Introduction

Hospital-acquired infections (HAI) can be defined as the infections acquired by a patient who was admitted to a hospital or other healthcare facility that were not present (or incubating) at the moment of admission. HAI represent a significant healthcare problem with an estimated total of 8.9 million cases occurring in the EU during 2016–2017 in acute care hospitals and long-term care facilities1. The prevalence of HAI has been estimated to vary between 4.4% in primary care hospitals to 7.1% in tertiary care hospitals, reaching 19.2% in intensive care units1. In the EU in 2015, around 25% of HAI were caused by antibiotic-resistant bacteria with an estimated annual mortality of 33,000 patients2.

HAI can be caused by pathogens coming from other patients, the staff or the hospital environment. The different high-touch surfaces such as door handles, tables, nurse-call buttons or bed rails can be contaminated by potential pathogens which are able to form biofilms and survive on the surfaces for a long time3. It has been demonstrated that some antibiotic-resistant bacteria, as methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE), are able to survive for weeks on different surfaces4. Recent evidence confirmed that the previous occupation of rooms by patients infected or colonized with MRSA, VRE or other antibiotic-resistant pathogens increased the risk of new patients to be colonized with those pathogens5. Consequently, appropriate protocols to clean and disinfect hospital surfaces are crucial to prevent HAI of which manual cleaning with disinfectants is the most commonly used. However, chemical cleaners used to disinfect surfaces are not exempt from certain degree of toxicity, can be incorrectly applied and have to be used at their effective concentration. Moreover, once applied on surfaces, disinfectant activity disappears and the objects could contaminate again within minutes6.

Modified surfaces can lead to a decrease in the bacterial attachment and biofilm production, which has raised interest in the research on polymeric films with structured surfaces with intrinsic properties or on films with embedded antibacterial agents. There is evidence that different polymers with specific micro- and nano-topographies can inhibit the attachment, growth and spread of microorganisms7,8,9. Furthermore, different polymeric materials treated with silver, copper, polycations, triclosan, bacteriophages or light activated biotoxic radicals have been developed10.

To assess the activity of films with antibacterial behaviour, appropriate evaluation tests are needed. The ISO 22196 standard (Japanese test method JIS Z 2801) is used for the measurement of antibacterial activity on plastic surfaces11. However, some studies have described this test as inappropriate, since the temperature of incubation (35 ± 1 °C) and the relative humidity (higher than 90%) do not reflect real conditions12. Thus, alternative and more realistic methods for the in vitro study of antibacterial activity of plastic surfaces have been described7,13.

In this study, the main objective was to compare the performance of different described tests to measure the antibacterial activity of plastic surfaces. To achieve this goal, the antibacterial activity of a three-layer polypropylene (PP) polymer matrix with two different nano- and micro-structures was evaluated with previously described tests (the ISO 22916 standard11, the immersion method7, and the touch-transfer inoculation method7). Moreover, a new methodology based on the protocols described by Mann et al.7 was designed for this study, called the “swab inoculation method”.

Methods

Preparation of film specimens

The test film comprised a smooth three-layer film made of two 25 µm external PP layers (SABIC grade, PP-2 SABIC PP 520L), and a 50 µm central layer of an olefin based thermoplastic elastomer (ZELAS 7025) produced at Propagroup (Torino, Italy). The inner layer was ready to function as a reservoir for the progressive release of encapsulated essential oils or other compounds with antibacterial activity. In this work, only structured films without antibacterial compounds were tested to exclusively check the antibacterial activity of patterned surfaces.

A topography containing ordered micro- and nano-patterns was imprinted on the surface of the PP film by means of nanoimprint lithography. The topography consisted on 5 μm cylindrical micropillars with nanospikes covering the bottom, among micropillars (Fig. 1). A nickel stamp was used as a stamp, which was copied from an original silicon master14. Non-structured smooth films were used in the different tests as control.

Figure 1
figure 1

Topography of the structured films: 5 μm diameter micropillars fabricated on a PP substrate (left; 10 µm scale), where the roughness they show at the bottom corresponded to the presence of nanospikes (right; 1 µm scale).

