Abstract
In this study we aim to evaluate the assessment of bronchial pathologies in a murine model of lung transplantation with grating-based X-ray interferometry in vivo. Imaging was performed using a dedicated grating-based small-animal X-ray dark-field and phase-contrast scanner. While the contrast modality of the dark-field signal already showed several promising applications for diagnosing various types of pulmonary diseases, the phase-shifting contrast mechanism of the phase contrast has not yet been evaluated in vivo. For this purpose, qualitative analysis of phase-contrast images was performed and revealed pathologies due to previous lung transplantation, such as unilateral bronchial stenosis or bronchial truncation. Dependent lung parenchyma showed a strong loss in dark-field and absorption signal intensity, possibly caused by several post transplantational pathologies such as atelectasis, pleural effusion, or pulmonary infiltrates. With this study, we are able to show that bronchial pathologies can be visualized in vivo using conventional X-ray imaging when phase-contrast information is analysed. Absorption and dark-field images can be used to quantify the severity of lack of ventilation in the affected lung.
Similar content being viewed by others
Introduction
Lung transplantation often remains as the last therapeutic option in advanced pulmonary disease such as mucoviscidosis, COPD or idiopathic pulmonary fibrosis, especially when conservative therapeutic approaches have not been successful. The International Society for Heart and Lung Transplantation reported a total number of 4452 lung transplantations that were performed in 20171. The mean survival after a primary lung transplant procedure between 2010 and June 2017 was 6.7 years. Surviving the first year after transplantation increased the median survival to 8.9 years. The most common causes of death after transplantation are infection, graft failure and acute rejection as well as bronchiolitis obliterans syndrome (BOS)1. Apart from changes occurring directly after surgery like a pneumo- or hemothorax, complications affecting the airways, mainly in the region of the anastomosis, are common post-transplantational risks. The most frequent airway complication besides anastomosis dehiscence, infections, or fistula is bronchial stenosis with a frequency ranging between 3.5 and 32%2,3,4,5. The stenosis occurs either in the area of the anastomosis or slightly further distal3. Bronchial stenosis may become symptomatic with cough, dyspnoea or recurrent pneumonia. A decline in lung function may also be observed. As the clinical symptoms of bronchial stenosis are ambiguous, bronchoscopy—as an invasive examination technique—is the standard of reference for the diagnosis of this pathology6. Chest X-ray may indicate bronchial stenosis by showing consecutively hypoventilated areas. To actually verify the luminal constriction itself computed tomography (CT) imaging is necessary, coming along with a higher radiation dose.
Additional to conventional attenuation-based X-ray radiography, a method creating phase-contrast and dark-field images by using the refraction and small-angle scattering of the X-ray beam has been developed. Therefore, a three-grating Talbot-Lau interferometer is interposed between the X-ray source and the detector7,8. The diagnostic value of dark-field imaging (DFI) has already been proven for the diagnosis of several pulmonary diseases, such as pulmonary fibrosis, emphysema, pneumothoraces and lung cancer in mouse models9,10,11,12. For these approaches alterations in the high dark-field signal of healthy lung parenchyma, caused by small angle X-ray scattering at alveolar walls, were used to detect disease-related changes in lung tissue, indicated by a loss of dark-field signal strength.
In contrast to DFI, phase-contrast imaging (PCI) using a conventional X-ray source has not been evaluated for examination of the lungs yet. It is based on the phase-shift of the X-ray beam when passing through tissue, leading to a visual impression of enhanced borders between different anatomical structures, such as the trachea or main bronchi13.
In this in vivo proof-of-principle study, PCI was assessed for the first time with regard to its use for bronchial imaging in mice. We assumed that PCI would be an appropriate method to visualize the bronchial system due to the interface between the air-filled bronchi and its surrounding tissue. Furthermore, we hypothesized that visualizing bronchial pathologies in mice that underwent single lung transplantation would be possible for the first time using radiography acquired with grating-based interferometry.
