Abstract
Segmentation of medical images into different tissue types is essential for many advancements in orthopaedic research; however, manual segmentation techniques can be time- and cost-prohibitive. The purpose of this work was to develop a semi-automatic segmentation algorithm that leverages gradients in spatial intensity to isolate the patella bone from magnetic resonance (MR) images of the knee that does not require a training set. The developed algorithm was validated in a sample of four human participants (in vivo) and three porcine stifle joints (ex vivo) using both magnetic resonance imaging (MRI) and computed tomography (CT). We assessed the repeatability (expressed as mean ± standard deviation) of the semi-automatic segmentation technique on: (1) the same MRI scan twice (Dice similarity coefficient = 0.988 ± 0.002; surface distance = − 0.01 ± 0.001 mm), (2) the scan/re-scan repeatability of the segmentation technique (surface distance = − 0.02 ± 0.03 mm), (3) how the semi-automatic segmentation technique compared to manual MRI segmentation (surface distance = − 0.02 ± 0.08 mm), and (4) how the semi-automatic segmentation technique compared when applied to both MRI and CT images of the same specimens (surface distance = − 0.02 ± 0.06 mm). Mean surface distances perpendicular to the cartilage surface were computed between pairs of patellar bone models. Critically, the semi-automatic segmentation algorithm developed in this work reduced segmentation time by approximately 75%. This method is promising for improving research throughput and potentially for use in generating training data for deep learning algorithms.
Similar content being viewed by others
Introduction
Recent advances in orthopaedic research have relied heavily on medical imaging to investigate in vivo biomechanics1,2,3,4,5,6,7. In particular, previous studies have used magnetic resonance imaging (MRI)-based, three-dimensional (3D) solid modeling techniques to investigate in vivo exercise-induced cartilage deformations8,9,10,11, ligament/tendon elongations12,13, and knee kinematics14,15,16,17, to name a few. These techniques often require researchers to manually segment bones from magnetic resonance (MR) images, which is a laborious process. The automation of bone segmentation has the potential to greatly improve research efficiency and throughput.
Manual segmentation of bones from MR images takes many hours per MR scan. As a result, this process can be cost- and time-prohibitive. Because there is a need for ways to reduce analysis time, some groups have used semi-automated algorithms18,19,20,21,22, specialized MRI pulse sequences with computed tomography (CT)-like bone contrast3,23,24,25,26,27,28,29, statistical shape modeling 4, interactive image segmentation30,31, and deep learning5,6 to improve the efficiency of the segmentation process.
Although MRI is regarded for its soft-tissue visualization, bone signal in most MR images is low as compared to other imaging modalities such as radiography and CT. Most boundary detection algorithms rely on gradients in signal intensity (including Prewitt32, Marr-Hildreth33, Canny34, and Sobel35). Therefore, contrast is a critical feature for segmentation. Specifically, a high contrast (or a large intensity gradient) between bone and the surrounding soft tissue is critical for boundary detection algorithms to be able to isolate bones. Contrast between the bone and cartilage tissue can be quantified using the following Eq.36:
Larger contrast values indicate greater signal differences between these adjacent tissues.
The purpose of this investigation was to develop and validate a semi-automatic boundary detection algorithm to isolate the bones from MR images. We hypothesized that our semi-automatic bone segmentation algorithm would provide a comparable accuracy to both manual segmentation of MR images and the semi-automatic segmentation of CT images, especially near bone regions adjacent to articular cartilage.
Methods
We performed four unique segmentation comparisons to validate our semi-automatic segmentation algorithm (Fig. 1). First, we compared the repeatability of our proposed technique by applying the semi-automatic bone segmentation algorithm to the same MRI scan twice. Second, we assessed how well our semi-automatic bone segmentation algorithm could isolate the patella from two different MRI scans of the same human participants. Third, we evaluated the differences between manual and semi-automatic segmentations of MRI scans of the same human participants. Finally, we compared the semi-automatic segmentations of MRI and CT scans of the same porcine specimens. We imaged porcine specimens to avoid subjecting our human volunteers to the ionizing radiation present during CT imaging. Additional information regarding the in vivo and ex vivo imaging protocols and the segmentation validation methods will be described in more detail below.
