Abstract
Optical coherence tomography angiography (OCTA) provides three-dimensional structural and semiquantitative imaging of microvasculature in vivo. We developed an OCTA imaging protocol for a murine kidney ischemia–reperfusion injury (IRI) model to investigate the correlation between renal microvascular changes and ischemic damage. Mice were divided into mild and moderate IRI groups according to the duration of ischemia (10 and 35 mins, respectively). Each animal was imaged at baseline; during ischemia; and at 1, 15, 30, 45, and 60 mins after ischemia. Amplitude decorrelation OCTA images were constructed with 1.5-, 3.0-, and 5.8-ms interscan times, to calculate the semiquantitative flow index in the superficial (50–70 μm) and the deep (220–340 μm) capillaries of the renal cortex. The mild IRI group showed no significant flow index change in both the superfial and the deep layers. The moderate IRI group showed a significantly decreased flow index from 15 and 45 mins in the superficial and deep layers, respectively. Seven weeks after IRI induction, the moderate IRI group showed lower kidney function and higher collagen deposition than the mild IRI group. OCTA imaging of the murine IRI model revealed changes in superficial blood flow after ischemic injury. A more pronounced decrease in superficial blood flow than in deep blood flow was associated with sustained dysfunction after IRI. Further investigation on post-IRI renal microvascular response using OCTA may improve our understanding of the relationship between the degree of ischemic insult and kidney function.
Similar content being viewed by others
Introduction
Acute kidney injury (AKI) is a common risk factor associated with various etiologies of kidney dysfunction1. Despite continuing efforts to improve the diagnostic criteria for AKI2,3, it remains as a critical clinical problem without clearly defined therapeutic or preventive solutions. Various animal models for AKI have been developed to investigate the pathophysiology and identify new treatments. Among them, rodent ischemia–reperfusion injury (IRI) models have frequently been used to evaluate the basic mechanisms of AKI owing to their relatively reproducible nature4,5,6.
Ischemic injury triggers necrosis of proximal tubule cells, structural alteration of the endothelium, and inflammatory response7,8. Capillary rarefaction, a reduction in vascular density, is associated with renal fibrosis and progressive kidney dysfunction9,10,11. Decreased perfusion from capillary rarefaction can exacerbate tubular injury and induce chronic tissue hypoxia, which consecutively leads to irreversible fibrosis12. Microvascular changes after IRI have been studied using various diagnostic techniques, such as ultrasound, computed tomography, magnetic resonance imaging, and angiography13,14,15,16. Various indicators were introduced to evaluate microvascular distribution, such as quantitative analysis, perfusion signals, and fluorescence. However, changes in microvascular flow rate and the relationship between capillary blood flow and kidney injury are unknown in the IRI models.
Optical coherence tomography (OCT) is an imaging modality that can noninvasively visualize three-dimensional micron-scale structures of in vivo tissues. Although OCT has been most widely applied in ophthalmology and cardiology, limited number of studies have used OCT to image human kidneys17,18 and investigated the correlation between microtubular features and allograft function19. Advances in high-speed OCT in the last decade have enabled rapid repeated B-scanning of the same positions in the tissue, by which moving erythrocytes in the blood vessels can be separately highlighted. This emerging method, named OCT angiography (OCTA)20,21, provides label-free imaging of microvascular structures. Furthermore, since OCTA signal is positively correlated with the distance traveled by the erythrocytes, relative blood flow speeds can be distinguished if the time intervals between the repeated B-scans (interscan times) are adequately configured. When applied to a rodent kidney IRI model, this semiquantitative capillary flow speed imaging capability can provide useful information on the pathophysiology of ischemic AKI.
In this paper, we present a high-speed OCTA system for repeatable monitoring of the mouse kidney microcirculation and semiquantitative OCTA technique for microvascular flow speed estimation in a murine IRI model. Capillary flow speeds in the peritubular and glomerular vasculature were regularly evaluated during the first 60 mins after reperfusion in IRI with varying durations of ischemia using the OCTA system. The correlation between OCTA time-course measurements in the renal microvasculature upon reperfusion and later confirmed ischemic damage represented by biochemical and histopathological analyses was investigated.
