Abstract
Spinal muscular atrophy (SMA) is one of the most common and severe genetic diseases. SMA carrier screening is an effective way to identify couples at risk of having affected children. Next-generation sequencing (NGS)-based expanded carrier screening could detect SMN1 gene copy number without extra experiment and with high cost performance. However, its performance has not been fully evaluated. Here we conducted a systematic comparative study to evaluate the performance of three common methods. 478 samples were analyzed with multiplex ligation probe amplification (MLPA), real-time quantitative polymerase chain reaction (qPCR) and NGS, simultaneously. Taking MLPA-based results as the reference, for 0 copy, 1 copy and ≥ 2 copy SMN1 analysis with NGS, the sensitivity, specificity and precision were all 100%. Using qPCR method, the sensitivity was 100%, 97.52% and 94.30%, respectively; 98.63%, 95.48% and 100% for specificity; and 72.72%, 88.72% and 100% for precision. NGS repeatability was higher than that of qPCR. Moreover, among three methods, NGS had the lowest retest rate. Thus, NGS is a relatively more reliable method for SMN1 gene copy number detection. In expanded carrier screening, compared with the combination of multiple methods, NGS method could reduce the test cost and simplify the screening process.
Introduction
Spinal muscular atrophy (SMA) is a common neuromuscular disorder. It is attributed to the degeneration of spinal and brainstem motor neurons, leading to progressive muscle weakness and atrophy and even respiratory failure and death. Its incidence is approximately 1 in 10,000 live births1,2,3,4,5. SMA is divided into four clinical subtypes according to the onset age and clinical manifestations3. All these forms are caused by mutations in the survival motor neuron 1 (SMN1) gene. More than 95% of SMA cases are caused by exon 7 deletion of this gene6. Additionally, SMN2 is a highly homologous gene to SMN1, with only several base pair differences7. A C-to-T nucleotide transition in exon 7 of SMN2 gene (c.840C>T) results in SMN2 protein truncation and instability through its effects on the exonic splicing enhancer, which is considered a critical functional consequence and distinguishes SMN1 from SMN2 gene. Many molecular genetic methods have been developed based on these differentiated nucleotides for SMN1 gene mutations detection.
SMA is a fatal disease, and the treatments are expensive. Carrier screening aims at identifying carrier couples with the risk of having affected babies of inheriting recessive disorders so as to provide genetic procreation choices and early medical management combined with genetic counseling. In 2008, the American College of Medical Genetics (ACMG) recommended that SMA carrier screening should be offered to all the couples6. In the guidelines for genetic condition carrier screening provided by the American College of Obstetrics and Gynecology (ACOG), SMA was one of the disorders recommended for carrier screening for all the women8. It is of great significance to prevent the births of the affected births9,10,11. The frequently used methods for SMA carrier screening are real-time quantitative polymerase chain reaction (qPCR)11,12,13,14, denaturing high-performance liquid chromatography (DHPLC)9, and multiplex ligation probe amplification (MLPA)15,16,17. Among them, MLPA is considered the gold standard technique, and qPCR is one of the most commonly used methods. Next-generation sequencing (NGS) method has been reported in recent years for SMA carrier screening18,19,20. Especially for expanded carrier screening (ECS) including SMA with NGS, extra molecular tests no longer have to be supplemented to detect SMA, simplifying the detection process and reducing the detection cost.
The carrier rate of SMA in different ethnic groups is variable, ranging from approximately 1% to 3%13,16,17, which may be caused by ethnic difference. However, for individuals from the same ethnic group, SMA carrier rate varied widely between the studies. For examples, SMA carrier rate had been reported as 1.43%17 and 1.88%13 in Southeast Asian, respectively. It ranges from 0.85 to 1.46% for African American13,14,17,21. These differences may be related to the sample size of different studies. However, it cannot be ruled out the possibility that the accuracy of the methods used may cause such differences. In a newborn screening study of SMA with real-time polymerase chain reaction, 8 of 15 positive results were confirmed as false-positives22. What’s more, the sensitivity and specificity of PCR-based methods were repeatedly reported to be less than 100%12,23,24. The advantages and limitations of the technical methods have been summarized, including qPCR, MLPA and DNA sequencing, et al.25. However, a comprehensive performance analysis and comparison has not been reported. In this study, we selected the frequently used qPCR method and the promising NGS approach and investigated their performance systematically for SMA detection. These methods were carried out in accordance with relevant guidelines and regulations.
Results
Study design
A total of 478 samples were re-analyzed with MLPA, qPCR and NGS methods simultaneously in this study. The MLPA results were used as the reference for the validation of qPCR and NGS methods. Prior to this, the samples with failed detection or ambiguous copy number results by MLPA were redetected until the effective copy number was identified (0, 1, 2, 3 or 4 copies). Additionally, 71 of the 478 samples, namely, 15 SMN1 homozygous deletion samples, 27 SMN1 heterozygous deletion samples and 29 SMN1 nondeletion (≥ 2 copies) samples, were selected for the repeatability study of NGS and qPCR methods.
