Background & Summary

Computed tomography (CT) scanning has opened new ways for studying various parts of an organism’s biology. This technique has been used in sharks to elucidate the development1, function25 and morphology of their feeding mechanics68. The majority of these studies have focused on small taxonomic subsets to gain detailed anatomical knowledge. However, phylogenetically broad statistical analyses of shark cranial mechanics are still lacking. The lead author of this work is currently undertaking such studies. This contribution provides a descriptor of a large CT dataset of shark anatomy. We used whole specimens from museum collections (a few specimens only comprise the head due to their conservation) to create a dataset of medical CT scans which covers approximately 75% of all extant shark families9.

The x-ray computed tomography library presented here was created for investigating the ecomorphological diversity of shark feeding systems. The data from the CT scans were used to create a second dataset comprising three-dimensional (3D) models of the lower jaw. These models were used to examine lower jaw disparity in extant sharks species in a separate study by quantifying jaw shape using landmark based geometric morphometrics. The lower jaw was selected because it displays a diversity of jaw morphologies between shark species1015. Lower jaws present biomechanically important features related to jaw closing mechanics and are therefore expected to function as a predictor of ecological specialisation1621.

This tomography and virtual 3D dataset can be applied to or used to supplement further comparative and functional analyses of shark morphology. These may include investigations of (a)symmetry, development, integration and modularity or shape change through evolutionary time22. Furthermore, 3D anatomical models provide an excellent visual resource for outreach and education. For example, 3D models can be integrated into 3D PDF documents as interactive figures or can be physically reproduced using rapid prototyping (also referred to as stereolithography or 3D printing)23.

Methods

Specimens

122 individuals representing 73 extant species of 25 out of 34 families from all 9 orders of extant sharks9 (Selachimorpha, Chondrichthyes) are used in the CT scan dataset (Data Citation 1). The specimens are, at the time of CT scanning, formalin preserved and stored in 70% alcohol except for 4 specimens which were stored frozen (RMNH.PISC.36345, RMNH.PISC.verznr.2, 3 and 7). All CT scanned specimens are curated in the spirit collections of the British Museum of Natural History (BMNH) and Naturalis Biodiversity Center (NBC) (see the accompanying metadata for a complete list of specimens). The NBC collections comprise material from the Rijksmuseum van Natuurlijke Historie (RMNH) and the Zoölogisch Museum Amsterdam (ZMA); those institutional identifiers continue to be used here.

CT scanning

CT scans of the specimens housed in the NBC collections were made at the Leiden University Medical Center, the Netherlands (LUMC) with a Toshiba Aquilion 64 medical scanner (Toshiba Medical Systems, Otawara, Japan) using a for the sharks customized scanning and reconstruction protocol (100 kV tube voltage, 150 mAs tube charge per rotation, 64 active channels, acquisition and reconstructed slice thickness 0.5 mm, reconstructed slice increment 0.5 mm, FC03 reconstruction filter, pitch factor 0.83). Specimens from the BMNH collection were scanned at the CT scanning facility of the Royal Brompton and Harefield NHS Trust (RBH), London, United Kingdom, with a Siemens Somatom Sensation 64 medical scanner using a customized scanning protocol with a variable reconstructed slice increment (100 kV tube voltage, 210 mAs tube charge per rotation, acquisition and reconstructed slice thickness 1.0 mm, B30f reconstruction filter).

3D segmentations

The image series from the CT scans were imported into Mimics, v 15.01, (Materialise Software) for segmentation and 3D modelling. We used manual segmentation with a threshold edit of Hounsfield units (i.e., grey values) that are associated to the calcified cartilage of the lower jaw (Fig. 1). The Hounsfield units produced by the medical CT scanners are calibrated according to standard procedures of the manufacturer. The structures of calcified cartilage are not very dense in the scans (meaning relatively low hounsfield units, ranging from 400 to 1,500), and at the border between calcified cartilage and soft tissue, there will always be a partial volume effect that give a 'smoothed' transition from calcified cartilage to soft tissue. Structures with high density, such as the lower jaws, are depicted bright, while structures with low or intermediate density are depicted as dark using optimized greyscales (Fig. 1a). A mask based on measured threshold values of the Hounsfield units, which aligned very closely with the high relative density of the calcified cartilages of the lower jaw is set to produce an exact overlay on the slice images (Fig. 1b). We used these masks to create 3D models of the left lower jaws (Fig. 1c). Threshold values couldn’t be standardised across different scans due to variable tissue densities across specimens. Most 3D models could be modeled without ambiguity. Where manual thresholds were required, ambiguity was checked against left-right symmetry of the skeleton.