Results
Quantitative image analysis—absorption and dark-field signal measurements of lung parenchyma
The lungs of 46 transplanted mice were analysed for quantitative absorption and dark-field signal intensities at TP1. Four mice had to be excluded from the measurements due to the development of a left-sided pneumothorax (Fig. 1). One mouse died shortly after the first scan and therefore was excluded as well.
When comparing the dark-field signal intensities of the transplanted (\(0.681 \pm 0.215\)) with the control lungs (\(1.475 \pm 0.184\)), a significant loss of signal strength of the transplanted lungs was observed (\(p < 0.001\)). For absorption signal intensity, a significant increase of absorption between the transplanted (\(0.943 \pm 0.078\)) and control lungs (\(0.788 \pm 0.069\)) was measured (\(p < 0.001\)) (Fig. 2).
As a second approach for quantitative analysis, the signals derived by the lungs over time, comparing TP1 and TP2, were measured. Therefore, the lungs of a total of 27 mice, that underwent a second measurement, were analysed. There was no significant change in absorption signal intensity for the transplanted lungs, comparing TP1 and TP2 (\(p = 0.09\)). By contrast, a slight but still significant increase (\(p = 0.04\)) of dark-field signal intensity for the transplanted lungs was observed between TP1 (\(0.656 \pm 0.234\)) and TP2 (\(0.722 \pm 0.251\)). Interestingly, when taking a look at the control lungs, a significant decrease in dark-field signal intensity (TP1: \(1.507 \pm 0.168\); TP2: \(1.442 \pm 0.263\); \(p < 0.05\)) as well as increase of absorption in absorption images (TP1: \(0.789 \pm 0.075\); TP2: \(0.836 \pm 0.067\); \(p < 0.05\)) could be observed (Fig. 3).
Qualitative image analysis—phase contrast imaging of bronchial stenosis
When carefully analysing the phase-contrast images of the transplanted mice at TP1, 24 lungs out of 46 lungs showed decreased ventilation, of which \(n = 14\) had visible irregularities of the left main bronchus. These irregularities either became visible as a stenosis (\(n = 4\)) of the bronchus or as a bronchial truncation (\(n = 10\)) (Fig. 4).
A total of 8 mice showed improved ventilation of their transplanted lungs in absorption and DFI at TP2, compared to TP1. When taking a closer look at these animals, a decrease of left-sided bronchial irregularities over time could be observed in 6 mice: either were the bronchial parts located distally the cuff visible again or was the degree of stenosis declining (Figs. 5 and 6).
Discussion
Besides primary graft dysfunction, acute rejection, postoperative infection and haemorrhage, as well as vascular anastomotic complications, large airway complications are one of the most important adverse events after lung transplantation14. The most important cause for large airway complications is central airway stenosis (CAS). It can include the anastomosis region. Up to 15% of all patients develop CAS within one year after lung transplantation15. Complications involve bronchial dehiscence, exophytic excessive granulation tissue formation, tracheo-bronchomalacia, bronchial fistulas, and endobronchial infections2. Most of these complications, including CAS, can be visualised using computed tomography16. By contrast, conventional absorption imaging shows alterations due to indirect changes of bronchial pathologies, such as atelectasis, rather than visualizing the bronchial system itself. Therefore, the authors of this study hypothesised phase-contrast imaging to be a helpful tool for diagnosing post transplantational large airway complications, as it strongly enhances the edges of the bronchial system, making it visible with a conventional imaging setup for the first time.
We were able to clearly distinguish bronchial stenosis—visible as decreasingly aerated bronchial lumen, followed by dystelectasis of the dependent lung parenchyma—from bronchial truncation, where there was no aerated bronchial lumen visible anymore, leading to distinct ventilation deficiency of the affected lung. Alterations of bronchial pathologies over time were also visible, helping to understand, how pulmonary atelectases altered. This might be very helpful when thinking about clinical practice, as targeted diagnostic and therapeutical bronchoscopy can be performed in these patients, even without the need to perform a CT scan prior to intervention.
