Introduction

As part of the investigation of innate immune defences in C. elegans, worms are generally wounded in one of two ways. For precise cell-biological studies, individual worms mounted on glass slides can be injured using a laser coupled with an inverted microscope. As a complementary method, worms can be wounded manually, using standard glass microinjection needles1. Both techniques are time-consuming and require meticulousness. More than 20 years ago, a method for genetically transforming nematodes using arrays of silicon micromechanical piercing structures was published2,3. This inspired us to investigate the possible use of such silicon arrays as a tool to wound C. elegans in a relatively uniform but less painstaking manner.

Silicon is the most widely used material in the microelectronics industry and in the production of micro-electromechanical systems. It is abundant, inexpensive and mechanically robust4. High-quality silicon wafers are available commercially and fabrication processes for silicon features have been developed for more than 50 years5. Silicon microstructures have been already successfully used for piercing of biological objects2 and for the fabrication of microneedles6 for gene and drug delivery7. These studies have shown that silicon is a chemically and mechanically stable biocompatible material. Despite the apparent simplicity of the method described by Trimmer and colleagues2, there appears to be no other study using these arrays to transform any nematode species. On the other hand, such arrays could be well-suited for use as tools to wound worms8. Unfortunately, neither the arrays nor a protocol for their fabrication are available any more (W. Trimmer, personal communication). In order to fabricate equivalent microstructures, we therefore developed our own protocol, based on optical lithography and alkaline wet etching.

Materials and Methods

Array production

As initial material, we used n-type monocrystalline silicon wafers doped by phosphorus (5–10 Ω cm) oriented with [100] as the surface plane (from Sil’tronix, France). The wafers were polished on both sides and covered with a 290 nm-thick thermally grown oxide layer. We used two sizes of wafers with diameters of 1 inch (25.4 ± 0.3 mm) and 4 inches (100 ± 0.3 mm).

All the microfabrication processes were carried out in a clean room of air purity class ISO 6. The wafers were cleaned in successive baths of acetone and isopropyl alcohol (IPA) with ultrasonic agitation, then rinsed with deionized water and dried under a clean nitrogen flow. In order to improve the adhesion of the photoresist and to remove the traces of organic solvents and humidity, the wafers were exposed to oxygen plasma at a temperature of 150 °C for 10 minutes in a plasma chamber (Nanoplas, France). The radiofrequency power for plasma excitation was 200W. Then, the wafers were spin-coated with a positive photoresist (Microposit S1813 from MicroChem) and exposed to UV-light using MJB-4 (Süss MicroTec, Germany) or PLA-501 (Canon, Japan) optical lithography tools through a mask of round features.

We studied two types of arrays using masks with different geometries: hexagonal and square arrays. The hexagonal arrays were denser than the square ones, but in both cases we kept the distance between the features large enough in order to prevent possible proximity effects. During the lithography step, we usually oriented the x-axis of the arrays along the [110] silicon crystalline axis in order to cut the samples in between the features during the silicon cleavage; the orientation should not affect the final shape of individual microfeatures9.

The feature diameters were 75, 100 and 300 μm and the center-to-center distances were 100, 133 and 400 μm respectively in the hexagonal arrays. The mask designs for the 75 and 100 μm feature arrays are shown in Supplementary Fig. S1. For square arrays, we used only 300 μm features with 400 and 600 μm center-to-center distances (pitch). After UV light exposure the features were developed in a commercially available solution (Microposit MF-319) containing tetramethylammonium hydroxide (TMAH). The thickness of the deposited photoresist was about 1.4 μm and it was monitored by a mechanical contact profilometer (Dektak, Bruker).

