Introduction

Fluorogenic probes activated by bioorthogonal chemical reactions can enable biomolecule imaging in situations where it is not possible to wash away unbound probe1. Much work has been devoted to expanding the toolbox of bioorthogonal reactions and these efforts can be complemented by the development of fluorogenic probes2. Such probes are typically endowed with a functionality that suppresses fluorescence. Its transformation during the reaction creates a new functionality that no longer quenches the fluorescence of the underlying system, resulting in a fluorescence enhancement. Such probes offer significant advantages for imaging studies in which it is not possible to wash away unreacted probe, such as real-time imaging of dynamic processes in cells or visualization of molecules in live organisms.

One of the most widely used bioorthogonal reactions is the azide−alkyne [3 + 2] cycloaddition to form a triazole3,4. This reaction has enabled the selective visualization of azide- or alkyne-labeled proteins, glycans, nucleic acids and lipids4,5. Several azide-6,7,8,9 fluorogenic probes have been reported, largely based on coumarins6,10, naphthalimides8 and other systems that require UV excitation and emit blue light7,11,12. Such wavelengths are not ideal for biological imaging because of high levels of autofluorescence and poor tissue penetrance13.

An obvious improvement upon these designs would be the development of azido fluorogenic probes with longer excitation and emission wavelengths. Some attempts at achieving this goal have been made8,12,14. The utility of azide pairs in biological settings remains unclear. Thus, fluorogenic azido probes that perform well as cell-imaging reagents remain an important goal. Bertozzi reported the rational design and experimental validation of azide-functionalized fluorogenic probes based on the widely used blue-excitation/green-emission fluorescein scaffold15. In their work, they have prepared a series of azidefluorescein compounds under NaNO2/NaN3 condition and the azidefluorescein was used to biological imaging in Chinese hamster ovary (CHO) cells labled with alkynylsialic acid nor H2S.

It is well known that H2S have been demonstrated to exert protective effects in many pathologies and physiologies16,17,18,19,20,21,22,23,24,25,26. So the discovery of these emerging biological roles of H2S has resulted in rising interest in H2S research. Accordingly, rapid, accurate and reliable methods for H2S detection are in high demand, as they have potential to provide useful information for better understanding its biological functions27. And simple, specific and real-time analytic methods/sensors are highly desirable for H2S in biological systems. In fact, it is a good choice to introduce an azido group into probes to be reduced by H2S due to the simple synthesis, relatively good selectivity, suitable reaction time and non-cell toxicity28,29,30,31,32,33,34.

With these considerations in mind, we also prepared 5-azidefluorescein from 5-aminofluorescein under NaNO2/NaN3 condition according to literature15 (Fig. 1) and tried to use this compound to detect H2S. It is delightful that we obtained the crystal of 5-aminofluorescein and found probe can be used as a high selective and sensitive fluorescent probe for H2S firstly. Furthermore, the probe also was applied in cell imaging.

Figure 1
figure 1

Structure and thermal ellipsoids of probe are drawn at the 50% probability level.

5-aminofluorescein (0.35 g, 1 mmol), a deep-red solid, was dissolved in 10 mL 2:1 AcOH/H2O and cooled to 0°C. To this deep red solution was added NaNO2, a white powder (0.10 g, 1.5 mmol). After stirring for 15 minutes, the solution had turned to a light red color. NaN3 (0.10 g, 1.5 mmol) was then carefully added (caution: gas evolution!), turning the solution to a yellow slurry. The reaction was stirred for 2 hr at 0°C. The slurry was filtered over vacuum and the solid washed with 20 mL 2 mol/L HCl and 100 mL H2O, yielding 5-azidofluoresceinquinone (0.30 g, 80%) as a yellow solid after further drying in vacuo and characterized by NMR, ESI-MS, elemental analysis, X-ray crystal diffractometer (see Figure S1).

