Abstract
This study developed a new method for forensic saliva identification using three oral bacteria, Streptococcus salivarius, Streptococcus sanguinis, and Neisseria subflava, combined with a real-time polymerase chain reaction (RT-PCR) system we called OB mRT-PCR. Analytical sensitivity results showed that the target bacteria were amplified at 102–107 copies/reaction, and analytical specificity was assessed using 24 other viruses, bacteria, and protozoa. To evaluate the OB mRT-PCR kit for forensic applications, saliva from 140 Korean individuals was tested, and at least two target bacteria were detected in all the samples. Additional studies on non-saliva samples demonstrated the specificity of the kit. Comparison of the kit with two conventional saliva test methods, the SALIgAE and RSID-Saliva assays, indicated that it was more sensitive and applicable to saliva samples in long-term storage (up to 14 weeks). Additionally, through amplification of mock forensic items and old DNA samples (isolated without lysis of the bacterial cells, regardless of their Gram-positivity), we found that the kit was applicable to not only saliva swabs, but also DNA samples. We suggest that this simple RT-PCR-based experimental method is feasible for rapid on-site analysis, and we expect this kit to be useful for saliva detection in old forensic DNA samples.
Similar content being viewed by others
Introduction
The identification of saliva from stains on evidence is an important procedure in forensic investigations, particularly in those related to sex crimes. In addition, saliva detection on blood stains allows distinguishing expectorated blood spatter, which may aid complete understanding of incidents in violence, robbery, and homicide cases1,2. The detection of amylase has been generally used for testing of presumptive saliva, because amylase exists at particularly high levels in it. However, amylase is also found in other body fluids, including blood, urine, semen, and vaginal secretions3,4,5. Additionally, protein-based methods for identification of body fluids have varying degrees of sensitivity according to the inter- and intra-variability of the protein levels6,7. Thus, different strategies, using messenger RNA, microRNA, and methylation, capable of detecting the presence of saliva have been studied6,7,8,9,10. However, these methods are labour-intensive and time-consuming because RNA handling requires particular care to maintain its stability against ubiquitously present ribonucleases, and methylation studies requires a bisulfite-converting process on the DNA10. Detection of oral bacterial DNA based on polymerase chain reaction (PCR) has been studied as a strategy and reported to be simple and sensitive1,11,12,13. Additionally, the study of microbial patterns through sequencing of body fluids has been reported recently14. In this study, we developed an oral bacteria multiplex real-time PCR kit, named OB mRT-PCR, as a new forensic saliva identification tool. Real-time PCR offers a number of advantages over conventional PCR, including high sensitivity, improved accuracy, and evaluation of data without post-PCR detection procedures15. There are numerous bacterial species and phylotypes in the oral cavity16, and the majority of oral bacteria are unique to this habitat1,12,17,18. In addition, the environment (eating and drinking habits, tobacco use, age, and chronic nail-biting habits) can change the complex community of oral bacteria19,20,21,22,23. For these reasons, one or two oral bacteria may not be enough to determine the presence of saliva. Therefore, we developed the OB mRT-PCR kit using markers for three oral bacteria, Streptococcus salivarius, Streptococcus sanguinis, and Neisseria subflava. The targeted oral bacteria were selected from the literature and experiments on bacterial identification from saliva cultures using a MicroSeq. 500 16 S rRNA-based bacterial ID system24,25. According to previous reports, S. salivarius is a prominent member of the oral microbiota26, S. sanguinis is the most abundant species found in oral biofilms27, and N. subflava comprises part of the normal flora of the oral cavity and respiratory tract of humans28. We evaluated whether the OB mRT-PCR kit could provide consistent results and little variability when used on 140 Korean individuals. In the specificity study, blood, urine, vaginal fluids, semen, faeces, and skin samples were examined. The sensitivity of the kit was assessed by comparing it with conventional presumptive and confirmatory saliva testing methods based on amylase, the SALIgAE and RSID-Saliva assays, using saliva subjected to long-term storage (up to 14 weeks). In addition, mock forensic items that had contacted human mouths (cigarettes, straws, mugs, paper cups, forks, and bite marks on corncobs) were tested to evaluate the forensic potential of the kit. The evaluation was mainly performed by direct RT-PCR (without a DNA isolation step)29,30 using swabs as templates for rapid detection. Furthermore, we used old DNA samples obtained from real crime scenes as templates. The DNA samples were isolated without additional treatment to lyse microbial cells and had been stored for up to 13 years. Our data showed that the OB mRT-PCR kit was useful as a saliva identification tool and could be applicable not only to swabs, but also to isolated DNA, even that isolated without any particular Gram-positive bacterial cell lysing process.
