Introduction

Ion-exchange chromatography has been successfully used to separate radioisotopes for medical applications, nuclear fuel reprocessing and other applications1,2. However in many instances the ion-exchange material lacks desired selectivity. Current methods of separation rely on commercially available ion-exchange resins that preferentially bind the element based on charge3. Extraction chromatography methods have been developed for some separations4, but the extraction chromatography resins sometime have slow flow rates, and the extractant can be eluted. Often the process to purify a radioisotope requires the use of multiple columns and result in consuming more time and labor. Chemical separations used in accelerator isotope production process at Brookhaven National Lab (BNL) present interesting challenges. The target masses for production scale targets irradiated at BNL are over 50 grams, and the mass of the radioisotopes produced is less than 0.0001 grams5,6. The separation presents challenges if no ion exchange resins are available that have more selective for the isotope of interest rather than the target material.

Production of 225Ac has been of particular interest recently since efficacy of this material has been demonstrated in a treatment of certain types of cancer. 225Ac can be made available by several routes: separation from 229Th/225Ra generator, by high energy (100–200 MeV) proton irradiation of natural Thorium target, or by irradiation 226Ra target with low energy proton (10–24 MeV)7,8. Chemical separation of 225Ac from thorium irradiated with high energy protons is especially challenging. The irradiation results in fission of the thorium in the target and, in addition to 225Ac, produces a variety of potentially useful radionuclides such as 111Ag, 105Rh, 140La, Ra isotopes, and 140Ba. As previously mentioned, 225Ac (t1/2 = 9.9 days) and its daughter; 213Bi (t1/2 = 45 min) are emerging as important isotope for targeted alpha therapy9,10,11. Other isotopes in the list can be used for beta therapy (111Ag, 105Rh, and 140La), or as a parent in medical isotope generators, for example Radium isotopes and 140Ba.

The use of inorganic ion-exchange materials which selectivity stems from the crystal structure of the ion-exchanger could provide a more attractive mode of separation. Crystalline silicotitanate (CST) and the poorly crystalline CST (PCST) have been synthesized hydrothermally in alkaline media12. The reduced crystallinity was obtained by either shortening the reaction time at the same synthesis temperature for CST (200 °C) or reducing the temperature to 170 °C and changing the hydrothermal reaction time. The CST inorganic ion exchangers were initially developed in the 1960s and have been evaluated for nuclear waste treatment due to the materials remarkable selectivity toward Cs and Sr13,14,15. Studies showed that Cs and Sr2+ cations demonstrate higher rate of uptake by poorly crystalline CST compared to the crystalline form. This was attributed to the higher surface area and smaller particle size, which was highlighted to account for the increased rate even though there would be otherwise slow diffusion through the channels. The high selectivity of CST ion exchanger for Cs and Sr was used to decontaminate the Fukushima site16.

Titanium-based ion exchange materials have been demonstrated to be selective for strontium and actinides in highly alkaline environments17. The studies reported herein seek to synthesize, characterize, and evaluate PCST inorganic ion exchanger in the separation process of 225Ac from irradiated Th target. During the accelerator production of 225Ac from a 232Th target 227Ac and the daughters of 227Ac are coproduced18. The daughters of 227Ac (227Th and 223Ra) can be separated from 225Ac during the purification process19. However after purification the 227Ac would grow in and reduce the purity of 225Ac18. Various literature studies to purify 225Ac from Thorium and/or radium have focused on organic cation or anion ion exchange resins1,2. The PCST ion exchanger has been synthesized and evaluated for the removal of Sr, Cs and other isotopes from waste streams20. In this manuscript the purification of 225Ac from 227Th and 223Ra with PCST ion exchanger was developed. The utility of the purification process was evaluated in the following applications: 225Ac production from proton irradiated Th or Ra, 225Ac produced from the 229Th/225Ra generator, and to purify 225Ac from the daughters of 227Ac.

