Abstract
Thrombin generation (TG) and fibrin clot formation represent the central process of blood coagulation. Up to 95% of thrombin is considered to be generated after the clot is formed. However, this was not investigated in depth. In this study, we conducted a quantitative analysis of the Thrombin at Clot Time (TCT) parameter in 5758 simultaneously recorded TG and clot formation assays using frozen plasma samples from commercial sources under various conditions of activation. These samples were supplemented with clotting factor concentrates, procoagulant lipid vesicles and a fluorogenic substrate and triggered with tissue factor (TF). We found that TCT is often close to a 10% of thrombin peak height (TPH) yet it can be larger or smaller depending on whether the sample has low or high TPH value. In general, the samples with high TPH are associated with elevated TCT. TCT appeared more sensitive to some procoagulant phenotypes than other commonly used parameters such as clotting time, TPH or Thrombin Production Rate (TPR). In a minority of cases, TCT were not predicted from TG parameters. For example, elevated TCT (above 15% of TPH) was associated with either very low or very high TPR values. We conclude that clotting and TG assays may provide complementary information about the plasma sample, and that the TCT parameter may serve as an additional marker for the procoagulant potential in plasma sample.
Similar content being viewed by others
Introduction
Blood coagulation results in clot formation which prevents blood loss from damaged vessels and has other functions in vessel development and repair. The currently available functional hemostasis assays focus on detection of ether fibrin clot formation or generation of thrombin activity.
Assays based on clot formation include the commonly used tests of plasma clotting time, e.g., Activated Partial Thromboplastin Time (aPTT) and Prothrombin Time (PT)1 as well as point-of care methods that measure blood clot elasticity2,3. The kinetics of clot formation in plasma can also be extracted from the clot turbidity (light absorbance) data in an aPTT- and PT-based Clot Waveform analysis method or microplate-based clot formation and fibrinolysis assays. However, these Fibrin Generation (FG) clot-based assays capture only a portion of the events that take place during blood coagulation because clot formation is rapid and short-lived compared to the substantially longer process of thrombin generation4.
Assaying the kinetics of thrombin generation (TG) during clotting of blood plasma is widely used for clinical and scientific research purposes5,6. The most frequently used approach to measure TG is to measure fluorescence from 7-amino-4-methylcoumarine (AMC) following cleavage of an synthetic thrombin specific substrate by generated thrombin7,8. Investigation of thrombin is diagnostically relevant since thrombin provides the enzymatic reaction of clot formation, plays a central role in the positive and negative feedback loops of the coagulation cascade [4] and participates in many other related functions, including regulation of fibrinolytic system, activation of platelets, stimulation of repair mechanisms on endothelial cells and inflammation responses.
In commonly used clot-based and TG-based methods, two main processes of blood coagulation – clot formation and TG – are investigated independently. Although occasional reports aimed to measure clot formation and TG simultaneously9,10,11,12,13,14, there is no a wide-spread assay in which TG and Fibrin Generation (FG) are measured simultaneously. Moreover, the TG/FG assays in the aforementioned reports analyzed TG and FG parameters separately. A single parameter that would incorporate both of FG and TG has not yet been published and investigated. Though TG and FG frequently do not correlate with each other, they are biochemically closely related. A parameter that reflects TG and FG relationship could provide more information about the regulation of blood coagulation as it would be sensitive to both TG and FG.
In this study, we examine a parameter that incorporates both TG and FG, namely, the concentration of thrombin measured at the time of clot formation or, in other words, Thrombin at Clot Time (TCT). Besides providing information on TG and FG, the parameter TCT has additional utility. For example, TCT may indicate concentration of thrombin for which diffusion is not limited by adsorbtion to clot, compared to diffusion of thrombin that is generated after the clot is formed. The hypothesis that thrombin generated prior to fibrin clot formation diffuses more rapidly than thrombin generated inside a clot is supported by previous studies [15, 16, 17, 18, 19]. Coagulation proteases inside the fibrin clot were shown to diffuse slower than ones in the unclotted plasma15. Similarly, adsorption of thrombin to fibrin reduces thrombin generation by plasma16,17,18,19. Thus, assessing TCT possibly allows estimating thrombin amount that can propagate through the blood vessel. The propagation of the clot is investigated directly by spatial-resolved assay systems (e.g., thrombodynamics), but they are not widely used because of their complexity20,21. Furthermore, fibrin clot structure was also shown to depend on the concentration of thrombin that cleaves fibrinogen22. Higher thrombin concentrations produce relatively less turbid and less permeable fibrin clots while the clot produced by lower concentrations of thrombin is more permeable and less stable23,24,25. Thus, measuring TCT in a simultaneous TG/FG assay may be useful for indirect assessment of the stability and permeability of fibrin clots in tested samples.
