Abstract
Quantum metrology deals with improving the resolution of instruments that are otherwise limited by shot noise and it is therefore a promising avenue for enabling scientific breakthroughs. The advantage can be even more striking when quantum enhancement is combined with correlation techniques among several devices. Here, we present and realize a correlation interferometry scheme exploiting bipartite quantum correlated states injected in two independent interferometers. The scheme outperforms classical analogues in detecting a faint signal that may be correlated/uncorrelated between the two devices. We also compare its sensitivity with that obtained for a pair of two independent squeezed modes, each addressed to one interferometer, for detecting a correlated stochastic signal in the MHz frequency band. Being the simpler solution, it may eventually find application to fundamental physics tests, e.g., searching for the effects predicted by some Planck scale theories.
Similar content being viewed by others
Introduction
Quantum metrology is a sub-field of quantum physics, which deals with improving measurement sensitivity beyond the classical limits, by exploiting the properties of quantum systems1,2,3,4. It has already been used to enhance the performance of interferometers5,6,7,8,9,10,11,12, improve phase estimation13 and super-resolution14,15,16, and surpass the shot-noise limit in imaging17,18,19 and absorption measurements20,21. A first level of improvement achieved with quantum light is offered by the use of squeezed states, which has found applications in advanced detection of gravitational waves22,23. A second level can be obtained by making use of quantum correlations, as entanglement. For example, in refs. 24,25, an advantage of using quantum-correlated light when comparing signals in a pair of interferometers has been demonstrated.
Correlation techniques exploiting more than one interferometer are currently employed in fundamental physics, representing the best sensing methodology proposed for a range of predicted fundamental backgrounds26,27,28,29,30,31 and, in particular, in the research of Planck scale effects32,33,34,35. These sources of noise can produce correlated phase fluctuations in two separated interferometers increasing the chance of distinguishing them with respect to other noise sources, thus exceeding the sensitivity of the single device of orders of magnitude. However, in all the experiments reported up to now28,29,30,34,35, the two (or more) interferometers are fed with separated and independent sources of coherent (and, in some case, squeezed) light, resulting in uncorrelated quantum fluctuations. A double-interferometer configuration is for instance the basis of the Fermilab “holometer”32,34 , a device consisting of two co-located 40 m Michelson interferometers (MIs). The purpose of the holometer is to search for a particular type of correlated background noise, conjectured in some heuristic Planck scale theories and dubbed holographic noise34. Planck scale is where quantum effects unavoidably enter into the description of gravitational theories. Many quantum gravity theories and phenomenological approaches contemplate quantization of the space time at that scale. Non-commutative geometrical variables are associated with uncertainty in measuring relative positions or rotation33,36. It has been argued that light, meanwhile propagating in the arms of an interferometer, would sum up incremental displacement at each discrete Planck interval step leading to a measurable effect. Long-range (spacelike) quantum-like correlation among these variables and the consequent reduction of the effective numbers of independent degrees of freedom would allow also to account for the holographic principle. It is indeed in the comparison of the noise among different interferometers that one can find the signature of this “exotic” correlation and provide experimental clues to the nature of those degrees of freedom. The range of this correlation is expected to be only bounded by causality, namely the two interferometers should occupy the same space time volume. However, as Planck scale effects could have a different behavior depending on the geometrical configuration of the arms (radial, rotational, and translational symmetry), a table-top or single-room experiment is desirable because of the necessity of frequent and quick reconfiguration of the geometry of the system (change of the symmetry/distance). Lack of sensitivity due to the smaller scale (namely one order of magnitude with respect to Fermilab holometer) must be compensated. Of course, it is always possible to reduce the shot noise of a factor S by increasing the optical power of a factor S2, which is not a favorable scaling. In practice, other sources of technical noise, detrimental for the sensitivity, become more and more important with the increasing the beams energy. These include thermal effects on the optics material (beam splitter, mirrors, etc.), spurious scattering from optics imperfections and residual gas impurities, even from photons on the tails of the Gaussian beam again the side walls; however, only with quantum-enhanced techniques the sensitivity of a large experiment can be reproduced or even improved. If confirmed, holographic noise would provide the first empirical support to theories attempting to unify quantum mechanics and gravitation. At the moment, the holometer is operated with classical light only.
