Abstract
During application, energetic materials may suffer different temperature environmental stimulation. In order to study the influence of temperature environmental on performance of HNIW/FOX-7 based PBXs, HNIW/FOX-7 based PBX modeling powders and PBX columns were treated by LT (low temperature), HT (high temperature), HLC (high-low temperature cycle) and HLS (high-low temperature shock). Then scanning electron microscope (SEM), infrared spectra (IR), X-ray diffraction (XRD) and differential scanning calorimetry (DSC) were used to study the variation of PBX modeling powders after LT, HT, HLC and HLS treatments; in addition, the mass, size and mechanical properties of PBX columns were characterized after different temperature adaptability treatments as well. The results indicate that the change ratios of mass and size of HNIW/FOX-7 based PBX columns are less than 1%, illustrating that mass and size of PBX columns are at acceptable level after different temperature adaptability treatments. The unevenness degree of the surface of PBX modeling powders followed the order of HLC > HT > LT > HLS, which agrees well with mass loss order. Moreover, IR and XRD results indicated that the molecular structure and crystal form of HNIW and FOX-7 did not change after different temperature adaptability treatments. Additionally, thermal stabilities of PBX modeling powders are decreased after different temperature adaptability treatments, among which HLS has the largest influence on HNIW/FOX-based PBX modeling powders. The compression strengths and elastic moduli of HNIW/FOX-based PBX columns are enhanced after different temperature adaptability treatments, among which the strength of PBX columns after HLC has the maximum increase, indicating that HLC has more significant effect on mechanical property.
Introduction
2,4,6,8,10,12-Hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (HNIW) with cage structure has been widely used as the main explosive in many high energy polymer bonded explosives (PBXs) formulations1,2,3 because of its high energy density, high detonation pressure and high detonation velocity4,5. However, energetic materials with high energy often accompany with high sensitivity and low security. High energy of HNIW based PBXs bring high sensitivity and hazards as well. Nowadays, the sensitivity and vulnerability of high energy explosives are expected to be reduced for enhancing the security of modern weaponry. In order to achieve this goal, using insensitive explosive such as 1,1-diamino-2,2-dinitroethylene (FOX-7) to replace some HNIW to prepare HNIW/FOX-7 based PBXs is a good technique. By adjusting the content of FOX-7, the energy and security of HNIW/FOX-7 based PBXs can be balanced6,7.
Explosives will undergo various temperature environments during their storage, transportation and application. The complex temperature environments may change the mass, size and detonation properties of munitions, which may produce damage and aging inside munitions and exert effects on energy, security and mechanical properties of PBXs, and then produce negative influence on overall functionality of weapon system8. In addition, HNIW have more than one kind of crystalline form, and different crystalline form can be converted to each other at high temperature, and FOX-7 has the same phenomenon. The various temperature environments may change the crystalline form of HNIW and FOX-7, which may result in great variation of properties of HNIW/FOX-7 based PBXs. Therefore, the investigation of temperature adaptability of HNIW/FOX-7 based PBXs is imperative.
In order to study the influence of temperature environmental on performance of HNIW/FOX-7 based PBXs. LT (low temperature), HT (high temperature), HLC (high-low temperature cycle) and HLS (high-low temperature shock) are first used to treat HNIW/FOX-7 based PBX modeling powders and PBX columns. After LT, HT, HLC and HLS treatments, scanning electron microscope (SEM), infrared spectra (IR), X-ray diffraction (XRD) and differential scanning calorimetry (DSC) were used to study the variation of PBX modeling powders. In addition, the mass, size and mechanical properties of PBX columns were characterized after HT, LT, HLC and HLS treatments as well. By comparing the variation SEM, IR, XRD, DSC, mass, size and mechanical properties after different temperature adaptability treatments, the temperature adaptability of HNIW/FOX-7 based PBXs are obtained.
Experimental details
Preparation of HNIW/FOX-7 based PBX samples
Water suspension method9,10 was adopted to prepare HNIW/FOX-7 based PBX modeling powders (47 wt% HNIW, 47 wt% FOX-7, 5 wt% binder system, 0.5 wt% wax, 0.5 wt% graphite). The PBX modeling powders prepared in this study are displayed in Fig. 1a. Then, the modeling powders were further pressed to Φ 20 × 20 mm PBX columns using hydraulic press with the temperature and loading rate of 25 °C and 1 kN s−1 respectively. When the pressure of hydraulic press reached the maximum values (2000 kg cm−2), maintain the maximum pressure for 10 min. Adopting these conditions, the real density of HNIW/FOX-7 based PBX columns could reach 97% of the theoretical maximum density. The PBX columns prepared in this study are displayed in Fig. 1b.