Sensitivity and specificity
With MLPA method, 16 of the 478 samples were classified as homozygous deletion (0 copy of SMN1), 133 as heterozygous deletion (1 copy of SMN1), and 329 as normal (≥ 2 copies of SMN1); these results were consistent with the previous molecular diagnostic results. Taking MLPA-based results as the reference, in the qPCR experiments, the sensitivity, specificity and precision for the detection of 0 copy SMN1 gene were 100%, 98.63% and 72.72%, respectively. They were 97.52%, 95.48% and 88.72%, respectively for 1 copy SMN1 gene identification, and 94.30%, 100% and 100% for ≥ 2 copy SMN1 analysis (Table 1). In the NGS experiments, the sensitivity, specificity, and precision were all 100% for the analysis of SMN1 gene copy number (Table 2).
Taking the repeatability study experiment into account, for qPCR and NGS methods, a total of 620 reactions were implemented respectively and simultaneously for the 478 samples and 142 repetitions of the 71 repeatability study samples. In the qPCR experiments (Fig. 1), 26 samples were detected as ambiguous copy numbers, and 5 samples failed. In the remaining samples, 54 were classified as homozygous deletion (0 copy of SMN1) with qPCR; the results of 8 of these samples were disparate from the MLPA results in which 3 were classified as heterozygous deletion (1 copy) and 5 were classified as normal (≥ 2 copies). A total of 189 samples were classified as heterozygous deletion (1 copy of SMN1) by qPCR; the results of 19 of these samples were inconsistent with the MLPA results in which these samples were classified as normal (≥ 2 copies). A total of 346 samples were determined to be nondeletion using qPCR, one of which was determined to be a heterozygous deletion (1 copy) by MLPA. For NGS method (Fig. 2), a total of 9 samples were failed, and 8 samples were analyzed as ambiguous copy numbers, producing 2.74% redetection rate. In the remaining samples, except one false-positive sample in which 2 copies identified by MLPA was detected as one copy by NGS, all the other sample results by NGS were consistent with the MLPA results.
The results of qPCR. A total of 620 reactions were implemented for the 478 samples and 142 repetitions of the 71 repeatability study samples with qPCR. With qPCR method, 26 reactions results were as ambiguous copy numbers, 5 reactions failed, 54 reactions results were 0 copy SMN1 gene, 189 reactions results were 1 copy SMN1 gene, and 346 reactions results were ≥ 2 copies SMN1 gene, each of which is shown as a bar chart. In each bar chart, the samples that were analyzed as 0 copy, 1 copy and ≥ 2 copies of SMN1 gene with MLPA method are shown as the blue, orange and green, respectively.
The results of NGS. A total of 620 reactions were implemented for the 478 samples and 142 repetitions of the 71 repeatability study samples with NGS. With NGS method, 8 reactions results were as ambiguous copy numbers, 9 reactions failed, 46 reactions results were 0 copy SMN1 gene, 180 reactions results were 1 copy SMN1 gene, and 377 reactions results were ≥ 2 copies SMN1 gene, each of which is shown as a bar chart. In each bar chart, the samples that were analyzed as 0 copy, 1 copy and ≥ 2 copies of SMN1 gene with MLPA method are shown as the blue, orange and green, respectively.
Repeatability of NGS and qPCR
71 samples (15 of 0 copy, 27 of 1 copy and 29 of ≥ 2 copies of SMN1) were analyzed for the reproducibility of the results of the qPCR and NGS methods. Three repeated experiments for each sample were conducted with both qPCR and NGS. The detailed results are presented in Supplement Table S1.
In the repeated experiment of qPCR, the SMN1 homozygous deletion was detected in all replicates (Fig. 3), displaying the good reproducibility. For the heterozygous deletion, 92.6% samples were analyzed successfully and accurately in all replicates. In the remaining, one replication was classified as false negative result (Fig. 3). In 29 samples with ≥ 2 copies of SMN1 gene, only 48.3% samples were tested successfully and accurately in all replicates, and 12 samples were detected accurately in only two replications (34.5%), one replication (6.9%). The remaining (10.3%) were incorrectly detected as deletion in all replications (Fig. 3). For these inconsistent replications, they were detected as heterozygous deletion, homozygous deletion, ambiguous copy numbers or the failed (Supplement Table S1). These results manifested that the reproducibility of nondeletion (≥ 2 copies) samples with qPCR method was unsatisfactory and needed to be further improved.
The consistency of repeated experiments compared with the MLPA results. Horizontal axis represents the conditions of 0 copy, 1 copy and ≥ 2 copies of SMN1 gene detected by qPCR and NGS methods, respectively. Each bar chart represents the sample number used for repeatability study. In each bar chart, blue, red, green, and purple represent samples with three, two, one and 0 replicates result that consistent with MLPA results, respectively.
In the investigation of NGS repeatability, as shown in Fig. 3, the detection rate of homozygous deletion was 100% in all replicates. For heterozygous deletion (1 copy), except one sample with two failed replicates and another sample with one replicate identified as ambiguous copy number, the remaining (92.6%) was accurately analyzed. Among the nondeletion samples (with ≥ 2 copies of SMN1), 86.2% were tested successfully and accurately in all replicates. In the remaining 4 samples with 12 replications, three replications were failed, two were ambiguous copy numbers and one was 1 copy (Supplement Table S1). These results suggested that NGS reproducibility performance was significantly superior to that of qPCR.
