Abstract
This study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.
Similar content being viewed by others
Introduction
The introduction of chairside dental computer-aided design and computer-aided manufacturing (CAD/CAM) systems in dental clinics is rapidly increasing1,2,3. Therefore, the use of intraoral scanners for impression acquisition is increasing, and many studies have tried to verify scanning accuracy under various clinical conditions4,5,6. To verify the intraoral scanner, the scanning accuracy is also evaluated, but many previous studies have evaluated the marginal and internal fit of dental prosthesis fabricated using an intraoral scanner for application to dental clinics7,8,9,10. The marginal fit of dental prosthesis considers the clinically acceptable range within 120 µm for reasons such as secondary caries, cement dissolution, and gingival inflammation11,12,13.
In chairside dental CAD/CAM systems, CAM can be divided into milling and additive technologies, and three-dimensional (3D) printing (additive technology) is widely used in the fabrication of interim dental prostheses14,15,16. Previous studies have evaluated 3D trueness to verify the dimensional change of the intaglio surface of the fabricated dental prosthesis17,18,19. Previous studies can be different depending on what is designated as a reference model, such as the manufacturing precision of 3D printers20 and the adjustment of the intaglio surface of the crown in the oral cavity21.
The intraoral scanner has advantages of superior convenience, fast acquisition time of the virtual model, and superior accuracy (based on scanning for single unit) compared with the conventional method22,23,24,25. However, the use of an intraoral scanner for fixed dental prosthesis still requires a solution from a clinical perspective26,27. Since scan distortion occurs from the starting tooth of the intraoral scanning, the possible scan range for fixed dental prosthesis is still limited28. Moreover, factors such as the difference in accuracy according to the type of scanner29,30, inaccuracy of the scan due to the patient’s saliva31, and effect of ambient light in dental clinics on the accuracy32 still require consensus.
In a dental clinical environment, various finish line locations of tooth preparations are often required for fixed dental prosthesis33. However, a previous study verified the difference in the scanning accuracy according to the finish line locations of tooth preparation, and inadequate scanning accuracy was reported for clinical application at the subgingival finish line34. These results indicate that the finish line locations of tooth preparation may affect dental prostheses fabricated using intraoral scanners; however, these studies are still limited.
Therefore, this study aimed to evaluate the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparations of four finish line locations, namely, supragingival, equigingival, subgingival, and subgingival with a cord finish line. The null hypothesis indicates that the marginal and internal fit and intaglio surface trueness of interim crowns fabricated at the four finish line locations did not differ significantly.
Methods
Sample preparation
To prepare a reference model of tooth preparation, the right maxillary first molar was milled under the following conditions (occlusal reduction, 1.5 mm; axial reduction, 1.2 mm; finish line design, chamfer) using a milling unit (Ezis HM; DDS, Seoul, Republic of Korea). To reproduce the oral environment, a lithium disilicate ceramic (IPS e.max CAD; Ivoclar Vivadent AG, Schaan, Liechtenstein) having a transparency similar to that of natural teeth was used. After the crystallization process according to the manufacturer’s recommendations, to reduce the gloss of the surface, the surface was polished using diamond rotary instruments (852.FG.010; Jota AG, Rüthi, Switzerland). The adjacent teeth were manufactured using a 3D printer (Megprinter; Megagen, Daegu, Republic of Korea), transparent silicone (Elite Transparent; Zhermack, Badia Polesine, Italy) was used to reproduce the oral environment, and red pigment (406 red; Shinhan, Seoul, Republic of Korea) was used and replace with semitransparent silicone.
Fabrication of interim crowns and evaluation of intaglio surface trueness
To determine the number of interim crowns (sample size) to be fabricated per finishing line locations, three pilot experiments were performed prior to this study. Based on the results of the pilot experiment, the sample size was determined using power analysis software (G*Power v3.1.9.2; Heinrich-Heine-Universität Düsseldorf, Düsseldorf, Germany) (N = 16; effect size [f] = 0.63; actual power = 99.11%; power = 99%; α = 0.05).