Recruitment & in vivo imaging protocol
Four healthy participants (1 male, 3 females; mean age: 28 years, range 23–38 years; mean body mass index (BMI): 22.8 kg/m2, range 21.5–24.2 kg/m2) were recruited and enrolled in this Duke University Institutional Review Board-approved study. All protocols adhered to the approved guidelines, and informed consent was received from all subjects prior to participation in the investigation. Exclusion criteria included any history of lower-extremity injury, surgery, or pain prior to the study. All individuals underwent MR imaging of their dominant knee (defined as the leg with which they would kick a ball37) at 7AM in the Center for Advanced Magnetic Resonance Development within the Duke University Hospital on a 3.0 T MR scanner (TIM Trio; Siemens Healthcare; Malvern, PA) with an 8-channel knee coil (Invivo; Gainesville, FL). Due to previous work comparing bones segmented from CT images and various pulse sequences38, sagittal T1-weighted volume-interpolated breathhold examination with water excitation (T1 VIBE) MR images were acquired (Table 1; Figs. 2A; 3A). Double echo steady-state (DESS) MR images were also acquired for validation purposes, as these images have been used previously for manual segmentation of the patella (Table 1; Figs. 2B, 3A)8,39,40.
Porcine stifle joint preparation & ex vivo imaging protocol
Three intact porcine stifles were obtained from a local abattoir. The joints were stored in a cold room at 4 °C prior to CT imaging in the Duke Cancer Center (Fig. 3B; scanner: Somatom Definition Flash, Siemens Healthcare; Malvern, PA; matrix: 512 × 512 pixels; resolution: 0.3 × 0.3 × 0.6 mm; voltage potential (peak): 120 kVp; tube current: 240 mA). Next, all joints were stored overnight in the 4 °C cold room and then imaged the following day in the Duke Center for Advanced Magnetic Resonance Development using the same T1 VIBE MRI sequence as was used for the human in vivo scans (Table 1; Fig. 3B).
Semi-automatic bone segmentation algorithm
We developed an algorithm to semi-automatically segment the bones from both MR and CT images in MATLAB (The MathWorks, Inc.; Natick, MA). The major steps of this process are outlined in Fig. 4 and will be further explained in the subsequent sections.
A custom MATLAB graphical user interface (GUI) was designed to carry out the segmentation steps. To use this program, T1 VIBE MR images (human and porcine) or sagittal CT images (porcine only) are imported into MATLAB.
The edges in each image are identified using a Canny filter in MATLAB (Fig. 4, Step 1)34. The threshold and standard deviation of the Canny filter are manually selected to maximize the identification of the bone edges, while also limiting noise. The threshold of the Canny filter is defined using a value on a normalized scale from 0–1. All edges stronger than this threshold are preserved. We aimed to keep our threshold as low as possible (to preserve as many edges as possible), while still removing some extraneous edges due to image noise. The selected thresholds were approximately equal for all scans within a given modality (range 0.02–0.07 for MRI, 0.15–0.25 for CT), and the default standard deviation (0.10) was used for all scans. Next, the first and last slices containing the bone of interest are manually identified. The image stack is then manually cropped to isolate the bone of interest (Fig. 4, Step 2). Next, the user selects slice(s) to initialize using a multi-step process (Fig. 4, Step 3):
-
1.
Use drop-down menu to select a slice to initialize.
-
2.
Remove points to break the 8-pixel connectivity (up, down, left, right, and four corners) of Canny edges that are not along the bone boundary.
-
3.
Select edges around the bone boundary to keep.
-
4.
Repeat steps 1–3 until all chosen slices are initialized.
The bone edges from each initialized slice are used as a starting point from which to extract the nearest Canny edge pixels from the image immediately before and after the chosen slice. In this study, the edges were initialized in approximately one out of every five images. Following slice initialization, the user can step through the remaining images one at a time so corrections can be made before proceeding to the next image (Fig. 4, Step 4). After all images are processed, the user can export the coordinates of a 3D point cloud of the designated bone (Fig. 4, Step 5; Fig. 5A).
