Abstract
The microelectronics industry is pushing the fundamental limit on the physical size of individual elements to produce faster and more powerful integrated chips. These chips have nanoscale features that dissipate power resulting in nanoscale hotspots leading to device failures. To understand the reliability impact of the hotspots, the device needs to be tested under the actual operating conditions. Therefore, the development of high-resolution thermometry techniques is required to understand the heat dissipation processes during the device operation. Recently, several thermometry techniques have been proposed, such as radiation thermometry, thermocouple based contact thermometry, scanning thermal microscopy, scanning transmission electron microscopy and transition based threshold thermometers. However, most of these techniques have limitations including the need for extensive calibration, perturbation of the actual device temperature, low throughput, and the use of ultra-high vacuum. Here, we present a facile technique, which uses a thin film contact thermometer based on the phase change material \(Ge_2 Sb_2 Te_5\), to precisely map thermal contours from the nanoscale to the microscale. \(Ge_2 Sb_2 Te_5\) undergoes a crystalline transition at \(\hbox {T}_{{g}}\) with large changes in its electric conductivity, optical reflectivity and density. Using this approach, we map the surface temperature of a nanowire and an embedded micro-heater on the same chip where the scales of the temperature contours differ by three orders of magnitude. The spatial resolution can be as high as 20 nanometers thanks to the continuous nature of the thin film.
Similar content being viewed by others
The fundamental understanding of thermal dissipation in an integrated chip1,2,3,4,5 requires the development of a versatile technique capable of reliably mapping the areal temperature of various components integrated in the chip ranging from nanometer to micrometer dimensions6,7. Various thermometers were developed to achieve this goal6,8,9,10,11,12,13,14,15,16,17,18,19,20,21 and can be broadly classified into two categories: non-contact and contact based thermometers. Techniques such as Raman9, fluorescence22, luminescence23 and transmission electron microscopy13,24,25 are non-contact thermometers. However, the areal resolutions of these methods are limited either by the optical diffraction limit26 or by the use of specific metals and semiconductors13. A scanning thermal microscope is an extensively used contact thermometer, but it typically suffers from contact-related artifacts that lead to an under prediction of the device temperature. This is due to the thermal coupling strength between the device and the SThM tip, which is material dependent and difficult to measure18,27.
Here a novel technique, which uses a phase change material to map the temperature of an operational microelectronic device, is presented. It requires minimal effort in temperature calibration and the temperature contour can be mapped using both contact and non-contact modes such as AFM, SEM or optical microscopes28,29,30,31,32. We map the temperature contours of a nanowire and an embedded micro-heater where the contour areas differ by three orders of magnitude.
To demonstrate the versatility and practicality of this technique, a recording head from a commercial hard disk drive is used. The head of the hard disk drive provides a unique platform for such studies as it has several embedded heat sources, which differ in heated area by three orders of magnitude33,34. At the microscale, it has a micro-heater, which is used to adjust the clearance between the head and the rotating disk35. The micro-heater is embedded a few micrometers from the surface, and it produces a microscale temperature contour. At the nanoscale, it has a nano-heater, which is used both as a heater and a thermometer. The nano-heater consists of a 200 nm wide, 1 \(\upmu \)m long, and 20 nm thick metal wire that is embedded 2 nm from the surface. Figure 1c shows the simulated surface temperature contours for the micro-heater and the nano-heater. In comparison to the micro-heater’s temperature field, the nano-heater’s areal temperature map is three orders of magnitude smaller (see Fig. 1d). Note that the nano-heater has a temperature coefficient of resistance (TCR) of 0.003/K, which is used to measure the average surface temperature. In this paper, it is quantitatively demonstrated that the temperature measured from the phase change temperature contour (PCTC) technique agrees well with the measured average surface temperature and the thermal simulation for both the micro-heater and the nano-heater.