Results

Inorganic ion-exchangers were synthesized by hydrothermal synthesis, purified and the phases were confirmed by comparing XRD patterns to published results20. Figure 1 outlines the study design to evaluate the inorganic ion exchangers. Initially, ion-exchange properties of the synthesized materials were evaluated by the batch method, and distribution coefficients (Kd) were determined for 225Ac and Th. Subsequent studies determined the Kd of several elements (Th, La, Ce, Rh, Ag, and Ba) on PCST ion exchanger. Optimal conditions for the separation on PCST inorganic ion-exchanger were evaluated with a representative sample containing 225Ac, 227Th, and 223Ra. Capacity studies were performed with barium and thorium on PCST to determine if the ion exchanger could be used for radium (0.3 g) and/or thorium (50–100 g) production targets. The stability of the PCST ion exchanger was determined in: ammonium acetate buffer from pH 5 to 1, hydrochloric or nitric acid at 0.1,1, 2 and 3 M.

Figure 1
figure 1

Flow chart illustrating the sequence of studies reported in the manuscript.

Evaluation of inorganic Ion-Exchanger Selectivity

The evaluation of the selectivity of poorly crystalline silicotitanate (PCST) for Rh, Ba, La, Ce, Th, and Ag were performed with batch studies, and the data for Th, Ag, and Ba are presented in Fig. 2. The results of the PCST ion exchanger show an insignificant selectively at low pH for Ba, La, Ce, Th and Rh, with a higher selectivity for Ag (3465 ml/g) at a pH of 1. As the pH goes from 1 to 5 the PCST ion exchanger increases selectivity for Ba, and Ag (46305 ml/g, 6796 ml/g respectively). The PCST ion exchanger had low selectivity for Ce, La and Rh (100 ml/g, 71 ml/g and 85 ml/g respectively). The distribution coefficients for the trivalent cations Ce and La increased as the pH went 1 to 5.

Figure 2
figure 2

Distribution coefficients (Kd) of Ba, Th, and Ag on PCST ion exchanger at pH values from 1 to 5 in 0.5 M ammonium acetate. La, Ce, and Rh had Kd values less than 100 mg/L.

Column studies

To increase the flow rates buffer was added to the 100–200 mesh PCST material and the solution was decanted. This was able to remove fine particles of PCST material, and the flow rates increased to 0.25–1 ml/min.

PCST breakdown study

The quantification limit for Ti on the ICP-OES was defined by analysis of diluted standards and the acceptance criteria for the true concentration value and the % RSD was within 10%. The quantification limit for Ti by ICP-OES was determined to be 0.005 ppm. ICP-OES analysis of all samples indicated Ti breakthrough (Fig. 3). The Ti breakthrough was lowest in 0.5 M ammonium acetate pH 5 with 0.05–6 µg of Ti present in the load, 0.5 M ammonium acetate pH 5 and 3 rinses. Rinsing the PCST material with ammonium acetate at pH 1 resulted in 352–405 µg of Ti. In subsequent rinses with 0.1 M HCl or nitric acid the PCST material showed a slight higher amount of Ti breakthrough in HCl (91–110 µg) versus nitric acid (63–86 µg). Higher concentrations of acid resulted in more breakthrough of the Ti from the PCST with 1 M (480–700 µg Ti per fraction) 2 M (750–1022 µg Ti per fraction) and 3 M (703–1135 µg Ti per fraction). In all elutions with HCl or nitric acid breakthrough of the Ti from the PCST material was higher for HCl.

Figure 3
figure 3

Acid study examining the breakdown of PCST in the presence of various concentrations of 0.5 M ammonium acetate and hydrochloric or nitric acid. 10 mL (20 bed volumes) was used for the 0.5 M ammonium acetate load and rinse steps then each acid concentration was rinsed with 4 × 3 mL rinses.

Separations of Th, 225Ac and other metals

In summary the Kd data indicated: the PCST ion exchanged has favorable properties to capture Thorium at pH values of 1 to 2 while 225Ac would be less favorable; the resin has high affinity for Ba at pH values of 3 to 5, and is more selective for Ag at pH values of 1, 4 or 5 than Th, La, Ce, and Rh. A column of PCST ion exchanger was used to capture Thorium and barium from a solution containing Th, Ba, 225Ac, Rh, La, Ag, and Ce in 0.5 M NaOAc at pH 2 (see Supplementary Fig. S4). The eluted solution contained 95% of Ac, 90% of Ce, 73% of La and 77% of Rh. The data indicates 15% of La, 5.8% of Rh, and Th, Ag and Ba were totally absorbed and retained on the PCST column. The absorbed metals except Ag were recovered from the PCST column using 3 M nitric acid solution. The capacity of the PCST inorganic ion exchange materials for Barium and 232Th was determined to be 24.19 mg/mL for Barium and 5.05 mg/mL for Thorium.