According to refs. 24,25, injecting correlated quantum modes such as twin beam (two-mode squeezed vacuum), instead of independent beams, allows a drastic improvement of the sensitivity with respect to the classical case, but the advantage can be in principle disruptive also with respect to the use of two independent squeezed modes. The last condition is obtained when the efficiency and the control of the system are such that photon-number entanglement of twin beam is efficiently preserved up to the joint detection25.
In the present study, we realize the first proof-of-principle of this scheme, showing experimentally the advantage of quantum correlation with respect to the classical case in detecting faint signals that can be either correlated or uncorrelated in two interferometers and matching the same performance of the double squeezing configuration for the former case. For that purpose, we use non-classical correlated states in quadratures (twin beam -like state), which provide the same performance of the entanglement in the actual efficiency regime, reducing at the same time the complexity of the experiment. Our results, on the one hand, open a new branch in quantum metrology, i.e., distributed quantum correlation among several interferometers with great potentiality (provided a large efficiency); on the other hand, they pave the way for unprecedented sensitivity in devices dedicated to search Planck scale effects.
Results
The experimental setup
A simplified schematic of the experiment is shown in Fig. 1. A similar configuration is also used in large-scale experiments, such as LIGO23 and the Fermilab holometer34; however, the latter was without the injection of quantum states. Each interferometer consisted of two piezo-actuated end mirrors, a balanced beam splitter, and a power-recycling mirror (PRM). The relative phase of the individual interferometer arms was chosen such that each readout port was close to the dark fringe and most of the power in the interferometer was recycled37. The interferometer fringe position was chosen such that the output power was 500 μW. The \(\sqrt{P}\) scaling of the shot-noise power spectral density at 13.5 MHz was verified by increasing the input power, P, in the interferometer (for further details, see “Locking scheme” in Methods section).
Each MI was fed with 1.5 mW of 1064 nm light from a low noise Nd:YAG laser source. The same laser source was used for squeezing generation.
The squeezed-light sources were based on parametric down-conversion in a potassium titanyl phosphate crystal placed in semi-monolithic linear cavities (see “Squeezing generation” in Methods section). The squeezed light was injected in the two MIs via their antisymmetric (readout) ports. The readout signals were separated from the squeezed modes by means of optical isolators. The amount of squeezing before injection into the interferometers was measured on a homodyne detector for both sources to be −6.5 dB relative to the shot-noise level (SNL).
The coupled interferometers performance is severely affected by optical losses, which have been carefully characterized (see “Optical losses estimation” in Methods section).
The two possible configurations
The experiment was performed in two different configurations, as shown in Fig. 1.
Independent squeezed states (ISSs): Two ISSs were injected into the interferometers’ antisymmetric ports. This case represents the benchmark to compare with the twin beam approach. A faint correlated stochastic signal acting in both the MIs can emerge by calculating the cross-correlation of their outputs in the time domain, or the cross-spectrum in the frequency domain, even if in a single interferometer the signal is completely hidden by the shot noise. The quantum noise (shot noise) in an interferometer is given by the contribution of the vacuum fluctuation entering the unused port of the beam splitter. If vacuum is substituted by a squeezed state, with a reduction of the noise in one quadrature (at the expense of increasing noise in the other one), and the phase difference with the main laser set properly, the output intensity fluctuation reflects the one of the squeezed quadrature38. This improves the signal-to-noise ratio of the phase signal measurement. Thus, the use of two independent squeezed sources, providing a reduction of the photon noise in each interferometer output, while leaving them uncorrelated, also leads to a significant enhancement in the cross-correlation measurement24,25.
Twin beam-like (TWB) state: A single squeezed state was split on a balanced beam splitter and the modes were injected into the antisymmetric MI ports. The two split beams show non-classical correlations along one quadrature direction similar to the one present in a proper twin beam or two-mode squeezed state38. In practice, it turns out in a stronger than classical correlation between the fluctuation of the interferometers output intensities. Exploiting this quantum correlation, we demonstrate a noise reduction below the SNL in the subtracted outputs of the two interferometers. The subtraction is sensitive to signals that are not correlated between the interferometers and the obtained noise reduction allows detection of signals of smaller amplitude.