To obtain a reference virtual model of tooth preparation, a precise surface scanning was performed using a contact scanner (DS10; Renishaw plc, Gloucestershire, UK) (Fig. 1). To obtain a high-resolution virtual model, five standard tessellation language (STL) files were acquired through contact scanning and five STL files were merged after optimization alignment by using a 3D mesh software program (Geomagic Design X; 3D Systems, Rock Hill, USA).
The reference model of tooth preparation was adapted to the conditions of each group and fixed to the reference model without movement. The supragingival finishing line was located approximately 0.5 mm above from level of the gingiva, whereas the subgingival finishing line was located approximately 0.5 mm below from the level of the gingiva. The equigingival finishing line was located at the level of the gingiva. Additionally, at the subgingival finishing line, a gingival displacement cord (# 2 Ultrapak; Ultradent, South Jordan, UT, USA) was packed into the gingival sulcus below the finishing line. The depth of the subgingival finishing line was confirmed using a periodontal probe (CP 15 UNC; HU-Friedy, CHI, USA).
To obtain a test virtual model of tooth preparation, an intraoral scanner (i500; MEDIT, Seoul, Republic of Korea) was used to scan a reference model at the supragingival, equigingival, subgingival, and subgingival finish line locations with gingival displacement cords (N = 16 per locations; Fig. 1). All scanning and analysis procedures were performed by an experienced investigator (K.S.).
Sixteen test virtual models acquired per finishing line locations and a reference virtual model were extracted as STL files for interim crown fabrication. In a dental CAD software program (3Shape, Copenhagen, Denmark), the design of interim crowns was performed under the same conditions of a 60-µm cement space. The STL file of the interim crown designed based on the reference virtual model was designated as a CAD reference model (CRM) for the evaluation of intaglio surface trueness (Fig. 1). Interim crowns designed based on the test virtual model were fabricated using a stereolithography 3D printer (ZENITH; Dentis, Daegu, Republic of Korea) with 0° parallel to the vat bottom. In consideration of the printing and repetition accuracy according to the position of the printed object in the vat, the interim crowns produced in four groups were divided into quarters and adjusted to the same position and number when printing once. For the photopolymerization resin for the interim crown, 3D printing resin (For interim crown; Dentis, Daegu, Republic of Korea) was used. For interim crowns after printing, all residual resin was removed according to the manufacturer’s recommendations, and postphotopolymerization was performed using a light-curing unit (CUREDEN; Kwang Myung DAICOM, Seoul, Republic of Korea). All evaluations were completed within 3 h after printing in consideration of the dimensional change according to the time change after printing. The intaglio surface of interim crowns after all posttreatments were scanned using an intraoral scanner (i500; MEDIT, Seoul, Republic of Korea), and the STL file was designated as the CAD test model (CTM) for the evaluation of the intaglio surface trueness (Fig. 1).
Through the evaluation of the intaglio surface trueness, the accuracy of the intaglio surface of interim crowns manufactured according to the finishing line locations was compared (Fig. 1). CRM and CTM alignment and 3D comparison were performed using a 3D inspection software program (Geomagic Control X; 3D Systems, Rock Hill, SC, USA) (Fig. 1). The area of the intaglio surface was segmented based on the margin of CRM. To evaluate the intaglio surface area in detail, it was divided into the marginal, axial, and occlusal regions. CRM and CTM were aligned based on the segmented intaglio surface, and the root mean square was calculated as follows based on all cloud points of the CRM intaglio surface (Eq. 1):
where \({D}_{i}\) represents the gap distance of point \(i\) of CRM and CTM and n is the number of all points evaluated.