Ba and La column studies

The PCST ion exchanger was able to retain Ba in 0.5 M ammonium acetate at pH 5 while eluting La (see Supplementary Fig. S2). Combining the load and rinse 1–3 provided 85% recovery of La while only 0.15% of the Ba was present. Rinse solutions 4–5 and elution solutions 1–2 recovered 99.8% of the barium with 92.8% of the barium eluting in 0.5 M ammonium acetate at pH 1.

223Ra, 225Ac, 227Th studies

pH study & PCST breakdown: A study was performed with PCST material with 225Ac, 223Ra and 227Th in 0.5 M ammonium acetate at pH 5 and the column was rinsed with the buffer at 4.5, 4, 3.5, 3, 2.5, 2.0, 2.5, 1.5, 1 (Fig. 4). The 225Ac eluted with two peaks at pH 5 and pH 3 with 96% eluting in the load and fractions with a pH from 5–3.5. The 223Ra and 227Th were both retained on the column and began to elute from the column at pH 1.5 with 98–100 percent of the isotopes eluting in the buffer at pH 3 to 1. The activity retained on the column was not measured. The breakdown of the PCST was evaluated and Ti was below quantification limits in the eluted load and pH 5 solutions, but Ti was quantified in all other fractions. The amount of Ti breakthrough in buffer at pH values from 4.5–2.5 was less than 1 μg per fraction. Eluting the PCST column with 0.5 M ammonium acetate buffer at pH 2, 1.5 and 1 resulted in higher breakthrough of Ti (11.7, 80, and 89 μg).

Figure 4
figure 4

pH studies: A Separation of 225Ac, 223Ra and 227Th using a PCST ion exchanger in 0.5 M ammonium acetate. 223Ra and 227Th and 225Ac is retained at pH values greater than 3. 223Ra and 227Th are eluted at more acidic pH values. Titanium present in fractions associated with study A, illustrating the breakdown of PCST material at lower pH (in green).

Initial optimization of the separation with PCST: Initial optimization of the separation examined using a rinse sequences with 6 bed volumes (BV) or column volume of 0.5 M ammonium acetate at both pH 5 and 3, and 12 BV at pH 1 (see Supplementary Fig. S3). Combining the load, pH 5 and 3 rinses resulted in 91% of the 225Ac, and approximately 39–41% of the 225Ac was eluted in pH 5 and 34–42% of the 225Ac was eluted in the pH 3 rinse. The 0.5 M ammonium acetate pH 1 rinse step eluted 44–81% of the Ra and 95% of the Thorium. The column retained 0.1–1.4% of the 225Ac and 19–56% of the 223Ra.

Optimized purification and PCST breakthrough: The rinse sequence used: 3X3BV of 0.5 M ammonium acetate at pH 5, 2X3BV of the buffer at pH 3, 2X3 BV of the buffer at pH 1 (Fig. 5). Combining the load, pH 5 and the first pH 3 rinse (heavy black line) resulted in the elution of 91% of the 225Ac. Based on the activity of 225Ac, 223Ra and 227Th the initially radionuclidic purity of the 225Ac was 78.4%, and the radionuclidic purity of the purified 225Ac in the combined fractions was 99.3%. In the pH 5 rinse step 62.9% of the 225Ac was eluted and in the pH 3 rinses 21.3% of the 225Ac was eluted with 18.9% eluting in the first pH 3 rinse and only 2.3% eluted in the second pH 3 rinse step. The second pH 3 rinse and the pH 1 rinses eluted 95% of 227Th. The pH 1 rinse contained 42% of 223Ra and 53.7% was retained on the column. Ti breakthrough was checked in the second pH 5, first pH 3 and both pH 1 fractions, and the Ti breakthrough was 0.025, 0.29, 120.7 and 142.5 µg per fraction consistent with previous studies.