Temperature adaptability treatments
In this study, using constant humidity-temperature chamber (QS-GS100FB), HNIW/FOX-7 based PBXs are treated under LT, HT, HLS and HLC, respectively11,12. Temperature variation settings of LT, HT, HLS and HLC are shown in Fig. 2.
At ambient temperature, 10 g PBX modeling powders and 5 PBX columns were placed into constant humidity-temperature chamber. The temperature of chamber was froze to − 55 °C with a cooling rate of 2 °C min−1 and maintained for 24 h to study the effect of LT on the performance of HNIW/FOX-7 based PBX. The temperature of chamber was heated to 71 °C with a heating rate of 2 °C min−1 and maintained for 48 h to study the effect of HT on the performance of HNIW/FOX-7 based PBX. The temperature of chamber was heated to 71 °C and maintained for 1 h, and then the temperature was froze to − 55 °C and maintained for 1 h. During the test, the heating and cooling rate was controlled at 20 °C min−1. Repeat this cycle three time to study the effect of HLS on the performance of HNIW/FOX-7 based PBX. HNIW/FOX-7 based PBX samples were placed in temperature cycle between − 55 and 71 °C for five cycles to study the effect of HLC on PBX performance. For each cycle, the room temperature (30 °C), low temperature (− 55 °C) and high temperature (71 °C) were maintained for 2, 3 13 h respectively. The heating and cooling rate was controlled at 0.67 °C min−1 during temperature variation process.
Characterizations
Mass and size of PBX columns
After LT, HT, HLS and HLC treatments, the mass and size (diameter and height) of the PBX columns were measured using analytical balance and screw micrometer, respectively. The average variation ratio of mass and size of 5 PBX columns were obtained.
Surface morphology
After LT, HT, HLS and HLC treatments, the surface morphology of PBX modeling powders was obtained by scanning electron microscope (SEM, MIRA3 XM, Tescan Co., Ltd., Brno, Czech Republic).
Infrared spectrum (IR)
After LT, HT, HLS and HLC treatments, IR spectra of PBX modeling powders were recorded using KBr plates on a Nicolet 6700 spectrometer produced by Thermo Fisher Scientific. The wavenumber ranges from 4000 to 400 cm−1, and the tests were carried out at room temperature.
X-ray diffraction (XRD)
After LT, HT, HLS and HLC treatments, X-ray powder diffraction of PBX modeling powders were collected on a Rigaku Ultima IV which was made by Beijing Glory Leader Technology Co., Ltd. The test voltage and electric current were 40 kV and 44 mA, respectively. Scanning angle ranges from 10° to 70° with the scanning speed of 2°/min.
Thermal decomposition
After LT, HT, HLS and HLC treatments, thermal decomposition behavior of PBX modeling powders was measured using differential scanning calorimeter (DSC 200 F3, aluminum crucible with a pin hole cover). The sample with the mass of 0.70 ± 0.01 mg was heated from 50 to 320 °C under nitrogen with a flow rate of 70 mL min−1 with a heating rate of 0.5, 1, 1.5 and 2 °C min−1, respectively. Each sample was analyzed three times.
Flynn–Wall–Ozawa (FWO)13 methods, expressed in Eq. (1), was adopted to calculate the kinetics parameters of the main exothermic decomposition reactions.
where β is the heating rate (°C min−1), Tp is the peak temperature (K), Ea is the apparent activation energy (kJ mol−1), A is the pre-exponential factor (s−1), R is the gas constant valued as 8.314 J mol−1 K−1, α is the conversion degree that was the mass ratio of the reacted substance to the raw, and G(α) is the integral mechanism function.
Adiabatic accelerating thermal decomposition
After LT, HT, HLS and HLC treatments, adiabatic thermal decomposition behavior of PBX modeling powders was studied using accelerating rate calorimeter (ARC, NETZSCH 254) instrument. 110 ± 1 mg samples, spherical hastelloy C vessel, and ‘heat-wait-search’ procedure were used during the measurement. The temperature range of ARC experiment is between 50 and 230 °C. Based on the measured results, the kinetics parameters and mechanism function of PBX modeling powders adiabatic thermal decomposition are obtained.