Materials and methods
OCTA instrumentation
The raw data required for generating OCTA images were acquired using a previously reported swept-source OCT system22 based on a lab-built short-cavity laser with a 220.4-kHz sweep rate (Fig. 1A). The optical output of the laser was centered at 1300 nm with a 104-nm bandwidth, which corresponds to an 8.4-μm axial resolution in tissue. The scanning beam diameter was 4.9 mm at the 30-mm objective lens input, corresponding to an 8.2-μm transverse resolution in tissue. The optical interference signal was converted into an electric signal by a balanced receiver and recorded by a digitizer internally clocked at a 400-MHz sampling rate, resulting in a 3.3-mm digital imaging range. An acousto-optic frequency shifter was inserted in the reference arm to move the maximum coherence position away from the zero-delay line, thererby enhancing the signal at deeper imaging depths. The resulting system sensitivity was 102 dB, with a 6-dB roll-off measured at 3.2-mm imaging depth in the tissue.
IRI induction and imaging protocol
A dorsal bilateral IRI model23 was established in 8-week-old male C57BL/6 mice. The mice underwent inhalation anesthesia (isoflurane 1–3%), followed by renal ischemia induction by clamping both renal arteries using a micro-serrefine with a 50–110 g pressing weight (RS-5422, Roboz Surgical Instrument Company, Inc. Gaithersburg, Maryland, USA). A similar surgical procedure without renal pedicle clamping was performed in sham-operated mice. During operation, the animals were maintained at 36.5–37 °C using a temperature-controlled heating device (Harvard Bioscience, Holliston, MD, USA). The mice were divided into the mild IRI group (n = 8) and moderate IRI group (n = 9) according to the duration of ischemia (10 and 35 mins, respectively). The kidneys were imaged using OCTA at baseline (before ischemia), during ischemia, and at 1, 15, 30, 45, and 60 mins after reperfusion. Because OCTA utilizes motion contrast, a ring-shaped custom fixing tool was developed to suppress breathing and pulsating motion (Fig. 1B). A water droplet was applied inside the ring to move surface specular reflections out of the OCT imaging depth window. All animal handling procedures were approved and supervised by the Korea Advanced Institute of Science and Technology Institutional Animal Care and Use Committee.
Semiquantitative OCTA scanning and image processing
The OCTA scanning procedure and the image processing software were designed to achieve a roughly proportional relationship between the OCTA flow index and actual capillary flow speed24,25. Previous reports have shown that under the same imaging conditions, amplitude decorrelation—defined as the mean of normalized squared differences—shows a monotonic relationship with the ensemble mean of the distance traveled by the red blood cells up to a certain saturation distance determined by the optical resolution element26,27. Because the mean distance is proportional to the time interval between the two B-scans, the interscan time can be changed to adjust the measurable flow speed range. Therefore, we imaged the kidney using three raster scan patterns with different interscan times: raster scans comprising 256 × 256 A-scans (1.5-ms interscan time), 512 × 512 A-scans (3.0-ms interscan time), and 1024 × 1024 A-scans (5.8-ms interscan time), respectively (Fig. 2A–C). Each B-scan position was repeated three times, allowing two normalized squared difference images to be averaged to yield the OCTA signal. The maximum projection of the OCTA signals, located at superficial (50–70 μm from the surface) and deep (320–340 μm from the surface) depth ranges, measured from the automatically segmented kidney surface, were generated. For each depth range, the maximum OCTA projections obtained from the different scan patterns were summed to construct the final semiquantitative OCTA image (Fig. 2D). All three images (256 × 256, 512 × 512, and 1024 × 1024) were summed for the superficial capillaries, whereas only 256 × 256 and 512 × 512 images were summed for the deep capillaries because of OCTA signal saturation at high flow speeds. The semiquantitative OCTA images can be mapped onto pseudocolor to enhance the contrast for visual inspection (Fig. 2E). The flow index was defined as the total sum of OCTA signals across the circular region of interest. All flow indices were normalized with respect to the baseline value to remove the effect of intersubject variation in absolute blood flow.