Figure 5
figure 5

Optimized separation of 225Ac, 223Ra and 227Th using a PCST ion exchanger in 0.5 M ammonium acetate. 225Ac solution containing 223Ra and 227Th using a 0.5 mL column of PCST ion exchange material. The load, pH 5 and the first pH 3 rinse (heavy black line) contained 91% of 225Ac with a radiopurity of 99.3%. The second pH 3 rinse and pH 1 rinses eluted 95% of 227Th. The pH 1 rinse eluted 42% of 223Ra and 53.7% was retained on the column.

Discussion

Different separation methods and materials are being evaluated to purify 225Ac from Thorium, so that the US Department of Energy can supply 225Ac to researchers and clinicians on clinical scales19,21,22,23. In this manuscript PCST ion-exchanger was evaluated to determine if the material can be utilized for the purification of 225Ac from Thorium or radium targets or in a 229Th/225Ra generator.

Column studies

Column studies with PCST ion exchanger were plagued with poor (1 ml/15 min) or no flow rates. Sieving the PCST material through various mesh filters did little to increase the flow rates. In all column studies 100–200 mesh PCST was used and reasonable flow rates were achieved by soaking the PCST in buffer and decanting the buffer.

Acid study of PCST

Ammonium acetate buffer at pH 1 and both hydrochloric acid and nitric acid at a concentration of 0.1 M lead to breakdown of PCST material. The breakdown of the PCST at pH 5–3 is far less then at more acidic pH values. Using the PCST material at pH 1 or in 1, 2, and/or 3 M acid may require a cleanup column to remove Ti breakthrough.

Separation of Ba from La

The Ba-La separation was conducted to assess the potential of a separation of Ra and Ac radioisotopes with a PCST column, with the stable isotopes serving as surrogates for the radioisotopes. The elution of both metals at separate pH values was clear, and La eluted at pH 5 while Ba eluted at pH 1 (see Supplementary Fig. S2). Application: This purification approach could be used to separate 140La from 140Ba in a generator system. The study indicates all trivalent lanthanides will be eluted at pH 5 with 140La and 225Ac.

Evaluating PCST ion exchangers for purification of 225Ac

The elution of Ba and La on PCST was repeated with 223Ra, 227Th and 225Ac, and the separation was optimized to purify 225Ac.

The separation of 225Ac from 223Ra and 227Th had good reproducibility. In five studies (the pH study, three optimization studies with 225Ac, 223Ra and 227Th, and the column studies 225Ac, Th, Ag, Ba, Rh, Ce, La) greater than 90% of the 225Ac eluted in the load, pH 5 and/or pH 3 solutions. The optimized elution method to separate 225Ac was selected based on the elution of the highest percentage of 225Ac with the lowest percentage of impurities, in this case, 223Ra and 227Th. The optimized method rinsed the PCST column with more 0.5 M ammonium Acetate at pH 5 and 3 resulted in a shift in the 225Ac elution peak. The result was more 225Ac was eluted earlier with 92% eluted in the pH 5 and first pH 3 rinse step. The process produced very pure 225Ac with 223Ra and 227Th eluting at low pH, and this data indicates the optimized method with PCST material could be used in several different production approaches to purify 225Ac from Thorium and/or Radium radioisotopes.

