Introduction

Molecular fingerprint analysis of genetic and epigenetic alterations of patients generates profound impact on disease diagnosis among high-risk populations1. P53 is probably the most extensively studied tumour-suppressor gene and patients with P53 mutations are known to have a poor outcome2. The pre-diagnosis of specific P53 mutations in plasma are established for prevention and intervention trials for various types of cancers3. Primary liver cancer, mainly hepatocellular carcinoma (HCC), is a major cause of cancer morbidity and mortality worldwide, especially in the underdeveloped countries of Asia and sub-Saharan Africa4,5. Poor prognosis of this malignancy results in its being the third leading cause of cancer deaths in the world6. In many cases, HCCs are not diagnosed until they start to cause symptoms, at which point they may have already been at advanced stages. Mutations at codon 249 of the P53 gene are commonly found in HCCs from southern Africa and Asia in which both aflatoxin B1 (a potent hepatotoxin and hepatocarcinogen) and hepatitis B virus are the major cancer risk factors7.

Various techniques have been developed for screening mutations, including allele-specific hybridization8, primer extension by nucleotide incorporation9, electrophoresis-based methods, mass spectroscopy10, sequence analysis11 and real-time amplification refractory mutation system quantitative polymerase chain reaction assay12. Unfortunately, most of these techniques require fluorescent labelling for imaging and all of their detections require expensive instrumentations. A genotyping procedure that provides inexpensive and sensitive point mutation discrimination with few experimental and instrumental requirements would be desirable especially in the resource-limited areas.

Dew is a common natural phenomenon. It happens when moisture in warm humid air condenses on a cold substrate. Spiders' webs covered with dew are glistening in the bright sun, which make them easily visible. The dew collected on the silk reflects light, enables the webs appear brighter against the foliage. Condensation figures (CFs) provide a robust, power-free and label-free imaging method. The patterns formed by vapor condensation have long been used to test the cleanliness and uniformity of glass surfaces13,14. With ever-increasing interest in CFs, extensive investigations have been made on the formation of CFs experimentally15,16 and theoretically17. CFs have been used to fabricate different structures such as porous materials18, as well as in designing tunable vapor-condensed nanolenses19. Various groups have used these CFs to identify patches of different types of self-assembled molecular monolayers in a number of different applications20,21. It is a low-cost, nondestructive method for determining surface quality in a short time (minutes) and with reasonable reproducibility22.

Inspired by the dew formation, we utilize breathing induced vapor condensation as a power-free and label-free readout for detection of liver cancer related genetic point mutation at codon 249 of P53. Rolling circle amplification (RCA) is an isothermal enzymatic polymerization technique, which can generate long single-strand DNA (ssDNA) with tens and hundreds of repeats23. The simplicity, sensitivity, robustness and low costs provide RCA a distinct position among isothermal techniques for DNA diagnostics24,25. The RCA products can reach several microns in length and tend to collapses into a sphere, which can form hydrophilic DNA networks26. As shown in Figure 1, DNA ligation and amplification by RCA were integrated with DNA microarrays to enable identification of a single base pair mismatch within a 27-mer single-stranded DNA target simply through breathing and naked eye visualization. Taq DNA ligase is a sequence-specific enzyme which can discriminate a single-base substitution. The ligation between the capture probe and the reporter will occur only if the oligonucleotides are perfectly paired to the complementary target DNA without gaps in-between, which will initiate RCA to generate DNA networks and finally makes the DNA microarray chip more hydrophilic. When light casts onto the chip, the hydrophilic regions covered with water films will generate more direct reflection, whereas other regions will generate more scattering, because the surface-to-volume ratio of water films are much greater than the tiny isolated droplets. As a result, the RCA-amplified products on DNA array chip become visible without fluorescent labelling. The current method takes advantage of the vapor condensation induced by breathing to transduce the RCA-amplified variances in DNA contents into visible contrast. The images could be recorded by a cell phone to be saved on its memory or sent to healthcare providers for remote diagnosis through a wireless network27.

Figure 1
figure 1

Schematic illustration of vapor condensation via breathing for detection of genetic point mutation, which could be visualized by naked eye and imaged by the camera in a cell phone.

Results

Breathing-induced vapor condensation on hydrophilic-hydrophobic patterned surface

To prove the feasibility of vapor condensation on a hydrophilic-hydrophobic patterned surface as a way of readout, several hydrophilic-hydrophobic patterned glass slides were achieved by plasma-induced modification of trichloro(octadecyl) silane treated glass28. As shown in Figure 2a, selective retention of green aqueous droplets on the hydrophilic regions was realized on the treated glass, by automatic loading and patterning of aqueous droplets, which proved successful modification of the hydrophilic-hydrophobic patterned glass slide. The molecular modified pattern of the glass at ambient condition could not be visualized by naked eye (Figure 2b). Interestingly, the desired pattern immediately appeared upon breathing onto the glass (Figure 2c).