Validation—Dice similarity coefficient
To determine the repeatability of the semi-automatic segmentation algorithm, we applied this technique to the T1 VIBE MR scans of the human patellae twice per scan. This enabled us to determine the Dice similarity coefficient (DSC) of our segmentation outcomes42:
where \(\left|X\cap Y\right|\) represents the number of elements the sets \(X\) and \(Y\) have in common, and \(\left|X\right|\) and \(\left|Y\right|\) represent the number of elements in the sets \(X\) and \(Y\), respectively. Dice similarity coefficients range from 0 to 1, where 0 indicates no agreement between datasets and 1 indicates full agreement between datasets. We computed the DSC for each MR slice containing patellar bone and then averaged the coefficients across all slices (weighted based on how many pixels were present in each slice) for a given participant to yield an overall mean value per subject. We used Dice similarity coefficients for this comparison since the semi-automated algorithm was repeated twice on the same images.
Validation—surface distance
To further validate the semi-automatic segmentation algorithm, we quantified the mean surface distance between bone models obtained using different segmentation techniques43. Specifically, we focused on analyzing the bone-cartilage interfaces, as this is critical for assessing changes in cartilage thickness8,39,40,44. We first assessed the repeatability of the semi-automatic segmentation of T1 VIBE MR images of human patellae by isolating the patella from: (1) the same image volume twice and (2) repeated T1 VIBE MR scans of the same human patellae acquired approximately 30 min apart on the same day (scan/re-scan repeatability). We also compared bone models generated from: (1) the semi-automatic segmentation of T1 VIBE MR images of human patellae to the manual segmentation of DESS MR images of the same human patellae8,9,10,40,45 and (2) the semi-automatic segmentation of T1 VIBE MR images of porcine patellae to the semi-automatic segmentation of CT images of the same porcine patellae.
To assess the surface distance between pairs of bones, 3D point clouds of the patellae from each of the four human participants (MRI only) and the three porcine specimens (MRI & CT) were generated using the semi-automatic bone segmentation algorithm just described (Fig. 5A). The four human patellae were also manually segmented from each DESS MR image using solid modeling software (Rhinoceros; Robert McNeel and Associates; Seattle, WA) to form 3D point clouds8,39,40,44. Next, the MRI and CT bone point clouds were imported into Geomagic Studio (Geomagic, Inc.; Cary, NC), and the porcine CT point clouds were registered to their respective MRI point clouds using an iterative closest point algorithm to ensure site-specific comparisons of the bone surfaces. A similar registration process was used to align the semi-automatic and manual point clouds of the human patellae, as well as the point clouds generated from the semi-automatic segmentation of the repeated (scan/re-scan) T1 VIBE MR acquisitions in the human participants.
Following registration, the bone models were converted into 3D surface meshes (Fig. 5B). The patellar bone surface directly in contact with patellar cartilage was also extracted from each 3D model (Fig. 5C).
To quantitatively compare the agreement between two bone surface meshes, pairs of surface meshes were evaluated using MATLAB (Fig. 6A,B). While the same process was performed for each pair of surface meshes to quantify the resulting surface distances, we will describe the semi-automatic vs. manual MRI segmentation (T1 VIBE and DESS MR images, respectively) evaluation below.
The semi-automatic segmentation bone model (from T1 VIBE MR images), the manual segmentation bone model (from DESS MR images), and the bone model mesh faces located adjacent to articular cartilage in both models were imported into MATLAB, and the volume centroids of the semi-automatic segmentation bone model were subtracted from all three models to center them about the origin while maintaining their registration. Next, a search algorithm was employed to find all mesh nodes on the manual segmentation bone model located within a 2.5 mm radius of each mesh node on the semi-automatic segmentation bone model. These mesh node coordinates were averaged to yield a single vertex. This yielded a set of matched vertices on the two bone models from which to directly compute the surface distance. Surface distance was defined as the difference in the x-coordinates between the two bone models, as the x-direction is perpendicular to the articular surface of the patella (Fig. 6). Positive surface distances were indicative of regions where the semi-automatic segmentation model was larger than the manual segmentation model, whereas negative surface distances were indicative of regions where the manual segmentation model was larger than the semi-automatic segmentation model.