Results
Analytical performance
For the evaluation of the analytical performance of the OB mRT-PCR kit, synthetic genes prepared at various concentrations were used. The linearity of the multiplex real-time PCR (mRT-PCR) conditions was measured using synthetic genes in the amount of 103, 105, and 107 copies/reaction, corresponding to low, intermediate, and high concentrations, respectively (S. salivarius R2 = 0.988, efficiency = 97.7%, S. sanguinis R2 = 0.999, efficiency = 99.7%, and N. subflava R2 = 0.999, efficiency = 103.0%; Fig. 1). To confirm the analytical sensitivity and the measurement range, synthetic genes were used at 101–107 copies/reaction and analysed four times for each dilution. The experimental results showed that all three oral bacteria were amplified when used at 102–107 copies/reaction (Fig. 2). The analytical specificity was evaluated using 24 other viruses, bacteria, and protozoa (Table 1), none of which was amplified.
Evaluation of the OB mRT-PCR kit
The OB mRT-PCR kit was evaluated upon amplification of 140 saliva samples from different individuals: this analysis is particularly important because the oral bacterial community differs among individuals. The saliva samples were collected using swabs, and a piece (2-mm × 2-mm) of the swab was directly used as a template for the test. The results showed that at least two oral bacteria species were detected in all saliva samples (Table 2). This supports the ‘positive’ result criteria of the OB mRT-PCR kit indicating that at least two bacterial species should be detected to determine presence of saliva (Fig. 3). The three bacterial species were detected by the kit in 91.4% samples. Of these, S. salivarius was found most abundantly in saliva samples and was not detected in only one sample. S. sanguinis was not detected in four, and N. subflava was not detected in seven of the 140 samples. The estimated mean Ct values of these oral bacteria were 24.1 ± 1.8 (S. salivarius, n = 139), 27.0 ± 1.5 (S. sanguinis, n = 136), and 23.8 ± 2.1 (N. subflava, n = 133). To observe the influence of tooth brushing, 24 saliva samples (in which all oral bacteria were detected) were additionally collected 10 min after brushing and tested. Tooth brushing had little effect on the detection of the oral bacteria (Table 3); although the Ct values increased slightly, all were within the positive range (Ct values should be below 36 to be reliable). In the specificity study, blood, urine, vaginal fluid, semen, faeces, and skin samples were tested and were all identified as negative except one faeces sample (Table 4), which was positive for S. salivarius with an average Ct value of 30.7. In the sensitivity study of the OB mRT-PCR kit, we diluted whole saliva 1/2, 1/10, 1/50, 1/250, and 1/1,250 using distilled water and stored the samples at 4 °C for 1 day, 7 weeks, or 14 weeks. One microliter of diluted saliva was used with the OB mRT-PCR kit, SALIgAE assay, and RSID-Saliva assay, as described herein. The results showed that the OB mRT-PCR kit and RSIDTM-Saliva assay were more sensitive than the SALIgAE assay was when using 1-day old samples (Fig. 4 and Table 5). At 7 weeks, the sensitivity of the RSID-Saliva assay slightly decreased (Fig. 4). Interestingly, oral bacteria detection was slightly higher after storage for 7 weeks than after storage for 1 day. The OB mRT-PCR kit was the only able to detect the saliva in all 1/250 and some 1/1,250 diluted saliva samples.