We emphasize that genuine twin beam photon-number entanglement can, in principle, offer far superior performance24,25, but, although robust to decoherence39, requires efficiency and stability control, yet out of reach in realistic systems.
Independent squeezed states
The same stochastic signal (simulating the presence of the holographic noise) was injected by two electro-optical modulators (EOMs) in both interferometers, with an amplitude well below the sensitivity of the single MI, ~1/5 of the SNL. The cross-correlation is conveniently evaluated in time domain by considering the normalized covariance, defined as:
where X1(t) (X2(t)) is the time series of the readout signal of the first (second) interferometer, whereas \({X}_{1}^{{\rm{SNL}}}\) (\({X}_{2}^{{\rm{SNL}}}\)) refers to the SNL classical signal.
Figure 2a shows ρ(τ) of the readout signals as a function of the number of samples. The sampling rate was 500 kS s−1 and the total acquisition time was 1 s. Figure 2a is plotted by calculating ρ for increasing subsets of the total number of samples. One can observe that the background level systematically decreases with increasing number of samples, as expected for statistically independent noise sources, whereas the peak height due to the injected correlated signal approaches a constant value (apart some random fluctuations). The correlated noise peak, which is initially hidden in background noise, is resolved for shorter integration times when squeezing is used (red traces), compared with the classical case of no squeezing (blue traces). This results in a more rapidly increasing SNR in the squeezing case, as shown in Fig. 2b. Here, each data point is derived from the ratio between the normalized covariance peak height for τ = 0 and the floor level, averaging over 19 independent data sets similar to the one originating Fig. 2a. The SNR with squeezing injected is consistently higher, by a factor of 2. This is in accordance with the squeezing level introduced and the level of losses estimated inside the interferometer as discussed in “Optical losses estimation” in Methods section. It is noteworthy that the SNR scales as the square root of the number of samples, i.e., with the square root of the acquisition time. Thus, a factor 2 of SNR enhancement corresponds to a reduction of four times in the measurement time.
In the spectral domain, correlated signals can be extracted by the cross-linear spectral density (CLSD) of the two interferometers, as shown in Fig. 3. This quantity is obtained by dividing the time series in Nspectra bins. For each bin, the cross-power spectral density is calculated as the discrete Fourier transform40 of the cross-correlation. The average of the Nspectra cross-power spectral density values is then evaluated. It is noteworthy that in analogy with the cross-correlation, the average reduces the contribution of the uncorrelated photon noise by a factor \({N}_{\,\text{spectra}\,}^{-1/2}\), whereas the correlated signal is unaffected. To obtain the CLSD, the square root of the power spectral density is calculated: therefore, the overall scaling of the uncorrelated contribution with the number of spectra is \({N}_{\,\text{spectra}\,}^{-1/4}\). For Nspectra sufficiently high, the CLSD approaches the linear spectral density of the correlated signals.
Figure 3a shows the CLSD in a bandwidth of 100 kHz after down-mixing the detected signal at 13.5 MHz. The acquisition time was 20 s (106 samples) and the average was performed over Nspectra = 1000. The CLSDs of the solely uncorrelated photon noise are reported as thick solid lines, red with squeezing injection and blue without. They represent the sensitivity level in the detection of a correlated signal, calibrated in m Hz−1/2 (see “Sensitivity calibration” in Methods section). This should be compared with the respective sensitivity of the single interferometer in the two cases (dashed lines). Although almost a factor of 5.6 of improvement is gained by the cross-spectra statistical averaging, an additional multiplicative factor of 1.35 (corresponding to about 2.6 dB) is obtained from the injection of squeezed states.
Injecting a small stochastic signal, the corresponding CLSDs (faint CLSD traces in Fig. 3a) are almost overlapping the CLSD of the photon noise in the coherent (classical) case, whereas the traces are clearly separated from the CLSD of photon noise when squeezing is applied.
Figure 3b shows the scaling of the CLSD average with the number of spectra. The CLSDs of the photon noise, independent in the two interferometers, scale as \({N}_{\,\text{spectra}\,}^{-1/4}\) as expected. When a correlated stochastic signal is injected (simulating the presence of holographic noise), the CLSD reaches a plateau determined by the amplitude of the signal. The maximum absolute sensitivity, i.e., the residual uncorrelated photon-noise level, achieved with independent squeezed states is measured to be 3 × 10−17 m Hz−1/2 (with 68% confidence interval), corresponding to 1/20 of the SNL. This number also represents a limit to the magnitude of a correlated signal (e.g., holographic noise) detectable in this frequency band. We note that, in principle, it is possible to beat the Fermilab holometer performance with a 1 m-long arm, e.g., considering a higher yet realistic optical power (namely 10 kW), longer averaging time (larger than 1 h), and with the help of squeezing.