Results and discussions
Self-heating of the nano-heater
To demonstrate the technique, we first characterize the Joule heating of the nano-heater inside the head of the hard disk drives. The head surface is coated with a 22 nm thick layer of \(Ge_2 Sb_2 Te_5\) thin film. The nano-heater is biased using a current source, across which the measured voltage drop is used to estimate the resistance increase of the nano-heater due to the dissipated Joule heat (Fig. 2a). The resistance change of the nano-heater is used to estimate the average temperature increase of the device temperature by \(R_{T}=R_{0}(1+\alpha \Delta T)\), where \(R_{0}\) is the room-temperature resistance at low current bias where no significant self-heating occurs, \(R_{T}\) is the resistance at the bias corresponding to the temperature T, \(\alpha \) is the temperature coefficient of resistance (TCR), and \(\Delta \)T is the average temperature rise due to the Joule heating. The temperature coefficient of resistance (\(\alpha \)) 0.003/K is determined separately in an oven using a 4-probe measurement scheme (see Supplementary section 1). Note that the effect of the thin layer on the heat transport of the system is negligible (see Supplementary section 2).
The amorphous \(Ge_2 Sb_2 Te_5\) is a chalcogenide phase change material that crystallizes at \(\hbox {T}_{g}\sim 149^{\circ }\)C for a dwell time of 5 min. This crystallization is accompanied by an increase in density and volume reduction, where AFM topography measurement shows as a reduction in the film height. Figure 2b–f show the AFM topography micrographs corresponding to different powers in the nano-heater. For nano-heater power smaller than 0.60 mW, the AFM shows no change in the topography of the \(Ge_2 Sb_2 Te_5\) film over the nano-heater, indicating that the surface temperature is lower than the crystallization temperature. When the nano-heater power is 0.75 mW, a small depression in the topography is observed centered at the hot spot of the nano-heater as shown in Fig. 2c. A further increase in the nano-heater power leads to a gradual increase in the area undergoing the crystallization, which is indicated by the lateral growth of the depressed area in the AFM images. Note that the boundary of the topography depression corresponds to the isotherm of the crystallization temperature. The evolution of the temperature contour area agrees reasonably well with the simulation as shown in Fig. 2h. Furthermore, we use the transition boundary measured at different nano-heater powers to map the temperature of the device. The rate of phase transition in \(Ge_2 Sb_2 Te_5\) is a function of both the temperature and the time. Here, the power in the nano-heater is increased incrementally with a fixed dwell time until the initial transition boundary is observed. The last transition boundary corresponds to the calibration temperature \(\hbox {T}_{{g}}\) at the largest heater power \(\hbox {P}_{{o}}\)=1.37 mW (Fig. 2f). Assuming that the temperature is linear with the applied power, the temperature isotherm \(\hbox {T}_{{i}}\) at each previous transition boundary (Fig. 2c–e) is given by:
where \(\hbox {T}_{{g}}\) is the calibrated \(Ge_2 Sb_2 Te_5\) crystalline transition temperature for the dwell time of 300 s during which the nano-heater is powered on, \(\hbox {P}_{{o}}\) is the nano-heater power at which the final transition boundary is measured, and \(\hbox {P}_{{i}}\) is the previous power with \(\hbox {P}_{{i}}\) < \(\hbox {P}_{{o}}\) in the nano-heater. Figure 2g shows the constructed temperature map of the device along with the simulation for \(\hbox {P}_{{o}}\) = 1.37 mW.
Figure 2h shows the phase change transition area calculated from the topography depression in the AFM image as a function of the power dissipated in the nano-heater. When the nano-heater power is lower than 0.60 mW, the transition area is zero signifying that the surface temperature is lower than the glass transition temperature \(\hbox {T}_{{g}}\) everywhere. At higher powers the transition area grows linearly with the dissipated power in the nano-heater. The simulation results are shown as the red dash line. Both the experiment and the simulation show a sharp increase in the phase change transition area beyond 0.60 mW. At much larger bias currents the poor match is because of our inability to capture the exact structural details in the simulation such as the actual thermal boundary conditions and the various material parameters. To further confirm the surface temperature, we simultaneously measure the resistance of the nano-heater and use a TCR of 0.003/K to estimate the average temperature of the heater. Figure 2h inset shows the measured surface temperature of the nano-heater as a function of the power dissipated. The red dot is the temperature from the PCTC technique at 0.60 mW derived from the x-axis intercept of the Fig. 2h. As expected, the temperature from the PCTC technique matches the temperature reading given by the resistance change. The excellent agreement between the temperature measured using the PCTC and TCR technique along with the simulation demonstrates that the PCTC technique can precisely map the high operational temperature of the nanoscale heater embedded in the chip.