Among the reasons TCT was missed out (aside from the lack of usage of simultaneous TG/FG measurement systems), is the prevailing belief that rapid TG phase starts after fibrin clot formation. Indeed, pioneering studies of Mann et al.26 showed that up to 90% of all generated thrombin is formed inside the clot. This has led to an assumption that only a small fraction of thrombin is generated prior to clot formation. However, Mann’s whole blood studies26 did not use the conditions8,27 that are conventional in TG assays. Furthermore, the influence of coagulation factors and inhibitors on thrombin concentration at clot time was not investigated. In the present study, we have analyzed 5758 simultaneous TG/FG measurements carried out in our laboratory under a wide range of triggering conditions and in the presence of various coagulation agents at different concentrations. In these experiments, we calculated absolute TCT values in nanomoles (aTCT) and the ratio between TCT and Thrombin Peak Height in percent (rTCT, TPH correspondingly). We evaluated the dependence of TCT on various experimental conditions in comparison with commonly used TG parameters such as TPH and Thrombin Production Rate (TPR). Taken together our findings indicate that TCT can be a useful additional parameter for the identification of abnormalities in blood coagulation.
Results
Representative TG and FG curves with different TCT values
TG measurements from 5758 samples were analyzed. Most of these experiments were focused on: (i) effects of wild type and bioengineered variants of recombinant Factor VIIa (rFVIIa) in Factor VIII-deficient plasma28, (ii) effects of addition of normal plasma to FVIII deficient plasma, (iii) effects of Factor IX (FIX) and IXa (FIXa) on FIX-deficient and normal plasma12, (iv) effects of platelet-derived microvesicles (PMV) on normal plasma, (v) effects of activated Factor XI (FXIa) contamination in immune globulin products on FXI-deficient plasma11,29, and (vi) effect of calcium chloride on TG in normal plasma30 (Fig. S1). Additional studies with fewer samples that were used in our analyses are shown in Table S1. All experimental conditions and TG parameters values can be found in the Table S3. Figure 1 exemplifies the variety of the conditions and results obtained. In some samples 90% of thrombin was indeed generated after clot time (TCT values about 10% of TPH, Fig. 1a, Fig. S2a–d), as could be expected from previous observations26. However, in some experiments, the TCT values were 15% of TPH or higher (Fig. 1a, Fig. S2e–i), indicating that a considerable fraction of TG may occurs prior to the formation of fibrin clot. Our observations show, that elevated thrombin generation prior to clot formation can occur when the TPH value is high (Fig. 1a, Fig. S2e–h) or extremely low (Fig. 1b, Fig. S2i). The conditions of each experiment can be found in Table S2.
Under certain conditions, thrombin generation during clot formation reaches comparatively high values
A distribution of TCT values for all 5758 analyzed samples is depicted in Fig. 2a. The median TCT value was observed at ~ 5% of the TG peak. A majority of samples had TCTs below 10% of the peak which is consistent with the previous study26 that showed 90% of TG occurs after clot formation. Nonetheless a tail of the distribution was formed by a group of samples with TCT values > 15% of TPH (Fig. 2a). The value 15% was chosen as a cut-off for a Control group (4898 samples with TCT < 15%, 85.1% of total). We compared the Control group and and the group of samples that formed the tail and found that the samples with TCT >15% demonstrate greater diversity (Figure 2b). In Fig. 2c, we identify 3 peaks in the group with a relative TCT of > 15%, stratified on the basis of the absolute TCT value (aTCT): aTCTs with values < 10 nM (LowTCT group), aTCTs with values between 10 and 40 nM (MedTCT group), and aTCTs with values > 40 nM (HighTCT group). A change in TCT cut-off value for control group qualitatively did not change TCT distribution in the subpopulation of TCT values elevating the border (Fig. S3). Table 1 shows the number of samples in each of these three groups and compared to the Control group.