Evaluation of the marginal and internal fit
The silicone replica technique was performed to evaluate the marginal and internal fit of interim crowns. After filling the silicone indicator (Aquasil Ultra XLV; Dentsply Detrey GmbH, Konstanz, Germany) in the intaglio surface of the interim crown and accurately positioning it on the tooth preparation, use a jig capable of continuously applying the force (300 gf) on the occlusal surface. Continuous force was applied until the polymerization of the silicone was completed (Fig. 2a). The silicone indicator attached to the intaglio surface of the interim crown was filled with silicone of a different color, and the silicone replica was separated from the interim crown after polymerization.For identical cutting of the silicone replica, an industrial CAD software program (SolidWorks 2014 software; Dassault Systems SolidWorks Corp., Waltham, MA, USA) was used to design a jig based on CRM, and the jig was fabricated using a 3D printer (Megprinter; Megagen, Daegu, Republic of Korea) (Fig. 2b). The jig for cutting the silicone replica is designed to cut the buccolingual and mesiodistal planes based on the center of the interim crown (Fig. 2c). The distance in the silicone replica (Fig. 2d) was measured using an optical microscope (IMS 1080P; SOMETECH, Seoul, Republic of Korea). As for the measurement point of the marginal fit, the marginal gap (MG), which measures the marginal opening, and absolute marginal discrepancy (AMD), which measures the distance between the finishing line and the margin of the prosthesis, were evaluated (Fig. 3). The measurement points of the internal fit are the chamfer gap, which measures the distance between the center of the chamfer curvature of tooth preparation, angle gap, which measures the distance between the center of the angle curvature, and axial gap, which measures the distance between the center of the chamfer and the angle (Fig. 3). The occlusal gap was evaluated by measuring the distance between the center of the occlusal and middle point of the angle (Fig. 3).
Statistical analysis
Statistical analysis was performed using a statistical software program (SPSS Ver 25.0; IBM, Chicago, USA) (α = 0.05). Since all the acquired data had a normal distribution, a parametric statistical analysis was used. Statistical comparison of the marginal and internal fit and intaglio surface trueness per groups was performed using one-way analysis of variance and the Tukey HSD test. The correlation between marginal region trueness and marginal fit (AMD and MG) was evaluated using Pearson correlation analysis.
Results
Significant differences were found in the marginal and internal fit according to finish line locations (P < 0.05; Table 1; Fig. 4). Marginal fit showed the lowest value at the supragingival finish line (AMD: 59.4 ± 12.6 µm, MG: 42.3 ± 9.8 µm) (P < 0.05; Table 1; Fig. 4) and relatively high values at the subgingival finish line (AMD: 112.2 ± 17.8 µm, MG: 78.4 ± 15.8 µm), but no significant difference was found at other finish line locations (P > 0.05; Table 1; Fig. 4). The internal fit showed the lowest value at the supragingival finish line, excluding the axial gap (P < 0.05; Table 1; Fig. 4).
Intaglio surface trueness was significantly different in the marginal region (P = 0.003), and no significant difference was found in the whole, axial, and occlusal regions (P > 0.05; Table 2; Fig. 5). The trueness of the marginal region was highest in the subgingival finish line (50.8 ± 11.9 µm) (P < 0.05), but no significant difference was found at other finish line locations (P > 0.05; Table 2; Fig. 5).
A significant positive correlation was noted between the trueness of the marginal region and marginal fit (AMD and MG) (P < 0.05; Table 3).
Discussion
In this study, interim crowns were fabricated from tooth preparations in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord finish line), and marginal and internal fit and intaglio surface trueness were evaluated. Significant differences in the marginal and internal fit of interim crowns fabricated at four finish line locations were observed, so the null hypothesis was rejected (P < 0.05; Table 1). However, the intaglio surface trueness had a significant difference only in the marginal region, so the null hypothesis was partially rejected (P = 0.003; Table 2). Therefore, these results imply that finish line locations during intraoral scans may affect the marginal and internal fit of interim crowns and the intaglio surface trueness of the marginal region.
In many studies, the marginal fit of dental prosthesis fabricated using an intraoral scanner was evaluated compared with conventional methods for application to dental clinic. Su et al.11 evaluated 3-unit zirconia fixed dental prostheses fabricated using an intraoral scanner (TRIOS2) and reported a better marginal fit (AMD) in the digital group (64 ± 16 µm) than in the conventional group (76 ± 18 µm). Arezoobakhsh et al.12 evaluated 3-unit zirconia frameworks fabricated using intraoral scanners (TRIOS3 and CS3600) and reported better marginal fit (MG) in the digital group (TRIOS3, 60 ± 15 µm; CS3600, 55 ± 13 µm) than in the conventional group (91 ± 40 µm). The equigingival finish line location was applied in study of Su et al.11 and the supragingival finish line location in study of Arezoobakhsh et al.12. The comparison is difficult owing to differences in manufacturing materials and methods used in this study, but all digital groups showed a marginal fit within a mean 120 µm. In this study, the marginal fit of the subgingival finish line (AMD, 112.2 ± 15 µm) was clinically acceptable, but at 95% confidential intervals, the case exceeded 120 µm (Table 1). Of course, a marginal fit exceeding 120 µm in the fabrication of an interim crown that is not a permanent dental prosthesis is not impossible to be applied clinically, but more clinical attention is required in the subgingival finish line.