Bacterial strains and growth conditions

The bacteria used in this study were the Gram-negative Escherichia coli (ATCC 25922) and the Gram-positive Staphylococcus aureus (ATCC 25923). Bacteria from the frozen stock culture were transferred to Trypcase Soy Agar (TSA) supplemented with 5% sheep blood plates (TSA, bioMèrieux, France) and incubated at 37 °C for 18–24 h. Bacteria were transferred to 50 mL of sterile Tryptic Soy Broth (TSB) medium and grown at 37 °C, 80 rpm, 18–24 h. Prior to inoculation, strains were subcultured into fresh TSB at 1:50 and incubated for 2 h at 37 °C, 80 rpm. Bacteria were collected by centrifugation (2000 rpm, 10 min) and resuspended in phosphate buffered saline (PBS). The number of bacteria was spectrophotometrically adjusted to O.D.600 nm = 0.5 (equivalent to 1.5 × 108 CFUs/mL) and confirmed by culturing 1/10 serial dilutions of the initial suspension.

The patterned films evaluated in this study were highly hydrophobic so it was difficult to homogeneously spread the aqueous inoculum over the surface (Fig. 2 left). In order to resolve this problem, the bacterial inocula were applied using glycerol to reduce the surface tension of the suspension (Fig. 2 right). Three different final concentrations of glycerol were tested (5%, 10% and 40%). For all experiments it was decided to use the lowest concentration of glycerol (5%) as the distribution of the inoculum was as homogenous as with higher concentrations of glycerol (40%) and more homogenous than with PBS alone and the bacterial recovery was similar at all glycerol concentrations tested (data not shown).

Figure 2
figure 2

Hydrophobic behaviour of the PP film showing a high contact angle (97.8° ± 1.1°) of a drop of PBS (left) and a lower contact angle (86.4° ± 1.1°) of a drop of PBS with 5% glycerol (right) (p < 0.001) measured with a SURFTENS universal goniometer. The white rectangle inside the droplets is the reflections of the diffuse light illuminating the drop to obtain the image with a sharper border.

Antibacterial activity tests

  1. (a)

    ISO 22196 standard method

    The ISO 22196 was performed with slight modifications11. Pieces of 50 mm × 50 mm of the film and of non-structured smooth control films were placed in sterile 90 mm Petri dishes. Serial dilutions of the bacteria inoculum were made to reach a final bacterial concentration of 6 × 105 CFUs/mL of which 400 µL were pipetted onto the test surfaces. Bacterial inoculum was then covered with 40 mm × 40 mm piece of STOMACHER bag in order to homogeneously spread the inoculum over the surface. The specimens were incubated for 24 h at 35 °C and a relative humidity > 90%. To recover the bacteria from the surfaces of the plastic samples, 10 mL of Soybean Casein Lecithin Polysorbate (SCDLP) broth was added to the Petri dish. The SCDLP was collected and released at least four times to ensure that the specimens were completely washed. Then, tenfold serial dilutions of the SCDLP were made in PBS and 50 µL of 10–4, 10–5, 10–6 and 10–7 dilutions were cultured on TSA with 5% sheep blood plates. Plates were incubated at 35 °C for 24 h. The number of colonies per plate was recorded and used to determine the number of viable bacteria per cm2 in accordance with the equation:

    $$N = \left( {100 \times C \times D \times V} \right)/A$$

    where C is the average of CFU count, D is the dilution factor, V is the volume in mL of SCDLP and A is the surface (cm2) of the film.

  2. (b)

    Immersion inoculation assay

    Immersion inoculation assay7 evaluated the attachment and survival of the bacteria directly from the surface of the film. Serial dilutions of the bacteria inoculum were made in PBS to reach a bacterial concentration of 6 × 104 CFUs/mL. Film samples (50 mm × 50 mm) were placed in a 90 mm sterile Petri dish and were completely covered with 20 mL of bacterial inoculum for 1 h at room temperature without shaking. The films were then washed 3 times with 20 mL of PBS for 10 s while rotating at 80 rpm and allowed to dry under ambient conditions for 1 h before being sampled.