Renal function and histopathological studies
All mice were euthanized by cardiac puncture under anesthesia 7 weeks after reperfusion. Blood samples and the kidneys were collected for analysis. After centrifuging each blood sample, the serum underwent biochemical analysis. Blood urea nitrogen (BUN) and creatinine (Cr) levels were assessed by GC Labs (Yongin, Republic of Korea) using a Cobas 8000 modular analyzer system (Roche, Germany).
Kidney tissues from each experimental group were fixed with 4% paraformaldehyde (pH 7.4) and embedded in paraffin. 2-µm tissue sections were prepared and stained with Masson’s trichrome using standard protocols to determine histological changes and collagen deposition. Collagen deposition was quantified as a percentage of the total area using iSolution DT image software (IMT iSolution, Vancouver, Canada) in more than nine randomly selected fields in the cortex and medulla sections. For immunohistochemical staining, 2-μm-thick kidney sections were deparaffinized and rehydrated, and endogenous peroxidase was inactivated with 3% hydrogen peroxide. The samples were incubated with anti-CD31 (1:200; ab182981, Abcam) overnight at 4 °C and then detected using the EnVision-HRP kit (Dako, Carpinteria, CA, USA). To quantify CD31 expression, the marked cells were counted in nine non-overlapping fields imaged at 400 × magnification and divided by the area of the field of view for each slide.
Statistical analysis
Data are specified as the mean ± standard error of the mean. Statistical analyses were performed using GraphPad Prism 5.01 (GraphPad Software, Inc., La Jolla, CA, USA). The difference in flow index between baseline and each reperfusion time was analyzed using the Wilcoxon test. The difference of the flow index between each datapoint and the baseline was analyzed using a nonparametric Mann-Whitney test with the significance level set at p < 0.05.
Ethics approval
All animal handling procedures were approved by the Korea Advanced Institute of Science and Technology Institutional Animal Care and Use Committee and performed in accordance with the relevant guidelines and regulations. All procedures followed the recommendations of the ARRIVE guidelines49.
Results
Figure 3 shows representative examples of the semiquantitative OCTA blood flow measurements in the IRI model. The OCTA blood flow signal completely disappeared during ischemia in both the superficial and the deep layers. One minute after reperfusion, the blood flow recovered to a level similar to that at baseline in both layers.
The behavior of the mean and its standard error of the flow indices in each group is shown in Fig. 4. OCTA flow index recovery showed contrasting trends between the mild and moderate IRI groups. The mild IRI group did not manifest a significant change in the OCTA flow index from baseline starting from 1 to 60 mins after reperfusion. The deep layer also did not show a decrease in flow at any time point after 1 min in the mild IRI group. In the moderate IRI group, superficial capillary flow recovered 1 min after reperfusion. However, superficial flow significantly decreased from 15 to 60 mins. Deep capillary flow presented a slightly delayed response, showing a significant decrease at 1 min and then at 45–60 mins after reperfusion. The amount of flow index change was more pronounced in the superficial layer than in the deep layer. Superficial blood flow was noticeably lower in the moderate IRI group than in the mild IRI group from 15 min after reperfusion. However, deep blood flow did not show a large difference between the mild and moderate IRI groups.
Seven weeks after IRI induction, biochemical blood tests and histological analyses were performed to confirm the relationship between ischemic injury and kidney function. The moderate IRI group showed a significant increase in serum BUN and Cr levels compared to the sham and mild IRI groups (Fig. 5A, B). Tubular damage and fibrosis were also increased in the moderate IRI group (Fig. 5C). Quantification of fibrosis by trichome staining showed significantly larger area of collagen deposition in the moderate IRI than in the mild IRI group. In order to investigate the relationship between reperfusion and kidney function, correlation analyses were performed between the superficial and deep OCTA flow indices, respectively, and the collagen area percentage (Fig. 6). The mean of the 45-min and 60-min flow indices were taken as a representative of the short-term capillary reperfusion. Superficial flow index exhibited a noticeably stronger correlation (R2 = 0.75) while deep flow index only showed a weak correlation (R2 = 0.46).