Retest rate
In the clinical situation, the samples with the failed and ambiguous results needed to be retested to obtain the definite results. Thus, the retest rate is also an important parameter to evaluate the performance of a methodology. In the first detection run of 478 samples with MLPA, 17 samples were failed detection, and 15 were classified as having ambiguous copy numbers, generating a 6.69% retest rate. For 620 qPCR experiments, 26 samples were detected as ambiguous copy numbers, and 5 samples failed, generating a 5% retest rate. With NGS method, a total of 9 samples failed, and 8 samples had ambiguous copy numbers, producing 2.74% redetection rate, the lowest among the three methods studied. These samples were distributed throughout the collection period (Supplement Table S1), indicating it was not the sample collection time that caused failure or ambiguous results. We only performed retest for the samples with the failed or ambiguous results that were tested using the MLPA method. For 17 failed samples, two of the failures may have been caused by evaporation during the overnight hybridization or ligation step according to the manufacturer’s instructions, and after being retested, the quality control criteria were met. The rest of the samples failed was due to that the standard deviation of the reference probes in the reference samples or the dosage quotient of the reference probes in the test samples did not meet the quality control criteria of the manufacturer’s protocol. After being retested with the previous DNA, 11 samples met the quality control requirements of the protocol, and 4 samples still did not fulfill the quality criteria, while in the second retest with re-extracted DNA, the quality control criteria were met. For 15 samples with ambiguous copy numbers, after the first retest with the previous DNA, 6 of them were still identified as having ambiguous copy numbers, and in the second retest with re-extracted DNA, the results were specific copy numbers of SMN1 (Supplement Table S1).
Cost comparison
We compared the reagent cost of three methods. It was about 1.64, 0.61 and 7.23 dollars for MLPA, qPCR and NGS (ECS panel containing more than 200 genes related to 221 genetic diseases). If carrier screening is performed just for only SMA, the reagent cost of qPCR is the lowest, and highest with NGS. Thus, just considering test cost, qPCR is the best option for only SMA one disease carrier screening. However, under the condition of ECS, if cost is divided equally for each disease, the reagent cost of NGS method is the least expensive.
Discussion
In this study, we comparatively studied three molecular detection methods for SMN1 copy number. With the same quality template DNA, NGS displayed the lowest retest rate (2.74%), and MLPA and qPCR generated retest rates of 6.69% and 5%, respectively. Moreover, the precision and specificity of NGS were higher than those of qPCR. In addition, in the repeatability study of NGS and qPCR, both showed 100% reproducibility for SMN1 homozygous deletions, while NGS manifested higher repeatability relative to the qPCR method for the detection of heterozygous deletion and nondeletion of the SMN1 gene.
The MLPA assay is generally accepted as the gold standard for the molecular analysis of SMA for its high sensitivity and specificity, and it was selected for the validation of the qPCR and NGS methods in this study. It requires DNA free from impurities that may affect MLPA performance due to its greater sensitivity to impurities26,27. In most studies of SMA carrier screening, MLPA method was adopted as an independent screening tool15,28 or a validated method of positive results detected by other methods9,29,30,31. However, the retest rate of MLPA method has never been researched and analyzed systematically. In this study, the samples failed or with ambiguous results were retested and analyzed. All DNA samples used were extracted and purified with commercial extraction kits (MagPure Buffy Coat DNA Midi KF Kit, MAGEN), which contain magnetic nanoparticles and can effectively remove impurities. For 17 failed samples, after being retested with previous DNA, 13 samples met the quality control requirements of the protocol, illustrating that 13 failed results might be caused by experimental operation problems. With re-extracted DNA, the remaining failed samples fulfilled the quality criteria after being retested, indicating that 4 failed results might be resulted from the poor DNA extraction. For 15 samples with ambiguous copy numbers, according to the retest results, we speculated that 9 of them might be caused by experimental operation problems, and the remaining might be caused by the relatively low DNA quality. Thus, in these retest samples, 22 of them (22/478, 4.6%) might be caused by experimental operation problems, and 10 of them (10/478, 2.09%) might be attributed to the suboptimal DNA quality. These results demonstrated that the MLPA method possessed very strict quality control criteria for high sensitivity and specificity as well as the requirement of high-quality DNA samples. Additionally, for these retest samples (failed or having ambiguous copy numbers by MLPA the first time), 96.88% (31/32) and 71.88% (23/32) of them were successfully and accurately detected by NGS and qPCR method, respectively (Supplement Table S1), which further indicated that the high-quality experimental operation requirements might be the main reason leading to MLPA retest rate. In addition, these results illustrated MLPA method requires higher DNA quality compared with NGS method.