Figure 2
figure 2

Photographs of the glass slides with hydrophilic-hydrophobic patterns.

(a) Patterned glass slide automatically loaded with droplets after immersion of the entire slide in green dye solution. The images of the patterned glass slides at room temperature (b) and formed with vapor condensation induced by breathing (c). (d) Optical paths on the hydrophilic and hydrophobic patterned glass slide with vapor condensation.

The breathing induced vapor condensation provides a robust, power-free and label-free detection method. The contrasting phenomenon of hydrophilic and hydrophobic glass illustrates the important role of substrate properties (surface energy) on regulating the behaviour of condensed water. According to Volmer's classical nucleation theory29, the free energy barrier (G) for vapor condensation on a flat surface depends strongly on the intrinsic wettability of the surface which is characterized by water contact angle (θ)30. G increases with θ, which means less free energy barrier requires to be overcome for nucleation of a droplet on the hydrophilic (0° < θ < 90°) region than on the hydrophobic (90° < θ < 180°) region. The rate of growth and coalescence of the droplets is also faster on hydrophilic region than hydrophobic region31, resulting in contrasting patterns. The moisture condensed on hydrophilic regions generates water films (diameter > 100 μm), whereas the moisture condensed on hydrophobic regions turn into many tiny isolated droplets (diameter = 1 ~ 6 μm) (Figure 3).

Figure 3
figure 3

The droplets induced by breathing formed on the hydrophilic (a) and hydrophobic (b) regions.

The scale bars are 100 μm.

The process of vapor condensation including droplet nucleation, growth and coalescence are also affected by surface temperature, humidity and temperature of the surrounding environment and vapor flow rate31,32. The vapor condensation on surface is the condensation of excessive moisture in air. There are two ways to induce vapor condensation. The first one is by decreasing the surface temperature. The saturation humidity of air around the cold surface changes with its temperature. Cooling humid warm air will lead to decrement of its saturation humidity. When the saturation humidity of air is lower than its absolute humidity, excessive moisture will be expelled from the air, forming droplets on a surface. As shown in Figure S1, the moisture first condensed into droplets (Figure S1a), then grew in size and finally coalesced into water films(Figure S1b,c) on the hydrophilic-hydrophobic patterned glass slides in a few minutes. However, it could not form vapor condensation under low humidity (e.g. in dry season or desert) by only decreasing the surface temperature33. The second way is by increasing the humidity of the surrounding air, which was demonstrated by the immediate appearance of the patterns formed by using a humidifier (video S1). Here, we combined these two ways by simply breathing to achieve air with 100% humidity and 37°C, which will increase the humidity of the air surrounding the chip and increase the temperature difference between the chip and its surrounding air. It is the most convenient way to induce vapor condensation without precise control of the humidity and temperature of the surrounding environment. Surfaces with hydrophobic treatments can produce many tiny drops, giving the glass a frosted appearance. In contrast, surfaces with hydrophilic treatments, produces thin films of water (video S2).

The thin film of water on hydrophilic region could lead to direct light reflection resulting in much more distinct visualization than the scattered light from the hydrophobic region (Figure 2d). The image contrast of the patterned glass exhibited different appearances by varying the observation angles in the reflection mode (video S3, Figure S2). If the observing angle and the illuminating angle are symmetrical, the hydrophilic spots, which carry the water film, will be more distinct than other places because the light directly reflected are more intense than that scattered. In contrast, if the observing angle and illuminating angle are not symmetrical, the hydrophilic spot will be even dimmer than other places because all the light casted onto hydrophilic spots are directly reflected and is not collected by the cameras or eyes.