Forensic application
A total of 40 mock forensic items were obtained, including cigarettes, straws, mugs, paper cups, forks, and bite marks on corncobs. Pieces (2-mm × 2-mm) of the cigarettes and swabs used to wipe the mock forensic items were used directly as templates. All target bacteria were positively detected in 82.5% of samples (33/40 samples), and two target bacteria in the other 17.5% (7/40 samples). The calculated mean Ct values of the total items were 30.9 ± 2.1 (S. salivarius, n = 40), 32.4 ± 1.8 (S. sanguinis, n = 35), and 29.3 ± 1.9 (N. subflava, n = 38). Comparing the RT-PCR results from the mock forensic samples with those from the 140 Korean saliva samples, the detection rate using the mock forensic samples was lower and mean Ct values were higher than those measured using the 140 saliva samples (Table 6). However, since two or more bacteria were detected in all samples, the samples were all considered positive for ‘saliva presence’. To verify that the OB mRT-PCR kit can be applied to DNA samples, we amplified various DNA samples as described in Table 7. Ten DNA samples (isolated from evidence containing saliva) were stored between 6 months and 13 years, and the total DNA concentrations ranged from 0.13 ng/µL to 4.76 ng/µL (Table 7). As negative controls, six DNA samples isolated from other body fluids (blood, vaginal fluid, and semen) were amplified simultaneously. We found that one vaginal sample tested positive for S. salivarius. However, the detection of one bacterial does not meet the criteria for ‘saliva presence’. All saliva DNA samples except one (cigarette butt stored for 7 years) were determined to be positive by the OB mRT-PCR kit. All target bacteria were positively detected in 40% of samples (4/10 samples), and two target bacteria were positively detected in 50% of the samples (5/10 samples). The mean Ct values of the DNA samples containing saliva were 31.6 ± 3.3 (S. salivarius, n = 7), 33.5 ± 1.5 (S. sanguinis, n = 8), and 32.9 ± 2.7 (N. subflava, n = 8). The detection rate of target bacteria when using old DNA was lower than that when using the mock forensic samples. Nevertheless, the data obtained demonstrate that the OB mRT-PCR kit can be used with old DNA samples. The DNA samples used in our analysis were isolated using a QIAmp DNA micro kit (Qiagen, Hilden, Germany), and no additional treatment was performed to lyse bacterial cell walls. This indicates that the OB mRT-PCR kit is a useful tool for the detection of saliva in old DNA samples that have not been tested for saliva, even if the samples were isolated without specific treatment to lyse bacterial cells. In a previous report, the same kit has been used for the analysis of the microbial diversity of oral saliva31. Since the QIAmp DNA micro kit is not designed specifically for bacterial cells, additional treatments might be required for the complete lysis of Gram-positive bacterial cells32. However, two of the bacteria used as markers in our study were Gram-positive, and though other kits might be found more convenient/efficient in this regard, the QIAmp DNA micro kit did efficiently allow their amplification.
In the National Forensic Service (NFS) of the Republic of Korea, most of the old forensic DNA samples have been isolated by conventional human genomic DNA preparation methods without additional treatments to lyse microbial cell walls, because the intention of the isolation was human DNA profiling. Our kit can potentially be used with such samples. Additionally, even on DNA samples stored up to 13 years, oral bacteria were detectable in as little as 0.13 ng of total DNA. The amount of total DNA is not the amount of bacterial DNA: most of the DNA is indeed human genomic DNA and the amount of bacterial DNA is very small. Therefore, our data demonstrate that large amounts of DNA are not required to identify saliva using the OB mRT-PCR kit, and that this kit can be successfully used with old DNA (stored for up to 13 years).
Discussion
Various approaches for saliva identification have been studied33, and the use of oral bacteria detection-based PCR has also been reported11,12,13. In this paper, we developed an oral bacteria multiplex RT-PCR kit (named OB mRT-PCR) for forensic saliva identification using three target oral bacteria, S. salivarius, S. sanguinis, and N. subflava as markers. Due to environmental factors, the types and amounts of oral bacteria vary among individuals; the OB mRT-PCR kit will improve the accuracy of saliva identification by simultaneously analysing three species of bacteria as targets. The kit was evaluated by analysing 140 Korean saliva samples; the results showed that two or more oral bacterial species (targeted by the kit) were detected in all samples. In a specificity study of various body fluid samples, S. salivarius was detected in one faeces sample, consistently with the results of a previous report34. Additionally, S. salivarius was detected in one forensic DNA sample isolated from vaginal fluid. However, the identification of only one bacterial species does not indicate presence of saliva according to the criteria we indicated. Because bacteria are associated with some diseases35,36,37,38, their presence in other tissues, in some instances, cannot be excluded. Only one bacterial target was detected in the faeces sample and vaginal DNA sample; thus, these samples were classified as negative. For accurate determinations, each laboratory may need an internal validation study to establish the criteria for positive determination. The consideration of the donor’s clinical information and the analysis of various negative controls (such as no saliva and/or no DNA samples, and swab of experimental space to investigate the environmental bacteria) might help to increase the accuracy of the test.