When analyzing the signals derived by the transplanted lungs and comparing it with those of the control lungs, a significant change in both dark-field and absorption images was detected after lung transplantation. Absorption images showed an increase of absorption, and the corresponding dark-field images revealed a loss of signal intensity, both being consistent with a decreased proportion of ventilated pulmonary parenchyma within the transplanted lung. This might be caused by several post transplantational pathologies, such as atelectasis due to bronchial stenosis, pleural effusion and/or haemorrhage, as well as consolidations due to pulmonary infiltrates (e.g. infectious, necrotic or inflammatory). As there were no CT scans acquired in this study, this remains unclear. It is important to point out, that the changes in signal intensities observed in the transplanted lungs are not necessarily connected to large airway pathologies, as complications are diverse and multiple pathologic changes can occur simultaneously: The most important postoperative complications in animal studies besides large airway pathologies include thrombosis of a bronchial vein or artery, respiratory infections, pleural effusion, pulmonary edema, and graft rejection. This might explain the observation, that not all of the lungs showing a loss of ventilation presented visible bronchial pathologies17,18.
After two months (TP2) an overall increase of dark-field signal intensity was measured, indicating an improved ventilation of the transplanted lungs compared to TP1. Although no significant change of absorption signal intensity was detected, a slight decrease of absorption was observed, which can be explained by the better aeration of the transplanted lungs as well. In the corresponding phase-contrast images, some of the lungs showing signal alterations as described, revealed recurrent bronchial stenosis, most likely being the reason for improved ventilation. Reversible bronchial stenosis can be caused by mucus plugging or bronchial haemorrhage. Development of scar tissue could rather be a reason for persisting bronchial stenosis, just as bronchial dehiscence, e.g. due to cuff displacement. According to literature, an undersized diameter of the cuff as well as foreign-body reactions due to the cuff may occur, possibly leading to bronchial stenosis and truncation. Furthermore, there is a given risk for twisting of the bronchi after anastomosis, also resulting in bronchial truncation19. Disadvantageously, for both time points in the experiments described in this work, the specific reason causing bronchial obstruction remains unclear, as we neither have histology from the cuff region nor CT scans. Besides, thinking from a more practical and diagnostic point of view, knowing the exact reason for a bronchial pathology might be less important than showing the pathology at all (and therefore making its diagnosis possible), as its cause will hardly be explained by conventional X-ray imaging alone. Further examinations based on CT and bronchoscopy would be necessary in any case. Nonetheless, investigations focusing on histopathological changes of the cuff region after lung transplantation are preferable.
When taking a look at the signal development over time of the control lungs, an interesting observation was made: Both absorption and dark-field images indicated signal changes similar to the transplanted lungs at TP1—to a very discrete but still significant extend. A possible explanation for this observation might be, that the control lungs had to overcompensate the poor condition of the transplanted lungs at TP1 and therefore were hyper-inflated. As the transplanted lungs slightly recovered over time, the recipients’ native lungs returned to their physiological state of capacity20.
Four animals had to be excluded from the signal analysis as they had developed a large left-sided pneumothorax after lung transplantation. According to literature, post transplantational pneumothoraces most likely occur due to bronchial leaks21. One major flaw of this study might be that there is no external standard of reference, as there are no computed tomography scans nor histological examinations of the large airways and the region of the cuff. The conventional X-ray images of the recipients’ own, right-sided lungs served as control, concerning the degree of ventilation as well as the bronchial system. This might be critical because—as shown for ventilation—the native organ can also be influenced by the transplantation. Further studies of the bronchial system with a strong standard of reference are necessary.