Next we study the time response of the \(Ge_2 Sb_2 Te_5\) film to construct the temperature map of the device at a constant nano-heater power. Here, the growth of the transition boundary is tracked over time. It should be noted that the transient response of the nano-heater is six orders of magnitude faster than the \(Ge_2 Sb_2 Te_5\) phase change. Assuming that the phase change conversion follows an Arrhenius model and the conversion is linear with time, the temperature for each transition boundary is derived by monitoring the time needed for each transition boundary to develop. The temperature (\(T_{i}\)) at time \(t_{i}\) is given by:
where \(k_{B}\) is the Boltzmann constant, \(E_{A}\) \(\sim \) 2.6 eV is the activation energy \(Ge_2 Sb_2 Te_5\) transition, \(\hbox {T}_{g} \sim \) 149 \(^{\circ }\)C is the calibrated crystallization temperature at dwell time \(\hbox {t}_{{cal}}\) =300 s. It is worth noting that the temperatures of isotherms corresponding to shorter dwell times (\(t_{i}\) < \(t_{cal}\)) are higher than \(\hbox {T}_{{g}}\).
Figure 3a dots show the phase change transition area around the nano-heater as a function of the accumulated time for a constant power of 0.68 mW (see Supplementary section 3 and Video S3). The red line is the exponential fit with a time constant of 37.6 s. The transition temperature at different accumulated heating time is determined by using Eq. (2). Figure 3b shows the constructed temperature map of the device at the constant nano-heater power of 0.68 mW. In comparison to Fig. 2g, the temperature map is smaller and more elliptical since the nano-heater power is almost 50\(\%\) smaller. Figure 3c shows the temperature across nano-heater as a function of distance demonstrating the high resolution of the PCTC scheme. The continuous nature of our thin film allows for a higher spatial resolution, which is limited only by the grain size of \(Ge_2 Sb_2 Te_5\) (sub 20 nm) and the resolution of the imaging technique (< 10 nm)14.
Self-heating of the micro-heater
To demonstrate the versatility of the PCTC technique, we now characterize the Joule heating of a much larger micro-heater embedded in the head of the hard disk drive. The temperature contour of the micro-heater is three orders of magnitude larger than that of the nano-heater embedded in the same chip (as shown in Fig. 1) in terms of the contour area. The micro-heater is biased using a current source and the measured voltage drop across the nano-heater (thermometer) is used to estimate the dissipated Joule heat. The dwell time of 300 s at a constant micro-heater power is much longer than the thermal response time of the heater and the phase transition time beyond which the physical, optical and electrical properties change. The temperature contour of the micro-heater is mapped using an optical microscope by simply imaging the reflectivity change in the transition area. Figure 4a–d show the optical micrographs at different micro-heater powers. No change in reflectivity is observed below the dissipated power of 42 mW in the micro-heater. At the power of 43 mW, an increase in the reflectivity is observed at the center of the thermal hotspot due to the micro-heater. Note that the boundary of the transition area corresponds to the crystallization temperature. In comparison to the nano-heater, here the micro-heater requires 60 times more power to achieve the same surface temperature since the micro-heater is more deeply embedded and heats up a much larger volume. At higher micro-heater powers, the growth in the transition area indicates an increase in the thermal spot size with the same crystallization temperature \(\hbox {T}_{{g}}\) isotherm.
Figure 4f shows the constructed temperature map of the device along with the simulation. The dimensions and the overall shape of the transition contour from the experiments match well with the simulated \(\hbox {T}_{{g}}\) isotherms. Furthermore, we utilized the nano-heater as a thermometer by monitoring its resistance change at a very low current of 0.1 mA, in order to avoid self-heating, to measure the temperature rise due to the micro-heater. Figure 4e shows the surface temperature measured by the nano-heater as a function of the power dissipated in the micro-heater. The red line shows the micro-heater power beyond which the phase transition is observed in the optical micrograph. The expected rise of the surface temperature as derived from both the PCTC technique and from the nano-heater (acting as ‘thermometer’) is 2.9 K/mW. This shows an excellent agreement between the PCTC technique, the measured surface temperature and the simulation for the temperature map of the micro-heater.