RCA-induced alteration of the surface wettability

To prove the feasibility of RCA-induced alteration of the surface wettability, we performed RCA on a DNA array chip. As shown in Figure 4a, the ssDNA splints were immobilized on a small (3 mm × 5 mm) silicon chip coated with thin amine-modified SiO2 as reported in our previous paper34, The templates bear two target complementary segments to the splints at opposite ends. Upon hybridization to the splint sequence in the presence of T4 DNA ligase, the ends of the template are brought in contact to form a circular oligonucleotide. Phi29 DNA polymerase was used for RCA to produce DNA networks. To verify that only RCA-induced DNA networks can alter the surface wettability, we setup the control group, which is compose of ssDNA with similar length as the RCA group, but cannot be amplified by RCA. As showed in Figure 4b, The DNA array chip is composed of 5 × 9 array (5 rows and 9 columns) with 5 × 6 for RCA and 5 × 3 as control. The diameters of the spots were approximately 50 μm, with 200 μm center-to-center spacing. The whole chip was stained with SYBR Green II. The RCA products were obviously brighter than the control group which verified that the RCA products were successfully amplified on the silica. The spots amplified by RCA automatically loaded with water droplets after immersion of the entire slide in water (video S4, S5). The DNA networks could significantly change the wettability of the chip, resulting in visible droplet arrays after water immersion (Figure S3). We could not observe anything on the DNA array chip by naked eye at room temperature (Figure 4c). But with a simple breath onto the chip, the DNA arrays amplified by RCA appeared thanks to the vapor condensation (Figure 4d, video S6). The image of the DNA arrays could be captured by a cell phone for further analysis (Figure 4e f). Cell phones enable users to have access to cost-effective and potable bio-analytical platform at any time and place. The massive volume of users (~7 billion worldwide) drives the rapid improvements of the hardware, software and high-end imaging embedded in cell phones35, transforming the mobile phone into an extremely powerful platform in bioanalytical sciences36,37,38, Here, we took advantage of the imaging system of cell phone to capture and store the breath images, or the wireless connectivity to transfer the related images to remote healthcare stations, enabling mobile healthcare delivery and personalized medicine. To minimize the operation time, we optimized the RCA reaction time. As shown in Figure S4, 30 min was enough to alter the surface to be hydrophilic. The contrast of the breathing-produced images increased with the RCA reaction time.

Figure 4
figure 4

DNA networks amplified by RCA alternating the wettability of the DNA chip and enabling visualization through breathing.

(a) Schematic drawing of RCA process on the chip. (b) Fluorescent image of DNA chip stained with SYBR Green II. The photographs of the DNA chip processed with RCA in room temperature (c) and with vapor condensation through breathing (d). Images of the DNA chip without (e) and with (f) vapor condensation captured by a cell phone (with enlarged images as insert). The scale bars are 400 μm.

Determination of allele discrimination specificity by breathing-induced vapor condensation

To demonstrate the feasibility of this power-free and label free detection method of genetic point mutation, we integrated the target -induced DNA ligation, RCA and vapor condensation-based readout. We chose synthesized target DNA sequences designed according to the two types of predominance mutations (AGG → AGC, AGG → AGT) with a single-base mismatch at codon 249 of P53 in liver cancer patients. The target induced DNA ligation was verified by 20% polyacrylamide-8 M urea sequencing gel. The target ssDNA hybridized simultaneously to the capture probes and the reporter probes and the ligation was strictly dependent on the correct sequence complementarity of the target sequence. As shown in Figure 1 and Figure S5, nucleotide A was perfectly complementary to T in the target sequence (Figure S5, lane 5), whereas C formed a single CT mismatch (Figure S5, lane 4). The reporter probe specifically ligated to the sequence with 3′-terminal A but not to C, since Taq DNA ligase only catalyzed the formation of a phosphodiester bond between the juxtaposed 5′-phosphate and 3′-hydroxyl groups of two ssDNA when they were perfectly complementary to a hybridized target. The conformational change of the DNA led to differences in their migration rates (lane 1 and lane 4 in Figure S6a), which confirmed the successful circularization of the RCA template. The electrophoresis results of the RCA products are shown in Figure S6b, the RCA products were observed in lane 3 in the present of reporter probes, showing extremely low mobility. While no band appeared in lane 2 without reporter probes, indicating no RCA products were generated in the negative control. The results demonstrated that target induced ligation combined with RCA could be used for point mutation detection.

To discriminate genetic point mutation on a chip by breathing-induced vapor condensation, a silicon chip with SiO2 coating was immobilized with capture probes (AGG, AGC, AGT), each in 2 × 6 repeats (Figure 5a). The array probes differ only by the last nucleotide at their 3′ ends. When targets, reporter probes and Taq DNA ligase were simultaneously introduced to the array chip, surface duplexes formed on the array chip. However, ligation only occurred if the duplexes were perfectly complementary. After denaturation with a stringent wash (0.01 M NaOH), the perfectly matched probes were extended with the reporter sequence, while the mismatched probes returned to its original state. The extended probes could be subsequently amplified with RCA process, which altered the property of the surface from being hydrophobic to hydrophilic, resulting in the change of the light propagation mode. The capturing angle affected the imaging modality (Figure S7) as demonstrated previously. For easy operation, this experiment chose a non-direct-reflection angle where areas with scattering appear brighter than areas with direct reflection. As shown in Figure 5b ~ d and video S7, a distinct signal could be observed for the corresponding capture probe spots and only in the presence of each respective target. The detection concentration was down to 1 nM (Figure S8). This assay which based on traditional rolling circle amplification possesses high selectivity for discriminating genetic point mutation39. In order to further facilitate end users, we will improve the overall approach in the future study. According to literatures, several isothermal amplification methods with higher efficiency and easier operation have been developed, such as hyperbranched rolling circle amplification (HRCA)40 and target sequence recycled rolling circle amplification (TR-RCA)41, which provide good references for improving the current breathing-induced detection based on vapor condensation.