Mechanical property
After LT, HT, HLS and HLC treatments, according to GJB 772A-9714, the compression strength (σc) and elastic modulus (E) of PBX columns are analyzed using electromechanical universal testing machine (CMT4502). Each PBX column is imposed a quasi-static compression load along the axial with a loading rate of 0.5 mm min−1 until electromechanical universal testing machine reach the maximum load (4.5 kN) or PBX column was damaged. Then E and σc could be calculated by the following two equations,
where ε and σ are strain and stress respectively, A and m are model parameters, P is the compression load and d is the diameter of PBX column.
Results and discussion
Mass and size
Table 1 lists the change ratios of mass and size (height and diameter) of HNIW/FOX-7 based PBX columns. The results illustrate that the change ratios of mass and size (height and diameter) of PBX columns are within 1%. Based on American military standard MIL-STD-175115, the mass and size of PBX columns are still at acceptable level after different temperature adaptability treatments.
After LT, HT, HLS and HLC treatments, the mass of each PBX column is declined, and the variation ratio of the mass of PBX columns after different temperature adaptability treatments follow the order of HLC > HT > LT > HLS, which is associated with the treatment time of temperature adaptability treatments. The variation of the size of PBX columns is more complex than that of mass. It can be concluded that all the diameters are decreased, but the heights are not totally increased or decreased. On the one hand, the mass loss of PBX columns may cause the variation of size. On the other hand, the variation of temperature affects the motion ability of PBX molecules may cause the variation of size as well. The densities of PBX columns are increased after different temperature adaptability treatments, in that the internal stress of PBX columns are released resulting in the decrease of volume. The change ratios of PBX columns after different temperature adaptability treatments are far less than the failure criterion. Therefore, the influence of LT, HT, HLS and HLC on the mass and size of HNIW/FOX-7 based PBX columns can be neglected.
Surface morphology
SEM is used to study the surface morphology of HNIW/FOX-based PBX modeling powders. Figure 3 displays the surface morphology of PBX modeling powders before and after LT, HT, HLS and HLC treatments. After different temperature adaptability treatments, the surface of PBX modeling powders become uneven and emerge many cavities, which is probably caused by the sublimation and gasification of the additives. In addition, it is can be concluded from Fig. 3 that the unevenness degree of the surface of PBX modeling powders follows the order of HLC > HT > LT > HLS, which agrees well with variation ratios of mass loss.
Molecular structure
To investigate whether the structures of HNIW/FOX-based PBX samples have changed after LT, HT, HLS and HLC treatments, the samples are characterized by IR spectroscopy (Fig. 4). It can be concluded from Fig. 4 that after different temperature adaptability treatments all IR spectroscopies are consistent with the untreated sample, indicating that the structures of HNIW/FOX-based PBX samples have not changed.
Crystalline form
HNIW and FOX-7 exist polymorphs16,17,18, and their crystalline form may transform at high temperature. To research whether the crystalline form of HNIW and FOX-7 in HNIW/FOX-7 based PBX has changed after LT, HT, HLS and HLC treatments, the samples are characterized by XRD (Fig. 5). Figure 5 shows that after different temperature adaptability treatments all XRD spectroscopies are consistent with the untreated sample, indicating that the crystal form of HNIW and FOX-7 in HNIW/FOX-7 based PBX samples has not changed.
Mechanical properties
After different temperature adaptability treatments, the compression strengths and elastic moduli of PBX columns are investigated. The stress–strain curves of PBX columns are displayed in Fig. 6, and the calculated compression strengths and elastic moduli are listed in Table 2.
It can be concluded from Table 2 that the compression strengths and elastic moduli of the PBX columns are all increased after HT, LT, HLC and HLS, indicating the enhance of rigidity of PBX columns. The variation of σc and E after LT is relatively small, demonstrating that the effects of low temperature on HNIW/FOX-7 based PBX columns are small. However, the influence of HLC on HNIW/FOX-7 based PBX columns are significant. Although the content of binder system is low in this HNIW/FOX-7 based PBX formulation, it may repair some defects induced by pressing because of its fluidity and spreadability during storage, thus increasing the mechanical properties of the PBX columns. In addition, oxidative crosslinking reaction of binder may occur after temperature adaptability tests under the influence of temperature, which increases the crosslinking point of the polymer network formed after reaction and then raise the crosslinking density, and finally improves compression properties and elastic moduli.
Thermal decomposition
After different temperature adaptability treatments, thermal decomposition performance of the HNIW/FOX-7 based PBX samples are studied by DSC. The measured DSC curves are displayed in Fig. 7. The initial decomposition temperature (To), peak temperatures (Tp) and released heat (ΔH) obtained by DSC measurements are summarized in Table 3.
