gold electrodes with specific shapes were sputtered onto two surfaces of the DMP film. The lower electrodes of all these units were grounded for insulation, and the upper electrodes were connected to different high-voltage outputs through the sputtered gold wires on the upper surface. The effective working area for one unit was the 1 mm × 1 mm square overlapped by the upper and lower surface electrodes. In this demonstration, two units (row 1, column 3 and row 2, column 1) were powered simultaneously at 2 kV and 0.5 Hz, and one unit (row 1, column 1) was powered by an independent voltage at 1.5 kV and 1 Hz.
Supplementary Video 3
Demonstration for automatic temperature regulation. In this video, our device was attached to a temperature soaking plate on PCB, and a transparent quartz glass was placed above, serving as the heat sink. With the capacity of the DMP film detected, the applied voltage was adjusted in real time. Once the perceived temperature exceeded 30 °C, the device started to work, and the frequency accelerated as the temperature increased. The device would stop working as the perceived temperature dropped below 30 °C.
Source data
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Han, D., Zhang, Y., Huang, C. et al. Self-oscillating polymeric refrigerator with high energy efficiency. Nature (2024). https://doi.org/10.1038/s41586-024-07375-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41586-024-07375-3
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.