Abstract
Localization and tracking of ingestible microdevices in the gastrointestinal (GI) tract is valuable for the diagnosis and treatment of GI disorders. Such systems require a large field-of-view of tracking, high spatiotemporal resolution, wirelessly operated microdevices and a non-obstructive field generator that is safe to use in practical settings. However, the capabilities of current systems remain limited. Here, we report three dimensional (3D) localization and tracking of wireless ingestible microdevices in the GI tract of large animals in real time and with millimetre-scale resolution. This is achieved by generating 3D magnetic field gradients in the GI field-of-view using high-efficiency planar electromagnetic coils that encode each spatial point with a distinct magnetic field magnitude. The field magnitude is measured and transmitted by the miniaturized, low-power and wireless microdevices to decode their location as they travel through the GI tract. This system could be useful for quantitative assessment of the GI transit-time, precision targeting of therapeutic interventions and minimally invasive procedures.
This is a preview of subscription content, access via your institution
Access options
Access Nature and 54 other Nature Portfolio journals
Get Nature+, our best-value online-access subscription
$29.99 / 30 days
cancel any time
Subscribe to this journal
Receive 12 digital issues and online access to articles
$119.00 per year
only $9.92 per issue
Buy this article
- Purchase on SpringerLink
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Data availability
The data that support the findings of this study are available from the corresponding authors upon reasonable request.
Code availability
Codes used in this study are available from the corresponding authors upon request.
References
Steiger, C. et al. Ingestible electronics for diagnostics and therapy. Nat. Rev. Mater. 4, 83–98 (2019).
Keller, J. et al. Advances in the diagnosis and classification of gastric and intestinal motility disorders. Nat. Rev. Gastroenterol. Hepatol. 15, 291–308 (2018).
Rao, S. S. C. et al. Evaluation of gastrointestinal transit in clinical practice: position paper of the American and European Neurogastroenterology and Motility Societies. Neurogastroenterol. Motil. 23, 8–23 (2011).
Mimee, M. et al. An ingestible bacterial-electronic system to monitor gastrointestinal health. Science 360, 915–918 (2018).
Kuo, B. et al. Comparison of gastric emptying of a nondigestible capsule to a radio-labelled meal in healthy and gastroparetic subjects. Aliment. Pharmacol. Ther. 27, 186–196 (2008).
Wang, A. et al. Wireless capsule endoscopy. Gastrointest. Endosc. 78, 805–815 (2013).
Hejazi, R. A. et al. Video capsule endoscopy: a tool for the assessment of small bowel transit time. Front. Med. 3, 6 (2016).
Maqbool, S. et al. Wireless capsule motility: comparison of the SmartPill GI monitoring system with scintigraphy for measuring whole gut transit. Digestive Dis. Sci. 54, 2167–2174 (2009).
Dagdeviren, C. et al. Flexible piezoelectric devices for gastrointestinal motility sensing. Nat. Biomed. Eng. 1, 807–817 (2017).
Haase, A. M. et al. Gastrointestinal motility during sleep assessed by tracking of telemetric capsules combined with polysomnography—a pilot study. Clin. Exp. Gastroenterol. 8, 327–332 (2015).
Gharibans, A. A. et al. Artifact rejection methodology enables continuous, noninvasive measurement of gastric myoelectric activity in ambulatory subjects. Sci. Rep. 8, 5019 (2018).
Chen, H. et al. Advances in functional X-ray imaging techniques and contrast agents. Phys. Chem. Chem. Phys. 14, 13469–13486 (2012).
Monge, M. et al. Localization of microscale devices in vivo using addressable transmitters operated as magnetic spins. Nat. Biomed. Eng. 1, 736–744 (2017).
Worsøe, J. et al. Gastric transit and small intestinal transit time and motility assessed by a magnet tracking system. BMC Gastroenterol. 11, 145 (2011).
Andrä, W. et al. A novel method for real-time magnetic marker monitoring in the gastrointestinal tract. Phys. Med. Biol. 45, 3081–3093 (2000).
Son, D. et al. A 5-D localization method for a magnetically manipulated untethered robot using a 2-D array of Hall-effect sensors. IEEE/ASME Trans. Mechatron. 21, 708–716 (2016).
Pourhomayoun, M. et al. Accurate localization of in-body medical implants based on spatial sparsity. IEEE Trans. Biomed. Eng. 61, 590–597 (2014).