Multiple murine in vivo studies about imaging pulmonary diseases using grating-based radiography have been performed so far, almost unexceptionally focusing on the dark-field information and comparing it with absorption images. With the current study, we investigated the value of phase-contrast imaging for the first time, proving this imaging modality to markedly improve the diagnostic value of conventional chest radiography for the detection of large airway pathologies in living mice that underwent single lung transplantation. Additionally, this work perfectly shows the potential of grating-based X-ray imaging to address multiple organ-specific pathologies, as absorption (osseous, mediastinal structures), dark-field (lung parenchyma) and phase–contrast information (bronchial system) are simultaneously available. The authors of this study are fully aware of the fact, that this conventional imaging technique is most likely not going to replace CT or bronchoscopy in case of possible large airway pathologies. But thinking of future clinical applications, it might be eligible for earlier detection of bronchial stenosis and therefore help transferring the patient to dedicated airway diagnostics within a narrow time frame. However, the transition of this technique from pre-clinical research to clinical routine is far from being trivial. Different kinds of technical requirements have to be met, such as the increased field-of-view, the higher grating structures needed due to higher energies used, or the setup design. In order to investigate and address the technical challenges of transferring grating-based interferometry to humans, research has been extended to larger in vivo animals and post-mortem human in recent years22,23,24,25. Finally, the investigations on imaging have been successfully extended to human in the clinic at a prototype dark-field radiography setup where first studies are going on.
Materials and methods
Single left lung transplantation
All animal procedures were performed with permission of the local regulatory authority, Regierung von Oberbayern (ROB), Sachgebiet 54, 80534 München, approval number AZ 55.2-1-54-2532-61-2015. The ethics committee reviewed the application according to §15 TSchG German Animal Welfare Law.
A total of \(n=102\) male mice were used for the experiments (all 8 to 12 weeks old), of which \(n=51\) served as donors and \(n=51\) served as recipients. Briefly, donors were anesthetized with an i.p. injection of ketamine/xylazine. The pulmonary artery (PA), bronchus and pulmonary vein (PV) were carefully separated one from the other with blunted forceps, prior to cuffing with, respectively, 24G, 20G and 22G cuffs. The left lung graft was perfused i.v. with \(3\,\)mL of Perfadex. The recipient mouse was anesthetized with a mixture of medetomidine (\(1\,\)mg/kg), midazolam (\(0.05\,\)mg/kg) and fentanyl (\(0.02\,\)mg/kg), intubated and connected to a small animal ventilator (Harvard apparatus), at a respiratory rate of \(120\,\)bpm and a tidal volume of \(300\,\)µL. The chest was opened on the left side between ribs 3 and 4 and the native left lung retracted with a clamp. The hilar structures were carefully separated one from the other with blunted forceps. After arrest of the blood and air flow towards the left lung, the cuffed graft PA, bronchus and PV were inserted into the recipient counterparts, and the connection between donor and recipient structures was secured with 9-0 sutures. The native left lung was removed and the incision in the chest was closed with a 6-0 suture, after removing all potential air bubbles from the chest. Antagonist was administrated and the animal was extubated when it showed signs of spontaneous breathing. After the operation, the recipient mice were allowed to recover at \({30}\,^{\circ }\hbox {C}\) and received buprenorphine (\(0.1\,\hbox {mg}/\hbox {kg}\))26.
Imaging protocol
All mice were imaged shortly after lung transplantation (time point 1/TP1). A subgroup of \(n=27\) mice was scanned at a second time point two months later (TP2). The small-animal X-ray dark-field CT setup presented in our work was developed in collaboration with Bruker MicroCT and consists of a compact rotating CT gantry built into a conventional microCT housing, suitable for preclinical research27,28. The grating-interferometer was adapted to the gantry and consists of three gratings: a source grating (gold, period \(p=10\,\)µm, height \(h=35\,\)µm), a phase grating (nickel, period \(p=3.24\,\)µm, height \(h=4\,\)µm), and an analyser grating (gold, period \(p=4.28\,\)µm, height \(h=45\,\)µm). Different equipment in order to monitor physiological functions like breathing, heartbeat, and body temperature are implemented into the setup. The gantry system features a direct anode tungsten target X-ray tube (RTW, MCBM 65B-50 W) with a focal spot size of \(50\,\)µm \(\times \, 50\,\)µm, a Hamamatsu flat panel detector (C9312SK-06) with a gadolinium oxysulfide (GOS) scintillator and a pixel size of \(50\,\)µm \(\times \, 50\,\)µm. Due to magnification, the effective pixel size in the sample plane accounts to \(29\,\)µm \(\times \, 29\,\)µm. There was no filter in the beam.