The high sensitivity of the RSID-Saliva assay has been reported previously2,39, but since it is a protein-based method, the sensitivity of this assay decreases if samples are stored for more than seven weeks. On the other hand, the OB mRT-PCR kit is a bacterial DNA-detecting method, which features high sensitivity and a long persistence of sensitivity, and therefore, it is superior when used with forensic samples that have been stored for a long time. In addition, the OB mRT-PCR kit can be used both with mock forensic samples and as well as DNA samples. In recent years, there have been important legal changes in the Republic of Korea, including the extension of the period of prescription for murder cases and sexual crimes. These changes have increased the demand for re-analysis of evidence and/or stored DNA held by the NFS40. Furthermore, as Short Tandem Repeat (STR) analysis techniques evolve and become more sensitive and with higher tolerance to inhibitors, the detection rate of STR (autosomal STR and Y chromosome-STR) has increased41,42,43. The importance of accurate identification of the source of the DNA profile has also increased because body fluids can be used as indicators of the sequence of events44. The OB mRT-PCR kit has the advantage of being able to identify the presence of saliva in old DNA. Saliva identification by methylation can also be used with old DNA, but relatively high concentrations of DNA are required45. Thus, we suggest that the OB mRT-PCR kit is more suitable for identification of saliva in the presence of low amounts of DNA. Considering these results, the OB mRT-PCR kit will be a useful confirmatory tool for the identification of saliva not only from swabs, but also from isolated DNA.
Conclusions
This study aimed to develop a new saliva identification tool and evaluated its use on samples from Korean individuals, mock forensic samples, and DNA samples. Three species of oral bacteria (S. salivarius, S. sanguinis, and N. subflava) were selected as targets for mRT-PCR. In all 140 Korean individuals, mock forensic samples, and DNA samples (except one DNA sample), DNA from two or more oral bacterial species was successfully amplified with the OB mRT-PCR kit (Ct values below 36). Although S. salivarius was found in other samples, only samples containing saliva were determined to be positive according to the criteria for positive identification we defined (detection of two or more of the target bacterial species). The advantage of the OB mRT-PCR kit is that the experimental process is simple and fast through direct RT-PCR, and it can be used to analyse even DNA samples at very small concentration.
Methods
Samples
Bacteria used in this study were purchased from the National Culture Collection for Pathogens (NCCP, Osong, Korea) and the Korean Collection for Type Cultures (KCTC, Jeongeup, Korea). Some inactivated bacteria, viruses, and protozoa were purchased from ZeptoMetrix (Buffalo, NY, USA).
For selection of the target bacteria, the expectorate from four healthy volunteers was collected into 50-mL sterile plastic centrifugation tubes. For evaluation of the OB mRT-PCR kit, samples from 140 Korean volunteers (79 males and 61 females) were collected using sterile cotton swabs (Fisher Scientific, Hampton, NH, USA) at least two hours after tooth brushing. Saliva samples from 24 volunteers (12 male and 12 female) were additionally collected 10 min after tooth brushing in order to observe the effects of tooth brushing on bacterial detection. For the specificity study on other body samples, blood (N = 10), urine (N = 10), vaginal fluid (N = 10), semen (N = 5), faeces (N = 3), and skin (N = 5) samples were collected using sterile cotton swabs. Five skin samples were collected by wiping the arm skin with a wet cotton swabs, and all swabs were allowed to dry for 24 h at 25 °C, and were stored at 4 °C until analysis. For a sensitivity comparison between the OB mRT-PCR kit and commercial saliva test kits, whole saliva from three volunteers was additionally collected in 1.5-mL sterile tubes.
A total of 40 mock forensic samples46,47,48 were from 10 cigarettes, 10 straws, 5 mugs, 5 paper cups, 5 forks, and 5 bite marks on corncobs. Cigarettes were cut into 2-mm × 2-mm pieces, and the other mock forensic samples were wiped with swabs soaked in distilled water, dried for 24 h at 25 °C, and then cut into 2-mm × 2-mm pieces. A total of 16 forensic DNA samples were isolated from crime scene evidence that had been analysed by the NFS from 2005 to 2016 for forensic purposes. Ten saliva, 2 semen, 2 blood, and 2 vaginal fluid samples were used. The use of the samples and the analytical procedures involved were approved by the Intuitional Review Board of the National Forensic Service of the Republic of Korea and in accordance with the standards of the Declaration of Helsinki. All volunteers provided written informed consent and all methods were confirmed in accordance with the relevant guidelines and regulations.