While we are generating whole-bone models, it is important to note that we are primarily concerned with the agreement between the regions adjacent to the articular surfaces of the bone models since these regions are the areas that will influence cartilage thickness measurements8,39,40,44. Thus, the surface distance calculations were further refined by extracting only bone mesh nodes within the confines of the patellar cartilage model. Specifically, only bone mesh nodes located adjacent to patellar cartilage after a 25% perimeter reduction of the cartilage boundary were considered (Fig. 6C). A similar perimeter reduction was implemented previously to avoid edge effects when quantifying running-induced patellar cartilage strains continuously across the articular surface39. All other surface distance comparisons (repeated segmentations of the same T1 VIBE MRI scans, scan/re-scan repeatability of T1 VIBE MRI segmentations of the same participants, and T1 VIBE MRI vs. CT segmentations of the same porcine specimens) were performed using the same methodology.
Results
A single experienced investigator required approximately 15 min to segment the patella bone from T1 VIBE MR images using the semi-automatic bone segmentation algorithm and approximately 1 h to manually segment the patella bone from the DESS MR images, yielding a time savings of about 75%. The mean (± standard deviation) Dice similarity coefficient and surface distance of our repeated semi-automatic segmentations on the same T1 VIBE MRI scans were 0.988 ± 0.002 and − 0.01 ± 0.001 mm, respectively, indicating a high level of repeatability in isolating the patellar bone from T1 VIBE MR images (Table 2). The negative mean surface distance indicates that the second segmentation of the patella was slightly larger than the first, on average. The semi-automatic T1 VIBE MRI segmentation algorithm yielded a mean (± standard deviation) surface distance of − 0.02 ± 0.08 mm as compared to manual DESS MRI segmentations in the human participants, indicating the DESS MRI segmentations were larger than the semi-automatic MRI segmentations (Table 2). Similarly, when segmenting the same individual’s patella twice (scan/re-scan on the same day), the semi-automatic T1 VIBE MRI segmentation algorithm generated segmentations with a mean surface distance of − 0.02 ± 0.03 mm, indicating the second segmentation was, on average, 0.02 mm larger than the first (Table 2). Finally, the semi-automatic T1 VIBE MRI and CT segmentations of the porcine patellae resulted in a mean surface distance of − 0.02 ± 0.06, indicating the semi-automatic CT segmentations were larger than the semi-automatic T1 VIBE segmentations (Table 2).
Discussion
We have developed a semi-automatic segmentation algorithm to isolate bone from T1 VIBE MR images using gradients in signal intensity. T1 VIBE MR images were chosen for this application because they provide excellent contrast between bone and the adjacent articular cartilage. The algorithm developed is repeatable in its ability to detect patellar bone boundaries from the same MR scan twice and from scan/re-scan acquisitions of the same participants. It also performs favorably in comparison to manual segmentation of MR images, and it produces comparable results between MR and CT images. Furthermore, this semi-automatic segmentation technique generates complete 3D point clouds in a fraction of the time it takes to manually segment the same images. These results indicate that the semi-automatic segmentation algorithm outlined in the present work may be a viable alternative for manual segmentation.
The semi-automatic segmentation algorithm developed in the present work was repeatable in isolating the patellar bone from T1 VIBE MR images. We quantified a mean Dice similarity coefficient of 0.988 and a mean surface distance of − 0.01 mm when comparing the segmentation results from the same MR scan twice. We further demonstrated that segmentations generated from two separate T1 VIBE MR scans of the same participant differed by a mean surface distance of − 0.02 mm. The semi-automatic segmentation algorithm also compared well with manual segmentation of MR images, resulting in a mean surface distance of − 0.02 mm. These values agreed with previous repeatability studies which have demonstrated that manual segmentation of bone cortices and cartilage surfaces from DESS MR images is repeatable to within approximately 0.03 mm44. Additionally, while manual segmentation of the patellar bone from MR images takes about an hour to complete, our semi-automatic segmentation algorithm takes approximately 15 min per patella. Thus, the present findings suggest the semi-automatic segmentation algorithm described can produce comparable results to those obtained via manual segmentation in a fraction of the time.