During image acquisition the mice remained in supine position. Images were acquired using four stepping positions with an exposure time of 5 s per position. Reference images were acquired with the sample removed from the beam. The source was operated at 35 kVp and 20 W. The deposited dose during X-ray exposure results in \(1.5\,\)mGy. Subsequently, the images were processed by using an in-house Python script to calculate all three modalities from the images acquired during the phase-stepping procedure. A flow-chart of this study is shown in Supplementary Fig. 1.
Quantitative image analysis
For quantitative signal analysis of the conventional absorption and the dark-field signal two masks were segmented for each mouse and measurement. Transplanted and native lung masks were segmented individually. The recipients’ native lungs, that did not undergo transplantation, served as control lungs in this study. The segmentation of the masks was performed by experienced radiologists (K.H., L.A.) on the basis of conventional absorption images using the software MATLAB. The masks included the free accessible lung parenchyma without the overlaying mediastinum and heart or the diaphragm. In order to increase the classification accuracy, osseous structures such as the ribs and the spine were excluded from the masks as well. The ribs and the spine were segmented automatically using binary erosion and dilation on pre-smoothed absorption images. An example for the choice of the ROIs is shown in Supplementary Fig. 2. A pixel per pixel comparison between absorption and dark-field images is possible as they result from the same exposure. The mean signal for the ROI within the mask was calculated.
Qualitative image analysis
All images were assessed separately for the presence or absence of bronchial pathologies by two experienced lung radiologists (K.H., J.D.).
Statistical analysis
To compare the dark-field and absorption signal intensities of the transplanted and control lungs, means and standard deviations of the signals were calculated. Means were tested for statistical significance using Student t-test for paired samples.
References
Khush, K. K. et al. The international thoracic organ transplant registry of the international society for heart and lung transplantation: Thirty-sixth adult heart transplantation report-2019; focus theme: Donor and recipient size match. J. Heart Lung Transpl. 38, 1056–1066 (2019).
Santacruz, J. F. & Mehta, A. C. Airway complications and management after lung transplantation: Ischemia, dehiscence, and stenosis. Proc. Am. Thorac. Soc. 6, 79–93 (2009).
Krishnam, M. S. et al. Postoperative complications of lung transplantation: Radiologic findings along a time continuum. Radiographics 27, 957–974 (2007).
Mahajan, A. K. et al. The diagnosis and management of airway complications following lung transplantation. Chest 152, 627–638 (2017).
Samano, M. et al. Bronchial complications following lung transplantation. In Transplantation Proceedings, vol. 41, 921–926 (Elsevier, Amsterdam, , 2009).
Frye, L. & Machuzak, M. Airway complications after lung transplantation. Clin. Chest Med. 38, 693–706 (2017).
Pfeiffer, F., Weitkamp, T., Bunk, O. & David, C. Phase retrieval and differential phase-contrast imaging with low-brilliance x-ray sources. Nat. Phys. 2, 258–261 (2006).
Pfeiffer, F. et al. Hard-x-ray dark-field imaging using a grating interferometer. Nat. Mater. 7, 134–137 (2008).
Hellbach, K. et al. In vivo dark-field radiography for early diagnosis and staging of pulmonary emphysema. Investig. Radiol. 50, 430–435 (2015).
Hellbach, K. et al. Facilitated diagnosis of pneumothoraces in newborn mice using x-ray dark-field radiography. Investig. Radiol. 51, 597–601 (2016).