qPCR is a common method used to determine SMN1 gene copy number12,14,32,33,34,35. It was selected in this study for a comparative study of performance. Taking repetitive experiments into consideration, a total of 620 qPCR reaction were conducted here in which 5 samples failed and 26 samples were classified as having ambiguous copy numbers, yielding a retest rate of 5%. Thereinto, the ambiguous conditions contributed greatly to the retest rate, accounting for 83.87%. The other qPCR technique36 had also been evaluated with 42 samples, and 7 of them (16.6%) were detected as ambiguous copy numbers, while 6 of which were successfully identified as specific copy number (1 or 2 copies) with MLPA (unpublished data). Whether more PCR techniques have the same situation of high proportion of the ambiguous results need further validation and exploration. Up to now, only one study has made systematic statistics on the proportion of the failed and ambiguous results of SMA carrier screening with qPCR method37. The failure rate was 3.1%, and 3.3% fell into the equivocal range, most of which was attributed to suboptimal DNA quality and quantity37, the retest rate of which (6.4%) is slightly higher than that of this study (5%). In our study, except samples used for repeatability study, the remaining samples failed or with ambiguous results were not be retested. The systematic analysis for the reason of retest would be conducted subsequently. The sensitivity and specificity of PCR-based methods had been reported, ranging from 95.8 to 100% and 83.92 to 100%, respectively12,23,24,38. In addition, in a study of newborn screening with qPCR, 8 of 15 tested positive results were confirmed as false-positives with the positive prediction rate of 47%22. In our study, for the samples analyzed successfully, 21 tested results were false positives comparing with the MLPA results, generating sensitivity and specificity of 94.30% to 100% and 95.48% to 100%, respectively (Table 1), which is comparative compared with that of the other researches12,23,24,38. What’s more, several samples were false positive results in two successive repeated experiment in our study (Supplement Table S1). The differences in specificity between the researches might be related to extraction methods and quality of DNA samples23. Furthermore, we speculated that the discrepancy of the specificity and sensitivity between the researches may cause different SMA carrier rates in the same ethnic group13,14,17,21,35. Additionally, in the repeatability research, the detection of homozygous deletion was excellent in terms of the repeatability performance of the qPCR method. However, the reproducibility was unsatisfactory for heterozygous deletion and nondeletion samples, especially for nondeletion conditions. For example, three nondeletion samples were detected as heterozygous deletion in three repeated experiments, and another nondeletion sample was identified as heterozygous deletion in the first replication, homozygous deletion in the second replication, and a nondeletion in the third replication. Thus, in general, qPCR method has the advantages of low cost, a short detection period (approximately two days), short process flow and simple operation. Undeniably, not only does this method have a high retest rate but also its accuracy is relatively poor, especially for its reproducibility.
The NGS technique, as a relatively new method, has been developed and gradually applied to the determination of SMN1 gene copy number, even for SMA carrier screening18,19,31,39,40. It displayed good performance not only for the detection of homozygous deletion but also for heterozygous deletion in this study. In 9 failed samples, 8 of them were caused by insufficient sequencing data due to experimental operation problems. After being retested, the remaining one failed sample met the quality control requirements. Moreover, most of the samples that needed to be retested in the MLPA and qPCR tests were successfully tested with the NGS method, illustrating the higher repeatability and the lower requirements of DNA quality for the NGS method. Additionally, the sensitivity, specificity and precision were all 100%, higher than that of qPCR method and in conformity with that of the report19. In the repeatability study of 71 samples, for 213 repetitive reactions, 9 (4.23%) repeated experimental results were inconsistent with the MLPA results, 8 of which were classified as failed or as having ambiguous copy numbers, and one was a false-positive result; these inconsistencies were considerably lower than that of the qPCR method (11.74%), indicating higher repeatability of the NGS method compared with the qPCR method. Therefore, the NGS method can be used not only to detect homozygous deletion for SMA genetic diagnosis but also to analyze heterozygous deletion for carrier screening on account of its good performance. Besides, it had been confirmed that NGS method could detect the SNP associated with the “2 + 0” haplotype, accurately determine 3 and 4 copies of SMN1 gene, as well as detect point mutations of SMN1 gene19,20. What’s more, the copy number of SMN2 gene could also be analyzed with NGS method20,41,42. These detection properties need to be validated with many samples before clinical application. We are collecting and accumulating positive samples for the validation of detection of the SNP associated with the “2 + 0” haplotype, point mutations and ≥ 3 copies of SMN1 gene.
It is recommended by the ACOG and ACMG that all women and all couples regardless of race or ethnicity undergo carrier screening for SMA, a common severe genetic disease worldwide6,8. Thus, the selection of a suitable method is vitally important. Therefore, good performance should be the first priority. In this study, the NGS method showed desirable properties, with the lowest retest rate among the three methods and higher sensitivity, specificity and reproducibility relative to the qPCR method, meeting the performance requirement of SMA carrier screening. Moreover, with NGS technology, ECS has become widely available, accepted and implemented in recent years17,43,44. SMA is one of the diseases selected preferentially in the ECS panel. Before the development of SMN1 copy number analysis with NGS, it has no choice but to supplement additional detection, such as qPCR or MLPA for SMA screening in ECS13,30,45,46. This screening mode of combining multiple methods not only increases the screening cost but also raises the complexity of detection compared with a single method, with a negative effect on the reduction of the detection error rate. Thus, the NGS method for SMN1 copy number analysis is undoubtedly the best option, not only simplifying the process but also reducing the cost relative to the combination of multiple methods.