Vascular damage was confirmed by quantification of CD31 immunostaining 7 weeks after ischemia. When a long depth range in the renal cortex was analyzed, vascular rarefaction was observed in both the mild and the moderate IRI groups (Fig. 7A). CD31 immunostaining decreased significantly in the mild and the moderate IRI groups compared to those in the sham group (Fig. 7B). When the renal cortex was divided into superficial and deep layers according to the OCTA depth range, the CD31-positive area was significantly smaller in the superficial layer than in the deep layer (Fig. 7C, D).
Discussion
We established a high-speed OCTA system to measure the change in microvascular flow speed in a murine kidney IRI model. The OCTA system immediately detected the ischemia and the reperfusion status. Microvascular flow in the superficial and the deep layers showed different change patterns with respect to the duration of ischemia: superficial blood flow was more vulnerable to ischemic injury than deep blood flow. Changes in renal microvascular flow were associated with decreased kidney function, tubular damage, and collagen deposition 7 weeks after IRI. Therefore, this study suggests that OCTA can predict chronic kidney dysfunction through repeated noninvasive evaluation of ischemic injury.
Microvascular injury is a risk factor of progressive kidney dysfunction. IRI results in microvascular damage and reduces vascular density in the kidneys28,29. This capillary rarefaction is directly related to tissue hypoxia, which aggravates tubule necrosis and limits recovery from ischemic injury30,31. Microvascular damage has been mainly investigated in an animal model by either evaluating vascular resistance32,33 or calculating capillary density34,35. However, limitations of morphometric studies with kidney histology such as the invasive procedures and the difficulty to obtain repeated or functional data have complicated their application to human kidneys.
Various diagnostic methods have been studied to replace histological evaluation of microvascular injury after IRI13,14,15,16. However, these methods have disadvantages when applied in clinical practice. For example, computed tomography14,36 and ultrasound methods13 necessitate intravenous contrast agents. Contrast agents for computed tomography are nephrotoxic and dense microbubbles of ultrasound contrast decrease the intensity of deeper tissue. These make it difficult to perform repeated measurements in patients with AKI. Microangiography requires ex vivo preparation, making it an invasive and unrepeatable assessment15,37. Functional magnetic resonance imaging, a probable substitute for computed tomography, can evaluate perfusion or kidney volume but its resolution is insufficient for assessing microvascular flow distribution16,38.
OCT technology was applied to analyze the microscopic structure of the kidney in a noninvasive manner. OCT is a rapidly emerging noninvasive imaging technique which performs an “optical biopsy,” providing cross-sectional and three-dimentional tissue morphology without any contrast agents39. Wang et al., showed that OCT could provide real-time imaging of hypertrophic tubular structures in a rat model treated with intravenous Adriamycin17,40. They also performed a combined analysis of Doppler and structural OCT images to quantify blood flow in vivo41. Doppler OCT allowed noninvasive imaging of glomerular blood flow in rat kidneys. However, as discussed above, peritubular capillary rarefaction—rather than glomerular hypoxia—is a hallmark of the transition from AKI to chronic kidney dysfunction42. Deeper vascular beds are more difficult to assess with Doppler OCT because it requires relatively high signal-to-noise ratio and high field autocorrelation between adjacent A-scans. Also, Doppler OCT is not the optimal method for repeatable microvascular flow measurements due to its angle-dependence and insensitivity to transverse blood flow. Meanwhile, semi-quantitative OCTA can target microvascular distuributions of the interstitium, although some glomerular blood flow may be involved. Thus, compared to Doppler OCT, semi-quantitative OCTA can be considered a more suitable technology for measuring peritubular capillaries and estimating ischemic kidney injury.
Our OCTA flow index measurements showed greater ischemic damage to the glomerular capillaries in the superficial layer than to the peritubular capillaries in the deep layer. These results suggest that deep capillaries exhibit a higher level of recovery from ischemia. A possible explanation for this is that deep capillaries may receive more blood from the arcuate and the interlobular arteries of the medulla43,44. Moreover, immunohistochemical analysis via CD31 staining showed that the ischemic damage was negatively correlated with cortical depth. While previous studies had difficulties measuring the superficial and the deep cortices separately, our study has revealed that superficial capillaries are more susceptible to ischemic damage than deep capillaries using three-dimensional semi-quantitative OCTA.