Twin beam-like state
With the two modes of an evenly split squeezed beam injected into the MIs antisymmetric ports, the non-classical quadrature correlation is expected to provide a photon noise reduction in the readout signal subtraction. Any phase difference between the two MIs produces a change in the relative photo-currents, which is detected with sub-shot-noise sensitivity.
Figure 4 shows the variance of X1(t) − X2(t + τ) as a function of time delay τ. More specifically, Var(X1(t) − X2(t + τ)) = Var(X1) + Var(X2) − 2Cov(X1(t)X2(t + τ)). For τ = 0, the correlation between the two modes leads to a photon noise reduction of 2.5 dB with respect to the SNL, represented by a dip in the variance (thick red line). When two uncorrelated stochastic signals are injected in the MIs, the dip reduces by ~1 dB, as shown by the red faint line. This must be compared with the change between classical coherent trace levels with and without signal injection (blue thick and faint line, respectively), which is only ~0.3 dB. It is noteworthy that for τ ≠ 0, the covariance of X1(t) and X2(t + τ) is zero. As Var(X1(t) − X2(t + τ)) preserves some sub-shot-noise features (around 1 dB), each of the two modes is a squeezed beam affected by 50% loss induced by the beam splitter: the individual squeezing level is therefore degraded but still present in the global state.
This enhancement is also observed in the power spectral density of the subtracted interferometer outputs, plotted in Fig. 5. This experimentally demonstrates that the presence of faint uncorrelated signal can be more easily detected by twin beam-like correlations. Conversely, a correlated signal is completely suppressed by the subtraction. Therefore, measuring the readout signals subtraction for varying distances between the MIs, or the temporal delay, can provide an alternative way to study the coherence properties of the noise sources under investigation.
Figure 6 shows the power spectral density of X1(t) − X2(t) for a single-frequency tone applied to one of the MIs. Also in this case the quantum enhancement is clearly visible. The power spectral density enhancements of the individual interferometers are 1.1 and 0.8 dB respectively, resulting in a collective enhancement of 2 dB in the output subtraction, facilitated by the non-classical correlation among the modes. This enhancement might be applied to identify unwanted uncorrelated background sources, such as scattering or resonances41.
The twin beam approach also allows an enhanced estimation of a correlated signal if one considers the measurement proposed in refs. 24,25, requiring the comparison of two configurations of the setup: one with correlated stochastic signal and the other one with uncorrelated signal. The latter one represents the real background reference, as the holographic noise of fundamental origin cannot be turned off, and also allows discriminating this fundamental signal from other sources of technical noise that are insensitive to the geometrical configuration. In particular, the holographic noise would become independent in the two interferometers if the geometrical configuration is changed (e.g., if one of the arms is rotated of 180°)32,33. We note that, under the approximation in which the signal X in each device can be written as the sum of photon noise and the stochastic white noise (in this case representing the signal), Xi = XWNi + XPNi (i = 1, 2), it turns out that
providing a way to estimate the covariance of the stochastic signal. As the photon fluctuation of each term in the left hand side of Eq. (2) is below the SNL (when quantum correlations are injected), we expect a reduction in the uncertainty on the covariance evaluated in this way. As demonstrated in ref. 25, when the photon-number correlation (entanglement) is injected and preserved at the output ports (requiring very high efficiency and to be very close to the dark fringe), the advantage of this scheme can be disruptive. Considering the best squeezing factor obtained up to now, of 15 dB42, and an optical power of 10 kW as currently used in large-scale experiments, an overall efficiency larger than 99% would be required to have a significant advantage with respect to the independent squeezing setting. The fringe stability strongly depends on the optical power injected and other parameters. For example, for the optical power used in our experiment it is necessary to reach <0.1 μrad. Nevertheless a significant quantum advantage persists also for less demanding conditions. For our experimental parameters, theory predicts almost the same quantum enhancement as for the independent squeezing case25. However, we stress that the twin beam approach is different from using independent squeezing, both conceptually and for potential perspectives. Figure 7 presents the SNR obtained in our experiment when the same level of white noise is injected, first correlated and then uncorrelated, to perform