Except for qPCR, NGS and MLPA, there are other methods that be used for SMN1 copy number detection. The droplet digital PCR is another emerging technique for SMN1 copy number assay47,48,49,50,51. Although, the improved digital PCR technology has been reported52, the most are operational complexity and the related equipment and reagents are expensive. At present, it is mostly used as a validation method for positive results22,53 and has not been adopted extensively for carrier screening of SMA. In this study, we performed a comparative study only for three common methods, qPCR, NGS and MLPA, for SMN1 copy number detection. The NGS method, as a new technique for SMN1 copy number analysis, displayed desirable performance due to its sensitivity, specificity and repeatability. Moreover, its retest rate was the lowest of the three methods. It was confirmed as a fairly reliable method and would be the most promising method for carrier screening of SMA caused by SMN1 exon7 deletion. Most importantly, in ECS, the development of the NGS method for SMN1 copy number analysis could reduce the test cost and simplify the screening process compared with a combination of multiple methods.
Materials and methods
DNA samples
A total of 478 DNA samples tested previously with qPCR, MLPA or NGS for exon 7 copy number were enrolled in this study. They were collected from November 2014 to May 2019 from hospitals in mainland China. The informed consent was obtained from all subjects or, if subjects are under 18, from a parent and/or legal guardian. Sixteen samples were from SMA-diagnosed patients with SMN1 homozygous deletion, 74 samples were from the relatives of SAM patients with SMN1 heterozygous deletion, and the remaining 388 samples were from individuals without SMA-associated symptoms without family history information. Fifty-nine of the latter 388 samples were previously determined to have heterozygous exon 7 deletion of SMN1 by qPCR, MLPA or NGS. Genomic DNA was extracted from peripheral whole blood with the MagPure Buffy Coat DNA Midi KF Kit (MAGEN) following the manufacturer’s directions, and subsequently, the extracted DNA was used for the analysis of SMN1 exon 7 copy number with MLPA, qPCR and NGS simultaneously. This study was approved by the ethics committee of BGI (NO. BGI-IRB 18087).
NGS and data analysis
A capture array (Integrated DNA Technologies, Inc.) was designed and synthesized to capture the SMN1 gene and other 237 genes selected for carrier screening. The total size of the targeted region was 1,056,858 bp, and all SMN1 gene regions were included. For the enrichment of target regions, briefly, genomic DNA was first sheared with fragmentase followed by fragment selection with VAHTS™ DNA Clean Beads (Vazyme, Nanjing, Jiangsu, China). Subsequently, end repair, A-tailing reactions and adapter ligation were implemented. After a post-ligation cleanup, the amplification of fragmented DNA was performed with PCR to harvest sample libraries followed by hybridization with the capture array (Integrated DNA Technologies, Inc.) according to the manufacturer’s protocol. Then, the captured DNA samples were enriched using PCR to obtain the captured libraries, which were sequenced on the MGISEQ-2000 (MGI) platform according to the manufacturer’s instructions.
The primary data were acquired after image processing, error analyses and base calling in the run. Then, unqualified reads and adapter sequences were removed to acquire the clean reads. The alignment of clean reads against the human genome (version hg19/NCBI37 version) was performed with the Burrows Wheeler Aligner software package. The duplicate reads were marked with Picard MarkDuplicates, followed by local realignment and base quality re-correction by GATK. The depth of targeted regions for each sample was generated with GATK DepthOfCoverage.
SMN1 and SMN2 copy number analyses were conducted using a previously described protocol18 with slight modifications. Briefly, the number of reads that covered several nucleotide difference sites between SMN1 and SMN2 was counted, including three SMN1 loci, namely, chr5: 70,247,773, chr5: 70,247,724 and chr5: 70,247,921, and three SMN2 loci, namely, chr5: 69,372,353, chr5: 69,372,304 and chr5: 69,372,501. The read number covering exon 7 of the SMN1 and SMN2 genes was calculated based on whether the reads contained the SMN1 base or the SMN2 base at the difference sites denote as the depth of SMN1 and SMN2. We denote the total depth of SMN1 and SMN2 as depth of SMN. Before the calculation of the correction coefficient of the exon 7 copy number of SMN, we constructed the control sample set that all samples had two copies of exon 7 for both the SMN1 and SMN2 genes, and constructed the control gene set that with minimal difference when it’s depth divides into depth of SMN. The correction coefficient was calculated for the test samples with 3 steps: firstly, for each sample, we calculated depth ratios that each gene’s depth divides into depth of SMN; secondly, for each control gene set, we calculated the mean depth ratio of all control sample set as depth correction coefficient and divided into depth ratio of test sample as gene correction ; finally, we calculate the mean gene correction of all control gene set and get SMN exon 7 copy number correction coefficient θ, then 4*θ indicate the exon 7 copy number of SMN. A Bayesian hierarchical model was used to estimate the exon 7 copy numbers of the SMN1 and SMN2 genes. After calculated the confidence interval of the proportion of SMN1 depth p, we use 4*p*θ to estimate the exon 7 copy numbers of the SMN1. For final decision, we use simple thresholds of {0.5, 1.5, 2.5, 3.5} as boundary conditions, while the 95% confidence interval cover one of these thresholds, the result is treated ambiguous.