In previous studies, intaglio surface trueness was evaluated for various purposes17,18,19. Wang et al.20 evaluated the intaglio surface trueness of zirconia crowns fabricated with 3D printing and verified the volumetric stability of the fabricated zirconia crowns. In a previous clinical study, virtual models of crowns before and after intraoral adjustment were superimposed to assess intaglio surface trueness, and the intraoral adjustment of crowns was verified21. In this study, to evaluate the effect of the four finish line locations, crowns fabricated in four finish line locations and crowns designed in a reference tooth preparation were superimposed and the intaglio surface trueness was evaluated (Fig. 1). Only in the marginal region, the intaglio surface trueness was significantly different according to the finish line locations and significantly higher trueness in the subgingival finish line. This means that in the subgingival finish line, there may be an inaccurate reproduction of the marginal region of the interim crowns. Accordingly, the correlation between the trueness of the marginal region and the marginal fit (AMD and MG) was analyzed and a significant positive correlation was found (P < 0.05; Table 3). In light of these results, the result of an inaccurate marginal fit could be seen in the subgingival finish line, since there may be an inaccurate marginal region of interim crowns. Therefore, fabrication of an interim crown by intraoral scan is not recommended for the subgingival finish line.
Nedelcu et al.33 evaluated the effect on the quality of the scanned finish line using intraoral scanners according to the finish line locations and confirmed that it was difficult to clearly distinguish the gingiva from the finish line in the subgingival finish line. In another study, the effect of finish line locations on scan accuracy was evaluated, and the supragingival finish line or a use of gingival displacement cord was recommended for clinically acceptable scan accuracy (< 100 µm)34. However, in this study, the use of the gingival displacement cord at the subgingival finish line did not affect the marginal and internal fit results (P > 0.05; Table 1; Fig. 4). For this reason, previous studies have reported that the accuracy of the supragingival finish line was improved using a gingival displacement cord; however, except for the supragingival finish line (accuracy, 33.6 ± 1.8 µm), the scan accuracy was still inaccurate in the equigingival (accuracy, 127.6 ± 14.7 µm) and subgingival with cord (accuracy, 68.5 ± 7.3 µm)34. In light of these results, consensus is still needed on the effect of scan accuracy on marginal and internal fit through additional studies.
Previous studies have reported the accuracy of intraoral scanners and 3D printers17,18,19,20,21,22,23,24,25. The intraoral scanner (i500; MEDIT) used in the present study for scanning of preparations and intaglio surfaces reported an accuracy of 20–30 µm with respect to a single tooth according to previous study35. In the present study, taking these errors into account, all scans were performed by one experienced investigator (K.S.), and the intraoral scanner was calibrated every time before the experiment. In addition, a 3D printer with SLA technology was used for the fabrication of interim crowns in the present study, and a previous study reported excellent accuracy in 3D printer with SLA technology36. However, to verify the accuracy in the present study, CAD data was designated as a reference and the fabrication precision was further evaluated by comparing it with the scan data of intaglio surfaces. As a result, the mean fabrication precision of 28.1 ± 4.9 µm was shown, and there was no significant difference in fabrication precision among finish line groups (F = 1.179; P = 0.325). However, errors of intraoral scanners and 3D printers may be reflected in the results, and additional studies should be conducted.
This study has several limitations. Although the clinical environment was reproduced in an in vitro environment, there are still differences in the actual teeth and gingiva. Therefore, additional clinical trials should be conducted to verify the effect of finish line locations. Moreover, because the results for various intraoral scanners are insufficient, additional studies have to be conducted to derive more complex results.