Potential association between TCT values and hyper- and hypo- coagulation states
Figure 3 demonstrates that the LowTCT (< 10 nM) group has significantly higher clot times (Fig. 3a), significantly lower TPHs (Fig. 3b) and significantly lower TPRs (Fig. 3c) compared to the Control group. Collectively, these data indicate reduced coagulation activity in the plasma samples from the LowTCT group. Both MedTCT and HighTCT groups have significantly higher TPH (Fig. 3b) and TPR (Fig. 3c) compared to the Control group suggesting hypercoagulation.
Correlations between TPH and TCT values for the Control, LowTCT, MedTCT and HighTCT groups
We found that aTCT correlated well with TPH for the control, LowTCT, and MedTCT groups, but not for the HighTCT group (Fig. 4a,c,e,g). These results indicate that aTCT values can be predictive of TPH when certain conditions are met.. Importantly, a correlation between rTCT and TPH was not observed (Fig. 4b,d,f,h).
TCT value depends on the presence of procoagulant agents
This study includes analysis of samples supplemented with procoagulant (FVIIa, FIX, FIXa, FXIa, TF) and/or anticoagulant agents at various concentrations. To investigate how TG parameters reflect the potential procoagulant activity caused by addition of multiple agents, we established an in-house procoagulant score (PS) for each experiment. PS was designed as a sum of so called “procoagulant and anticoagulant markers” that corresponded to added pro- and anticoagulant agents and their concentrations (Table 2). Each procoagulant marker adds 1 to PS. Conversely, each anticoagulant marker subtracts 1 from the PS. These markers were set with respect to known normal concentrations of procoagulant and anticoagulant agents used in the study. A plasma with a factor deficiency was considered having an anticoagulant markers as opposed to plasmas from healthy donors (procoagulant markers). The agents with weak effect on TG (Corn Trypsin Inhibitor, Carboxypeptidase Inhibitor, Fibrinogen) were excluded from PS. To illustrate the PS calculation, consider the experiment performed in FVIII-deficient plasma supplemented with 200 nM FVIIa, 0.5 pM TF and 4 μM of phospholipids. The PS is calculated by summing individual contributions: − 1 (FVIII-deficient plasma) + 1 (FVIIa addition) + 1 (FVIIa ≥ 200 nM) resulting in a PS of 1. Following PS calculation, we correlated PS with the observed TPH, TPR and aTCT values.
Figure 5 shows correlations of PS and TG parameters (TP, TPR and aTCT) for all experiments included in the study. All three parameters differ in the PS range from below 0 to 1 and when PS reaches 3. However, the mean and median values from different TG parameters tend to reflect PS differently (Table S2). TPR and aTCT were more sensitive to change in PS.
Examples of interplay between TCT, TPH and TPR. FIX titration in FIX deficient plasma
To evaluate utility of TPH, TRP, aTCT, and rTCT we analyzed sensitivity of these parameters to procoagulant stimuli. Figure 6 demonstrates the example of responses of TPH (Fig. 6a), TPR (Fig. 6b) and TCT (Fig. 6c–d) to increasing concentrations of FIX added to FIX-deficient plasma. At the FIX concentrations below 0.01 IU/ml (severe hemophilia B31,32), TPH and TPR demonstrate higher sensitivity to FIX than aTCT and rTCT. In contrast, at FIX concentrations above 0.01 IU/mL (which corresponds to moderate and mild hemophilia B32), TCT demonstrates better sensitivity to FIX concentrations.