The renal vasculature is characterized by a weak regenerative process, which causes persistent peritubular vascular rarefaction following significant ischemic injury30. Therefore, assessment of the vasculature at the time of kidney injury can predict long-term renal impairment. OCTA could be applied to kidney transplantion as allograft biopsy performed before and after kidney transplantation, potentially showing an association between peritubular capillary flow and perioperative AKI45. OCTA can safely estimate the peritubular flow of the allograft without an invasive procedure, such as tissue biopsy. Our study confirmed that the 60-min measurement of blood flow change was associated with kidney dysfunction and structural abnormalities, even after 7 weeks. To validate the results of this study, a controlled study of patients with AKI or those who have undergone kidney transplantation is needed to evaluate the predictive ability of OCTA for long-term kidney function.
Our semiquantitative OCTA technique is not free of limitations. One of the key limitations of OCTA-based flow speed measurements is its dependence on optical alignment. OCTA measures the blood flow speed based on optical decorrelation, which roughly represents the mean displacement of erythrocytes relative to the size of the resolution element. Because the illumination spot size increases with the axial distance from the focus, the OCTA flow index is less sensitive at depth positions farther from the objective focal plane. Therefore, to accurately measure fractional blood flow change across the IRI protocol timeline, the optical alignment of the animal with respect to the objective must be carefully controlled. Furthermore, the linearity of the correlative relationship between the OCTA flow index and the absolute blood flow velocity is yet to be thoroughly verified. Multiple flow phantom studies have suggested that a reasonably high degree of linearity can be achieved with accurate arithmetic calibrations27,46,47,48. However, these results must be interpreted with caution because flow index can also depend on the number density of the erythrocytes and the caliber of the vessel. These findings and the upcoming results from in vivo OCTA flow index studies can be adopted for future scan protocols and analysis software updates. Another limitation of our technique is the necessity of surgical procedures due to the limited OCT signal penetration into the tissue. Infrared light suffers from high scattering and absorption in common tissues such as stroma, requiring the imaging sample to be directly accessible through transparent media. OCTA imaging of the human kidney would thus be limited to intraoperative applications such as transplantation. Contrast-enhanced ultrasound is better suited for clinical studies of common kidney diseases since ultrasound echo signal can be detected from multiple centimeters of imaging depth.
In conclusion, this study demonstrated the efficacy of semiquantitative OCTA as a tool for assessing dynamic blood flow changes in murine kidney IRI models. OCTA flow index changes in superficial and deep capillaries showed contrasting results in the 10- and 35-min IRI models. Biochemical and histopathological analyses confirmed that a significant change in the OCTA flow index was indicative of decreased kidney function and vascular damage. These results suggest the potential of OCTA as a method for tracking relative blood flow changes in other mouse models of kidney injury and diseases. Improvements in the measurement protocol and flow index computation can lead to further validation of semiquantitative OCTA in kidney disease models.
Data availability
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Hoste, E. A. J. et al. Global epidemiology and outcomes of acute kidney injury. Nat. Rev. Nephrol. 14, 607–625. https://doi.org/10.1038/s41581-018-0052-0 (2018).
Kellum, J. A., Mehta, R. L., Angus, D. C., Palevsky, P. & Ronco, C. The first international consensus conference on continuous renal replacement therapy. Kidney Int. 62, 1855–1863. https://doi.org/10.1046/j.1523-1755.2002.00613.x (2002).
Mehta, R. L. et al. Acute kidney injury network: Report of an initiative to improve outcomes in acute kidney injury. Crit. Care 11, R31. https://doi.org/10.1186/cc5713 (2007).
Zager, R. A., Johnson, A. C., Andress, D. & Becker, K. Progressive endothelin-1 gene activation initiates chronic/end-stage renal disease following experimental ischemic/reperfusion injury. Kidney Int. 84, 703–712. https://doi.org/10.1038/ki.2013.157 (2013).