Table 3 shows that at the same heating rate To and ΔH of PBX samples are decreased after HT, LT, HLC and HLS treatments, illustrating that the thermal insulation effect of binder system and desensitizer on PBX samples may be weakened, resulting in a decrease of PBX samples thermal stability. The decreasing ΔH reveals that the detonation heat may decline after temperature adaptability treatment. The variation of Tp of PBX samples is more complicated, but the variation ratios are lower than 2 °C illustrating that the thermal stabilities of HNIW/FOX-7 based PBXs unchanged after diifernt temperature adaptability treatments.
The kinetics parameter (Ea) of HNIW/FOX-7 based PBX samples are calculated using FWO. The calculated Ea and correlation coefficient (R2) are listed in Table 4. We can find that the R2 are higher than 0.99, illustrating the calculated kinetics parameters are accurate. Generally, materials with higher value of Ea will be more stable. Table 4 shows that the Ea declined after different temperature adaptability treatments, which indicates a probable decline of the stability of HNIW/FOX-7 based PBXs.
Adiabatic accelerating thermal decomposition
The adiabatic decomposition properties of HNIW/FOX-7 based PBX samples are studied by ARC instrument after different temperature adaptability treatments. The measured initial decomposition temperature (To), final decomposition temperature (Tf), adiabatic temperature rise (ΔTad), maximum pressure (Pm) and released heat (Q) are listed in Table 5. The measured ARC curves are displayed in Fig. 8, and the variation of temperature (T), pressure (P), temperature change rate (dT/dt) and pressure change rate (dP/dt) with time (t) during the adiabatic decomposition process of untreated samples are depicted in Fig. 8 as well.
ARC measured results illustrate that the initial decomposition temperature of each sample is around 180 °C demonstrating that temperature adaptability treatments have few influences on the adiabatic decomposition stability of HNIW/FOX-7 based PBXs. In addition, the ΔTad, Pm and Q are decrease after HLC, HLS, HT and LT treatments, but the decrease ratios are low, illustrating that temperature adaptability treatments have few influences on the adiabatic decomposition stability of PBXs as well.
According to ARC measured results, the activation energies (Ea), pre-exponential factors (A) and mechanism functions (f(α)) of HNIW/FOX-7 based PBXs adiabatic decomposition are calculated using mechanism functions method19,20,21,22. The calculated results are summarized in Table 6.
It can be deduced from Table 6 that f(α) is still (1-α)2 after different temperature adaptability treatments, illustrating HLC, HLS, HT and LT treatments wouldn’t change the mechanism functions of HNIW/FOX-7 based PBXs. Ea decreased 17.30 kJ mol−1 (5.95%), 8.78 kJ mol−1 (3.02%), 11.61 kJ mol−1 (4.00%) and 5.75 kJ mol−1 (1.98%), respectively after HLC, HLS, HT and LT treatments. It can be also concluded that the variation ratios of Ea is related to the treatments time of high temperature. After HLC, HLS, HT and LT treatments, the variation ratios of Ea are lower than 20%, which are still in an acceptable level according to GJB 772A-97.
Conclusions
In this study, HNIW/FOX-7 based PBX samples were treated by LT, HT, HLC and HLS. The mass, size, surface morphology, molecular structure, crystalline form, mechanical property and thermal decomposition are characterized to study temperature environmental adaptability of HNIW/FOX-7 based PBXs. The change ratios of mass and size (diameter and height) of HNIW/FOX-7 based PBX columns are lower than 1%, indicating that PBX columns are still at an acceptable level after different temperature adaptability treatments. The surface morphology of PBX samples become uneven and emerge many cavities, which is probably caused by the sublimation and gasification of the additives. The characterization results of IR and XRD demonstrate that the structure and crystal form of HNIW/FOX-7 based PBXs have not changed after temperature adaptability treatments. The compression strengths and elastic moduli of PBX columns are increased after HT, LT, HLC and HLS treatments, indicating the enhance of rigidity of PBX columns. HT, LT, HLC and HLS treatments have few influences on the initial decomposition temperatures, activation energies and mechanism functions of HNIW/FOX-7 based PBXs, indicating that the thermal stabilities of PBXs are almost unchanged.
Above all, after HT, LT, HLC and HLS treatments the performances of HNIW/FOX-7 based PBXs have no significant change, illustrating the temperature environmental adaptabilities of HNIW/FOX-7 based PBXs are adaptable.