Figure 5
figure 5

Multiplex detection of genetic point mutations.

(a) Schematics of the DNA array with three different capture probes. (b) ~ (d) Images of the RCA-amplified chip with the wild type sequence (AGG) and two point mutations (AGG → AGC and AGG → AGT) which were visualized by vapor condensation via breathing and captured by a cell phone. The scale bars are 400 μm.

Discussion

In summary, a nature-inspired method based on vapor condensation was reported for discriminating liver cancer related genetic point mutation. Proof-of-concept detection of synthesized 27-mer ssDNA target (a single-base mismatch at codon 249 of P53, AGG → AGC and AGG → AGT) was accomplished which validated the usefulness of this platform. The DNA networks induced by the amplified targets altered the wettability of the detection spots. Vapor condensation as a readout could transduce the wettability changes of the chip to visualized signals. It provides a power-free, label-free and naked-eye-reading way to detect genetic point mutation in the absence of any instrument. This method which can be potentially applied for point-of-care molecular diagnosis, is of practical importance in remote and resource-poor settings. The real-time results-images can also be remotely accessed by certified professionals, thereby enabling the monitoring of emerging situations. In the future study, we will apply it on the detection of more complex samples (e.g. real sample from patients) upon further optimization.

Methods

Materials

Octadecyltrichlorosilane(OTS) was purchased from Sigma-Aldrich. The following phosphate buffer was used in the experiment: phosphate buffered saline with tween 20 (PBST) (137 mM NaCl, 2.7 mM KCl, 10 mM, Na2HPO4·12H2O, 2 mM KH2PO4, 0.1% Tween 20). T4 DNA ligase was purchased from TaKaRa. RepliPHI™ Phi29 reagent set was purchased from EpiCentre (Chicago,USA). SYBR Green II was purchased from Biohao (Beijing,China). EXO I and EXO III were purchased from New England Biolabs Inc (Ipswich, United States). The following oligonucleotides showed in table S1 were synthesized from the Sangon Biotech Co., Ltd (Shanghai, China) and purified by High Performance Liquid Chromatography. Silicon wafers (B-doped, 100) were provided by CapitalBio (Beijing, China). All aqueous solutions were prepared with deionized water (18 MΩ·cm).

Fabrication of hydrophilic and hydrophobic patterned glass slides

Briefly, to make the glass slides hydrophobic, the cleaned glass slides were immersed in 1% trichloro(octadecyl) silane (OTS)/n-hexane solution for 10 min. Excess OTS was rinsed off with ethanol before drying at 60°C for another 4 h. To construct the hydrophilic-hydrophobic patterned glass slide, a poly(dimethylsiloxane) (PDMS) stamp with pre-designed patterns was pressed onto the OTS-treated glass and then exposed to oxygen plasma with power of 12 W for 60 s to locally convert the terminal groups of the OTS in exposed regions to hydroxyl groups. The PDMS stamps retained excellent conformation and could thus be reused.

Fabrication of gene chip

Micro-carriers were prepared by thermo oxidizing p ++ type, B-doped, (100)-oriented silicon with resistivity <1 mU cm. The 680 nm SiO2 layer was grown at 1000°C by thermal oxidation in H2 and O2 ambient environment at atmospheric pressure. After thermo oxidation, the silicon wafer with a top layer of thermally grown SiO2 was cut into 3 × 5 mm chips with a dicing machine (DAD-321, DISCO Corp., Japan). Then, the micro-carriers were placed in a solution of 1 M NaOH for 10 min, rinsed in deionized water and dried by N2. The dried micro-carriers were amino silanized by immediately placing them in a solution of 10% (vol/vol) (3-aminopropyl)triethoxysilane in ethanol for 20 min and then rinsing for 5 min in ethanol for three times, then 120°C for 3 h. The splint was re-suspended at a concentration of 5 μM in 50% dimethyl sulfoxide and printed by SmartArrayer™ 48 Microarray Spotter (CapitalBio, China).