Temperature calibration
Precise and relatively simple temperature calibration is a key advantage of the PCTC method compared to other techniques that require extensive temperature calibration. To calibrate the crystallization temperature \(\hbox {T}_{{g}}\) of the phase change material \(Ge_2 Sb_2 Te_5\), we rely on a pronounced structural property change at the phase change condition (Fig. 5a). The rate of this transformation from an amorphous state to the crystalline rock salt structure is well characterized by an activation energy of about 2.6 eV29,30. Due to this activation energy driven process the crystallization temperature is dependent on the dwell time of the sample. For this reason, the dwell time at a constant power condition is fixed at 5 min for both the nano-heater and the micro-heater. This dwell time is much longer than the response time of the two heaters36. Figure 5b inset shows the calibration sample, which is a photo-lithography defined 22 nm thick \(Ge_2 Sb_2 Te_5\) layer on top of a silicon wafer. The main figure shows the film thickness as a function of oven temperature. The dwell time at a constant oven temperature is 5 min after which the sample is allowed to cool down to room temperature, and the film thickness is measured using the AFM. At T = 149 \(^{\circ }\)C, the film thickness reduces, indicating a phase transition from the amorphous state to the crystalline state, as confirmed by the X-ray diffraction pattern (see Supplementary section 4).
The uncertainty in the temperature derived from this PCTC technique is primarily due to the fact that the crystallization rate of the phase change material does not have a large abrupt jump at a single temperature (as in a first order phase transition). As a result, the full temperature history of the sample, not just the last power used, can influence the size of the observed contour (see Supplementary section 5). For both the nano-heater and the micro-heater, the estimated temperature step is kept at 10 K, which leads to a slight under-prediction of the temperature by around 2 K at the 149 \(^{\circ }\)C crystallization condition.
It is noteworthy that in most other high resolution temperature mapping techniques, the application is limited to the large scale devices. Here we demonstrated the thermal measurements of the two heaters that produced thermal contours with dimensions that differ by three orders of magnitude, while maintaining sub 20 nm resolution in both cases. This technique is extremely versatile and does not require the use of expensive microscopes like STEM. At the microscale, even an inexpensive optical microscope can be used to map the temperature of the hotspots or heat sources in operating microelectronics devices.
Finally, the limitations of the presented PCTC technique are discussed. Although the technique is versatile and can be used for nanoscale to microscale spatial heat sources with minimal calibration challenges, it has two main limitations. First, the areal contour represents the isotherm at \(\hbox {T}_{{g}}\), and to extract the temperature gradient one needs to perform mapping for at least two different power levels or track the phase change with time. Secondly, the technique is limited to a device temperature higher than the crystallization temperature of the deposited phase change material. In our case, \(Ge_2 Sb_2 Te_5\) crystallizes at temperature of 149 \(^{\circ }\)C for the dwell time of 5 min is used. Both embedded heaters are able to reach temperatures higher than this \(\hbox {T}_{{g}}\). For other systems where reaching a similar temperature would be difficult or impossible, the issue could be overcome by choosing a different composition or phase change materials with lower \(\hbox {T}_{{g}}\)37,38,39,40.
Conclusion
To summarize, we introduce a versatile phase-change-material-based temperature mapping technique for operational microelectronic devices that can spatially resolve temperature from nanoscale to microscale dimensions. It can be used to characterize surface temperatures with neglectable temperature interference due to the deposited measurement film and with minimal calibration. A thorough understanding of the heat dissipation in various nanoscale devices, such as the aforementioned nano-heater, may lead to more efficient and powerful integrated chips, and hence holds great economic value to the industry.
Methods
Experimental set-up
The microelectronic device is held on a metal fixture with electrical pins. The components inside the device such as the heaters are powered by Keithley 2602 SYSTEM SourceMeter, which is controlled by a Python script. A 22 nm thin film of Ge2Sb2Te5 is sputtered on the surface of the device. The topography change or the reflectivity change of the thin film due to the heaters are measured by Digital Instruments Dimension 3100 AFM or an optical microscope respectively. In the temperature calibration of the Ge2Sb2Te5, a silicon wafer with a photo-lithography defined 22 nm thick Ge2Sb2Te5 layer is heated in a customized copper chamber, where the temperature is measured by a type-K thermocouple. The thickness of the layer is also measured by the AFM.