the variance subtraction in Eq. (2). Each point, corresponding to a fixed number of samples (measurement time), is obtained by calculating the ratio of the mean value of the covariance and its SD in a statistically significant number of subsets. The red series corresponds to the injection of a twin beam-like state while the blue one stands for the coherent case. The quantum advantage, as extracted from the fit, is 1.52, which corresponds to about 1.8 dB, quite close to the 2 dB reported, e.g., in Fig. 5, in the presence of uncorrelated noise. The results of Fig. 7 can be, in principle, compared with the ones reported in Fig. 2b related to the measurement of the normalized covariance in the independent squeezing case (the normalization is irrelevant for the SNR). However, we stress that some technical difference occurred in the realization of the two measurements, in particular the starting level of squeezing was of 2.5 for twin beam-like case and 3 dB for independent squeezing due to alignment and also the injected noise was actually higher in the twin beam-like case. It can be shown numerically that these discrepancies account for the different quantum advantage obtained in the two cases. Thus, apart from technical issues that are always subject to fast technological evolution, the twin beam correlation has been demonstrated for the first time to be useful in an interferometric scheme with potential important applications. In fact, this represents a first step that paves the way to achieve the dramatic improvement predicted in refs. 24,25.
Discussion
In this work, we have presented the first realization of a double interferometric system enhanced by quantum correlations, where each interferometer is injected with a mode of a bipartite twin beam-like state. We have demonstrated its applicability to the measurement of possible Planck scale effects30,32,34 expected in the MHz range. The technique proposed here can be, in principle, implemented also at audio frequencies, more interesting for stochastic gravitational wave background, although in this case it is necessary taking into account the quantum back-action, which is not a priori negligible in that frequency range. Although an extended discussion of this point is largely beyond the purpose of this work, we note that a possible approach to back-action noise reduction can be found in refs. 43,44,45.
The twin beam-like state provides a clear quantum enhancement with respect to both the single interferometer and a system of two of them fed with only coherent beams. We have also compared its performance with two independent squeezed states injected in the same system, which represent the state of the art in the field, substantially obtaining a similar behavior in the detection of a correlated signal. In perspective, considering state of the art squeezing generation (15 dB) and an overall efficiency of 90%, the expected sensitivity will be improved by almost one order of magnitude with respect to a pure classical approach, such as the one used at Fermilab holometer. Incidentally, in our experiment we put a limit to certain fundamental effects related to Planck scale physics at frequency of 13.5 MHz. However, as predicted in refs. 24,25, the twin beams approach, representing the first instance of a conceptually new class of quantum-enhanced interferometry, opens the perspectives of an extremely high advantage in the case of large detection efficiencies and fine control of the fringe point, still challenging in present technology.
Methods
Locking scheme
A detailed schematic of the individual interferometer is shown in Fig. 8.
Because of the PRM, a change in any individual arm length affects the interferometer power output and the cavity resonance condition at the same time. Therefore, two degrees of freedom need to be controlled: rather than considering the individual arm lengths L1 and L2, we define the common arm length (CARM) as (L1 + L2)/2 and the differential arm length (DARM) as L1 − L2. The CARM controls the cavity resonance, whereas the DARM controls the interferometer fringe position.
The CARM was locked to the cavity resonance through the Pound-Drever-Hall (PDH) locking technique46. A 20 MHz phase modulation was applied to the input beam by an EOM). The beam reflected from the PRM was separated from the incoming beam with a Faraday isolator and detected by a photo detector which generated an error signal by demodulating the signal at 20 MHz. This error signal was processed by a proportional-integral (PI) controller and the output was applied to both end mirror actuators with no relative phase lag.
The DARM was locked close to the interferometer dark port using a phase modulated sideband at 7.6 MHz. The readout signal was demodulated at 7.6 MHz and processed by a PI. The output of this PI controller was applied to the end mirrors actuators differentially (i.e., the two actuators moved exactly out of phase).