Conclusion
Finish line locations influenced the marginal and internal fit of interim crowns. The marginal fit showed the best results in the supragingival finish line, but AMD showed the worst fit in the subgingival finish line. In addition, the finish line locations affected the trueness of the marginal region and showed the worst fabrication reproducibility of the marginal region in the subgingival finish line. This is because the trueness of the marginal region had a positive correlation with the marginal fit, and interim crowns fabricated on the subgingival finish line resulted in inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. Therefore, the use of an intraoral scanner should be decided on the clinical situation and needs.
Data availability
All outcome data are available as summary measures or representative images in the main text or the extended data. The raw datasets generated analyzed during the current study are available from the corresponding author on reasonable request.
References
Zarone, F. et al. Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis. J. Prosthet. Dent. 124, 761–767 (2020).
Rodrigues, S. B., Franken, P., Celeste, R. K., Leitune, V. C. B. & Collares, F. M. CAD/CAM or conventional ceramic materials restorations longevity: A systematic review and meta-analysis. J. Prosthodont. Res. 63, 389–395 (2019).
Coelho, C. et al. Comparison of CAD-CAM and traditional chairside processing of 4-unit interim prostheses with and without cantilevers: Mechanics, fracture behavior, and finite element analysis. J. Prosthet. Dent. 125, 543e1–543e10 (2021).
Winkler, J. & Gkantidis, N. Trueness and precision of intraoral scanners in the maxillary dental arch: An in vivo analysis. Sci. Rep. 10, 1–11 (2020).
Kim, R. J. Y., Benic, G. I. & Park, J. M. Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies. Sci. Rep. 11, 1–9 (2021).
Henninger, E., Vasilakos, G., Halazonetis, D. & Gkantidis, N. The effect of regular dental cast artifacts on the 3D superimposition of serial digital maxillary dental models. Sci. Rep. 9, 1–12 (2019).
Ortega, R., Gonzalo, E., Gomez-Polo, M., Lopez-Suarez, C. & Suarez, M. J. SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns. Dent. Mater. J. 36, 387–393 (2017).
Dauti, R. et al. Micro-CT evaluation of marginal and internal fit of cemented polymer infiltrated ceramic network material crowns manufactured after conventional and digital impressions. J. Prosthodont. Res. 63, 40–46 (2019).
Yildirim, B. & Paken, G. Evaluation of the marginal and internal fit of implant-supported metal copings fabricated with 3 different techniques: An in vitro study. J. Prosthodont. 28, 315–320 (2019).
Keshvad, A. et al. Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques. J. Prosthodont. 20, 535–540 (2011).
Su, T. S. & Sun, J. Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression. J. Prosthet. Dent. 116, 362–367 (2016).
Arezoobakhsh, A., Shayegh, S. S., Ghomi, A. J. & Hakimaneh, S. M. R. Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans. J. Prosthet. Dent. 123, 105–112 (2020).
Farjood, E., Vojdani, M., Torabi, K. & Khaledi, A. A. R. Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing. J. Prosthet. Dent. 117, 164–170 (2017).
Peng, C. C., Chung, K. H. & Ramos, V. Jr. Assessment of the adaptation of interim crowns using different measurement techniques. J. Prosthodont. 29, 87–93 (2020).
Alharbi, N., Alharbi, S., Cuijpers, V. M., Osman, R. B. & Wismeijer, D. Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs. J. Prosthodont. Res. 62, 218–226 (2018).
Mai, H. N., Lee, K. B. & Lee, D. H. Fit of interim crowns fabricated using photopolymer-jetting 3D printing. J. Prosthet. Dent. 118, 208–215 (2017).
Li, R. et al. Three-dimensional trueness and margin quality of monolithic zirconia restorations fabricated by additive 3D gel deposition. J. Prosthodont. Res. 64, 478–484 (2020).
Hwang, H. J., Lee, S. J., Park, E. J. & Yoon, H. I. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing. J. Prosthet. Dent. 121, 110–117 (2019).
Al Hamad, K. Q., Al-Rashdan, R. B., Al-Rashdan, B. A. & Baba, N. Z. Effect of milling protocols on trueness and precision of ceramic crowns. J. Prosthodont. 30, 171–176 (2021).