The features were transferred from the resist layer to silicon dioxide by reactive ion etching (MG-200, Plassys, France). The silicon dioxide was completely removed from the topside of the wafers in the areas between the features that were protected by photoresist. We used CHF3 reactive plasma because of its good selectivity in etching of SiO2, silicon and the photoresist polymer10. The remaining photoresist was removed in a solution of 1165 (from Microposit) containing N-methyl-2-pyrrolidone. We confirmed complete removal of the oxide layer in the areas between the round features by contact profilometry. Finally, several wafers were directly processed by alkaline solution while the other wafers were cut in 1 cm x 1 cm square pieces along [110] the crystalline directions of the silicon crystal using a diamond scriber.

Each sample was exposed to potassium hydroxide (KOH) solution in order to etch silicon in the areas not protected by the SiO2 hard mask. Wet chemical attack by hydroxide solutions is known to be anisotropic because KOH etches different crystalline planes with significantly different rates11. We chose a relatively high KOH concentration of 45% (in deionized water; Fluka) because the resulting surface quality is known to be better for highly concentrated solutions (see page 40 in Fruhauf et al.5). In several experimental series, we also saturated the solution by addition of isopropanol (IPA) or ethanol.

A borosilicate glass beaker containing the etching solution was placed into a water bath on a regulated hotplate. The etching solution was kept at a fixed temperature during the etching in order to control the shape of the obtained features, which was also influenced by the etching time. The temperature was measured by a thermometer immersed in the KOH solution. We developed a series of custom designed magnetic 3-D printed sample holders allowing constant uniform agitation for the samples of different sizes and shapes12. The samples were fixed on the magnetic holders fabricated from a temperature resistant photopolymer plastic resin (Formlabs High Temp Resin) and then immersed in the etching solution. Before their first use, the sample holders were rinsed in a hot KOH solution for at least one hour, to remove polymer residues that otherwise interfered with alkaline etching. The samples were agitated at high speed in hot alkaline solution on a standard bench-top magnetic stirrer in order to homogenize the etching and to disperse hydrogen bubbles that appear during the chemical reaction of silicon with hydroxide ions11. It was possible to install up to four small samples onto the holders (Fig. 1) and to process them in the same etching run. The samples could be then extracted one by one after the desired etching times. The 4 inch wafers were processed one-by-one. In order to keep the most stable conditions, we used the same quantity of KOH (650–750 ml) in the beaker and we changed the solution regularly to prevent the alteration of its composition through the introduction of chemical reaction products and by evaporation.

Figure 1
figure 1

Drawing of a sample holder used for homogeneous KOH etching of multiple one-inch wafers (Autodesk 123 Design software). (a) Main support with magnets; (b) Arms for easy removal from etching solution; (c) One-inch (2.54 cm) diameter wafer to be etched.

The typical etching time in KOH solution depended on the feature size. For the 75 μm feature arrays it was between 50–60 minutes and for 300 μm feature arrays, about 90 minutes at 65 °C. After the etching, the samples were rinsed in deionized water in order to stop the reaction, then dried under clean nitrogen and observed by optical and scanning electron microscopy (SEM). The optical microscopy gives an immediate evaluation of the etching homogeneity and microscopic defects present on the sample surface. Moreover, the feature base size, the undercut depth and the presence of any remaining SiO2 mask can also be estimated from optical microscopy. In order to measure the size and characterize the shape of pyramids, however, we needed to use SEM and to tilt the samples from normal incidence to angles from 40 to 70°. For SEM observation we used a tungsten-filament JEOL JSM-5910 microscope with a typical electron acceleration voltage of 20–30 kV.

After the observations, samples could be returned to the KOH solution in order to continue the etching to obtain the desired pin shape of the features. To avoid the risk of over-etching, samples that were almost finished could be placed into a ultrasonic bath (LEO-801 Bioblock Scientific, Illkirch, France) for 5–10 minutes in order to obtain sharp features by mechanical breaking of the remaining silicon at the top of the pin tip. Removal was effective provided that the junction between the two parts was of the order of 2 μm thick. Wider junctions required longer periods of ultrasound treatment to break and this was associated with a fracturing of the apex of the pyramidal structure.