MLPA
The MCR-Holland SALSA MLPA Kit P060-050R (MRC-Holland) was used to reidentify the exon 7 copy number according to the manufacturer’s directions. The sequence-specific probes that capture the SMN1 and SMN2 genes were included in the kit54. The data were analyzed with Coffalyser.NET software (MRC-Holland). Samples with a copy number status were categorized as normal (2 copies), homozygous deletion (0 copies), heterozygous deletion (1 copy), heterozygous duplication (3 copies), homozygous duplication (4 copies) and ambiguous copy number by referring to the manufacturer’s manual.
qPCR
The SMN1 exon 7 copy number was analyzed with a TaqMan-MGB qPCR assay kit (Chromysky Medical Research, Shanghai, China) according to the report30, which contained specific probes and primers for exon 7 of the SMN1 gene. qPCR was carried out according to the manufacturer’s recommendations with an ABI StepOne Plus real-time PCR system (Thermo Fisher, USA). The data were analyzed with StepOne Software (v2.3), and the copy number was calculated using the manufacturer’s automated report system (SMASetup_v2.0.2 software, Shanghai Chromysky Medical Research Co., China)-based ΔΔCt method. The results were output as homozygous deletion (0 copies), heterozygous deletion (1 copy), nondeletion (≥ 2 copies), ambiguous copy number and failure.
Data availability
The data that support the findings of this study are presented in the Supplement Table S1.
References
Prior, T. W. et al. Newborn and carrier screening for spinal muscular atrophy. Am. J. Med. Genet. A 152A, 1608–1616. https://doi.org/10.1002/ajmg.a.33474 (2010).
Ogino, S. & Wilson, R. B. Spinal muscular atrophy: Molecular genetics and diagnostics. Expert Rev. Mol. Diagn. 4, 15–29. https://doi.org/10.1586/14737159.4.1.15 (2004).
Lunn, M. R. & Wang, C. H. Spinal muscular atrophy. Lancet 371, 2120–2133. https://doi.org/10.1016/s0140-6736(08)60921-6 (2008).
Pearn, J. Incidence, prevalence, and gene frequency studies of chronic childhood spinal muscular atrophy. J. Med. Genet. 15, 409–413. https://doi.org/10.1136/jmg.15.6.409 (1978).
Pearn, J. Classification of spinal muscular atrophies. Lancet 315, 919–922. https://doi.org/10.1016/s0140-6736(80)90847-8 (1980).
Prior, T. W., Professional, P. & Guidelines, C. Carrier screening for spinal muscular atrophy. Genet. Med. 10, 840–842. https://doi.org/10.1097/GIM.0b013e318188d069 (2008).
Lefebvre, S. et al. Identification and characterization of a spinal muscular atrophy-determining gene. Cell 80, 155–165. https://doi.org/10.1016/0092-8674(95)90460-3 (1995).
Committee on G. Committee opinion No. 691: Carrier screening for genetic conditions. Obstet. Gynecol. 129, e41–e55. https://doi.org/10.1097/AOG.0000000000001952 (2017).
Su, Y. N. et al. Carrier screening for spinal muscular atrophy (SMA) in 107,611 pregnant women during the period 2005–2009: A prospective population-based cohort study. PLoS ONE 6, e17067. https://doi.org/10.1371/journal.pone.0017067 (2011).
Basel-Vanagaite, L. et al. Genetic carrier screening for spinal muscular atrophy and spinal muscular atrophy with respiratory distress 1 in an isolated population in Israel. Genet. Test 12, 53–56. https://doi.org/10.1089/gte.2007.0030 (2008).
Archibald, A. D. et al. Reproductive genetic carrier screening for cystic fibrosis, fragile X syndrome, and spinal muscular atrophy in Australia: Outcomes of 12,000 tests. Genet. Med. 20, 513–523. https://doi.org/10.1038/gim.2017.134 (2018).
Feldkotter, M. et al. Quantitative analyses of SMN1 and SMN2 based on real-time lightCycler PCR: Fast and highly reliable carrier testing and prediction of severity of spinal muscular atrophy. Am. J. Hum. Genet. 70, 358–368. https://doi.org/10.1086/338627 (2002).
Haque, I. S. et al. Modeled fetal risk of genetic diseases identified by expanded carrier screening. JAMA 316, 734–742. https://doi.org/10.1001/jama.2016.11139 (2016).
Sugarman, E. A. et al. Pan-ethnic carrier screening and prenatal diagnosis for spinal muscular atrophy: Clinical laboratory analysis of >72,400 specimens. Eur. J. Hum. Genet. 20, 27–32. https://doi.org/10.1038/ejhg.2011.134 (2012).