Examples of interplay between TCT, TPH and TPR. TG phospholipid vesicles titration in normal plasma
Figure S4 shows the dependencies of TPH (Fig. S4a), TPR (Fig. S4b), aTCT and rTCT (Fig. S4c-d) on the concentration of commercially available phospholipids that are used in TG assay to boost thrombin formation. In line with Fig. 6, in the case of titration of phospholipids, aTCT and rTCT demonstrates high sensitivity to the higher concentrations of an added agent.
Examples of interplay between TCT, TPH and TPR. Two types of FVIIa titration in FVIII deficient plasma
Figure S5 demonstrates a response of TG assay in FVIII deficient plasma to increasing concentrations of human recombinant FVIIa33 and its bioengineered analog (NN1731)34. In this case, TPH and TPR were sensitive to both types of FVIIa in the wide range of concentrations (Fig. S5a–b). However, they do not show a large difference between each type. In contrast, aTCT and rTCT were sensitive to 100–1000nM NN1731, but not to recombinant wild type FVIIa.
Discussion
In the present study, we evaluated 5,758 simultaneously recorded TG and clot formation assays carried out under various conditions. In the past, it was believed that only negligible amounts of thrombin are generated at (or prior to) the time of clot formation22,26. In approximately 15% of the evaluated assays, thrombin levels generated prior to clot formation can reach substantial values compared to TPH. Importantly, thrombin generation prior to clot formation is associated with abnormal conditions of hypo- and hypercoagulability. Our results suggest that TCT could be a valuable parameter to study various coagulopathies.
We hypothesize, that abnormal TCTs in samples with decreased or elevated procoagulant activity may be a result of imbalance in thrombin and fibrin production rates. Specifically, in cases with reduced procoagulant or increased anticoagulant activity in plasma, lower rates of thrombin generation may have a significantly greater impact on reducing TPH than TCT, because as few as several nM of thrombin are sufficient to form a fibrin clot22. Conversely, if thrombin is generated rapidly, but the rate of clot formation is limited by the concentration of fibrinogen and fibrin polymerization, the concentration of thrombin generated before the clot is formed, can reach high aTCT and rTCT.
In this study we demonstrated that the amount of thrombin formed at clot time (TCT) can be used as an additional parameter of TG to study mechanisms of action of various coagulation agents used in clinics and research. In development of our in-house PS, we attempted to evaluate potential complex effects of different conditions on TG/FG assays. However, the results of some experiments did not match predictions of PS. In many cases experiments with the same PS differed a lot in at least one of parameters (Fig.S4c–d). This can be explained by the fact that many agents that have similar mechanism of action and were assigned the same procoagulant score, in practice, resulted in different TG responses, like it was with two types of FVIIa in Fig. S5. But finally, taken together to the groups with same PS, TG parameters significantly differed between these groups indicating correlation of our in-house designed PS with procoagulant activity (Fig. 5).
Our study included samples where sensitivities of different parameters of TG/FG assay to one agent (e.g., FXIa, FVIIa, FIX) depend on its type and concentration (Figs. 6, S4, S5, more examples can be found in Table S3). The agents that were used in the study act in different coagulation pathways, and therefore can affect TCT, TPH, and TPR in different ways. For instance, when TCT shows higher sensitivity than TPH or TPR, we show that TCT provides an additional tool to evaluate the action of coagulation agents with various mechanisms of action.
In the present study we calculated clot time as the time when optical density from fibrin clot reaches 45% level of its maximal value. Our method to determine CT is consistent with the approach used in some previously published studies9,10. The approach to determining clot time, however, varies across instruments, assays, and investigators. For example, clot time can be determined as the time when the optical density reaches its maximum absorbance35, or determined as the point when the second derivative of the absorbance curve reaches it’s maximum, as it is done in ACL TOP analyzers. The method used to calculate CT could affect the absolute values of TCT but does not qualitatively change the relation of high TCT with high procoagulant activity of plasma (Fig. S6).