Simulation
Thermal simulations of the micro-heater and nano-heater devices in Fig. 1c,d were performed using finite element models in ANSYS Mechanical APDL version 17.2. The nano-heater thermal simulation in Fig. 2g was modeled using a finite element model in the ANSYS Workbench Thermo-electric module version 17.2. The device surfaces were modeled using a convection cooling boundary condition with a coefficient of 50 W/(\(\hbox {m}^{2}\) K).
References
Haensch, W. et al. Silicon CMOS devices beyond scaling. IBM J. Res. Dev. 50, 339–361 (2006).
Cavin, R., Zhirnov, V., Herr, D., Avila, A. & Hutchby, J. Research directions and challenges in nanoelectronics. J. Nanopart. Res. 8, 841–858 (2006).
Pop, E. Energy dissipation and transport in nanoscale devices. Nano Res. 3, 147–169 (2010).
Dejene, F. K., Flipse, J., Bauer, G. E. W. & van Wees, B. J. Spin heat accumulation and spin-dependent temperatures in nanopillar spin valves. Nat. Phys. 9, 636–639 (2013).
Jin, C. Y., Li, Z., Williams, R. S., Lee, K.-C. & Park, I. Localized temperature and chemical reaction control in nanoscale space by nanowire array. Nano Lett. 11, 4818–4825 (2011).
Brites, C. D. S. et al. Thermometry at the nanoscale. Nanoscale 4, 4799–4829 (2012).
Lee, J. & Kotov, N. A. Thermometer design at the nanoscale. Nanotoday 2, 48–51 (2007).
Wilde, Y. D. et al. Thermal radiation scanning tunnelling microscopy. Nature 444, 740–743 (2006).
Deshpande, V. V., Hsieh, S., Bushmaker, A. W., Bockrath, M. & Cronin, S. B. Spatially resolved temperature measurements of electrically heated carbon nanotubes. Phys. Rev. Lett. 102, 105501 (2009).
Tessier, G., Bardoux, M., Boue, C., Filloy, C. & Fournier, D. Back side thermal imaging of integrated circuits at high spatial resolution. Appl. Phys. Lett. 90, 171112 (2007).
Nonnenmacher, M. & Wickramasinghe, H. K. Scanning probe microscopy of thermal conductivity and subsurface properties. Appl. Phys. Lett. 61, 168 (1992).
Shi, L., Plyasunov, S., Bachtold, A., McEuen, P. L. & Majumdar, A. Scanning thermal microscopy of carbon nanotubes using batch-fabricated probes. Appl. Phys. Lett. 77, 4295 (2000).
Mecklenburg, M. et al. Nanoscale temperature mapping in operating microelectronic devices. Science 347, 629–632 (2015).
Brintlinger, T., Qi, Y., Baloch, K. H., Goldhaber-Gordon, D. & Cumings, J. Electron thermal microscopy. Nano Lett. 8, 582–585 (2008).
Guo, H. et al. Vanadium dioxide nanowire-based microthermometer for quantitative evaluation of electron beam heating. Nat. Commun. 5, 4986 (2014).
Gao, Y. & Bando, Y. Carbon nanothermometer containing gallium. Nature 415, 599 (2002).
Martinek, J., Klapetek, P. & Campbell, A. C. Methods for topography artifacts compensation in scanning thermal microscopy. Ultramicroscopy 155, 55–61 (2015).
Menges, F. et al. Temperature mapping of operating nanoscale devices by scanning probe thermometry. Nat. Commun. 7, 10874 (2016).
Kinkhabwala, A., Staffaroni, M., Suzer, O., Burgos, S. & Stipe, B. Nanoscale thermal mapping of HAMR heads using polymer imprint thermal mapping. IEEE Trans. Magn. 52, 1–4 (2015).
Kim, K., Jeong, W., Lee, W. & Reddy, P. Ultra-high vacuum scanning thermal microscopy for nanometer resolution quantitative thermometry. ACS Nano 81, 114901 (2012).
Hwang, G., Chung, J. & Kwon, O. Enabling low-noise null-point scanning thermal microscopy by the optimization of scanning thermal microscope probe through a rigorous theory of quantitative measurement. Rev. Sci. Instrum. 85, 114901 (2014).
Okabe, K. et al. Intracellular temperature mapping with a fluorescent polymeric thermometer and fluorescence lifetime imaging microscopy. Nat. Commun. 3, 705 (2012).
Kucsko, G. et al. Nanometre-scale thermometry in a living cell. Nature 500, 54–58 (2013).