  3. (c)

    Touch-transfer inoculation assay

    The Touch-transfer inoculation assay was described by Mann et al.7 and assessed the attachment (transference) and survival of the bacteria (persistence) directly on the surface of the film. In this study, the protocol described by Mann et al.7 was used with minor changes. Briefly, serial dilutions of the bacteria inoculum were made in PBS to reach a bacterial concentration of 6 × 104 CFUs/mL (Fig. 3a). This inoculum was experimentally established on 25 mm × 50 mm smooth control films, because it provided an adequate number of CFUs (around 50 well defined CFUs per film using the agar contact method described in the Sampling and colony counting section) to have statistical difference between surfaces with or without antibacterial activity. As described above, one of the modifications made was the addition of glycerol 5% to the bacterial suspension to reduce the surface tension of the PBS on the film, which allowed a more homogeneous distribution of the bacterial suspension on the surface. A 25 mm × 50 mm control film and patterned film specimens were placed together in a sterile 90 mm Petri dish (Fig. 3b). A sterile velveteen cloth was placed on a replica plating tool (Bel-Art Products, Wayne, NJ) (Fig. 3c) and immersed into 10 mL of the bacterial suspension by direct contact during 1 min (Fig. 3d). The excess of bacterial suspension was eliminated by placing the inoculated cloth for 10 s onto another dry sterile velveteen cloth (Fig. 3e). The inoculated velveteen cloth was pressed for 10 s contact time against the surface of the films (Fig. 3f). The surfaces were allowed to dry under ambient conditions (± 24 °C and humidity of ± 30%) for 0 min (transference) or 90 min (persistence) (Fig. 3g). Films were sampled (Fig. 3h) and colonies counted as described in the Sampling and colony counting section (Fig. 3i).

    Figure 3
    figure 3

    Schematic representation of the touch-transfer assay.

  4. (d)

    Swab inoculation assay

    The Swab inoculation assay or Swab assay was designed for this study based in the Touch-transfer inoculation assay in order to obtain more reproducible results. This assay also assessed the attachment and survival of the bacteria on the surface of the film. Serial dilutions of the bacteria inoculum were made in PBS supplemented with glycerol 5% to reach a bacterial concentration of 6 × 104 CFUs/mL (Fig. 4a). Fifty microliters of the bacterial suspension were pipetted on the control and patterned films (25 mm × 50 mm) (Fig. 4b) and spread homogenously by rolling a cotton swab over their surface (Fig. 4c). Films were allowed to dry under ambient conditions (± 24 °C and humidity of ± 35%) for 0 min (transference) or 90 min (persistence) (Fig. 4d) before being sampled (Fig. 4e) and colonies counted (Fig. 4f).

    Figure 4
    figure 4

    Schematic representation of the swab assay.

Sampling and colony counting

To quantify the bacteria on the film surface, the agar contact method was used15 to directly transfer the bacteria of the surface of the films to the culture agar plates (COUNT-TACT plates, bioMèrieux, France). Contact plates were pressed for 10 s onto the surfaces of the films with the help of a COUNT-TACT applicator (bioMèrieux, France) that applies a uniform pressure of 0.5 kg on the surface of the contact agar plate. After inoculation, plates were incubated for 18–24 h at 35 °C. Colony counting was performed manually. The complete removal of bacteria form film surfaces was confirmed by optical microscopy after simple methylene blue staining and by thoroughly rubbing the surfaces of films with a swab and culturing them, without observing any bacterial growth.

Data reporting and statistical analysis

For each assay, three samples of each plastic film with micro- and nano-structures and three smooth control samples were analysed. Each assay was performed twice. Mean colony counts and standard deviation (SD) were calculated for each film and controls. Results were expressed as logarithm of CFUs/cm2. A single student’s t-test was used to compare the bacterial counts between the patterned and the smooth surfaces. A p-value lower than 0.05 was considered statistically significant. Statistical analyses were performed using Prism GraphPad version 8 software (GraphPad Software, Inc., La Jolla, CA, USA).

Results

The antibacterial activity of the micro- and nano-patterned film against E. coli and S. aureus was assessed by the four described methodologies. In the ISO 22196 assay (Fig. 5), the inoculum had to be spread over the surface of the film with the help of a piece of Stomacher bag. During the performance of the assay, it was observed that due to the hydrophobicity of the film it was difficult to spread the inoculum homogenously over the surface leaving some parts of the film not in contact with the bacterial inoculum. As shown on Fig. 4, no reduction in the bacterial count was observed on the patterned film compared to the smooth control film after 24 h of incubation in any of the assays.