The use of TCT parameter has some limitations, that arise from the requirement to measure fluorescence and absorbance simultaneously. A condition that affect fibrin formation potentially may alter clot time, and, as a result TCT. For example, the use of Tissue Plasminogen Activator (tPA) is common in assays that also measure generation of plasmin aiming to evaluate fibrinolysis13,14,36,37,38,39,40. Addition of high concentrations of tPA can affect fibrin concentration and, as a result, light absorption, which can strongly affect the calculation of clot time. The interference of fibrinolysis with clot formation can be minimized by reducing tPA concentration in the reaction mixture. The second limitation arises from the low reading speed (2 to 4 times per minute) of typical plate readers which are used to record the fast transition between the liquid phase (plasma) and the clot. The low time resolution of clot formation results in only a few measurements per transition, and may result in high variability and low reproducibility of CT and of TCT. Development of high-speed readers would overcome this issue.
In our study, we, for the first time, investigated the amount of thrombin that can be generated by the time of clot formation under various conditions. We showed that under lack or excess of coagulation activity, TCT can reach significant values compared to the peak of thrombin. TCT is a promising parameter that can be used in the future studies aiming to investigate abnormal coagulation activity as well as to evaluate effects of various coagulation agents.
Materials and methods
Study design
TG/FG assay was performed as previously described10. Briefly, blood plasma (50% vol/vol in the final reaction) was substituted with 800 μM of thrombin specific fluorogenic substrate Z-Gly-Gly-Arg-AMC (Bachem Americas, King of Prussia, PA, USA) and Tris-BSA buffer (pH 7.4, Aniara, West Chester, Ohio, USA). Coagulation trigger for each experiment was added as in Table S3. Clotting was initiated by CaCl2 (20.0%, 10 mM final concentration for the most of experiments). Fluoresence (380 nm excitation, 430 nm emission) and absorbance were recorded at 380 nm excitation, 430 nm emission, and 492 nm correspondingly. The Clot Time was calculated as the time when optical density from fibrin clot reaches 45% of its maximal value (Fig. 7). All the agents used in all 5758 experiments analyzed in this study are listed in Table S3 and that sources of them are available upon request. For all calculations MS Excel (Microsoft, Redmond, WA, USA) and Origin (Origin Lab, Northampton, MA, USA) software were used. To obtain statistics, we used Mann–Whitney U-test with P set as 0.05 with Bonferroni correction. In the present study, only commercially available human plasmas were used, and no humans were directly involved.
Data availability
The original datasets that were used in the study are available in Table S3 and from the corresponding author.
References
Narayanan, S. Preanalytical aspects of coagulation testing. Haematologica 80, 1–6 (1995).
Othman, M. & Kaur, H. Thromboelastography (TEG). Methods Mol. Biol. 1646, 533–543. https://doi.org/10.1007/978-1-4939-7196-1_39 (2017).
Sakai, T. Comparison between thromboelastography and thromboelastometry. Minerva. Anestesiol. 85, 1346–1356 (2019).
Negrier, C., Shima, M. & Hoffman, M. The central role of thrombin in bleeding disorders. Blood Rev 38, 100582. https://doi.org/10.1016/j.blre.2019.05.006 (2019).
Tripodi, A. Thrombin generation assay and its application in the clinical laboratory. Clin Chem 62, 699–707. https://doi.org/10.1373/clinchem.2015.248625 (2016).
Kintigh, J., Monagle, P. & Ignjatovic, V. A review of commercially available thrombin generation assays. Res. Pract. Thromb. Haemost. 2, 42–48. https://doi.org/10.1002/rth2.12048 (2018).
Hemker, H. C. et al. Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol. Haemost. Thromb. 33, 4–15. https://doi.org/10.1159/000071636 (2003).
Al Dieri, R., De-Laat, B. & Hemker, H. C. Thrombin generation what have we learned?. Blood Rev. 26, 197–203. https://doi.org/10.1016/j.blre.2012.06.001 (2012).
Nagashima, H. Studies on the different modes of action of the anticoagulant protease inhibitors DX-9065a and Argatroban. I. Effects on thrombin generation. J. Biol. Chem. 277, 50439–50444. https://doi.org/10.1074/jbc.M208222200 (2002).
Xin, K. Z., Chang, W. C. & Ovanesov, M. V. Interconnectedness of global hemostasis assay parameters in simultaneously evaluated thrombin generation, fibrin generation and clot lysis in normal plasma. Thromb. Res. 140, 132–139. https://doi.org/10.1016/j.thromres.2015.11.023 (2016).