Weitschies, W. et al. Magnetic marker monitoring: high resolution real-time tracking of oral solid dosage forms in the gastrointestinal tract. Eur. J. Pharm. Biopharm. 74, 93–101 (2010).
Franz, A. M. et al. Electromagnetic tracking in medicine—a review of technology, validation, and applications. IEEE Trans. Med. Imaging 33, 1702–1725 (2014).
Brink, C. E. et al. Magnetic tracking of gastrointestinal motility. Physiol. Meas. 41, 12TR01 (2020).
Baker-Jarvis, J. & Kim, Sung The interaction of radio-frequency fields with dielectric materials at macroscopic to mesoscopic scales. J. Res. Natl Inst. Stand. Technol. 117, 1–60 (2012).
Schiller, C. et al. Intestinal fluid volumes and transit of dosage forms as assessed by magnetic resonance imaging. Aliment. Pharmacol. Ther. 22, 971–979 (2005).
Mudie, D. M. et al. Physiological parameters for oral delivery and in vitro testing. Mol. Pharmaceutics 7, 1388–1405 (2010).
Dove, I. Analysis of radio propagation inside the human body for in-body localization purposes. Thesis, University of Twente (2014).
Sharma, S. et al. Wireless 3D surgical navigation and tracking system with 100μm accuracy using magnetic-field gradient-based localization. IEEE Trans. Med. Imaging 40, 2066–2079 (2021).
Ham, C. L. G. et al. Peripheral nerve stimulation during MRI: effects of high gradient amplitudes and switching rates. J. Magn. Reson. Imaging 7, 933–937 (1997).
Schaefer, D. J. et al. Review of patient safety in time-varying gradient fields. J. Magn. Reson. Imaging 20, 20–29 (2000).
Klein, V. et al. Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models. Magn. Reson. Med. 85, 1047–1061 (2021).
Sharma, S. et al. 20.4 3D surgical alignment with 100µm resolution using magnetic-field gradient-based localization. In Proc. 2020 IEEE International Solid-State Circuits Conference—(ISSCC) 318–320 (IEEE, 2020).
Mostafaei, F. et al. Variations of MRI-assessed peristaltic motions during radiation therapy. PLoS ONE 13, e0205917 (2018).
Swindle, M. M. et al. Swine as models in biomedical research and toxicology testing. Vet. Pathol. 49, 344–356 (2012).
Ruiz, N. S. et al. Fecal incontinence—challenges and solutions. World J. Gastroenterol. 23, 11–24 (2017).
Lo, Y. K. et al. A wireless implant for gastrointestinal motility disorders. Micromachines 9, 17 (2018).
Kong, Y. L. et al. 3D-printed gastric resident electronics. Adv. Mater. Technol. 4, 1800490 (2019).
Ramadi, K.B., Srinivasan, S.S. & Traverso, G. Electroceuticals in the gastrointestinal tract. Trends Pharmacol. Sci. 41, 960–976 (2020).
Traverso, G. et al. Physiologic status monitoring via the gastrointestinal tract. PLoS ONE 10, e0141666 (2015).
Menciassi, A. et al. Clamping tools of a capsule for monitoring the gastrointestinal tract problem analysis and preliminary technological activity. In Proc. 2005 IEEE International Conference on Robotics and Automation 1309–1314 (IEEE, 2005).
Than, T. D. et al. A review of localization systems for robotic endoscopic capsules. IEEE Trans. Biomed. Eng. 59, 2387–2399 (2012).
Su, S. et al. Investigation of the relationship between tracking accuracy and tracking distance of a novel magnetic tracking system. IEEE Sens. J. 17, 4928–4937 (2017).
Bianchi, F. et al. Localization strategies for robotic endoscopic capsules: a review. Expert Rev. Med. Devices 16, 381–403 (2019).
Pham, D. M. et al. A real-time localization system for an endoscopic capsule using magnetic sensors. Sensors 14, 20910–20929 (2014).
Bass, D. M. et al. Gastrointestinal safety of an extended-release, nondeformable, oral dosage form (OROS®)1. Drug-Saf. 25, 1021–1033 (2002).
Huang, J. et al. IM6D: magnetic tracking system with 6-DOF passive markers for dexterous 3D interaction and motion. ACM Trans. Graph. 34, 217 (2015).
Vasisht, D. et al. In-body backscatter communication and localization. In Proc. 2018 Conference of the ACM Special Interest Group on Data Communication 132–146 (ACM, 2018).