Furthermore, the semi-automatic segmentation algorithm yielded sub-millimeter mean surface distances when comparing the T1 VIBE MRI and CT bone models (− 0.02 mm). Previous work by Neubert et al.38 demonstrated that the T1 VIBE MR pulse sequence had sub-millimeter absolute differences between T1 VIBE and CT bone models of the femur, tibia, fibula, and patella. While zero echo time (ZTE) MRI mimics the visual appearance of CT images23,24,25,26,27,28,29, a previous study comparing ZTE MRI and CT scans of the glenoid bone showed the scans also differed by sub-millimeter values29. Thus, we believe T1 VIBE-based semi-automatic segmentation is a viable option for bone segmentation from MR images.
While we were able to reduce segmentation time by approximately 75%, further work may seek to reduce this processing time even further. Advances in deep learning algorithms may be one approach. However, deep learning techniques traditionally require relatively large datasets to train the resulting algorithms46,47,48, and the algorithm is limited by the quality of the training data. Since the semi-automatic segmentation technique described in the present work was shown to be comparable to manual segmentation, this method can potentially be used to generate training data for future deep learning algorithms.
Although the present work only validated the semi-automatic segmentation of a relatively small group of patellae, the algorithm described herein can likely be implemented in T1 VIBE images of other bones. This is in part because of the gradient-based segmentation approach used, which may be applicable to new situations. This is potentially a strength of this technique compared to some deep learning techniques that are designed to perform feature identification or pattern recognition in a specific training set49. Image artifacts, due to things such as patient motion or the presence of metallic objects, may alter the efficacy of the present algorithm. Future work will further assess the robustness of the current approach.
The utility of the semi-automatic segmentation algorithm developed in this work is currently limited to bone isolation. As such, manual segmentation of the articular cartilage may be needed to quantify exercise-induced cartilage deformations in vivo15,39,40. In previous studies, bone and cartilage have both been manually segmented from DESS MR images of the knee8,39,44, as the DESS sequence provides an excellent compromise regarding contrast between bone and cartilage as well as between cartilage and synovial fluid. It may be necessary to acquire both T1 VIBE and DESS MR images (for semi-automatic bone segmentation and manual cartilage segmentation, respectively) to assess cartilage deformations in future studies. While acquiring both sequences would increase scan time (mm:ss; T1 VIBE = 4:28, DESS = 9:49, both = 14:17), the significant time savings during data analysis justify this added scan. While this study specifically utilized T1 VIBE MR images for the semi-automatic bone segmentation algorithm, any commercially available pulse sequence with a large contrast may be a viable option for gradient-based segmentation. Future investigations may seek to identify other suitable sequences for semi-automatic bone segmentation that can also be used for manual cartilage segmentation.
In conclusion, we developed a gradient-based semi-automatic bone segmentation algorithm that was repeatable and produced results comparable to both manual MRI segmentation and semi-automatic CT segmentation. We used a T1 VIBE MR pulse sequence, which provided excellent contrast between bone and the adjacent articular cartilage, enabling us to overcome the low cortical bone signal inherent in most MR images23,24. This newly developed algorithm reduced analysis time by approximately 75%. Thus, the semi-automatic bone segmentation algorithm is a viable replacement for manual segmentation that will improve research efficiency.
References
Chang, A. E. et al. Magnetic resonance imaging versus computed tomography in the evaluation of soft tissue tumors of the extremities. Ann. Surg. 205, 340–348. https://doi.org/10.1097/00000658-198704000-00002 (1987).
DeFrate, L. E. Effects of ACL graft placement on in vivo knee function and cartilage thickness distributions. J. Orthop. Res. 35, 1160–1170 (2017).
Reichert, I. L. H. et al. Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences. Magn. Reson. Imaging 23, 611–618. https://doi.org/10.1016/j.mri.2005.02.017 (2005).
Pedoia, V. et al. Three-dimensional MRI-based statistical shape model and application to a cohort of knees with acute ACL injury. Osteoarthr. Cartil. 23, 1695–1703. https://doi.org/10.1016/j.joca.2015.05.027 (2015).