Yaroshenko, A. et al. Improved in vivo assessment of pulmonary fibrosis in mice using x-ray dark-field radiography. Sci. Rep. 5, 17492 (2015).
Scherer, K. et al. X-ray dark-field radiography-in-vivo diagnosis of lung cancer in mice. Sci. Rep. 7, 1–9 (2017).
Bech, M. et al. In-vivo dark-field and phase-contrast x-ray imaging. Sci. Rep. 3, 3209 (2013).
Kim, S. Y. et al. Critical care after lung transplantation. Acute Crit. Care 33, 206 (2018).
Shofer, S. et al. Significance of and risk factors for the development of central airway stenosis after lung transplantation. Am. J. Transpl. 13, 383–389 (2013).
Semple, T., Calder, A., Owens, C. & Padley, S. Current and future approaches to large airways imaging in adults and children. Clin. Radiol. 72, 356–374 (2017).
Prop, J., Ehrie, M., Crapo, J., Nieuwenhuis, P. & Wildevuur, C. R. Reimplantation response in isografted rat lungs: Analysis of causal factors. J. Thorac. Cardiovasc. Surg. 87, 702–711 (1984).
Khan, S. U. et al. Acute pulmonary edema after lung transplantation: The pulmonary reimplantation response. Chest 116, 187–194 (1999).
Reis, A., Giaid, A., Serrick, C. & Shennib, H. Improved outcome of rat lung transplantation with modification of the nonsuture external cuff technique. J. Heart Lung Transpl. 14, 274–279 (1995).
Reece, T. B. et al. Native lung volume reduction surgery relieves functional graft compression after single-lung transplantation for chronic obstructive pulmonary disease. J. Thorac. Cardiovasc. Surg. 135, 931–937 (2008).
Mizobuchi, T., Sekine, Y., Yasufuku, K., Fujisawa, T. & Wilkes, D. S. Comparison of surgical procedures for vascular and airway anastomoses that utilize a modified–non-suture external cuff technique for experimental lung transplantation in rats. J. Heart Lung Transpl. 23, 889–893 (2004).
Gromann, L. B. et al. In-vivo x-ray dark-field chest radiography of a pig. Sci. Rep. 7, 1–7 (2017).
Hellbach, K. et al. Depiction of pneumothoraces in a large animal model using x-ray dark-field radiography. Sci. Rep. 8, 1–8 (2018).
Willer, K. et al. X-ray dark-field imaging of the human lung—A feasibility study on a deceased body. PLoS ONE 13, e0204565 (2018).
Fingerle, A. A. et al. Imaging features in post-mortem x-ray dark-field chest radiographs and correlation with conventional x-ray and ct. Eur. Radiol. Exp. 3, 25 (2019).
Smirnova, N. F. et al. Inhibition of b cell-dependent lymphoid follicle formation prevents lymphocytic bronchiolitis after lung transplantation. JCI Insight 4(3), e123971 (2019).
Tapfer, A. et al. Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography. Med. Phys. 38, 5910–5915 (2011).
Tapfer, A. et al. Experimental results from a preclinical x-ray phase-contrast ct scanner. Proc. Natl. Acad. Sci. 109, 15691–15696 (2012).
Acknowledgements
We acknowledge Natalia F. Smirnova for providing murine LTx transplanted mice used for this study. We acknowledge financial support through the European Research Council (AdG 695045). This work was carried out with the support of the Karlsruhe Nano Micro Facility (KNMF, www.kit.edu/knmf), a Helmholtz Research Infrastructure at Karlsruhe Institute of Technology (KIT).
Funding
Open Access funding enabled and organized by Projekt DEAL.
Author information
Authors and Affiliations
Contributions
A.Ö.Y., F.P., J.D., J.H., M.F.R., and K.H. conceived the experiments, S.U. and C.M. conducted the experiments, S.U., L.A., and K.H. analysed the results. K.H. and J.D. assessed for the presence or absence of bronchial pathologies. K.H., S.U., and C.M. wrote the manuscript. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.