Verification of the feasibility of the detection method

The chip immobilized with 5 μM splint-1 ssDNA sequence and control splint ssDNA sequence as predesigned gene array. Prior to use, the chip was washed with PBST and dH2O, respectively. Then, 4.5 μM template-1 was added onto the chip and heated up to 60°C for 15 min in an airtight chamber and cooled down to room temperature. Then, 8 U/μL T4 DNA ligase mixed with T4 DNA ligation buffer (66 mM PH 8.0 Tris-HCl buffer, 6.6 mM MgCl2 10 mM dithiothreitol, 1 mM ATP) was added and incubated at 22°C for 4 h. RCA reaction was carried out at 30°C for 12 h in Phi29 reaction buffer (40 mM Tris-HCl (pH = 7.5), 50 mM KCl, 10 mM MgCl2, 5 mM(NH4)2SO4, 4 mM DTT) with 5 U/μL Phi29 polymerase, 880 μM dNTP. Finally, the chip was completely washed with PBST and dH2O.

Determination of allele discrimination specificity in solution

Hybridization of the target with 5′-phosphorylated ssDNA 47-mer reporter probes and the 19-mer capture probes which differ by only the last nucleotide at their 3′-terminals was carried out in 22 μL buffer containing 20 mM Tris-HCl (pH = 7.6), 25 mM potassium acetate, 10 mM dithiothreitol, 10 mM magnesium acetate, 1 mM nicotinamide adenosine dinucleotides, 10 mM DTT, 0.1% Triton X-100, 3.6 μM linear capture probe, 3.6 μM reporter probe, 1.8 μM target and 0.8 U/μL of Taq DNA ligase at 60°C for 1 h. The results were analyzed by 20% urea denaturing polyacrylamide gel.

Preparation of circular DNA template for RCA

4 μM of template-2 and 4 μM of splint-2 were mixed in 20 μL of ligation buffer(66 mM PH 8.0 Tris-HCl buffer, 6.6 mM MgCl2 10 mM dithiothreitol, 1 mM ATP) and annealed together by heating up to 90°C for 5 min and then cooled to room temperature. 175 U of T4 DNA ligase and 1 mM ATP was added and incubated at 16°C for 12 h. After ligation, T4 DNA ligase was inactivated by heating the reaction mixture at 65°C for 10 min. The samples were treated with 10 U ExoI and 40 U ExoIII enzymes that digested ss- and ds-DNA respectively and separated by 20% urea denaturing polyacrylamide gel.

RCA reaction in solution

After circle ligation, two parallel groups of experiments were conducted. One group marked with +R was with adding 2 μL reporter probes. The control group marked with –R was with adding 2 μL dH2O. Polymerization was carried out at 30°C for 1 h in 16 μL of Phi29 reaction buffer (40 mM Tris-HCl pH = 7.5, 50 mM KCl, 10 mM MgCl2, 5 mM(NH4)2SO4, 4 mM DTT) with 5 U/μL Phi29 polymerase, 880 μM dNTP and 4 μL circlar template. The RCA products were analyzed by 1% agarose gel electrophoresis.

Genetic point mutation discrimination by the on-chip detection

The chip immobilized with 5 μM capture probes (249AGCcaptu/249AGTcaptu/249captu) as predesigned gene array. Prior to use, the chip was washed with PBST and dH2O, respectively. The point mutation discrimination was carried out in a solution containing 5 μM reporter probe mixed with the targets in Taq DNA liagase buffer (20 mM Tris-HCl (pH 7.6), 25 mM potassium acetate, 10 mM dithiothreitol, 10 mM magnesium acetate, 1 mM nicotinamide adenosine dinucleotides, 10 mM DTT, 0.1% Triton X-100) by 0.8 U/μL of Taq DNA ligase at 60°C for 1 h. Then, the chip was incubated in 0.01 M NaOH solution for 5 min to remove the un-ligation probe. The template-2 ssDNA sequence was added onto the chip and heated up to 60°C for 15 min in a humidified chamber and cooled down to room temperature. Then, 8 U/μL T4 DNA ligase mixed with T4 DNA ligation buffer (66 mM PH 8.0 Tris-HCl buffer, 6.6 mM MgCl2 10 mM dithiothreitol, 1 mM ATP) was added and incubated at 22°C for 4 h. RCA reaction was carried out at 30°C for 12 h in Phi29 reaction buffer (40 mM Tris-HCl (pH = 7.5), 50 mM KCl, 10 mM MgCl2, 5 mM(NH4)2SO4, 4 mM DTT) with 5 U/μL Phi29 polymerase, 880 μM dNTP. Finally, the chip was washed with PBST and dH2O.