Prasoon, A. et al. in Medical Image Computing and Computer-Assisted Intervention - MICCAI 2013. (eds Kensaku Mori et al.) 246–253 (Springer, 2013).
Zhou, Z., Zhao, G., Kijowski, R. & Liu, F. Deep convolutional neural network for segmentation of knee joint anatomy. Magn. Reason. Med. 80, 2759–2770. https://doi.org/10.1002/mrm.27229 (2018).
Englander, Z. A., Martin, J. T., Ganapathy, P. K., Garrett, W. E. & DeFrate, L. E. Automatic registration of MRI-based joint models to high-speed biplanar radiographs for precise quantification of in vivo anterior cruciate ligament deformation during gait. J. Biomech. https://doi.org/10.1016/j.jbiomech.2018.09.010 (2018).
Owusu-Akyaw, K. A. et al. A comparison of patellofemoral cartilage morphology and deformation in anterior cruciate ligament deficient versus uninjured knees. J. Biomech. 67, 78–83. https://doi.org/10.1016/j.jbiomech.2017.11.019 (2018).
Zhang, H. et al. In vivo assessment of exercise-induced glenohumeral cartilage strain. Orthop. J. Sports Med. 6, 2325967118784518. https://doi.org/10.1177/2325967118784518 (2018).
Wang, H. et al. An MRI-compatible loading device to assess knee joint cartilage deformation: Effect of preloading and inter-test repeatability. J. Biomech. 48, 2934–2940. https://doi.org/10.1016/j.jbiomech.2015.08.006 (2015).
Bingham, J. T. et al. In vivo cartilage contact deformation in the healthy human tibiofemoral joint. Rheumatology (Oxford) 47, 1622–1627. https://doi.org/10.1093/rheumatology/ken345 (2008).
Englander, Z. A. et al. In vivo anterior cruciate ligament deformation during a single-legged jump measured by magnetic resonance imaging and high-speed biplanar radiography. Am. J. Sports Med 47, 3166–3172. https://doi.org/10.1177/0363546519876074 (2019).
Englander, Z. A., Lau, B. C., Wittstein, J. R., Goode, A. P. & DeFrate, L. E. Patellar tendon orientation and strain are predictors of ACL strain in vivo during a single-leg jump. Orthop. J. Sports Med 9, 2325967121991054. https://doi.org/10.1177/2325967121991054 (2021).
Kim, S. Y. et al. Knee kinematics during noncontact anterior cruciate ligament injury as determined from bone bruise location. Am. J. Sports Med. 43, 2515–2521. https://doi.org/10.1177/0363546515594446 (2015).
Owusu-Akyaw, K. A. et al. Determination of the position of the knee at the time of an anterior cruciate ligament rupture for male versus female patients by an analysis of bone bruises. Am. J. Sports Med. 46, 1559–1565. https://doi.org/10.1177/0363546518788316 (2018).
Lansdown, D. A. et al. Reproducibility measurements of three methods for calculating in vivo MR-based knee kinematics. J. Magn. Reason. Imaging 42, 533–538. https://doi.org/10.1002/jmri.24790 (2015).
Patel, V. V. et al. A three-dimensional MRI analysis of knee kinematics. J. Orthop. Res. 22, 283–292. https://doi.org/10.1016/j.orthres.2003.08.015 (2004).
Liukkonen, M. K. et al. Application of a semi-automatic cartilage segmentation method for biomechanical modeling of the knee joint. Comput. Methods Biomech. Biomed. Engin. 20, 1453–1463. https://doi.org/10.1080/10255842.2017.1375477 (2017).
Dam, E. B., Folkesson, J., M.D., P. C. P. & M.D., C. C. in Proc SPIE: Medical Imaging. (SPIE).
Yu, H. J. et al. Comparison of semi-automated and manual segmentation of knee cartilage. Osteoarthr. Cartil. 24, S311. https://doi.org/10.1016/j.joca.2016.01.560 (2016).