Nadeau, P. et al. Prolonged energy harvesting for ingestible devices. Nat. Biomed. Eng. 1, 0022 (2017).
Talkhooncheh, A. H. et al. A fully-integrated biofuel-cell-based energy harvester with 86% peak efficiency and 0.25V minimum input voltage using source-adaptive MPPT. In 2020 IEEE Custom Integrated Circuits Conference (CICC) 1–4 (IEEE, 2020).
Talkhooncheh, A. H. et al. A biofuel-cell-based energy harvester with 86% peak efficiency and 0.25-V minimum input voltage using source-adaptive MPPT. IEEE J. Solid-State Circuits 56, 715–728 (2021).
Turner, R. Gradient coil design: a review of methods. Magn. Reson. Imaging 11, 903–920 (1993).
Hidalgo-Tobon, S. S. Theory of gradient coil design methods for magnetic resonance imaging. Concepts Magn. Reson. 36A, 223–242 (2010).
Sharma, S. et al. Electromagnet gradient coil apparatus for micro-device localization. US patent 11,457,835 B2 (2021).
Sharma, S. et al. In-vivo monitoring of an internal volume of a mammal using magnetic field gradients. US patent 20,210,137,412 (2021).
Sharma, S. et al. Surgical alignment by magnetic field gradient localization. US patent 11,399,848 B2 (2019).
Khadra, I. et al. Statistical investigation of simulated intestinal fluid composition on the equilibrium solubility of biopharmaceutics classification system class II drugs. Eur. J. Pharm. Sci. 25, 65–75 (2015).
Vertzoni, M. et al. Dissolution media simulating the intralumenal composition of the small intestine: physiological issues and practical aspects. J. Pharm. Pharmacol. 56, 453–462 (2004).
Nevo, E. et al. Method and apparatus to estimate location and orientation of objects during magnetic resonance imaging. US patent 6,516,213 B1 (2003).
Acknowledgements
We acknowledge the contribution of Standard Technology Inc. (FL) in the assembly of gradient coils. We are grateful to the members of MICS Lab (Caltech) for insightful comments and discussions. This research was funded in part by the National Science Foundation under grant 1823036 (A.E. and M.G.S.); in part by the Rothenberg Innovation Initiative under grant 101170 (A.E. and M.G.S.); in part by the Heritage Medical Research Institute under grant 150901 (A.E. and M.G.S.); and in part by a grant from the Karl van Tassel (1925) Career Development Professorship, the Department of Mechanical Engineering at MIT (G.T.). K.B.R. was supported by the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) of the National Institutes of Health (NIH) under award no. F32DK122762 and the Division of Engineering at New York University, Abu Dhabi.
Author information
Authors and Affiliations
Contributions
S.S., K.B.R., N.H.P., S.S.S., M.G.S., G.T. and A.E. conceived and designed the research. S.S. designed and assembled the iMAG devices, EM coils for gradient generation and all the electronics. S.S. performed all the in vitro characterization and localization experiments. K.B.R., S.S. and S.S.S. performed the in vivo characterization and localization experiments. N.H.P. and S.S. programmed the nRF chipset on iMAG and the receiver. S.S. performed all the data processing. K.I., J.K. and J.J. helped during the in vivo experiments. F.A. helped with the iMAG PCB design. M.B.S. helped during the in vitro characterization. S.S. wrote the manuscript, with input from all the other authors. M.G.S., G.T. and A.E. supervised the research.
Corresponding authors
Ethics declarations
Competing interests
S.S., M.G.S. and A.E. have joint US patents (20,210,137,412 and 11,457,835 B2) on the localization and magnetic-field generation concepts. M.G.S. and A.E. are founding members of Tychon Technologies. All the other authors declare no competing interests.
Peer review
Peer review information
Nature Electronics thanks the anonymous reviewers for their contribution to the peer review of this work.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data
Extended Data Fig. 1 Coil embodiments for different use-cases.