Worm methods

The strains IG2741 and IG106113 carrying the frIs7 (nlp-29p::GFP; col-12p::DsRed2) integrated array in the wild-type or sta-2(ok1860) background, respectively, were cultured under standard conditions, i.e. on E. coli OP50 on NGM agar plates14. Wounding with a micro-injection needle was performed as previously described15. For experiments using the silicon arrays, the wafers were mounted either on plastic handles using a cyanoacrylate adhesive ("superglue”) or on the end of syringe plungers, using household double-sided adhesive tape. Synchronized populations of young adult worms, obtained by alkaline hypochlorite treatment14, were transferred to plates without bacteria, rapidly wounded by bringing the wafer down with gentle pressure, repeatedly in a tiling fashion to cover the surface of the plate before transfer to a fresh OP50-seeded plate. In both cases, upregulation of nlp-29p::GFP reporter gene levels were quantified after 6 hours with the COPAS Biosort (Union Biometrica)15. Adult worms were stained with Hoechst 33258 as previously described16, and with DAPI (2.5 μg/ml in 0.5 mM levamisole) for 15 minutes at room temperature, with agitation, followed by 3 washes with 50 mM NaCl.

Electron microscopy

Worms were fixed in 2% glutaraldehyde in 0.12 M phosphate buffer overnight. They were postfixed in 1% osmium in distilled water for 30 minutes. Dehydration in a graded ethanol series preceded drying from liquid carbon dioxide by the critical point method. The worms were then gently transferred to a carbon-taped stub for gold sputtering (10′’ at 15mA, Edwards). Imaging was carried out on an FEI Teneo VS running in high vacuum mode, at 5 kV and using an ETD secondary electron detector.

Results

Array microfabrication

In order to obtain an initial estimate of the required etching time and the final shape of the pins, we modelled the etching process using ACES software17, taking the data from Seidel et al.18. We simulated different mask shapes including circles and squares (see Supplementary Fig. S2) and we chose the former in order to simplify process optimization and to get closest to the desired final pin shape. The round features with initial mask diameters of 75, 100 and 300 μm were organized in arrays with separation distances sufficient for pyramid pin development. The pin density, i.e. the center-to-center pin distance, was chosen to be small enough to wound young adult C. elegans that are typically about 1 mm in length.