Sukenik-Halevy, R. et al. Large-scale population carrier screening for spinal muscular atrophy in Israel–effect of ethnicity on the false-negative rate. Genet. Test Mol. Biomark. 14, 319–324. https://doi.org/10.1089/gtmb.2009.0089 (2010).
Zlotogora, J. et al. The Israeli national population program of genetic carrier screening for reproductive purposes. Genet. Med. 18, 203–206. https://doi.org/10.1038/gim.2015.55 (2016).
Westemeyer, M. et al. Clinical experience with carrier screening in a general population: Support for a comprehensive pan-ethnic approach. Genet. Med. 22, 1320–1328. https://doi.org/10.1038/s41436-020-0807-4 (2020).
Larson, J. L. et al. Validation of a high resolution NGS method for detecting spinal muscular atrophy carriers among phase 3 participants in the 1000 Genomes Project. BMC Med. Genet. 16, 100. https://doi.org/10.1186/s12881-015-0246-2 (2015).
Feng, Y. et al. The next generation of population-based spinal muscular atrophy carrier screening: Comprehensive pan-ethnic SMN1 copy-number and sequence variant analysis by massively parallel sequencing. Genet. Med. 19, 936–944. https://doi.org/10.1038/gim.2016.215 (2017).
Chen, X. et al. Spinal muscular atrophy diagnosis and carrier screening from genome sequencing data. Genet. Med. 22, 945–953. https://doi.org/10.1038/s41436-020-0754-0 (2020).
Lazarin, G. A. et al. An empirical estimate of carrier frequencies for 400+ causal Mendelian variants: Results from an ethnically diverse clinical sample of 23,453 individuals. Genet. Med. 15, 178–186. https://doi.org/10.1038/gim.2012.114 (2013).
Chien, Y. H. et al. Presymptomatic diagnosis of spinal muscular atrophy through newborn screening. J. Pediatr. 190, 124–129. https://doi.org/10.1016/j.jpeds.2017.06.042 (2017).
Cusco, I. et al. Implementation of SMA carrier testing in genetic laboratories: Comparison of two methods for quantifying the SMN1 gene. Hum. Mutat. 20, 452–459. https://doi.org/10.1002/humu.10144 (2002).
Gérard, N. G. et al. Genotype determination at the survival motor neuron locus in a normal population and SMA carriers using competitive PCR and primer extension. Hum. Mutat. 16(3), 253–263 (2000).
Prior, T. W. et al. Technical standards and guidelines for spinal muscular atrophy testing. Genet. Med. 13, 686–694. https://doi.org/10.1097/GIM.0b013e318220d523 (2011).
Schouten, J. & Galjaard, R. J. MLPA for prenatal diagnosis of commonly occurring aneuploidies. Methods Mol. Biol. 444, 111–122. https://doi.org/10.1007/978-1-59745-066-9_8 (2008).
Payne, A. B., Bean, C. J., Hooper, W. C. & Miller, C. H. Utility of multiplex ligation-dependent probe amplification (MLPA) for hemophilia mutation screening. J. Thromb. Haemost. 10, 1951–1954. https://doi.org/10.1111/j.1538-7836.2012.04843.x (2012).
Cali, F. et al. Carrier screening for spinal muscular atrophy in Italian population. J. Genet. 93, 179–181. https://doi.org/10.1007/s12041-014-0323-x (2014).
Dejsuphong, D. et al. Carrier frequency of spinal muscular atrophy in Thailand. Neurol. Sci. 40, 1729–1732. https://doi.org/10.1007/s10072-019-03885-5 (2019).
Zhang, J. et al. Carrier Screening and Prenatal Diagnosis for Spinal Muscular Atrophy in 13,069 Chinese Pregnant Women. J Mol Diagn 22, 817–822. https://doi.org/10.1016/j.jmoldx.2020.03.001 (2020).
Zhao, S. et al. NGS-based spinal muscular atrophy carrier screening of 10,585 diverse couples in China: A pan-ethnic study. Eur. J. Hum. Genet. https://doi.org/10.1038/s41431-020-00714-8 (2020).
Czibere, L. et al. High-throughput genetic newborn screening for spinal muscular atrophy by rapid nucleic acid extraction from dried blood spots and 384-well qPCR. Eur. J. Hum. Genet. 28, 23–30. https://doi.org/10.1038/s41431-019-0476-4 (2020).
Smith, M. et al. Population screening and cascade testing for carriers of SMA. Eur. J. Hum. Genet. 15, 759–766. https://doi.org/10.1038/sj.ejhg.5201821 (2007).
Chan, V. et al. Carrier incidence for spinal muscular atrophy in southern Chinese. J. Neurol. 251, 1089–1093. https://doi.org/10.1007/s00415-004-0487-z (2004).
Hendrickson, B. C. et al. Differences in SMN1 allele frequencies among ethnic groups within North America. J. Med. Genet. 46, 641–644. https://doi.org/10.1136/jmg.2009.066969 (2009).
Gomez-Curet, I. et al. Robust quantification of the SMN gene copy number by real-time TaqMan PCR. Neurogenetics 8, 271–278. https://doi.org/10.1007/s10048-007-0093-1 (2007).