The DARM locking sideband at 7.6 MHz was generated by an EOM, positioned in one arm of the interferometer. This EOM was also used to generate single-frequency tone and stochastic noise modulation from 12.3 to 13.8 MHz (extending well outside the measurement band). The stochastic noise generator had two channels and allowed producing both uncorrelated and highly correlated noise between them. These modulations acted as artificial signals for testing the system performance.
The intra-cavity power was measured using a spurious reflection from the beam splitter. This was used to estimate the gain of the cavity, which in typical working conditions varied between 8 and 10.
Sensitivity calibration
The sensitivities plotted in Fig. 3 are expressed in m Hz−1/2. This was obtained by calibrating the strain δx produced by the phase modulator generating the phase noise:
where λ = 1064 nm, BW is the measurement bandwidth, and Vπ and Vrms are, respectively, the half-wave voltage and the input root-mean-square voltage at the phase modulator.
Squeezing generation
The schematic of the squeezed-light source is shown in Fig. 9. The source was based on parametric down-conversion in a potassium titanyl phosphate crystal placed in a semi-monolithic linear cavity.
The cavity was seeded with 1064 nm light to lock the cavity length, using a PDH lock, and the crystal was pumped with 70 mW of 532 nm light. The pumping gave rise to a phase dependent amplification of the seed beam. Locking this relative phase between seed and pump to the bottom of the generated gain curve, through a sideband generated error signal, the squeezing was produced in the amplitude quadrature.
Quantum noise locking
The outputs from the squeezing sources were injected from the antisymmetric port into each interferometer, according to ISS or TWB configuration in Fig. 1. The control beams of both squeezing sources entered the interferometers with the squeezed light carrying sidebands at 37.22 MHz (36.7 MHz; see Fig. 8). These sidebands were used to lock the squeezing phase to the bright output beam of the interferometer through a piezo-actuated mirror in the squeezed beam path.
Data acquisition
The alternating current (AC) outputs of the photo detectors were demodulated at 13.5 MHz and lowpass filtered at 100 kHz. Both the two direct current output signals and the two demodulated AC output signals (dubbed X1 and X2 in the text) were simultaneously recorded using a data acquisition card. When correlated white noise or twin beam-like light was injected, the phase between the two electrical local oscillators used for demodulation was adjusted to maximize the cross correlations.
Optical losses estimation
We have performed a characterization of the losses of the main coherent beam based on a model of the fringe of a power-recycling interferometer. By fitting the experimental data of the gain G and the power measured at the antisymmetric port PAS as functions of the DARM with the theoretical expression, one can extract both the reflection of the PRM and the mode mismatch:
Reflection of the PRM: Rprm = 0.91(1). This value, obtained from the fit, is consistent with an independent measurement and with the nominal value provided by the producer, supporting the validity of the model;
Mode mismatch and other losses inside the power-recycling cavity (excluding Rprm), and from the beam splitter to the detector included: Ld = 0.26(1). This accounts for cavity mode mismatching, the presence of the EOM inside the arms and output isolators (2 of them are used in a single interferometer).
The other optical losses from end mirror and the beam splitter are negligible.
From the value reported above, we have an overall efficiency of 0.91 × (1 − 0.26) = 0.67, i.e., 33% of losses. On the other hand, the observed reduction of squeezing from 6.5 dB to 2.6 dB corresponds to a loss of about 42%. The residual 9% of difference, can be attributed to the double passing through the output isolators (injection and readout) of the squeezed beam, while the local oscillator passes only once. It is worth observing that the reported value of losses can slightly change from one run to another because of different misalignment and accordingly also the level of quantum noise reduction in the various measurements.
Data availability
All relevant data that have been acquired to generate the figures presented in here and to obtain the parameters reported are available at least from the authors.
References
Giovannetti, V., Lloyd, S. & Maccone, L. Advances in quantum metrology. Nat. Photonics 5, 222–229 (2011).
Giovannetti, V., Lloyd, S. & Maccone, L. Quantum-enhanced measurement: beating the Standard Quantum Limit. Science 306, 1330–1336 (2004).
Olivares, S. High-precision innovative sensing with continuous-variable optical states. Riv. Nuovo Cimento 41, 341 (2018).
Adesso, G., Bromley, T. R. & Cianciaruso, M. Measures and applications of quantum correlations. J. Phys. A Math. Theor. 49, 473001 (2016).