Menis, M. et al. Hyperimmune globulins and same-day thrombotic adverse events as recorded in a large healthcare database during 2008–2011. Am. J. Hematol. 88, 1035–1040. https://doi.org/10.1002/ajh.23559 (2013).
Ekezue, B. F. et al. Clotting factor product administration and same-day occurrence of thrombotic events, as recorded in a large healthcare database during 2008–2013. J. Thromb. Haemost. 13, 2168–2179. https://doi.org/10.1111/jth.13155 (2015).
Miszta, A. et al. A high-fat diet delays plasmin generation in a thrombomodulin-dependent manner in mice. Blood 135, 1704–1717. https://doi.org/10.1182/blood.2019004267 (2020).
Bouck, E. G. et al. COVID-19 and Sepsis Are Associated With Different Abnormalities in Plasma Procoagulant and Fibrinolytic Activity. Arterioscler. Thromb. Vasc. Biol. 41, 401–414. https://doi.org/10.1161/ATVBAHA.120.315338 (2021).
Hathcock, J. J. & Nemerson, Y. Platelet deposition inhibits tissue factor activity: in vitro clots are impermeable to factor Xa. Blood 104, 123–127. https://doi.org/10.1182/blood-2003-12-4352 (2004).
Fredenburgh, J. C., Stafford, A. R., Pospisil, C. H. & Weitz, J. I. Modes and consequences of thrombin’s interaction with fibrin. Biophys. Chem. 112, 277–284. https://doi.org/10.1016/j.bpc.2004.07.031 (2004).
de Bosch, N. B., Mosesson, M. W., Ruiz-Saez, A., Echenagucia, M. & Rodriguez-Lemoin, A. Inhibition of thrombin generation in plasma by fibrin formation (Antithrombin I). Thromb. Haemost. 88, 253–258 (2002).
Mosesson, M. W. & Antithrombin, I. Inhibition of thrombin generation in plasma by fibrin formation. Thromb. Haemost. 89, 9–12 (2003).
Pitkanen, H. et al. Enhanced thrombin generation and reduced intact protein S in processed solvent detergent plasma. Thromb. Res. 135, 167–174. https://doi.org/10.1016/j.thromres.2014.10.020 (2015).
Dashkevich, N. M. et al. Thrombin activity propagates in space during blood coagulation as an excitation wave. Biophys. J. 103, 2233–2240. https://doi.org/10.1016/j.bpj.2012.10.011 (2012).
Panteleev, M. A. et al. Spatial propagation and localization of blood coagulation are regulated by intrinsic and protein C pathways, respectively. Biophys. J. 90, 1489–1500. https://doi.org/10.1529/biophysj.105.069062 (2006).
Wolberg, A. S. & Campbell, R. A. Thrombin generation, fibrin clot formation and hemostasis. Transfus. Apher. Sci. 38, 15–23. https://doi.org/10.1016/j.transci.2007.12.005 (2008).
Weisel, J. W. & Nagaswami, C. Computer modeling of fibrin polymerization kinetics correlated with electron microscope and turbidity observations: clot structure and assembly are kinetically controlled. Biophys. J. 63, 111–128. https://doi.org/10.1016/S0006-3495(92)81594-1 (1992).
Ryan, E. A., Mockros, L. F., Weisel, J. W. & Lorand, L. Structural origins of fibrin clot rheology. Biophys. J. 77, 2813–2826. https://doi.org/10.1016/S0006-3495(99)77113-4 (1999).
Kaibara, M. & Fukada, E. The influence of the concentration of thrombin on the dynamic viscoelasticity of clotting blood and fibrinogen-thrombin systems. Biorheology 8, 139–147. https://doi.org/10.3233/bir-1971-83-404 (1971).
Mann, K. G., Brummel, K. & Butenas, S. What is all that thrombin for?. J. Thromb. Haemost. 1, 1504–1514. https://doi.org/10.1046/j.1538-7836.2003.00298.x (2003).