Pedoia, V., Li, X., Su, F., Calixto, N. & Majumdar, S. Fully automatic analysis of the knee articular cartilage T1rho relaxation time using voxel-based relaxometry. J. Magn. Reson. Imaging 43, 970–980. https://doi.org/10.1002/jmri.25065 (2016).
Bowers, M. E. et al. Quantitative MR imaging using “LiveWire” to measure tibiofemoral articular cartilage thickness. Osteoarthr. Cartil. 16, 1167–1173. https://doi.org/10.1016/j.joca.2008.03.005 (2008).
Froidevaux, R. et al. Filling the dead-time gap in zero echo time MRI: Principles compared. Magn. Reason. Med. 79, 2036–2045. https://doi.org/10.1002/mrm.26875 (2017).
Larson, P. E. Z. et al. Ultrashort echo time and zero echo time MRI at 7T. Magn. Reson. Mater. Phys., Biol. Med. 29, 359–370. https://doi.org/10.1007/s10334-015-0509-0 (2016).
Breighner, R. E. et al. Technical developments: Zero echo time imaging of the shoulder: Enhanced osseous detail by using MR imaging. Radiology 286, 960–966. https://doi.org/10.1148/radiol.2017170906 (2017).
Delso, G. et al. Clinical evaluation of zero-echo-time mr imaging for the segmentation of the skull. J. Nucl. Med. 56, 417–422 (2015).
Weiger, M. & Pruessmann, K. P. MRI with Zero Echo Time. eMagRes (2007).
Weiger, M., Stampanoni, M. & Pruessmann, K. P. Direct depiction of bone microstructure using MRI with zero echo time. Bone 54, 44–47. https://doi.org/10.1016/j.bone.2013.01.027 (2013).
de Mello, R. A. F. et al. Three-dimensional zero echo time magnetic resonance imaging versus 3-dimensional computed tomography for glenoid bone assessment. Arthroscopy 36, 2391–2400. https://doi.org/10.1016/j.arthro.2020.05.042 (2020).
Grady, L., Schiwietz, T., Aharon, S. & Westermann, R. Random walks for interactive organ segmentation in two and three dimensions: Implementation and validation. Med. Image Comput. Comput. Assist. Interv. 8, 773–780. https://doi.org/10.1007/11566489_95 (2005).
Zhao, F. & Xie, X. in Annals of the BMVA Vol. 2013 1–22 (2013).
Prewitt, J. M. S. Object Enhancement and Extraction 75–149 (Academic Press, 1970).
Marr, D., Hildreth, E. & Brenner, S. Theory of edge detection. Proceedings of the Royal Society of London. Series B. Biological Sciences 207, 187–217, doi:https://doi.org/10.1098/rspb.1980.0020 (1980).
Canny, J. A Computational Approach to Edge Detection. IEEE Transactions on Pattern Analysis and Machine Intelligence PAMI-8, 679–698, doi:https://doi.org/10.1109/TPAMI.1986.4767851 (1986).
Sobel, I. An Isotropic 3x3 Image Gradient Operator. Presentation at Stanford A.I. Project 1968 (2014).
Prince, J. L. & Links, J. M. Medical Imaging Signals and Systems (Pearson Education, 2015).
van Melick, N., Meddeler, B. M., Hoogeboom, T. J., Nijhuis-van der Sanden, M. W. G. & van Cingel, R. E. H. How to determine leg dominance: The agreement between self-reported and observed performance in healthy adults. PLoS ONE 12, e0189876. https://doi.org/10.1371/journal.pone.0189876 (2017).
Neubert, A. et al. Comparison of 3D bone models of the knee joint derived from CT and 3T MR imaging. Eur. J. Radiol. 93, 178–184. https://doi.org/10.1016/j.ejrad.2017.05.042 (2017).
Heckelman, L. N. et al. Dose and recovery response of patellofemoral cartilage deformations to running. Orthop. J. Sports Med. 8, 2325967120967512. https://doi.org/10.1177/2325967120967512 (2020).
Tamayo, K. S., Heckelman, L. N., Spritzer, C. E., DeFrate, L. E. & Collins, A. T. Obesity impacts the mechanical response and biochemical composition of patellofemoral cartilage: An in vivo MRI-based investigation. J. Biomech. 134, 110991. https://doi.org/10.1016/j.jbiomech.2022.110991 (2022).