When wafers were removed at intervals from the KOH solution, the successive steps of etching for typical individual silicon pyramids, using a hexagonal mask with the pitch of 100 μm and initial feature diameter of 75 μm, could be followed using SEM (Fig. 2a–c). This was straightforward as they required no preparation or treatment before imaging. After 100 minutes of etching, one can clearly see the pyramid with an octagonal trunk, resulting from undercutting of silicon under the SiO2 mask, with a lateral size of about 30 μm, corresponding to the pyramid base, and 16 μm corresponding to the pyramid top. The remaining SiO2 mask is clearly visible on the top of the pyramid (Fig. 2a). After 110 minutes of alkaline etching, one can see that the under-etching is deeper and the lateral sizes of both base and top of the pyramid are decreased to 25 and 5.5 μm, respectively (Fig. 2b). Finally, after etching in the same solution for a total time of 118 minutes, the remaining pyramid has a base size of 21 μm and a very sharp tip. This form most closely resembles the pins previously described2 (see Supplementary Fig. S3). Overall, the selectivity in the etching of Si and SiO2 was very high, and the oxide mask protected the silicon from alkaline attack relatively well (Fig. 2a–c). KOH solution attacks (100) Si planes and, because of the strong undercut, the thin 290 nm-thick SiO2 layer remained only in an area with a size of 5–7μm. For some pyramids, we observed complete removal of the SiO2 protection, but in general, the etching was very homogeneous when we used our custom-designed 3D-printed rotating sample holder (Fig. 1) at speeds of 100 to 180 rpm. In earlier work, the crystalline planes that form the pyramid pins were identified as (411)3,6,19. These crystal planes give a tetragonal tip similar to those observed for Si etching in Triton X-100 supplemented TMAH20. In our case, the tips of the pins are octagonal with the shapes similar to those reported by Wilke et al.9,21. Those authors identified the crystal planes forming the main sharp part of pyramids as belonging to (312) family, while the crystalline planes of the base were identified as (228)21. In order to ensure scalability of the process, we compared the shape of the pyramids obtained using 75 and 100 μm masks and found that the angles of the tips were similar; only the pin base size and height changed (see Supplementary Fig. S4). On the other hand, the shape of the tips was dependent on the etching bath conditions, in particular on the freshness of the KOH solution. Aging of the solution favored the formation of flat pyramid bases, consistent with previous observations21. The addition of ethanol, Triton X-100 or IPA also favored the formation of pyramids without sharp tips. The addition of IPA, for example, stabilized the etching process. Thus pyramid surfaces were very smooth without defects, but pyramids were formed by only their bases (see Supplementary Fig. S5). In this case also, the crystal planes forming the pyramids correspond to those previously described21. On the basis of these results, for subsequent etchings, we used baths of fresh aqueous KOH solution, without additives, for each series of samples to obtain the optimal shape of the pyramidal pins and to diminish the base development. We also increased the etching temperature because higher temperatures allowed us to decrease the etching time which was otherwise inconveniently long for the arrays with initial sizes of 100 and 300 μm. For 75 μm arrays the typical etching time was about 45 minutes for standard etching temperatures of 70–72° to obtain sharp tips (see Supplementary Fig. S6a–c). Once the SiO2 protection was gone, sharp pyramids were rapidly attacked by KOH. Their height as well as width diminished and when over-etched, only the more resistant crystalline planes close to the base remained (see Supplementary Fig. S6d). This instability made the etching process very time-sensitive. We therefore etched samples in KOH for a time slightly inferior to that expected for complete SiO2 removal, then examined the features using SEM. If necessary we then returned the sample to the KOH solution to finish the process. Because of the consumption of all the silicon under the SiO2 mask, the protective “hat” part was readily removed when the wafer was rinsed under a flow of deionized water at the end of the etching process. When the pyramid tip size approached 2–5 μm, it was also possible to finish the fabrication by mechanical breaking of the remaining “hat” in a pure water ultrasound bath. In both cases, the remaining pyramids had very sharp tips. Although requiring precision, by standardising the different steps of the procedure, we were able to make large arrays of regularly structured pyramidal pins (Fig. 2d) in a routine and reproducible manner.

Figure 2
figure 2

Silicon pyramids in a 75 μm array etched in fresh 45 % KOH solution at T=63 °C, sample holder rotation speed 170 r.p.m for 100 minutes (a), 110 minutes (b), 114 minutes, followed by an additional 4 minutes, after removal and inspection with a stereomicroscope (c). The 3 images are at the same magnification. (d) Large array of homogeneous pins at the end of the etching period. Of the 342 pins in this electron photomicrograph, 130 retain the "hat” that is subsequently removed in a pure water ultrasound bath. Manufacturing parameters: 75 μm array; 750 ml fresh 45 % KOH; T=72 °C; 100 rpm. All the samples were tilted in the SEM at 70°.