Determination of the target bacteria
Three bacterial species have been reported by many publications to be commonly found in saliva. We determined the targets by considering the results of bacterial identification studies on cultured saliva. Four saliva samples were cultured on blood agar plates (KOMED, Seongnam Korea) supplemented with 1.5% (w/v) pancreatic digest of casein, 0.5% (w/v) pancreatic digest of soybean meal, 5% sheep blood, 0.5% (w/v) sodium chloride (NaCl), and 1.5% (w/v) agar. All cultures were incubated for 18 h in an atmosphere of natural air at 37 °C49. Colonies were amplified using the MicroSEQ. 500 Kit bacterial ID system (Perkin-Elmer, Foster City, CA, USA). Amplified 16 S rDNA fragments from the target bacteria were purified with the ExoSAP-IT (Thermo Fisher Scientific, Waltham, MA, USA) treatment and sequenced by the Sanger method. The MicroSEQ ID software v3.0 (Perkin-Elmer) with the AB_Bacteria500Lib_2013 library sets was used on the obtained 16 S rDNA sequences from target unknown bacteria, and the identification process was conducted automatically.
RT-PCR
In order to extract nucleic acids from cultured bacteria and some inactivated bacteria, viruses, and protozoa, we used a QIAamp DNA mini kit (Qiagen), and a GeneJET viral DNA and RNA purification kit (Thermo Fisher Scientific). Nucleic acids were extracted according to the experimental method and stored at 4 °C until analysis. The following target genes of three oral bacteria were selected for amplification: methionine aminopeptidase (S. salivarius), species-specific intergenic spacer region (S. sanguinis), and aspartate semialdehyde dehydrogenase (N. subflava)50,51,52. The specific sequences were confirmed to have no cross-reaction with other microorganisms by in silico analysis. The primers and probes were synthesized by Bioneer (Daejeon, Korea) as described in Table 8. The real-time PCR mixture contained 10 µL of AttoPlex 2X Real-time PCR Master Mix (JS Biotech, Namyangju, Korea), 1 µL of each primer (concentration, 10 µM), 1 µL of each probe (concentration, 5 µM), 1 µL of DNA extracts, and 7 µL of nuclease-free water. The thermal cycle conditions were as follows: 5 min denaturation at 95 °C, 40 cycles of 95 °C for 10 s, and 60 °C for 60 seconds. Real-time PCR was performed using the CFX-96 real-time PCR detection system (Bio-Rad, Hercules, CA, USA), and the cut-off values were set automatically at every run.
Performance test
To confirm the amplification sensitivity and linearity, genes containing the amplified sequence of each oral microorganism were synthesized by Bioneer and prepared at a concentration of 101–107 copies/µL. The amplification sensitivity under mRT-PCR conditions was determined four times for each concentration. To confirm the linearity of the amplification conditions, three concentrations (103, 105, and 107) were used. Similarly, the PCR efficiency and the R2 values were confirmed by repeating the experiment four times. Specificity experiments used 24 bacteria, viruses, and protozoa to confirm cross-reactivity.
Evaluation and forensic application of the OB mRT-PCR kit
To evaluate the performance of the OB mRT-PCR kit in 140 Korean individuals, we prepared approximately 2-mm × 2-mm pieces of the top surfaces of swabs. Each piece was directly incubated with 19 µL of the OB mRT-PCR kit reaction mixture on the CFX-96 real-time PCR instrument. Tests were carried out in triplicate and repeated three times. We established two criteria for the positive determination of saliva presence by the OB mRT-PCR kit (Fig. 3a): first, the detected Ct values had to be below 36, and second, more than two oral bacterial species (among the three target bacteria detected by the kit) had to be detected.