Figure 1: 3D segmentation workflow in RMNH.PISC.24047 (Squatina squatina).
figure 1

(a) Each CT scan is build up of multiple slices (tomograms) showing structures with high attenuation of X-rays bright and structures with low attenuation dark, using a grey scale. Each pixel in the tomogram is associated with a Hounsfield unit. (b) A mask (green) is superimposed on the left lower jaw. This mask is based on predetermined threshold values of the Hounsfield unit of to produce an exact overlay on each tomogram. (c) When in each slice a mask is superimposed on the left lower jaw a 3D model is calculated based on the mask. The black line through the 3D model indicates the location of the tomogram in (a,b), mc l=left lower jaw.

Subsequently, each 3D model of the left lower jaw was exported as a *.PLY file from MIMICS (Data Citation 1).

Thirty-one additional 3D models of the left lower jaw were segmented using CT scans provided by other researchers (Table 1), resulting in a total of 153 3D models of 94 extant shark species.

Table 1 Additional MC L.

Data Records

Data record 1—The data for this manuscript have been deposited in a Figshare repository (Data Citation 1). It comprises a dataset of 121 of volumes that consist of tomography images (‘slices’) in DICOM format reconstructed from medical computed tomography (CT) scans of sharks. The matrices of voxels in the dataset represent the Hounsfield units of the corresponding materials and tissues. The Hounsfield unit is associated with a well-defined physics quantity, being the linear attenuation coefficient of these materials and tissues. The majority of the data are whole body CT scans, while a few are CT scans of the head. From the CT scans we generated 153 3D models of the left lower jaws. The accompanying metadata describes the list of CT scanned specimens, their scan parameters and the derived 3D models included in Data record 1. Table 1 describes the specimen list and scan parameters of the additional 3D models of the left lower jaws that are created from CT scans provided by other researchers.

Technical Validation

CT scanner

Medical CT scanners are subject to a regular program for quality control and maintenance under the responsibility of a qualified medical physicist. However, discrepancies between the reconstructed values in an image and the true attenuation coefficients of the scanned object (i.e., image artifacts) can occur. Three common categories of CT image artefact appearances can be distinguished: streaking, shading, and rings and bands. Streaking artifacts appear as straight lines (bright and/or dark) across the image and are the result of the nature of the filtered backprojection reconstruction process. Shading artifacts can occur near objects of high contrast and usually appear in the soft tissue region near bony structures or near air pockets. This type of artifact is hard to identify since it shows a similar shape as the structure creating the shading. Ring and band artifacts can be visible as rings or bands overlaying the original image structure. The occurrence of artifacts can originate from the system design, x-ray tubes, detector, the specimen or operator24. In our dataset only two CT scans show significant artifacts. BMNH 1978.6.22.1 Cetorhinus maximus show ring artifacts in the dense vertebrae and BMNH 1978.6.22.1 Cetorhinus maximus shows ring and streaking artifacts in the dense vertebrae and posterior region of the head. Despite these artifacts skeletal structures were identifiable and useable for 3D segmentation. All other scans are free of artifacts or show only negligible artifacts.

The X-rays, generated by the CT scanner, are used to measure the transmission of X-ray through the specimens under hundreds of different angles. All these measurements are referred to as the raw data. This data is processed with a filtered backprojection, which generates a series of cross-sectional images25. Internal structures are visualized by their ability to attenuate the X-ray beams based on the linear attenuation coefficient. The parameters of the CT scanner were set to optimally visualize the jaws of the sharks. The jaws are well calcified compared to other skeletal structures in the head, therefore structures such as the neurocranium, basihyal and branchial chamber appear less clear in the scans.

Usage Notes

The CT scan data in DICOM format can be loaded into 3D analysis software such as the free software package SPIERS26 or in license based software packages such as MIMICS (http://biomedical.materialise.com/mimics), AVIZO (http://www.fei.com/software/avizo3d/), or VG StudioMax (http://www.volumegraphics.com/en/products/vgstudio-max/basic-functionality/). 3D models of the structures of interest can be produced and exported in various formats using one of these software packages. The exported models can be used in landmark-based geometric morphometric methods27,28 to quantitatively test hypotheses of morphological diversity. The IDAV Landmark Editor29 is a free software package well suited for placing landmarks on the 3D models and exporting the landmark coordinates. Note that Landmark Editor only accepts *.PLY files without binary encoding. The software package Meshab (http://meshlab.sourceforge.net/) can be used to analyse, view and convert the *.PLY files to a usable format for Landmark Editor.

The landmark coordinates generated in Landmark Editor can be used in statistical software designed for geometric morphometric approaches, such as MorphoJ30, Morphologika31, PAST32 or the geomorph package33 in R34.

Additional Information

How to cite this article: Kamminga, P. et al. X-ray computed tomography library of shark anatomy and lower jaw surface models. Sci. Data 4:170047 doi: 10.1038/sdata.2017.47 (2017).

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.