Applications of separation

225Ac from a 225Ra/229Th generator: 225Ac has been produced at Oak Ridge National Lab (ORNL) from a 225Ra/229Th generator and they produce 5.5 × 1010 Bq (~1.5 Ci) per year24. The one column separation of 225Ac from 223Ra and 227Th with PCST could simplify the multicolumn approach used at ORNL to purify 225Ac in the 225Ra/229Th generator. The ORNL process is a four step chemical process with two MP1/NO3 columns to separate 225Ac and 225Ra from 229Th. Then the 225Ac is purified from 225Ra with two AG50X4/1.2 HNO3 purification steps. The high selectivity of PCST for both thorium and radium would simplify the purification of 225Ac, and the process would be one column, making the purification shorter than the ORNL process. Accelerator produced 225Ac: Accelerator produced 225Ac can be produced at high energy (>100 MeV) with a natural thorium target or at low energy (10–25 MeV) from a 226Ra target. PCST for the purification of 225Ac from 232Th targets: Although the PCST column worked to separate 225Ac from Thorium, Ra and some fission products the approach is similar to published separations that capture Thorium on an MP1 column and let 225Ac pass through the column24. This separation strategy would work for smaller thorium target. For larger scale clinical production of 225Ac with 50 to 100 g Thorium targets and potential Thorium stack targets could be required resulting in 100–600 grams of Thorium in the separation. The small capacity of PCST for Thorium indicates a large mass of PCST ion exchanger would be needed to capture all the Thorium. To process one 50 gr Thorium target it was estimated 10 L PCST column would be needed, so the material does not have a reasonable capacity to purify 225Ac from Thorium targets. PCST for the purification of 225Ac from 226Ra targets: Low energy protons irradiating a 0.3 g 226Ra target can produce clinical scales of 225Ac (~ 1 Ci/target)7,25. The amount of PCST ion exchange material to process a 226Ra target was estimated from capacity studies with barium, and the data indicates a minimum of a 12.5 mL PCST column would be needed to retain 226Ra in the target. The PCST separation method to purify 225Ac could be used to purify 225Ac from a 223Ra targets. 226Ra could be eluted from the PCST ion exchanger in pH 1 buffer, and the process could be used to recycle the 226Ra.

Removal of radio impurities (223Ra and 227Th) in accelerator produced 225Ac from Th targets: Accelerator produced 225Ac from a proton irradiated thorium targets has 0.1% abundance of 227Ac (t1/2 = 21.8 years) at end of bombardment. 227Ac decays to 223Ra (t1/2 = 11.4 days) and 227Th (t1/2 = 18.5 days), and 227Ac and the daughters represent the major radio- impurities for 225Ac. The expiration of a batch of accelerator 225Ac is defined by the purified 225Ac failing one of its specifications, which are currently being determined by the Trilab 225Ac team. The radiopurity of 225Ac will likely be the first specification that fails. The Trilab team has estimated the radiopurity post purification in the presence of 227Ac and 227Ac and daughters for BLIP produced 225Ac from Th targets18. Removal of 223Ra and 227Th would increase the radiopurity of 225Ac produced from a Th target at BLIP. During the development of the PCST separation the original radiopurity of 225Ac was 78.4% (calculated from 225Ac, 227Th and 223Ra), but after performing the purification with PCST column the radiopurity was 99.3% and the recovery of 225Ac was 92.4%. This improvement in radiopurity indicates that this separation can be used to extend 225Ac shelf life by removing 227Ac daughters, 223Ra and 227Th. A PCST column run on the 225Ac sample would remove 223Ra and 227Th; increasing the radiopurity to greater than 98% and this could be done out to 30.1 days. For 225Ac produced from a Th target at BLIP the radiopurity falls below 98% after 14.9 days after the last separation step. A radiopurity greater than 98% can be achieved with a PCST column out to 27.8 days. In a clinical setting, the collection of the 18 BV of the pH 5 rinse and first 6 BV of the pH 3 rinse would recover 92.4% of eluted 225Ac and a negligible percentage of impurities. This 12 mL sample of 225Ac would be easy to evaporate.

Conclusion

The impact of developing a material with specific isotope and/or metal selectivity would potentially be invaluable in assisting with efforts in medical isotope production. The studies herein evaluated titanium ion exchanger and examined if the material could be used for the purification of 225Ac. Examination of the effects of acid rinses on PCST indicated that even 0.1 M acid, either nitric or hydrochloric, breaks down the material and resulted in the elution of the material (Titanium). This led to the conclusion that acid more dilute than 0.1 M is needed when working with PCST. For the separation of 225Ac from radioactive Ra and Th, the optimized method used 18 BV of buffer at pH 5 and 6 BV of buffer at pH 3. This lead to a high recovery of eluted Ac (92.4%) and high radiopurity (99.3%). An 225Ac 229Th generator can be established based on this separation. Capacity studies of Barium and Thorium on PCST indicated that the material did not have a high enough capacity for a production scale thorium target (≥50 g) of PCST. However, PCST could be used to purify 225Ac from smaller production scale 226Ra targets (0.3 g).