References
Li, J. & Brill, T. B. Nanostructured energetic composites of CL-20 and binders synthesized by sol gel methods. Propell. Explos. Pyrot. 31, 61–69 (2006).
Thiboutot, S., Brousseau, P., Ampleman, G., Pantea, D., & Côté, S. Potential use of CL-20 in TNT/ETPE-based melt cast formulations. Propell. Explos. Pyrot. 33, 103–108 (2008).
Samudre, S. S. et al. Studies on an improved plastic bonded explosive (PBX) for shaped charges. Propell. Explos. Pyrot. 34, 145–150 (2009).
Ou, Y. X. Explosives (Beijing Institute of Technology Press, 2014).
Lan, G. C. et al. The study of external growth environments on the crystal morphology of ε-HNIW by molecular dynamics simulation. J. Mater. Sci. 53, 12921–12936 (2018).
Joseph, M. D. et al. Studies on Advanced RDX/TATB based low vulnerable sheet explosives with HTPB binder. Propell. Explos. Pyrot. 34, 326–330 (2009).
Becuwe, A. & Deltlos, A. Low-sensitivity explosive compounds for low vulnerability warheads. Propell. Explos. Pyrot. 18, 1–10 (1993).
Yin, J. T., Yuan, B. H., Shi, W. W., Wang, J. C. & Gao, Y. L. Aging damage and mechanical environment adaptability of pressed HMX-based PBX. Chin. J. Energy Mater. 24, 674–677 (2016).
Elbeih, A., Pachman, J., Zeman, S., Trzcinski, W. A. & Suceska, M. Study of plastic explosives based on attractive cyclic nitramines: Part II. Detonation characteristics of explosives with polyfluorinated binders. Propell. Explos. Pyrot. 38, 238–243 (2013).
Niu, H., Chen, S. S., Shu, Q. H., Li, L. J. & Jin, S. H. Preparation, characterization and thermal risk evaluation of dihydroxylammonium 5, 5-bistetrazole-1, 1-diolate based polymer bonded explosive. J. Hazard. Mater. 338, 208–217 (2017).
Lan, G. C. et al. Investigation into the temperature adaptability of HNIW-based PBXs. Propell. Explos. Pyrot. 44, 327–336 (2019).
Wei, X. W., Zhou, X. Y., Xu, X. Z. & Wang, P. Thermal environment adaptability of HMX based PBX. Chin. J. Explos. Propell. 35, 15–17 (2012).
Osman, A. I. et al. Physicochemical characterization and kinetic modeling concerning combustion of waste berry pomace. ACS Sustain. Chem. Eng. 47, 17573–17586 (2020).
GJB 772A-97. Explosive Test Method, Beijing, China (1997).
MIL-STD-1751. Military standard: Safety and performance tests for qualification of explosives (1982).
Nielsen, A. T. et al. Synthesis of polyazapolycyclic caged polynitramines. Tetrahedron 54, 11793–11812 (1998).
Russell, T. R., Miller, P. J., Piermarini, G. J. & Block, S. High-pressure phase transition in gamma-hexanitrohexaazaisowurtzitane. J. Phys. Chem. 96, 5509–5512 (1992).
Foltz, M. F. Thermal stability of ε-hexanitrohexaazaisowurtzitane in an estane formulation. Propell. Explos. Pyrot. 19, 63–69 (1994).
Lan, G. C. et al. Preparation and performances characterization of HNIW/NTO-based high-energetic low vulnerable polymer-bonded explosive. J. Therm. Anal. Calorim. 139, 3589–3602 (2020).
Zhang, G. Y. et al. Evaluation of thermal hazards and thermo-kinetic parameters of 3-amino-4-amidoximinofurazan by ARC and TG. J. Therm. Anal. Calorim. 126, 1223–1230 (2016).
Townsend, D. I. & Tou, J. C. Thermal hazard evaluation by an accelerating rate calorimeter. Thermochim. Acta 37, 1–30 (1980).
Lan, G. et al. Preparation and thermal properties study of HNIW/FOX-7 based high energy polymer bonded explosive (PBX) with low vulnerability to thermal stimulations. J. Energy. Mater. 38, 83–97 (2020).
Author information
Authors and Affiliations
Contributions
M.Z., G.L. and H.C. wrote the main manuscript text. N.W. and B.Y. prepared experimental data. S.J. and S.C. reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zhou, M., Chen, S., Chao, H. et al. The influence of temperature environmental on performance of HNIW/FOX-7 based PBXs. Sci Rep 12, 4988 (2022). https://doi.org/10.1038/s41598-022-08752-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-08752-6
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.