The sensitivity was accessed by comparing the OB mRT-PCR kit with two commercial saliva detection kits, the SALIgAE assay kit (Abacus Diagnostics, West Hills, CA, USA) and the RSID-Saliva assay kit (Independent Forensics, Lombard, IL, USA) using three diluted whole human saliva samples. The samples were diluted in distilled water 1/2, 1/10, 1/50, 1/250, and 1/1,250. In order to observe the influence of storage time, the RT-PCR and serology tests were performed after 1 day, 7 weeks, and 14 weeks of storage. One microliter of diluted saliva was used with the OB mRT-PCR kit, SALIgAE assay, and the RSID-Saliva assay. In the SALIgAE assay, 1 µL diluted saliva was added to 30 µL of the SALIgAE solution, and the test results were read after 10 min. In the RSID-Saliva assay, 1 µL of diluted saliva was added to 50 µL of extraction buffer and incubated for 1 h at room temperature, and then mixed with 50 µL running buffer. The test results were read after 10 min. All analyses were carried out in triplicate.
The collected 40 forensic samples were cut into 2-mm × 2-mm pieces, each of which was mixed with 19 µL reaction mixture from the OB mRT-PCR kit. All analyses were carried out in triplicate.
The forensic DNA samples were collected described as Table 7. All DNA samples were isolated using a QIAmp DNA micro kit, and no treatment to lyse bacterial cell walls was performed. One microliter of DNA was used as a template for RT-PCR. DNA samples were quantified in triplicate using a Qubit dsDNA HS Assay Kit (Life Technologies, Darmstadt, Germany), and the Qubit 2.0 Fluorometer (Life Technologies) according to the manufacturer’s instructions. In the calculation of mean Ct values, negative values were excluded.
References
Power, D. A., Cordiner, S. J., Kieser, J. A., Tompkins, G. R. & Horswell, J. PCR-based detection of salivary bacteria as a marker of expirated blood. Sci. Justice. 50, 59–63 (2010).
Park, H. Y., Son, B. N., Seo, Y. I. & Lim, S. K. Comparison of four saliva detection methods to identify expectorated blood spatter. J. Forensic Sci. 60, 1571–1576 (2015).
Willott, G. M. An improved test for the detection of salivary amylase in stains. J. Forensic Sci. Soc. 14, 341–344 (1974).
Tsutsumi, H., Higashide, K., Mizuno, Y., Tamaki, K. & Katsumata, Y. Identification of saliva stains by determination of the specific activity of amylase. Forensic Sci. Int. 50, 37–42 (1991).
Gefrides, L. & Welch, K. In Forensic Biology: Serology and DNA, 2nd (ed. Mozayani, A. & Noziglia, C.) 20-21 (Springer Science+Business Media USA, 2011).
Hanson, E. K., Lubenow, H. & Ballantyne, J. Identification of forensically relevant body fluids using a panel of differentially expressed microRNAs. Anal. Biochem. 387, 303–314 (2009).
Fleming, R. I. & Harbison, S. The development of a mRNA multiplex RT-PCR assay for the definitive identification of body fluids. Forensic Sci. Int. Genet. 4, 244–256 (2010).
Courts, C. & Madea, B. Specific micro-RNA signatures for the detection of saliva and blood in forensic body-fluid identification. J. Forensic Sci. 56, 1464–1470 (2011).
Park, J. L. et al. Forensic body fluid identification by analysis of multiple RNA markers using NanoString technology. Genomics Inform. 11, 277–281 (2013).
Lee, H. Y. et al. Genome-wide methylation profiling and a multiplex construction for the identification of body fluids using epigenetic markers. Forensic Sci. Int. Genet. 17, 17–24 (2015).
Hoshino, T. et al. PCR detection and identification of oral streptococci in saliva samples using gtf genes. Diagn. Microbiol. Infect. Dis. 48, 195–199 (2004).
Nakanishi, H. et al. A novel method for the identification of saliva by detecting oral streptococci using PCR. Forensic Sci. Int. 183, 20–23 (2009).
Donaldson, A. E., Taylor, M. C., Cordiner, S. J. & Lamont, I. L. Using oral microbial DNA analysis to identify expirated blood spatter. Int. J. Legal Med. 124, 569–576 (2010).
Hanssen, E. N. et al. Body fluid prediction from microbial patterns for forensic application. Forensic Sci. Int. Genet. 30, 10–17 (2017).
Mackay, I. M., Arden, K. E. & Nitsche, A. Real-time PCR in virology. Nucleic Acids Res. 30, 1292–1305 (2002).