Efficient wounding of C. elegans

To make handling of the arrays easier, they were adhered to a short plastic rod or on the end of syringe plungers. To wound young adult C. elegans, an array was brought down gently onto a synchronised population of worms on an agar plate. The array was lifted, moved and brought down again. The light pattern of indentations left on the surface of the agar was used to ensure complete coverage of the population. Signs of wounding were visible through a dissecting microscope. These ranged from the type of small hernia-like extrusions often seen with needle-wounds, through more extensive loss of internal content (see Supplementary Fig. S7), to immobility and complete loss of normal body structure. In a typical experiment, more than two thirds (67.3%) of the worms (n = 584) were fully motile 4 hours after wounding. One of the consequences of wounding or fungal infection of the C. elegans epidermis is the rapid induction of antimicrobial peptide (AMP) gene expression. This can be monitored through the use of transgenic worms carrying fluorescent reporter genes. The most extensively characterised strain, IG274, carries the integrated transgene frIs7, with 2 reporter genes, dsRed and GFP under the control of a constitutive epidermal promoter, col-12, and the infection-inducible nlp-29 promoter, respectively. In the absence of pathogens or injury, IG274 worms appear red, but express GFP strongly when wounded or infected. These changes can be monitored visually or quantified using the COPAS Biosort1. We compared the induction of nlp-29p::GFP provoked by wounding by hand with a glass needle or with the silicon pin arrays. As expected, manual wounding with a microinjection needle caused a substantial increase in average GFP expression, and this was almost completely abrogated in a sta-2 mutant, consistent with previous observations13. There was an even more marked increase when worms, whether at a lower or higher density on the culture plate, were wounded with a silicon array. Again, this response was dependent upon sta-2 (Fig. 3a), consistent with both methods activating AMP gene expression by the same canonical signal transduction pathway. Importantly, in addition to producing equivalent results as the standard needle method, the use of the array simplified and accelerated the procedure substantially. An experienced researcher with good manual dexterity can reasonably wound one worm every 2–4 seconds. With the arrays, no training was required and the speed of wounding was increased 10–50 fold, as hundreds of worms could be wounded in less than 30 seconds. Consistent with the fact that the arrays pierced the collagen-rich cuticle that renders C. elegans impermeable to most compounds22, we observed extensive staining of epidermal nuclei with dyes that under normal culture conditions, in non-molting animals, only stain the nuclei of intestinal cells23 (Fig. 3b). In severely wounded worms, germline staining was often apparent. Among worms without marked tissue extrusion, in only a very small proportion (3.6%, n = 83) was germline nuclear staining observed (see Supplementary Fig. S8). Having established the potential utility of the arrays, we went on to evaluate the efficiency of wounding using pins of different sizes, spacing and geometries. While the average fluorescence ratio was greater when the pins were longer, the geometry did not appear to be critical (Fig. 4). We found that we could use the arrays multiple times. Even after repeated use, we observed little abrasion of the pin apex (see Supplementary Fig. S9). When 6 hours after wounding, we examined normally moving worms that strongly expressed the nlp-29p::GFP reporter, with rare exceptions, these worms displayed only minor tissue damage, as judged by light microscopy (see Supplementary Fig. S10). Through SEM, we characterised in more detail some of these animals. We observed a range of lesions, typically of the order of 5 μm in size. In all cases (n  > 20), it appeared that material had been extruded from inside the worm. In addition to amorphous extrusions, there were often diaphanous folds (Fig. 5; see Supplementary Fig. S11), which we take to be damaged cuticle.

Figure 3
figure 3

Efficient wounding of C. elegans with a silicon array. (a) Quantification of the change of reporter gene expression provoked by wounding with a needle (5 left-hand columns), or arrays, worms carrying frIs7 in the wild-type or sta-2 mutant background (circles and triangles, respectively). The fluorescence ratio (Green/TOF in arbitrary but constant units) is shown for the indicated number of worms for each condition (n). The bars indicate the means. (b) Representative images of control (top) and wounded (bottom) adult wild-type worms stained with Hoechst 33258. In the control animals, only staining of the intestinal nuclei is apparent (arrows), while in the array-wounded worms nuclei in the epidermis (arrows) are also stained.

Figure 4
figure 4

Wounding of C. elegans with different silicon arrays. (a) Top row shows SEM images of 3 different arrays (left to right: H75-42, H100-9, H75-46). Note that, as indicated, the magnification is not the same for all 3, hence the scale bars are different too. The other 2 rows are GFP (middle row) or mixed GFP/dsRed fluorescence signals for representative groups of worms carrying frIs7 picked because they appeared to have a normal morphology (i.e. were not badly wounded) after treatment with the indicated array, compared to non-wounded controls (left-hand column). (b) Quantification of the change of reporter gene expression provoked by wounding with the 3 arrays, in the same order as in a, in worms carrying frIs7. Details are as in the previous figure.