Wang, W., Yu, H., Liu, Y., Jiang, X. & Gao, B. Trueness analysis of zirconia crowns fabricated with 3-dimensional printing. J. Prosthet. Dent. 121, 285–291 (2019).
Son, K., Yu, B. Y., Lee, J. H., Son, Y. T. & Lee, K. B. Comparison of intaglio surface adjustment in the oral cavity for lithium disilicate crowns fabricated using different scanners. J. Prosthodont. 30, 276–281 (2021).
Gan, N., Ruan, Y., Sun, J., Xiong, Y. & Jiao, T. Comparison of adaptation between the major connectors fabricated from intraoral digital impressions and extraoral digital impressions. Sci. Rep. 8, 1–9 (2018).
Fukazawa, S., Odaira, C. & Kondo, H. Investigation of accuracy and reproducibility of abutment position by intraoral scanners. J. Prosthodont. Res. 61, 450–459 (2017).
Oh, K. C., Park, J. M. & Moon, H. S. Effects of scanning strategy and scanner type on the accuracy of intraoral scans: A new approach for assessing the accuracy of scanned data. J. Prosthodont. 29, 518–523 (2020).
Róth, I. et al. Learning curve of digital intraoral scanning—An in vivo study. BMC Oral Health 20, 1–7 (2020).
Koseoglu, M., Kahramanoglu, E., & Akin, H. Evaluating the effect of ambient and scanning lights on the trueness of the intraoral scanner. J. Prosthodont. https://doi.org/10.1111/jopr.13341 (2021).
Son, K. & Lee, K. B. Effect of tooth types on the accuracy of dental 3d scanners: An in vitro study. Mater. 13, 1744 (2020).
Park, G. H., Son, K. & Lee, K. B. Feasibility of using an intraoral scanner for a complete-arch digital scan. J. Prosthet. Dent. 121, 803–810 (2019).
Treesh, J. C. et al. Complete-arch accuracy of intraoral scanners. J. Prosthet. Dent. 120, 382–388 (2018).
Nedelcu, R. G. & Persson, A. S. Scanning accuracy and precision in 4 intraoral scanners: An in vitro comparison based on 3-dimensional analysis. J. Prosthet. Dent. 112, 1461–1471 (2014).
Chen, Y. et al. Influence of liquid on the tooth surface on the accuracy of intraoral scanners: An in vitro study. J. Prosthodont. https://doi.org/10.1111/jopr.13358 (2021).
Revilla-León, M. et al. Intraoral digital scans—Part 1: Influence of ambient scanning light conditions on the accuracy (trueness and precision) of different intraoral scanners. J. Prosthet. Dent. 124, 372–378 (2020).
Nedelcu, R., Olsson, P., Nyström, I. & Thor, A. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: An in vitro descriptive comparison. BMC Oral Health 18, 27 (2018).
Son, K. & Lee, K. B. Effect of finish line locations of tooth preparation on the accuracy of intraoral scanners. Int. J. Comput. Dent. 24, 29–40 (2021).
Dutton, E. et al. The effect different substrates have on the trueness and precision of eight different intraoral scanners. J. Esthet. Restor. Dent. 32, 204–218 (2020).
Khaledi, A. A. et al. Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: Milling, stereolithography, and 3D wax printer. J. Prosthet. Dent. 124, 81–86 (2020).
Acknowledgements
The authors thank the researchers at the Advanced Dental Device Development Institute, Kyungpook National University for their time and contributions to the study. This research was conducted under the industrial infrastructure program of laser industry support, which is funded by the Ministry of Trade, Industry & Energy (MOTIE, Korea, N0000598).
Author information
Authors and Affiliations
Contributions
K.S. contributed to conception and design, data acquisition, analysis, and writing-original draft; Y.-T.S. contributed to data acquisition and interpretation; J.-M.L. contributed to data acquisition and interpretation; K.-B.L. contributed to supervision and project administration. All authors gave final approval and agree to be accountable for all aspects of the work.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Son, K., Son, YT., Lee, JM. et al. Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations. Sci Rep 11, 13947 (2021). https://doi.org/10.1038/s41598-021-93455-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-93455-7
This article is cited by
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.