Kraszewski, J. N. et al. Pilot study of population-based newborn screening for spinal muscular atrophy in New York state. Genet. Med. 20, 608–613. https://doi.org/10.1038/gim.2017.152 (2018).
Wirth, B. et al. Quantitative analysis of survival motor neuron copies: Identification of subtle SMN1 mutations in patients with spinal muscular atrophy, genotype-phenotype correlation, and implications for genetic counseling. Am. J. Hum. Genet. 64, 1340–1356. https://doi.org/10.1086/302369 (1999).
Lopez-Lopez, D. et al. SMN1 copy-number and sequence variant analysis from next-generation sequencing data. Hum. Mutat. 41, 2073–2077. https://doi.org/10.1002/humu.24120 (2020).
Bowen, B. M. et al. SMA identified: Clinical and molecular findings from a sponsored testing program for spinal muscular atrophy in more than 2,000 individuals. Front. Neurol. 12, 663911. https://doi.org/10.3389/fneur.2021.663911 (2021).
Tan, C. A. et al. Incorporating spinal muscular atrophy analysis by next-generation sequencing into a comprehensive multigene panel for neuromuscular disorders. Genet. Test Mol. Biomarkers 24, 616–624. https://doi.org/10.1089/gtmb.2019.0282 (2020).
Liu, B. et al. Survival motor neuron gene copy number analysis by exome sequencing: Assisting spinal muscular atrophy diagnosis and carrier screening. J. Mol. Diagn. 22, 619–628. https://doi.org/10.1016/j.jmoldx.2020.01.015 (2020).
Kaseniit, K. E. et al. Genetic ancestry analysis on >93,000 individuals undergoing expanded carrier screening reveals limitations of ethnicity-based medical guidelines. Genet. Med. 22, 1694–1702. https://doi.org/10.1038/s41436-020-0869-3 (2020).
Clarke, E. V. et al. Assessment of willingness to pay for expanded carrier screening among women and couples undergoing preconception carrier screening. PLoS ONE 13, e0200139. https://doi.org/10.1371/journal.pone.0200139 (2018).
Martin, J. et al. Comprehensive carrier genetic test using next-generation deoxyribonucleic acid sequencing in infertile couples wishing to conceive through assisted reproductive technology. Fertil. Steril. 104, 1286–1293. https://doi.org/10.1016/j.fertnstert.2015.07.1166 (2015).
Abuli, A. et al. NGS-based assay for the identification of individuals carrying recessive genetic mutations in reproductive medicine. Hum. Mutat. 37, 516–523. https://doi.org/10.1002/humu.22989 (2016).
Park, S. et al. Analytical validation of the droplet digital PCR assay for diagnosis of spinal muscular atrophy. Clin. Chim. Acta 510, 787–789. https://doi.org/10.1016/j.cca.2020.09.024 (2020).
Vidal-Folch, N. et al. Multiplex droplet digital PCR method applicable to newborn screening, carrier status, and assessment of spinal muscular atrophy. Clin. Chem. 64, 1753–1761. https://doi.org/10.1373/clinchem.2018.293712 (2018).
Zhong, Q. et al. Multiplex digital PCR: Breaking the one target per color barrier of quantitative PCR. Lab. Chip. 11, 2167–2174. https://doi.org/10.1039/c1lc20126c (2011).
Stabley, D. L. et al. SMN1 and SMN2 copy numbers in cell lines derived from patients with spinal muscular atrophy as measured by array digital PCR. Mol. Genet. Genom. Med. 3, 248–257. https://doi.org/10.1002/mgg3.141 (2015).
Wang, K. C. et al. A rapid molecular diagnostic method for spinal muscular atrophy. J. Neurogenet. 35, 29–32. https://doi.org/10.1080/01677063.2020.1853721 (2021).
Jiang, L. et al. Development and validation of a 4-color multiplexing spinal muscular atrophy (SMA) genotyping assay on a novel integrated digital PCR instrument. Sci. Rep. 10, 19892. https://doi.org/10.1038/s41598-020-76893-7 (2020).
Kariyawasam, D. S. T. et al. The implementation of newborn screening for spinal muscular atrophy: The Australian experience. Genet. Med. 22, 557–565. https://doi.org/10.1038/s41436-019-0673-0 (2020).
Schouten, J. P. et al. Relative quantification of 40 nucleic acid sequences by multiplex ligation-dependent probe amplification. Nucleic Acids Res. 30, e57. https://doi.org/10.1093/nar/gnf056 (2002).
Acknowledgements
We are grateful for all the participants in this investigation.
Author information
Authors and Affiliations
Contributions
S.Z. conceived the experiments and wrote the paper. Y.W., R.H., Z.F., and C.S. analyzed the data. X.X., C.F., L.F., and Y.Z. performed the experiments. Z.P., J.S. and X.H. revised the paper.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zhao, S., Wang, Y., Xin, X. et al. Next generation sequencing is a highly reliable method to analyze exon 7 deletion of survival motor neuron 1 (SMN1) gene. Sci Rep 12, 223 (2022). https://doi.org/10.1038/s41598-021-04325-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-021-04325-1
This article is cited by
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.