Caves, C. Quantum-mechanical noise in an interferometer. Phys. Rev. D 23, 1693–1708 (1981).
McKenzie, K., Shaddock, D. A., McClelland, D. E., Buchler, B. C. & Lam, P. K. Experimental demonstration of a squeezing-enhanced power-recycled Michelson interferometer for gravitational wave detection. Phys. Rev. Lett. 88, 231102 (2002).
Tóth, G. & Apellaniz, I. Quantum metrology from a quantum information science perspective. J. Phys. A Math. Theor. 47, 424006 (2014).
Demkowicz-Dobrzański, R., Jarzyna, M. & Kołodyński, J. Quantum limits in optical interferometry. Prog. Opt. 60, 345–435 (2015).
Pezzè, L. & Smerzi, A. Quantum theory of phase estimation. Atom Interferometry 188, 691–741 (2014).
Manceau, M., Leuchs, G., Khalili, F. & Chekhova, M. V. Detection loss tolerant supersensitive phase measurement with an SU(1,1) interferometer. Phys. Rev. Lett. 119, 223604 (2017).
Boto, A. N. et al. Quantum interferometric optical lithography: exploiting entanglement to beat the diffraction limit. Phys. Rev. Lett. 85, 2733–2736 (2000).
Huelga, S. F. et al. Improvement of frequency standards with quantum-entanglement. Phys. Rev. Lett. 79, 3865–3868 (1997).
Berni, A. A. et al. Ab initio quantum-enhanced optical phase estimation using real-time feedback control. Nat. Photonics 9, 577–581 (2015).
D’Angelo, M., Chekhova, M. V. & Shih, Y. Two-photon diffraction and quantum lithography. Phys. Rev. Lett. 87, 013602 (2001).
Oppel, S., Büttner, T., Kok, P. & VonZanthier, J. Superresolving multiphoton interferences with independent light sources. Phys. Rev. Lett. 109, 233603 (2012).
Schäfermeier, C., Ježek, M., Madsen, L. S., Gehring, T. & Andersen, U. L. Deterministic phase measurements exhibiting super-sensitivity and super-resolution. Optica 5, 60–64 (2018).
Brida, G., Genovese, M. & Ruo Berchera, I. Experimental realization of sub-shot-noise quantum imaging. Nat. Photonics 4, 227–230 (2010).
Brida, G. et al. Measurement of sub-shot-noise spatial correlations without background subtraction. Phys. Rev. Lett. 102, 213602 (2009).
Genovese, M. Real applications of quantum imaging. J. Opt. 18, 073002 (2016).
Sabines-Chesterking, J. et al. Sub-shot-noise transmission measurement enabled by active feed-forward of heralded single photons. Phys. Rev. Appl. 8, 014016 (2017).
Losero, E., Ruo-Berchera, I., Meda, A., Avella, A. & Genovese, M. Unbiased estimation of an optical loss at the ultimate quantum limit with twin-beams. Sci. Rep. 8, 7431 (2018).
Abadie, J. et al. A gravitational wave observatory operating beyond the quantum shot-noise limit. Nat. Phys. 7, 962–965 (2011).
Aasi, J. et al. Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light. Nat. Photonics 7, 613–619 (2013).
RuoBerchera, I., Degiovanni, I. P., Olivares, S. & Genovese, M. Quantum light in coupled interferometers for quantum gravity tests. Phys. Rev. Lett. 110, 213601 (2013).
Ruo-Berchera, I. et al. One- and two-mode squeezed light in correlated interferometry. Phys. Rev. A 92, 053821 (2015).
Romano, J. D. & Cornish, N. J. Detection methods for stochastic gravitational-wave backgrounds: a unified treatment. Living Rev. Relativ. 20, 1–223 (2017).
Akutsu, T. et al. Search for a stochastic background of 100-MHz gravitational waves with laser interferometers. Phys. Rev. Lett. 101, 101101 (2008).
Abbott, B. P. et al. Upper limits on the stochastic gravitational-wave background from advanced LIGO’s first observing run. Phys. Rev. Lett. 118, 121101 (2017).
Abbott, B. P. et al. Directional limits on persistent gravitational waves from advanced LIGO’s first observing run. Phys. Rev. Lett. 118, 121102 (2017).