Reaction of probe (1 μmol/L) with Na2S (2 μmol/L) as an aqueous sulphide source at room temperature in buffered (10 mmol/L HEPES, pH 7.0) aqueous acetonitrile solution (H2O/CH3CN = 1:3, v/v) yielded a time-dependent fluorescence increase, which was completed within 5 s (Supplementary Fig. S2). ΔF > 50-fold increase in the fluorescence intensity accompanied (Φ = 0.35) with a green emission at 531 nm. However, the analytes without hydrogen sulfide induced no changes in the fluorescence emission properties under the same conditions (Fig. 2a). The competing experiments indicated other analytes did not disturb the determination for sulphide (Fig. 2b). It is noted that the unprecedented speed of this probe's response and high selectivity compared with other probes35,36,37,38 suggests the possibility of quantitative detection without the need for sample pretreatment. The results reason that H2S-mediated reduction of azides to amines would generate highly fluorescent products (Fig. 3)39. H2S-induced product was confirmed its molecular formula by electrospray ionization mass spectrometry (ESI-MS). The peak at m/z 346.42 corresponding to [5-aminofluorescein-H]+, was clearly observed (Supplementary Fig. S3). Further 1HNMR spectroscopic analysis also provided the evidence for the product of 5-aminofluorescein. With addition of 2 equiv. of Na2S (containing crystal water) to probe in DMSO-d6 (Fig. S4), the resonance of the original proton (azidebenzene CH) at 7.28 and 7.49 ppm all shifted to upfield owing to presence of electron- pushing group NH2 (Supplementary Fig. S4) and appeared at 6.65 ~ 6.76 ppm.

Figure 2
figure 2

(a) Fluorescence spectra of probe (1 μmol/L) with various analytes (20 μmol/L) in water:CH3CN (1:3 v/v, HEPES buffer, pH 7.0) solutions (λex = 425 nm, slit: 5 nm/5 nm), inset: a visual fluorescence change photograph for H2S (green) and other analytes (colorless) under illumination with a 365 nm UV lamp; (b) Relative fluorescent intensity (λex = 425 nm, λem = 531 nm) of the system. (black bar: various analytess, red bar: probe + various analytes + H2S).

Figure 3
figure 3

The proposed mechanism for the determination of H2S.

Next, varying concentrations of Na2S (0–2.0 μmol/L) were added to the test reaction solution. The fluorescence intensity increased linearly with the concentration of Na2S up to 2.0 μmol/L, and, thereafter, reached a steady state (Fig. 4). The detection limit, based on the definition by IUPAC (CDL = 3 Sb/m)40, was found to be 0.035 μmol/L from 10 blank solutions (Supplementary Fig. S5). This probe therefore shows a high sensitivity toward sodium sulfide comparable to that of other reported S2−chemosensors35,36,37,38 (Table 1).

Table 1 A compared table about the detection limits and time course for H2S
Figure 4
figure 4

Fluorescence spectra of probe (1 μmol/L) in the presence of various concentrations of H2S (0-2.0 μmol/L) in water:CH3CN (1:3 v/v, HEPES buffer, pH 7.0) solution. (λex = 425 nm, slit: 5 nm/5 nm); each spectrum is recorded 0.5 min after H2S addition.

We also performed absorption spectral experiments in the buffered (10 mmol/L HEPES, pH 7.0) aqueous acetonitrile solution (H2O/CH3CN = 1:3, v/v) containing probe (8 μmol/L) when the H2S was added gradually. Fig. S6 showed absorbance changes of probe in the buffered (10 mmol/L HEPES, pH 7.0) aqueous acetonitrile solution (H2O/CH3CN = 1:3, v/v) after the addition of 4 equiv. of H2S. The probe has no absorbance at UV-Vis area, immediately there generated an absorbance at 510 nm and the absorbance intensity enhanced with increased H2S corresponding solution color change from colorless to yellow. The notable variation was ended after about 4 equiv. of H2S added, relating to the H2S-mediated reduction of 5-azidefluoresceinquinone to 5-aminofluorescein (ring-open).

Most publications suggest that the average endogenous H2S level is in the μmol/L range31,32,41, Since the detection limit of this probe was found to be 0.035 μmol/L, thus it become possible that the probe can detect H2S level in tissue imaging. The ability of probe to detect sulphide within living cells was also evaluated by laser confocal fluorescence imaging using a Leica TCS SP5 laser scanning microscope. Imaging of sulphide substrates in HeLa cells after 30 min incubation using probe (2 μmol/L) showed weak green fluorescence (Fig. 5b). HepG2 cells incubated with 2 μmol/L probe for 30 min at 37°C and with 4 μmol/L exogenous H2S for another 30 min at 37°C, showed green fluorescence (Fig. 5c) (it is noted that 30 min was usually selected in cell imaging experiment). We also carried out time course experiment in the cell. Fig. 6 (left) indicated that a 15 min is enough for cell permeability (Fig. 6h) reaction and the cell can survive even if in a 45 min after H2S was added (Fig. 6i). In addition, according to the Qian's method42, we employed sodium nitroprusside (SNP, a NO donor) to stimulate the production of endogenous H2S in cells43. With the addition of probe into the culture of the SNP (100 μmol/L or 200 μmol/L)-loaded cells for 20 min, a drastic increase of emission intensity (Fig. 6l, 6m), indicating the generation of endogenous H2S within the cells. These results demonstrate that this probe is selective for sulphide and amenable for live-cell imaging.

