replying to : S. Pommé and K. Pelczar; Scientific Reports https://doi.org/10.1038/s41598-022-06171-1 (2022).

Introduction


In their comment entitled “Role of ambient humidity underestimated in research on correlation between radioactive decay rates and space weather”, Pommé and Pelczar1 discussed the findings of correlations between measured radioactive decay rates and space weather that we reported recently in this journal2. In the following we would like to make some remarks and clarify several important aspects raised.

Regarding the aspects to clarify, first, it all seems the results of our work were interpreted differently from what we really wanted to express. We make some key clarifications as follows:

  1. (i)

    In reference1, the authors interpreted our results as providing indications for a “causal correlation between space weather and radioactive decay”. In fact, we just provided examples where nuclear decay measurements (and thus not nuclear decay per se) were found to be correlated with space weather indices.

  2. (ii)

    Again in Ref.1, our research is considered “exploratory” but, in our view, we go beyond and provide a detailed correlation analyses based on a wide range of empirical data. We brought up these results to a broader community as it may be relevant for the various findings reported so far about unexpected variations in nuclear decay data measurements.

  3. (iii)

    Pommé and Pelczar regard the nuclear decay’s “correlation with space weather as highly speculative”. In this report, we would like to point out once again that what we have found was a correlation between nuclear decay measurements and space weather when measured inside the MFC. There may be different reasons for that such as measurements (the electronics) may have been distorted by a still-unknown-to-us factor. We certainly need to do more experiments to clarify this issue.

We agree that in normal circumstances (i.e. outside the cage) there is no correlation between space weather and radioactive decay rates measurements. In our first paper3, we investigated the impact of room temperature and wet air density on the nuclear decay (see Fig. 2 in Ref.3) and cable capacitance measurements (see Figs. 10, 13 in Ref.3) and found no obvious correlation. It was then when Scholkmann4 discovered that two space weather variables were often correlated with them, which lead to the further analysis presented in Ref.2,5. Thus, classical environmental factors were considered first to be the possible reasons for the observed fluctuations and afterwards non-classical ones were explored.

Pommé and Pelczar developed a “toy model”6 which shows that the calculated humidity correlates generally well with our measurements of nuclear decay and capacitance.

In order to get deeper insights into the significance of the toy model, we made a systematic analysis of the correlations (see Results in Table 1) considering all the published data in references2,3. In Table 1, the first column refers to the figure number in Ref.3. The next two columns are the statistical analysis between the decay rates and the actual relative humidity.

Table 1 Correlation analyses.

For every pair of data, the following was calculated: (a) the Pearson correlation coefficient, (b) the Spearman correlation coefficient, (c) a Bayes test to consider true or false the hypothesis regarding the correlation values obtained, and (d) a test of statistical significance to consider relevant or non-relevant correlation values (p-value)7. The values in bold inside the highlighted boxes are the cases in which there are significant correlations (or anticorrelations).

It can be noticed that the possible hypothesis about the correlation of the measured data with the relative humidity (RH) is not always true (p < 0.05; B > 1); therefore, it cannot be overestimated and concluded that the RH is the independent variable that completely describes the process. Results in Ref.1 confirm that the RH is a variable that certainly plays a role in the observed correlations but not the only one as shown by our results in Table 1. What really happens could be rationalized by looking into the interplay between RH, geomagnetic activity (GMA) and cosmic-ray activity (CRA)3,8.

As pointed out above, in a new experiment (performed during the months of July and September 2020) we checked again how capacitance changes inside an MFC are related to variations in GMA and CRA9.