a, The flat-spiral Z-coil is shown and is made using several loops of copper wire beginning from an inner diameter of 26 cm and extending to an outer diameter of 60 cm. Using different diameters of the copper wire, different embodiments of the Z-coil (and similarly the X and Y coils) can be realized. b, Gradient profiles generated by the Z-coil of Embodiment-1 carrying 15 A of d.c. current. The prototype used in this work is an implementation of Embodiment-1. c, Gradient profiles generated by the Z-coil of Embodiment-2 carrying 350 mA of d.c. current. The gradient in Embodiment-2 is only 5x lower than the gradient in Embodiment-1, while the d.c. current is 43x lower. d, This is achieved by using a much smaller diameter of the copper wire for Embodiment-2 that results in ≈9x increase in the number of turns that can be fitted in the same coil footprint. The 350 mA of current leads to only 0.25 W of heat (corresponding to <0.1 °C increase in the surface temperature of the coils) for a measurement done every minute, which is sufficient for monitoring the GI transit-time and motility. For applications requiring a higher sampling rate (maximum achievable 3.3 Hz by the current system), thermal insulators can be used around the coils to alleviate the heating. The 7.5 mm of mean position resolution for Embodiment-2 is acceptable for localization in the GI tract. The total weight of the coils in Embodiment-2 and the required battery for powering the coils is suitable for portable prototypes such as jackets or backpacks.
Extended Data Fig. 2 Localization error of iMAG as a function of distance from the coils.
a, The spatial error while localizing a single iMAG relative to the gradient coils is plotted for Z = 6 cm plane. The X, Y and Z errors (shown below the coil-setup) are close to the lower error-bound of the system (≈1 mm). b, The spatial errors are plotted for Z = 12 cm plane and the errors in most regions of the FOV are in 1–2 mm range. The transition to the higher error-bound of the system (≈5 mm) is visible at the boundary panes of the FOV. c, The spatial errors are plotted for Z = 18 cm plane and the presence of the higher error-bound of the system (yellow regions) is more prominent at the boundary planes of the FOV compared to the Z = 12 cm plane. The FOV ends at Z = 20 cm and the remaining half of the 40x40x40cm3 FOV is covered by the other set of the gradient coils shown in Fig. 4a.
Extended Data Fig. 3 X-Ray scans for fecal incontinence study.
a-r, Consecutive X-ray scans obtained while moving the iMAG (connected to a catheter) out of the anal sphincter in steps of five mm during the fecal incontinence study. Detailed results shown in Fig. 5a–c.
Extended Data Fig. 4 X-ray scans for magnetic label tracking.
a-p, Consecutive X-ray scans obtained while moving the iMAG (connected to a catheter) out of the anal sphincter in steps of five mm during the magnetic label (barium beads) tracking study. Detailed results shown in Fig. 5d–i.
Extended Data Fig. 5 iMAG trajectory compared to the meanders in colon.
a, Pig’s colon shown for comparison. b, iMAG trajectory from the fecal incontinence monitoring study. c, iMAG trajectory from the magnetic label tracking study. The two sharp bends in the rectum are prominently visible (highlighted by green arrows) in (a) and are captured by both the iMAG trajectories shown in (b) and (c). This shows that our technology can distinguish anatomical features for organs that are retroperitoneally fixed in the GI tract, like colon. The trajectory maps in (b) and (c) are created by plotting together all the decoded position coordinates of iMAG using the magnetic field measurements performed by it as it moves along the colon.
Extended Data Fig. 6 iMAG for smart toilets.
a, Front-view of the gradient coils assembly mounted on a toilet seat for continuous GI monitoring. b, Side-view of the toilet seat with the gradient coils. Two iMAG devices are placed in a tank filled with saline solution to demonstrate 3D localization. The experiment is repeated for n = 20 different locations of the iMAG devices in the FOV. c, Error obtained at all the locations is clustered together and plotted. d, Error at each location is plotted separately. Error reported as mean ± s.d.: 1.09 ± 1.29 mm (X), 1.25 ± 1.22 mm (Y), 0.95 ± 1.05 mm (Z). This prototype shows the ability of our technology to be deployed in common human-specific settings.
Supplementary information
Supplementary Information
Supplementary Figs. 1–15, Table 1 and links to videos for Extended Data Figs. 3 and 4.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Sharma, S., Ramadi, K.B., Poole, N.H. et al. Location-aware ingestible microdevices for wireless monitoring of gastrointestinal dynamics. Nat Electron 6, 242–256 (2023). https://doi.org/10.1038/s41928-023-00916-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/s41928-023-00916-0
This article is cited by
-
Clinical translation of wireless soft robotic medical devices
Nature Reviews Bioengineering (2024)
-
Miniaturized implantable temperature sensors for the long-term monitoring of chronic intestinal inflammation
Nature Biomedical Engineering (2024)
-
End-to-end design of ingestible electronics
Nature Electronics (2024)