Wei, Q. & Dong, Z. Mouse model of ischemic acute kidney injury: Technical notes and tricks. Am. J. Physiol. Renal Physiol. 303, F1487-1494. https://doi.org/10.1152/ajprenal.00352.2012 (2012).
Shiva, N., Sharma, N., Kulkarni, Y. A., Mulay, S. R. & Gaikwad, A. B. Renal ischemia/reperfusion injury: An insight on in vitro and in vivo models. Life Sci. 256, 117860. https://doi.org/10.1016/j.lfs.2020.117860 (2020).
Ortiz, A. et al. Translational value of animal models of kidney failure. Eur. J. Pharmacol. 759, 205–220. https://doi.org/10.1016/j.ejphar.2015.03.026 (2015).
Pickering, J. W. & Endre, Z. H. The definition and detection of acute kidney injury. J. Renal Inj. Prev. 3, 21–25. https://doi.org/10.12861/jrip.2014.08 (2014).
Basile, D. P., Donohoe, D., Roethe, K. & Osborn, J. L. Renal ischemic injury results in permanent damage to peritubular capillaries and influences long-term function. Am. J. Physiol. Renal Physiol. 281, F887-899. https://doi.org/10.1152/ajprenal.2001.281.5.F887 (2001).
Eardley, K. S. et al. The role of capillary density, macrophage infiltration and interstitial scarring in the pathogenesis of human chronic kidney disease. Kidney Int. 74, 495–504. https://doi.org/10.1038/ki.2008.183 (2008).
Tanaka, T. & Nangaku, M. Angiogenesis and hypoxia in the kidney. Nat. Rev. Nephrol. 9, 211–222. https://doi.org/10.1038/nrneph.2013.35 (2013).
Evans, R. G. et al. Haemodynamic influences on kidney oxygenation: Clinical implications of integrative physiology. Clin. Exp. Pharmacol. Physiol. 40, 106–122. https://doi.org/10.1111/1440-1681.12031 (2013).
Fischer, K. et al. High-resolution renal perfusion mapping using contrast-enhanced ultrasonography in ischemia-reperfusion injury monitors changes in renal microperfusion. Kidney Int. 89, 1388–1398. https://doi.org/10.1016/j.kint.2016.02.004 (2016).
Ehling, J. et al. Quantitative micro-computed tomography imaging of vascular dysfunction in progressive kidney diseases. J. Am. Soc. Nephrol. 27, 520–532. https://doi.org/10.1681/ASN.2015020204 (2016).
Kramann, R., Tanaka, M. & Humphreys, B. D. Fluorescence microangiography for quantitative assessment of peritubular capillary changes after AKI in mice. J. Am. Soc. Nephrol. 25, 1924–1931. https://doi.org/10.1681/ASN.2013101121 (2014).
Tewes, S. et al. Functional MRI for characterization of renal perfusion impairment and edema formation due to acute kidney injury in different mouse strains. PLoS ONE 12, 3. https://doi.org/10.1371/journal.pone.0173248 (2017).
Chen, Y., Andrews, P. M., Aguirre, A. D., Schmitt, J. M. & Fujimoto, J. G. High-resolution three-dimensional optical coherence tomography imaging of kidney microanatomy ex vivo. J. Biomed. Opt. 12, 034008. https://doi.org/10.1117/1.2736421 (2007).
Andrews, P. M. et al. High-resolution optical coherence tomography imaging of the living kidney. Lab. Investig. 88, 441–449. https://doi.org/10.1038/labinvest.2008.4 (2008).
Konkel, B. et al. Fully automated analysis of OCT imaging of human kidneys for prediction of post-transplant function. Biomed. Opt. Express 10, 1794–1821. https://doi.org/10.1364/BOE.10.001794 (2019).
Mariampillai, A. et al. Optimized speckle variance OCT imaging of microvasculature. Opt. Lett. 35, 1257–1259. https://doi.org/10.1364/OL.35.001257 (2010).
Kim, D. Y. et al. In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography. Biomed. Opt. Express 2, 1504–1513. https://doi.org/10.1364/BOE.2.001504 (2011).
Shin, I. & Oh, W. Y. Visualization of two-dimensional transverse blood flow direction using optical coherence tomography angiography. J. Biomed. Opt. 25, 12. https://doi.org/10.1117/1.JBO.25.12.126003 (2020).