Materials and Method

Reagents were used from manufacturer without additional purification: phosphoric acid, fumed silica, titanium isoproproxide and KOH Pellets were purchased from Sigma Aldrich. Sodium hydroxide (98%), nitric acids (70% optima) and trace metal grade hydrochloric acid were purchased from Fisher. La, Ce, Lu ICP standards were purchased form Fluka in 1000 mg/L concentrations. ICP single elemental certified standards of: Th, Ag, Ba, Rh, Ce, and La were purchased from SPEX Certiprep. All solutions were prepared using Milli-Q water and all experiments were conducted at room temperature. All the chemicals used were of analytical reagent grade. Buffers were prepared from previously prepared 0.5 N Sodium Acetate buffer and adjusted with 8 N HCl or 10 M NaOH. Initial and equilibrium pH readings were obtained using a Denver Instruments UB-10 pH/mV meter calibrated at pH 2.0, 4.0 and 7.0. Since Ba chemically behaves similarly to Ra and La is chemically similar to 225Ac for some studies Ba and La can be used as surrogates. 225Ac radiotracer was supplied by Oak Ridge National Laboratory as a dried sample, and the sample was dissolved in 0.1 M HCl solution prior to use. 223Ra and 227Th were present in some 225Ac samples as a result of the decay of 227Ac.

Synthesis of PCST inorganic ion-exchanger

PCST were synthesized according to published methods26,27. Phase and purity was confirmed by powder X-Ray diffraction (patterns collected using a Rigaku MiniFlex II Desktop X-Ray diffractometer sampling at 0.040 degrees at a speed of 1degree/min, starting at 5 degrees and ending at 60 degrees.

Determination of Kd values for different inorganic ion-exchangers

225Ac and Th

Experimental solutions, consisting of 20 mg L−1 of Th and 3.7 × 104 Bq 225Ac in 0.5 M sodium acetate (NaOAc), were adjusted to a pH of 1, 2, 3, 4 or 5 with 10 M NaOH or 69% HNO3. Inorganic ion-exchangers HCST (100 ± 0.5 mg) were added to 10 mL of the metal containing solution. The tubes were shaken (using Thermo Scientific compact digital microplate shaker) for 12 hours at room temperature. The tubes were centrifuged (4000 rpm, 2598 RCF) for 4 minutes and the aqueous phases were separated using 0.2 µm micro syringe filter. An aliquot from the aqueous phases was diluted in 2% nitric acid and analysis performed.

Rh, Ag, Ba, La, Ce and Th on PCST inorganic ion-exchangers

A solution consisting of: 30 mg L−1 of each of Ag, Ba, Rh, Ce, and La; and 150 mg L−1 of Th in 0.5 M NaOAc. Ba was used as a surrogate of Ra, and La was used as a surrogate for 225Ac as the chemistries are similar. The PCST inorganic ion-exchangers (30 ± 0.3 mg) were added to the 10 mls of the metal containing solution. The samples were processed and analyzed as described in the previous section.

Analysis and calculations of Batch studies

Actinium activities in the initial, intermediate and final solutions were determined by using a gamma spectrometry (ORTEC) with a calibrated high purity germanium detector28. The separation fractions containing 225Ac, 227Th and 223Ra were quantified after 24 hours by gamma spectroscopy at 236 (227Th), and 269.6 keV (223Ra). After 24 hours the original activity associated with 213Bi and 221Fr has decayed away (24 hours >10 half-lives of 213Bi and 221Fr). The presence of 213Bi and 221Fr in the samples is the result of in growth from 225Ac, and activity associated with 213Bi and 221Fr would be at equilibrium with 225Ac. At the time of analysis, 225Ac and its daughters (specifically 221Fr and 213Bi) were at equilibrium with 225Ac, and the gamma peak at 440 KeV for Bi-213 was used to quantify 225Ac. The 218 KeV gamma peak for 221Fr was used to quantify 225Ac and similar results were obtained.