Figure 5
figure 5

Confocal fluorescence images in HepG2 cells.

(a) absence and presence of 2 μmol/L probe (b); (c) Fluorescence image of HepG2 cells incubated with 2 μmol/L probe for 30 min at 37°C and then incubated with 4 μmol/L H2S for 30 min at 37°C; (d), (e), (f) were their brightfield images of (a), (b), (c).

Figure 6
figure 6

(a) The time dependence of confocal fluorescence images of exogenous sulphide in HepG2 cells. (h) and (i) Fluorescence image of HepG2 cells incubated with 2 μmol/L probe for 30 min at 37°C and then incubated with 4 μmol/L H2S for 15 min and 45 min at 37°C, respectively; (j), (k) were their brightfield images of (h), (i); (b) Confocal fluorescence images of endogenous H2S in living HepG2 cells with probe (2 μmol/L) upon excitation at 425 nm. Cells were prestimulated with SNP (100 μM) for 30 min, then incubated with probe (2 μmol/L) for 20 min (l, n). Cells were prestimulated with SNP (200 μmol/L) for 30 min and then incubated with probe (2 μmol/L) for 20 min (m, o).

The development of innovative fluorescent imaging probes has revolutionized cell biology, allowing localization and dynamic monitoring of cellular metabolite and inorganic ion pools43,44,45. Recently, fluorescence and/or colorimetric chemosensors for H2S/aqueous sulphide based on some reaction mechanisms between probes and H2S have been reported. These include the cleavage of alcoxyl(R-O) bond45,46,47, the cleavage of S-O bond47,48,49, copper displacement approach49,50,51, nucleophilic addition approach5,38,52,53. A significant bottleneck in the above emerging field of H2S/aqueous sulphide signalling is the absence of technology for effective in vivo detection and imaging. And this problem is exacerbated by fact that similar substances such as sulphide which contain SH group may mislead the detection of intracellular thiol concentration. In this study, we have successfully developed an azide-to-amine reduction chemical strategy for selective sulphide detection, which can be used to monitor sulphide generation in live cells in the presence of large excess of thiols. We show that the same chemistry can be readily adapted to different fluorescent templates for sulphide detection and imaging. The same chemistry will lead to new probes with faster response, which may help to monitor fluctuations of H2S in situ. Further optimization and utilization of this strategy and this class of probes should dramatically accelerate future studies of H2S in biology.

Methods

4-(2-Hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) and sodium nitroprusside were purchased from Sigma–Aldrich (St. Louis, MO). Sodium hydroxide solution (0.1 mol/L) was added to aqueous HEPES (10 mmol/L) to adjust the pH to 7.0. Anionic salts were purchased from Shanghai Experiment Reagent Co., Ltd (Shanghai, China). All other chemicals used were of analytical grade. Deionized water was used to prepare all aqueous solutions. The solutions of anions were prepared from their sodium salts.

Instruments

A pH meter (Mettler Toledo, Switzerland) was used to determine the pH. Fluorescence spectra were measured on Cary Eclipse fluorescence spectrophotometer. A PO-120 quartz cuvette (10 mm) was purchased from Shanhai Huamei Experiment Instrrument Plants, China. ESI-MS was measured with an UPLC-ESI-Q-TOF synapt G2 (Waters) instrument. The ability of probe reacting to hydrogen sulfide in the living cells was also evaluated by laser confocal fluorescence imaging using a Leica TCS SP5 laser scanning microscope.

Imaging of HepG2 cells

The HepG2 cells were grown in 1 × SPP medium (1% proteose peptone, 0.2% glucose, 0.1% yeast extract, 0.003% EDTA ferric sodium salt) at 37°C. The HepG2 were treated with 2 μmol/L of probe (methanol stock solution) in culture media for 30 min at 37°C and washed 3 times with PBS. The HepG2 cells were first incubated with 2 μmol/L of probe for 30 min at 37°C and with 20 μM exogenous H2S for final 30 min at 37°C.