Hemker, H. C. et al. The calibrated automated thrombogram (CAT): a universal routine test for hyper- and hypocoagulability. Pathophysiol. Haemost. Thromb. 32, 249–253. https://doi.org/10.1159/000073575 (2002).
Jankowski, W. et al. Mitigation of T-cell dependent immunogenicity by reengineering factor VIIa analogue. Blood Adv. 3, 2668–2678. https://doi.org/10.1182/bloodadvances.2019000338 (2019).
Sridhar, G. et al. Immune globulins and same-day thrombotic events as recorded in a large health care database during 2008 to 2012. Transfusion 54, 2553–2565. https://doi.org/10.1111/trf.12663 (2014).
Parunov, L. A., Surov, S. S., Liang, Y., Lee, T. K. & Ovanesov, M. V. Can the diagnostic reliability of the thrombin generation test as a global haemostasis assay be improved? The impact of calcium chloride concentration. Haemophilia 23, 466–475. https://doi.org/10.1111/hae.13174 (2017).
Franchini, M. & Mannucci, P. M. Modifiers of clinical phenotype in severe congenital hemophilia. Thromb. Res. 156, 60–64. https://doi.org/10.1016/j.thromres.2017.05.038 (2017).
Dolan, G. et al. Haemophilia B: Where are we now and what does the future hold?. Blood Rev. 32, 52–60. https://doi.org/10.1016/j.blre.2017.08.007 (2018).
Hedner, U. NovoSeven as a universal haemostatic agent. Blood Coagul. Fibrinolysis. 11(Suppl 1), S107-111. https://doi.org/10.1097/00001721-200004001-00020 (2000).
Allen, G. A. et al. A variant of recombinant factor VIIa with enhanced procoagulant and antifibrinolytic activities in an in vitro model of hemophilia. Arterioscler. Thromb. Vasc. Biol. 27, 683–689. https://doi.org/10.1161/01.ATV.0000257204.82396.2b (2007).
Gidley, G. N. et al. Abnormal plasma clot formation and fibrinolysis reveal bleeding tendency in patients with partial factor XI deficiency. Blood Adv. 2, 1076–1088. https://doi.org/10.1182/bloodadvances.2017015123 (2018).
Tarandovskiy, I. D., Rajabi, A. A., Karnaukhova, E. & Buehler, P. W. Contradictory to its effects on thrombin, C1-inhibitor reduces plasmin generation in the presence of thrombomodulin. J. Thromb. Thrombol. 48, 81–87. https://doi.org/10.1007/s11239-019-01869-y (2019).
Tarandovskiy, I. D., Shin, H. K. H., Baek, J. H., Karnaukhova, E. & Buehler, P. W. Interspecies comparison of simultaneous thrombin and plasmin generation. Sci. Rep. 10, 3885. https://doi.org/10.1038/s41598-020-60436-1 (2020).
van Geffen, M. et al. Alterations of coagulation and fibrinolysis in patients with angioedema due to C1-inhibitor deficiency. Clin. Exp. Immunol. 167, 472–478. https://doi.org/10.1111/j.1365-2249.2011.04541.x (2012).
van Geffen, M. et al. A novel hemostasis assay for the simultaneous measurement of coagulation and fibrinolysis. Hematology 16, 327–336. https://doi.org/10.1179/102453311X13085644680348 (2011).
Matsumoto, T., Nogami, K. & Shima, M. Simultaneous measurement of thrombin and plasmin generation to assess the interplay between coagulation and fibrinolysis. Thromb. Haemost. 110, 761–768. https://doi.org/10.1160/TH13-04-0345 (2013).
Author information
Authors and Affiliations
Contributions
I.D.T. wrote the article, analyzed the results, made figures and tables, S.S.S., L.A.P., Y.L. performed T.F./F.G. experiments, W.Y. made FVIIa bioengineering, ZES and MVO supervised the project and edited the article.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Tarandovskiy, I.D., Surov, S.S., Parunov, L.A. et al. Investigation of thrombin concentration at the time of clot formation in simultaneous thrombin and fibrin generation assays. Sci Rep 14, 9225 (2024). https://doi.org/10.1038/s41598-023-47694-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-47694-5
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.