Venkatachalam, M. A. & Weinberg, J. M. The conundrum of protection from AKI by adenosine in rodent clamp ischemia models. Kidney Int. 84, 16–19. https://doi.org/10.1038/ki.2013.101 (2013).
Park, T., Jang, S. J., Han, M., Ryu, S. & Oh, W. Y. Wide dynamic range high-speed three-dimensional quantitative OCT angiography with a hybrid-beam scan. Opt. Lett. 43, 2237–2240. https://doi.org/10.1364/OL.43.002237 (2018).
Park, J. R., Lee, B., Lee, M. J., Kim, K. & Oh, W. Y. Visualization of three-dimensional microcirculation of rodents’ retina and choroid for studies of critical illness using optical coherence tomography angiography. Sci. Rep. 11, 14302. https://doi.org/10.1038/s41598-021-93631-9 (2021).
Richter, D. et al. Relative retinal flow velocity detection using optical coherence tomography angiography imaging. Biomed. Opt. Express 11, 6710–6720. https://doi.org/10.1364/Boe.408481 (2020).
Tokayer, J., Jia, Y., Dhalla, A. H. & Huang, D. Blood flow velocity quantification using split-spectrum amplitude-decorrelation angiography with optical coherence tomography. Biomed. Opt. Express 4, 1909–1924. https://doi.org/10.1364/Boe.4.001909 (2013).
Basile, D. P. & Yoder, M. C. Renal endothelial dysfunction in acute kidney ischemia reperfusion injury. Cardiovasc. Hematol. Disord.: Drug Targets 14, 3–14. https://doi.org/10.2174/1871529x1401140724093505 (2014).
Babickova, J. et al. Regardless of etiology, progressive renal disease causes ultrastructural and functional alterations of peritubular capillaries. Kidney Int. 91, 70–85. https://doi.org/10.1016/j.kint.2016.07.038 (2017).
Basile, D. P. et al. Impaired endothelial proliferation and mesenchymal transition contribute to vascular rarefaction following acute kidney injury. Am. J. Physiol. Renal Physiol. 300, F721-733. https://doi.org/10.1152/ajprenal.00546.2010 (2011).
Kwon, O., Hong, S. M., Sutton, T. A. & Temm, C. J. Preservation of peritubular capillary endothelial integrity and increasing pericytes may be critical to recovery from postischemic acute kidney injury. Am. J. Physiol.-Renal 295, F351–F359. https://doi.org/10.1152/ajprenal.90276.2008 (2008).
Bonventre, J. V. Mechanisms of ischemic acute renal failure. Kidney Int. 43, 1160–1178. https://doi.org/10.1038/ki.1993.163 (1993).
Yagil, Y., Miyamoto, M. & Jamison, R. L. Inner medullary blood flow in postischemic acute renal failure in the rat. Am. J. Physiol. 256, F456-461. https://doi.org/10.1152/ajprenal.1989.256.3.F456 (1989).
Kang, D. H. et al. Impaired angiogenesis in the aging kidney: Vascular endothelial growth factor and thrombospondin-1 in renal disease. Am. J. Kidney Dis. 37, 601–611. https://doi.org/10.1053/ajkd.2001.22087 (2001).
Kang, D. H. et al. Impaired angiogenesis in the remnant kidney model: I. Potential role of vascular endothelial growth factor and thrombospondin-1. J. Am. Soc. Nephrol. 12, 1434–1447. https://doi.org/10.1681/ASN.V1271434 (2001).
Braunagel, M. et al. dynamic contrast-enhanced computed tomography: A new diagnostic tool to assess renal perfusion after ischemia-reperfusion injury in mice: Correlation of perfusion deficit to histopathologic damage. Invest. Radiol. 51, 316–322. https://doi.org/10.1097/RLI.0000000000000245 (2016).
Advani, A. et al. Fluorescent microangiography is a novel and widely applicable technique for delineating the renal microvasculature. PLoS ONE 6, 117. https://doi.org/10.1371/journal.pone.0024695 (2011).