Figure 5
figure 5

ISO 22196 standard. Antibacterial activity of a patterned film on E. coli and S. aureus according to the ISO 22196 standard. Bars represent average bacterial counts expressed as Log(CFU/cm2). ns no significant.

The bacterial attachment to the film was also tested by the immersion assay (Fig. 6). The bacterial counts in the patterned film were not statistically lower than the counts on the control film (p > 0.05 for all assays). However, close to zero attachment of bacteria was observed in the control film with this method (Fig. 6: 23 CFU/cm2) as compared to the touch-transfer and swab-transfer inoculation assays (Fig. 7: 105 CFU/cm2).

Figure 6
figure 6

Immersion assay. Anti-attachment activity of a PP patterned film on E. coli and S. aureus studied by the immersion method. Bars represent average bacterial counts expressed as log (CFU/cm2). ns no significant.

Figure 7
figure 7

Touch-transfer (TT) and Swab assays. Attachment and survival of E. coli and S. aureus on a PP patterned film after 0 and 90 min of incubation, respectively, according to the Touch-transfer and Swab assays. Bars represent average bacterial counts expressed as log (CFU/cm2). ns no significant. *p < 0.05. **p < 0.01.

The Touch-transfer and the Swab inoculation assays (Fig. 7) were performed to test the attachment of bacteria (after 0 min of incubation) to the surface and the antibacterial activity (after 90 min of incubation) of the film against S. aureus and E. coli.

The bacteria inoculum was prepared with and without glycerol 5% in order to spread the inoculum more homogenously over the film. The addition of glycerol 5% showed a better spread of the inoculum over the surface without altering the growth of the bacteria as observed in the control film (data not shown). The bacterial count on control films was very uniform (4.5–5 CFU/cm2, standard deviation < 0.15 in all cases).

As depicted on Fig. 7, at time-point 0, on the patterned film, a lower bacterial attachment for E. coli and S. aureus was observed by both methods (p < 0.05). The antibacterial activity of the film was also studied after 90 min of contact between the bacteria and the surface of the film, either the inoculum was transferred with the help of a velveteen cloth or with a swab. A statistical reduction in bacterial counts was observed in both bacterial species with both methods except for S. aureus in the touch-transfer assay, in which the reduction did not reach the statistical significance (p = 0.052; Fig. 7).

A comparison of the conditions and advantages and disadvantages of the four methods used in this study is showed in Table 1.

Table 1 Comparison of the conditions and advantages/disadvantages of the four methods studied to test the antimicrobial activity of highly hydrophobic surfaces.

Discussion

Frequently-touched environmental surfaces play an important role as reservoirs and sources of microorganism transmission10. Microbial pathogens are able to survive on the surfaces for long time, and could be transferred and cause HAI in patients admitted to hospitals12. There are different current strategies to prevent the contamination of surfaces and therefore, reduce the possibility of patients’ infection. Manual cleaning with antibacterial products is the disinfection method most commonly used in healthcare settings. Automated cleaning using UV light is another method that can be employed to provide not only surface but also environmental disinfection in critical areas of the hospitals6. More recently, the use of antimicrobial surfaces to permanently prevent their role as reservoir for potential pathogens has emerged as a potential solution7,8. Among them, antiadhesive surfaces, contact-active surfaces, biocide-releasing surfaces or modified topographies have been developed8. It has been demonstrated that the micro-patterned surface of films reduces bacterial contamination7. To evaluate the antibacterial activity of patterned films different tests can be used and depending on the methodology used, the antibacterial activity results could vary7,16,17,18.