The concentration of thorium and other metals were measured using ICP-OES (Perkin Elmer Optima 7300 DV spectrometer), and the instrument was calibrated according to published methods28. The wavelength (λ) used for thorium, barium, lanthanum, cerium, rhodium, silver and titanium analysis were 283.73, 233.527, 408.672, 413.764, 343.489, 338.289 and 334.94 nm respectively.

Kd values were calculated based on the following equation:

$${K}_{d}=[({C}_{i}-{C}_{f})/{C}_{f}]V/g$$

Where Ci = Stock concentration metal, Cf = Final concentration metal, V = Volume of stock solution, and g = Measured weight of ion-exchanger. Kd values were plotted versus pH, and the standard deviation of triplicate samples was calculated.

Column studies

Column Preparation Method

The inorganic ion exchange material was sifted through >50, 50–100, 100–200, 200–400 and <400 µm mesh sifter. For all column studies the particles between 100 and 200 µm in size were used and approximately 1 gram of material was added to 20 mL 0.5 M ammonium acetate at pH 5. The sample was mixed vigorously then the mixture was allowed to settle before decanting the supernatant. This was repeated three times to remove any small residual particles that impeded column flow and caused poor flow rates. Then the inorganic ion exchange material was used to prepare columns with 0.4–0.5 mL bed volumes. The columns were rinsed with 20 BV of 0.5 M ammonium acetate at pH 5 prior to use, and the pH of the solution eluting the column was at pH 5. Columns were timed to monitor the flow rate.

Acid Study of PCST

Two 0.5 mL BV columns of poorly crystalline silicotitanate (PCST) were prepared in 0.5 M ammonium acetate at pH 5. One column was rinsed with 10 mL of 0.5 M ammonium acetate at pHs 5, 3, and 1. Then the column was rinsed with: 4 × 3 mL of each of the following concentrations of nitric acid: 0.1 M, 1 M, 2 M and 3 M. A 500 microL aliquoted of each rinse solution was diluted with 4.5 mLs of 2% Nitric Acid to make an ICP-OES sample, and the amount of titanium was quantified. The experiment was repeated with the second column with the exception hydrochloric acid was used instead of nitric acid.

Capacity studies to Evaluate resin for purification of 225Ac from production targets or isotope generators

Barium: A 0.4 mL column of PCST was prepared in 0.5 M ammonium acetate at pH 5. A barium solution was prepared by evaporated 25 mg of Ba metal ICP standard and resuspended in 5 mL of 0.5 M ammonium acetate buffer at pH 5. The Ba solution was loaded on the PCST column and the column was rinsed with 3 × 10 mLs of 0.5 M ammonium acetate at pH 5. The amount of barium in the load and rinse solution was quantified by ICP-OES. Thorium: The study was repeated for thorium with the exception that a 0.5 mL PCST column was used and the load solution contained 100 mg of thorium.

225Ac, 227Th, 223Ra Separation

pH Elution with either PCST ion exchanger: A 0.5 mL PCST column was prepared in 0.5 M ammonium acetate at pH 5, and a 10 mL load solution of the buffer was prepared with tracer quantities of 225Ac (4.00 × 105 Bq), 227Th (8.136 × 104 Bq) and 223Ra (2.886 × 104 Bq). A HPGE counting sample was prepared by diluting 500 µL of the prepared load solution to 3 mL. The remaining load solution was added to the PCST column. Then the column was rinsed with 3 mL of 0.5 M ammonium acetate at each of the following pH values: 5, 4.5, 4, 3.5, 3, 2.5, 2, 1.5, and 1. The radioactivity in the load and rinse samples were quantified by HPGE analysis and the titanium was quantified in the samples by ICP-OES analysis. The ICP-OES samples were prepared by diluting the 3 mL fractions to 5 mL’s with 2% nitric acid.

Optimized Elution method: A 0.5 mL PCST column and a solution containing 225Ac, 227Th, and 223Ra in 0.5 M ammonium acetate at pH was prepared as described above. The previous experiment was repeated with the following rinse sequence of 0.5 M ammonium acetate: 3 × 3 mL at pH 5, 2 × 3 mL at pH 3, and 2 × 3 mL at pH 1. Radioactivity in the fractions was determined by HPGE analysis and ICP-OES was conducted on one of the pH 5 and 3 rinses and both pH 1 rinses.