Correction to: Scientific Reports https://doi.org/10.1038/s41598-018-34809-6, published online 06 November 2018
This Article contains typesetting errors.
In the Materials and Methods section, under the subheading ‘Munich Compact Light Source’,
“The spectrum at the position of the sample was measured with an energy-dispersive Amptek X-123 detector (Amptek Inc., Bedford, Massachusetts) with an 500 m Si sensor and from that a mean energy of Emean = 24.3 keV was calculated.”
should read:
“The spectrum at the position of the sample was measured with an energy-dispersive Amptek X-123 detector (Amptek Inc., Bedford, Massachusetts) with an 500 µm Si sensor and from that a mean energy of Emean = 24.3 keV was calculated.”
Furthermore, in the Materials and Methods section, under the subheading ‘Grating Interferometer’,
“The grating interferometer is situated at a distance of about 15 m from the X-ray source point (size: 45 × 45 m2 r.m.s., divergence angle: 4 mrad).”
should read:
“The grating interferometer is situated at a distance of about 15 m from the X-ray source point (size: 45 × 45 µm2 r.m.s., divergence angle: 4 mrad).”
“The Talbot interferometer is realized with a phase grating (G1) with a period of 4.92 m, duty cycle of 0.5 and a nickel filling height of 4.39 m providing a phase shift of π/2 for the design energy of 25 keV. Period, duty cycle and gold filling for the absorption grating are p2 = 5 m, 0.5 and 70 m.”
should read:
“The Talbot interferometer is realized with a phase grating (G1) with a period of 4.92 µm, duty cycle of 0.5 and a nickel filling height of 4.39 µm providing a phase shift of π/2 for the design energy of 25 keV. Period, duty cycle and gold filling for the absorption grating are p2 = 5 µm, 0.5 and 70 µm.”
“All tomographic images were acquired with a single photon counting Pilatus-200 K detector (DECTRIS ltd., Baden, Switzerland) with a 1 mm thick silicon sensor and an effective pixel size of peff = 160 m.”
should read:
“All tomographic images were acquired with a single photon counting Pilatus-200 K detector (DECTRIS ltd., Baden, Switzerland) with a 1 mm thick silicon sensor and an effective pixel size of peff = 160 µm.”
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Braig, E., Böhm, J., Dierolf, M. et al. Publisher Correction: Direct quantitative material decomposition employing grating-based X-ray phase-contrast CT. Sci Rep 9, 11076 (2019). https://doi.org/10.1038/s41598-019-46258-w
Published:
DOI: https://doi.org/10.1038/s41598-019-46258-w
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.