Chou, A. S. et al. MHz gravitational wave constraints with decameter Michelson interferometers. Phys. Rev. D 95, 063002 (2017).
Bassi, A., Grossardt, A. & Ulbricht, H. Gravitational decoherence. Class. Quantum Grav 34, 193002 (2017).
Hogan, C. J. Interferometers as probes of Planckian quantum geometry. Phys. Rev. D 85, 064007 (2012).
Hogan, C. J. & Kwon, O. Statistical model of exotic rotational correlations in emergent space-time. Class. Quantum Grav. 34, 135006 (2017).
Chou, A. S. et al. First measurements of high frequency cross-spectra from a pair of large Michelson interferometers. Phys. Rev. Lett. 117, 111102 (2016).
Chou, A. S. et al. Interferometric constraints on quantum geometrical shear noise correlations. Class. Quantum. Grav. 34, 165005 (2017).
Hogan, C. J. & Kwon, O. Models of exotic interferometer cross-correlations in emergent space-time. Class. Quantum Grav. 35, 204001 (2018).
Meystre, P. & Scully, M. O. Quantum Optics, Experimental Gravity, and Measurement Theory (Springer, USA, 1983).
Schnabel, R. Squeezed states of light and their applications in laser interferometers. Phys. Rep. 684, 1–51 (2017).
Benatti, F., Floreanini, R., Olivares, S. & Sindici, E. Noisy effects in interferometric quantum gravity tests. Int. J. Quant. Inf. 15, 1740014 (2017).
Oppenheim, A.V., Schafer, R.W. & Buck, J.R. Discrete-Time Signal Processing (Prentice-Hall, 1999).
Steinlechner, S. et al. Quantum-dense metrology. Nat. Photonics 7, 626–629 (2013).
Vahlbruch, H., Mehmet, M., Danzmann, K. & Schnabel, R. Detection of 15 dB squeezed states of light and their application for the absolute calibration of photoelectric quantum efficiency. Phys. Rev. Lett. 117, 110801 (2016).
Ma, Y. et al. Proposal for gravitational-wave detection beyond the standard quantum limit through EPR entanglement. Nat. Physics 13, 776–780 (2017).
Sudbeck, J., Steinlechner, S., Korobko, M. & Schnabel, R. Demonstration of interferometer enhancement through Einstein–Podolsky–Rosen entanglement. Nat. Photonics 14, 240–244 (2020).
Jep Yap, M. et al. Generation and control of frequency-dependent squeezing via Einstein–Podolsky–Rosen entanglement. Nat. Photonics 14, 223–226 (2020).
Drever, R. W. P. et al. Laser phase and frequency stabilization using an optical resonator. Appl. Phys. B 31, 97–105 (1983).
Acknowledgements
We acknowledge the “COST Action MP1405 QSPACE,” the European Union’s Horizon 2020, and the EMPIR Participating States in the context of the project 17FUN01 BeCOMe, the John Templeton Foundation (Grant number 43467) for financial support. We also acknowledge the Center for Macroscopic Quantum States (bigQ, DNRF412) of the Danish National Research Foundation and the Danish Council for Independent Research (Individual Postdoc and Sapere Aude 4184-00338B).
Author information
Authors and Affiliations
Contributions
I.R.B., P.T., I.P.D., M.G. (responsible of INRIM quantum optics group), T.G., and U.L.A. (responsible of DTU laboratories) planned the experiment. The experimental realization was achieved (supervised by the formers) by S.T.P. (leading role), E.L., C.S.J., and M.Z. Data analysis was mainly performed by S.T.P., E.L. I.R.B., P.T., and M.Z, with some contribution from all authors. The manuscript was prepared with inputs by all the authors. They also had a fruitful systematic discussion on the progress of the work.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Pradyumna, S.T., Losero, E., Ruo-Berchera, I. et al. Twin beam quantum-enhanced correlated interferometry for testing fundamental physics. Commun Phys 3, 104 (2020). https://doi.org/10.1038/s42005-020-0368-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s42005-020-0368-5
This article is cited by
-
Quantum enhanced non-interferometric quantitative phase imaging
Light: Science & Applications (2023)
-
Direct limits for scalar field dark matter from a gravitational-wave detector
Nature (2021)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.