Figure 5
figure 5

Wounds inflicted on C. elegans by silicon arrays. (a) SEM images of an adult hermaphrodite worm that showed normal movement and overall morphology and had strong nlp-29p::GFP reporter gene expression 6 hours after wounding. The worm has at least 2 lesions (boxed in yellow). These are shown at higher magnification in (b,c). In common with many lesions, the extruded material was found covered in bacteria. Two further wounds from a different worm are also shown (d,e). Scale bars, 100, 5, 2, 1, 1 micron, (a-e).

Discussion

Using an alkaline etching technique, we produced arrays of silicon pyramidal pins. Contrary to the fabrication of concave features on Si (100) which is usually self-limiting when the slowly etched (111) surfaces are reached, the fabrication of convex features on Si (100) by alkaline etching is more challenging5. Two processes occur at the same time: etching of the (100) crystalline surface directed towards the wafer depth in the areas that are not protected by a mask and undercutting of silicon features in a lateral direction under the mask despite the protection. The final shape of the obtained features depends on the difference in the rates of these two processes24. For example, the etching rate for (111) silicon crystalline planes is more than 100 times slower than for the other planes such as (100)25,26, and it is possible to obtain sharp features with a pyramidal shape both for (100) and (111) oriented wafers20. Numerous models have been proposed to explain the convex corner undercutting25 and its compensation26 and, more generally, anisotropic etching of silicon27. The main complexity in the description of experimental procedures arises from the fact that multiple parameters have been reported to affect the undercutting rate: the solution temperature5, KOH or TMAH concentration, freshness of the alkaline solution21 as well as the introduction of different chemical additives to the solutions such as I2/KI28, the surfactant Triton-X-10020,29 or IPA5. In our fabrication process, we used only fresh aqueous KOH solution baths for each sample series and we optimized the shape of the pyramidal pins to be suitable for biological experiments. Only etching in pure KOH solutions allowed us to obtain sharp pyramids. Addition of ethyl or isopropyl alcohol or Triton to aqueous KOH solutions favoured the formation of crystal planes forming flat pyramids. We developed a series of sample holders for the wafers of different sizes from 1cm2 up to 10 cm in diameter, resistant to KOH and alcohol solutions up to the temperatures of more than 80 °C necessary to ensure homogeneous etching over large surfaces. Very sharp pyramidal needles were organized into arrays with a pitch of 100–133 μm, dense enough to wound young adult C. elegans hermaphrodites that are around 1 mm in length (Fig. 6).

Figure 6
figure 6

Artificial montage to illustrate the relative sizes of C. elegans and pins, with adult hermaphrodite worms fixed for EM placed directly on silicon pyramids in 100 μm (a) and 75 μm (b) arrays. Scale bars, 50 and 20 micron, (a,b).

In the original publication, piercing structures similar to the ones described here were claimed to have been used to transform the entomopathogenic nematode Heterorhabditis bacteriophora in an extremely rapid and efficient manner2. Despite the obvious attraction for such a simple method, no other publication has ever reported the successful replication of this work. Parasitic nematodes are notoriously difficult to transform, compared to C. elegans for which micro-injection-based transformation is a standard laboratory technique. In our hands, we were unable to obtain any evidence for transformation of C. elegans using our silicon pin arrays. Neither more than 30 trials replicating the conditions used previously2, nor more than 150 trials combining array-mediated wounding followed by electroporation using hygromycin resistance as a method of selection yielded any transgenic worms (JB and CC, unpublished; full details available upon request). Thus, unfortunately, it appears that their utility for making transgenic nematodes is limited at best. On the other hand, these arrays enormously accelerate and simplify the generation of large populations of wounded C. elegans. This opens up the potential for generating samples in a sufficient volume to allow transciptomic, proteomic or metabolomic analyses of the response to wounding, further strengthening the utility of C. elegans in this domain30,31.