Hueper, K. et al. Acute kidney injury: Arterial spin labeling to monitor renal perfusion impairment in mice-comparison with histopathologic results and renal function. Radiology 270, 117–124. https://doi.org/10.1148/radiol.13130367 (2014).
Fujimoto, J. G. Optical coherence tomography for ultrahigh resolution in vivo imaging. Nat. Biotechnol. 21, 1361–1367. https://doi.org/10.1038/nbt892 (2003).
Wang, B. et al. Optical coherence tomography and computer-aided diagnosis of a murine model of chronic kidney disease. J. Biomed. Opt. 22, 1–11. https://doi.org/10.1117/1.JBO.22.12.121706 (2017).
Wierwille, J. et al. In vivo, label-free, three-dimensional quantitative imaging of kidney microcirculation using Doppler optical coherence tomography. Lab. Investig. 91, 1596–1604. https://doi.org/10.1038/labinvest.2011.112 (2011).
de Braganca, A. C., Volpini, R. A., Mehrotra, P., Andrade, L. & Basile, D. P. Vitamin D deficiency contributes to vascular damage in sustained ischemic acute kidney injury. Physiol. Rep. 4, 13. https://doi.org/10.14814/phy2.12829 (2016).
Martinoli, C., Bertolotto, M., Pretolesi, F., Crespi, G. & Derchi, L. E. Kidney: Normal anatomy. Eur. Radiol. 9(Suppl 3), S389-393. https://doi.org/10.1007/pl00014081 (1999).
Yoldas, A. & Dayan, M. O. Morphological characteristics of renal artery and kidney in rats. Sci. World J. 2014, 468982. https://doi.org/10.1155/2014/468982 (2014).
Doreille, A. et al. Acute kidney injury, microvascular rarefaction, and estimated glomerular filtration rate in kidney transplant recipients. Clin. J. Am. Soc. Nephrol. 16, 415–426. https://doi.org/10.2215/CJN.07270520 (2021).
Su, J. P. et al. Calibration of optical coherence tomography angiography with a microfluidic chip. J. Biomed. Opt. 21, 1. https://doi.org/10.1117/1.Jbo.21.8.086015 (2016).
Lee, H. J., Samiudin, N. M., Lee, T. G., Doh, I. & Lee, S. W. Retina phantom for the evaluation of optical coherence tomography angiography based on microfluidic channels. Biomed. Opt. Express 10, 5535–5548. https://doi.org/10.1364/Boe.10.005535 (2019).
Choi, W. J. et al. Characterizing relationship between optical microangiography signals and capillary flow using microfluidic channels. Biomed. Opt. Express 7, 2709–2728. https://doi.org/10.1364/Boe.7.002709 (2016).
Percie-du-Sert, N. et al. Reporting animal research: Explanation and elaboration for the ARRIVE guidelines 2.0. PLoS Biol. 18, e3000411. https://doi.org/10.1371/journal.pbio.3000411 (2020).
Funding
This research was supported by a grant from the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI15C0001, HR22C1832), by a young researcher grant from the Korea Society for Transplantation, and by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2021R1I1A3059702, 2021R1I1A3047973, 2021R1I1A1A01040336, 2020R1A2C3009667).
Author information
Authors and Affiliations
Contributions
W.Y.O. and J.H.C. provided study concept and design; W.J.K. and I.H.S. developed the imaging instrument; W.J.K. performed acquisition of data; B.K.L., W.J.K., S.W.C. provided OCTA image processing and flow index calculation; S.H.O. performed statistical analysis; E.J.O., Y.J.K., J.S.A., J.M.Y., J.S.J., J.H.L, and Y.L.K. provided biochemical and immunohistochemical analyses; B.K.L. and S.H.O. performed writing, review, and revision of the paper; W.Y.O. provided technical and material support. All authors read and approved the final paper.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Lee, B., Kang, W., Oh, SH. et al. In vivo imaging of renal microvasculature in a murine ischemia–reperfusion injury model using optical coherence tomography angiography. Sci Rep 13, 6396 (2023). https://doi.org/10.1038/s41598-023-33295-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-33295-9
Comments