Idrobo, J. C. et al. Temperature measurement by a nanoscale electron probe using energy gain and loss spectroscopy. Phys. Rev. Lett. 120, 095901 (2018).
Feng, et al. Electronic structure and enhanced charge-density wave order of monolayer VSe2. Nano Lett. 18, 4493–4499 (2018).
Christofferson, J. et al. Microscale and nanoscale thermal characterization techniques. J. Electron. Packag. 130, 041101 (2008).
Menges, F., Riel, H., Stemmer, A. & Gotsmann, B. Quantitative thermometry of nanoscale hot spots. Nano Lett. 12, 596–601 (2012).
Fritzsche, H. & Ovshinsky, S. R. Calorimetric and dilatometric studies on chalcogenide alloy glasses. J. Non-Cryst. Solids 2, 148–154 (1970).
Friedrich, I., Weidenhof, V., Njoroge, W., Franz, P. & Wuttig, M. Structural transformations of \(Ge_2 Sb_2 Te_5\) films studied by electrical resistance measurements. J. Appl. Phys. 87, 4130 (2000).
Morales-Sanchez, E., Prokhorov, E. F., Mendoza-Galvan, A. & Gonzalez-Hernandez, J. Determination of the glass transition and nucleation temperatures in \(Ge_2 Sb_2 Te_5\) sputtered films. J. Appl. Phys. 91, 697 (2002).
Lazarenko, P. I. et al. Electrical properties of the \(Ge_2 Sb_2 Te_5\) thin films for phase change memory application. AIP Conf. Proc. 1727, 020013 (2016).
Burr, G. W. Phase change memory technology. J. Vac. Sci. Technol. B 28, 223 (2010).
Wu, H., Xiong, S., Canchi, S., Schreck, E. & Bogy, D. Nanoscale heat transfer in the head-disk interface for heat assisted magnetic recording. Appl. Phys. Lett. 108, 093106 (2016).
Shimizu, Y. et al. Nano-scale defect mapping on a magnetic disk surface using a contact Sensor. IEEE Trans. Magn. 35, 3426–3432 (2011).
Rajauria, S., Ruiz, O., Canchi, S. V., Schreck, E. & Dai, Q. Electrostatically tunable adhesion in a high speed sliding interface. Phys. Rev. Lett. 120, 026101 (2018).
Schreck, E., Fontana, R. E. & Singh, G. P. Thin film thermocouple sensors for measurement of contact temperatures during slider asperity interaction on magnetic recording disks. IEEE Trans. Magn. 28, 2548–2550 (1992).
Xiong, F., Yalon, E., Behnam, A., Neumann, C. M., Grosse, K. L., Deshmukh, S. & Pop E. Towards ultimate scaling limits of phase-change memory. In Proceedings of IEEE International Electron Devices Meeting 4.1.14.1.4 (IEEE, San Francisco, CA, USA, 2016).
Chen, Y. M. & Kuo, P. C. Effect of Ag or Cu doping on erasable phase-change Sb-Te thin films. IEEE Trans. Magn. 34, 432–434 (1998).
Fu, X. et al. Novel solid-solid phase change materials with biodegradable trihydroxy surfactants for thermal energy storage. RSC Adv. 5, 68881–68889 (2015).
Alkan, C., Gunther, E., Hiebler, S., Ensari, O. F. & Kahraman, D. Polyurethanes as solid-solid phase change materials for thermal energy storage. Sol. Energy 86, 1761–1769 (2012).
Acknowledgements
The authors would like to thank I. McFadyen for careful reading of the manuscript. Q.C would like to thank Western Digital Corporation for financial support for the internship.
Author information
Authors and Affiliations
Contributions
The work was conceived by S.R. and E.S. The experimental setup were designed and implemented by Q.C. and S.R. The experiments were performed and analyzed by Q.C. under the supervision of S.R. and E.S. Thermal simulation was done by R.S. Phase change material was deposited by J.R. The manuscript was written by S.R. and Q.C with comments and input from all authors.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Cheng, Q., Rajauria, S., Schreck, E. et al. Precise nanoscale temperature mapping in operational microelectronic devices by use of a phase change material. Sci Rep 10, 20087 (2020). https://doi.org/10.1038/s41598-020-77021-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-77021-1