Cher, W. L. et al. An analysis of changes in in vivo cartilage thickness of the healthy ankle following dynamic activity. J. Biomech. 49, 3026–3030. https://doi.org/10.1016/j.jbiomech.2016.05.030 (2016).
Dice, L. R. Measures of the amount of ecologic association between species. Ecology 26, 297–302. https://doi.org/10.2307/1932409 (1945).
Heimann, T. et al. Comparison and evaluation of methods for liver segmentation from CT datasets. IEEE Trans. Med. Imaging 28, 1251–1265 (2009).
Coleman, J. L. et al. Diurnal variations in articular cartilage thickness and strain in the human knee. J. Biomech. 46, 541–547. https://doi.org/10.1016/j.jbiomech.2012.09.013 (2013).
Bingham, J. T. et al. In vivo cartilage contact deformation in the healthy human tibiofemoral joint. Rheumatology 47, 1622–1627. https://doi.org/10.1093/rheumatology/ken345 (2008).
Raudys, S. J. & Jain, A. K. Small sample size effects in statistical pattern recognition: Recommendations for practitioners. IEEE Trans. Pattern Anal. Mach. Intell. 13, 252–264. https://doi.org/10.1109/34.75512 (1991).
Chan, H.-P., Samala, R. K., Hadjiiski, L. M. & Zhou, C. In Deep Learning in Medical Image Analysis: Challenges and Applications (eds Gobert, L. & Hiroshi, F.) 3–21 (Springer International Publishing, 2020).
Ronneberger, O., Fischer, P. & Brox, T. In Medical Image Computing and Computer-Assisted Intervention—MICCAI 2015 (eds Nassir, N. et al.) 234–241 (Springer International Publishing, 2015).
Erickson, B. J., Korfiatis, P., Akkus, Z. & Kline, T. L. Machine learning for medical imaging. Radiographics 37, 505–515. https://doi.org/10.1148/rg.2017160130 (2017).
Acknowledgements
We would like to thank Jean Shaffer, RT(R)(MR)(CT) and Raven Boykin, RT(R)(MR)(ARRT) from the Duke Center for Advanced Magnetic Resonance Development for their help with MR image acquisition, Carolyn Lowry for her help with CT image acquisition, JaNell Dupree for her help with subject recruitment and with obtaining informed consent, Abigail Holt for her help with the pig joint sample preparation, and Donald T. Kirkendall, PhD, ELS, a contracted medical editor, for reviewing an early version of this manuscript. We would also like to thank the National Institutes of Health (AR074800, AR065527, and AR079184) and the American Orthopaedic Society for Sports Medicine (Steven P. Arnoczky Young Investigator Grant; awarded to Brian D. Lewis, MD) for their support of this project.
Author information
Authors and Affiliations
Contributions
L.N.H.: conception and design of the work, acquisition, analysis and interpretation of data, creation of new software used in the work, and drafted the work. B.J.S.: conception and design of the work, acquisition and interpretation of data, and revised the work. C.E.S.: conception and design of the work, acquisition and interpretation of data, and revised the work. B.D.L.: conception and design of the work, acquisition and interpretation of data, and revised the work. L.E.D.: conception and design of the work, acquisition, analysis and interpretation of data, and revised the work. All authors provided approval of the submitted version of the manuscript and agree to be personally accountable for the work.
Corresponding author
Ethics declarations
Competing interests
Brian D. Lewis is a paid consultant for Stryker, Nanovis, and Zimmer. No other authors have competing interests to disclose.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Heckelman, L.N., Soher, B.J., Spritzer, C.E. et al. Design and validation of a semi-automatic bone segmentation algorithm from MRI to improve research efficiency. Sci Rep 12, 7825 (2022). https://doi.org/10.1038/s41598-022-11785-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-11785-6
This article is cited by
-
Impact of bone and cartilage segmentation from CT and MRI on both bone forearm osteotomy planning
International Journal of Computer Assisted Radiology and Surgery (2023)