One of the most commonly applied tests for the measurement of antibacterial activity on surfaces is the ISO 22196 standard, which evaluates the antibacterial activity of plastic surfaces after the incubation of a known bacterial inoculum for 24 h11. However, the usefulness of the ISO 22196 assay for the evaluation of new antibacterial surfaces is unclear as it showed discrepancies with other methods mainly due to the unrealistic way of transferring bacteria to the plastic surfaces, the high inoculum used and the amount of culture medium left in the liquid layer for 24 h for the diffusion of chemical antibacterial products present in plastics13,18. In a study carried out in 8 different research facilities, differences between laboratories were found using the ISO 22196 standard method, mainly for materials with intermediate antibacterial activity17. Incubation time, initial bacterial concentration, bacterial phase of growth and nutrient concentration were critical factors that influenced the results of antibacterial testing. It has been demonstrated that the incubation conditions used in the ISO 22196 can influence the antibacterial activity of some materials12,19. Differences in the activity of silver-ion containing materials were observed when they were tested using the ISO 22196 conditions (high activity at > 90% relative humidity) instead of more realistic conditions of 22% relative humidity (nearly no activity)19. However, humidity was not critical for the activity of copper and copper alloys.

In our study, no antibacterial activity of the film was shown by the ISO 22196 method. The conditions used in the ISO 22196 (high inoculum, bacterial culture media and incubation temperature of 35 °C, and relative humidity of 90%) were far away from the conditions observed in the real setting. By using the more realistic touch-transfer and swab inoculation assays the antibacterial activity of patterned film could be demonstrated. The activity of the film was more related to the anti-attachment activity, probably due to its high hydrophobicity, than to a direct killing of the bacteria. The ISO 22196 test is adequate for testing films releasing antibacterial active compounds but not for films whose antibacterial activity is based in their surface structure.

The touch-transfer and the swab inoculation assays, both studying transference and persistence events, were highly reproducible supported by the low standard deviation observed in the bacterial counts of the control film. The swab assay was designed in our laboratory taking the protocol of Mann et al.7 as a reference but trying to better standardize the inoculum applied to the film by controlling the amount of bacteria placed on it. Another modification was the addition of glycerol 5% to the inoculum to obtain a better distribution of the bacterial suspension all over the surface of the highly hydrophobic film. Glycerol was selected because it is commonly used as preservative in bacterial freezing media and experimentally it greatly improved the distribution of the inoculum that otherwise, using only PBS, would have been impossible to achieve. Glycerol was innocuous for the bacteria and reduced the surface tension of the bacterial suspension thus achieving a homogeneous distribution of the bacteria on the film. After inoculating the film surfaces, bacteria were left for 90 min at room temperature (24 °C) and humidity (31%) before taking samples with the contact plates better mimicking the conditions found in a hospital ward. In fact, the experiment was performed in the laboratory of a hospital which better represented the environment of the patients’ rooms. Finally, to test the attachment capacity of highly hydrophobic surfaces, the immersion assay revealed not to be as suitable as both the touch-transfer and the swab inoculation methods used since the attachment of bacteria was much lower in the immersion assay than in inoculation methods: 101 in the immersion and 104–105 in the swab inoculation touch-transfer methods, respectively. Nevertheless, it is an easy and practical method to study the bacterial attachment although it does not reflect commonly ways of bacterial contamination of surfaces7.

One limitation of our study was that the possible interference of the glycerol added to the bacterial inoculum on bacterial attachment and on the antibacterial activity of patterned films was not determined. Nevertheless, no differences in bacterial attachment were observed between glycerol at 5% and 40%. Also, the same inoculum containing PBS and glycerol was used to test the control (smooth) and patterned surfaces, what should have balanced the possible effects of glycerol on attachment. So, although we could not totally rule out some influence of glycerol on these methods, it seems unlikely. Another limitation was that bacterial attachment patterns and removal from surfaces was not assessed by high-resolution techniques as SEM. The agar contact method has shown to left no bacteria on similar surfaces after SEM analysis7.

Comparing all approaches tested, we concluded that the touch-transfer and swab inoculation methods were the most reproducible and the best at mimicking the various aspects of a real-world surface bacterial contamination. These procedures evaluated the antibacterial activity of hydrophobic films under real temperature and humidity conditions. The touch-transfer and the swab assays presented here were not pretended to replace the ISO 22196, but proved to be more realistic than that normative for the analysis of the antibacterial activity of the highly hydrophobic films under study. Therefore, considering these and other studies12,13, a new ISO method would be desirable as a reference method to study the antibacterial activity of highly hydrophobic patterned plastic surfaces.