Aas, J. A., Paster, B. J., Stokes, L. N., Olsen, I. & Dewhirst, F. E. Defining the normal bacterial flora of the oral cavity. J. Clin. Microbiol. 43, 5721–5732 (2005).
Dewhirst, F. E. et al. The human oral microbiome. J. Bacteriol. 192, 5002–5017 (2010).
Gibbons, R. J. & van Houte, J. Selective bacterial adherence to oral epithelial surfaces and its role as an ecological determinant. Infect. Immun. 3, 567–573 (1971).
Bakri, I. M. & Douglas, C. W. Inhibitory effect of garlic extract on oral bacteria. Arch. Oral Biol. 50, 645–651 (2005).
Baydaş, B., Uslu, H., Yavuz, I., Ceylan, I. & Dağsuyu, I. M. Effect of a chronic nail-biting habit on the oral carriage of Enterobacteriaceae. Oral Microbiol. Immunol. 22, 1–4 (2007).
Vellappally, S., Fiala, Z., Smejkalova, J., Jacob, V. & Shriharsha, P. Influence of tobacco use in dental caries development. Cent. Eur. J. Public Health. 15, 116–121 (2007).
Ge, Y., Caufield, P. W., Fisch, G. S. & Li, Y. Streptococcus mutans and Streptococcus sanguinis colonization correlated with caries experience in children. Caries Res. 42, 444–448 (2008).
Signoretto., C. et al. Drinking habits are associated with changes in the dental plaque microbial community. J. Clin. Microbiol. 48, 347–356 (2010).
Fontana, C., Favaro, M., Pelliccioni, M., Pistoia, E. S. & Favalli, C. Use of the MicroSeq. 500 16S rRNA gene-based sequencing for identification of bacterial isolates that commercial automated systems failed to identify correctly. J. Clin. Microbiol. 43, 615–619 (2005).
Lau, S. K. et al. Usefulness of the MicroSeq. 500 16S rDNA bacterial identification system for identification of anaerobic Gram positive bacilli isolated from blood cultures. J. Clin. Pathol. 59, 219–222 (2006).
Burton, J. P., Wescombe, P. A., Moore, C. J., Chilcott, C. N. & Tagg, J. R. Safety assessment of the oral cavity probiotic Streptococcus salivarius K12. Appl. Environ. Microbiol. 72, 3050–3053 (2006).
Okahashi, N. et al. Pili of oral Streptococcus sanguinis bind to salivary amylase and promote the biofilm formation. Microb. Pathog. 50, 148–154 (2011).
Kaplan, J. B. & Fine, D. H. Biofilm dispersal of Neisseria subflava and other phylogenetically diverse oral bacteria. Appl. Environ. Microbiol. 68, 4943–4950 (2002).
Suzuki, N., Yoshida, A. & Nakano, Y. Quantitative analysis of multi-species oral biofilms by TaqMan Real-Time PCR. Clin. Med. Res. 3, 176–185 (2005).
Tobe, S. S. et al. A proof of principal study on the use of direct PCR of semen and spermatozoa and development of a differential isolation protocol for use in cases of alleged sexual assault. Int. J. Legal Med. 131, 87–94 (2017).
Chen, M. et al. The impact of different DNA extraction methods on the analysis of microbial diversity of oral saliva from healthy youths by polymerase chain reaction-denaturing gradient gel electrophoresis. J. Dental Sci. 11, 54–58 (2016).
Salazar, O. & Asenjo, J. A. Enzymatic lysis of microbial cells. Biotechnol. Lett. 29, 985–994 (2007).
Virkler, K. & Lednev, I. K. Analysis of body fluids for forensic purposes: from laboratory testing to non-destructive rapid confirmatory identification at a crime scene. Forensic Sci. Int. 188, 1–17 (2009).
Giampaoli, S. et al. Molecular identification of vaginal fluid by microbial signature. Forensic Sci. Int. Genet. 6, 559–564 (2012).
Pollack, S., Mogtader, A. & Lange, M. Neisseria subflava endocarditis. Case report and review of the literature. Am. J. Med. 76, 752–758 (1984).
Baraldès, M. A. et al. Meningitis due to Neisseria subflava: case report and review. Clin. Infect. Dis. 30, 615–617 (2000).
Nijjer, S. & Dubrey S. W. Streptococcus sanguis endocarditis associated with colonic carcinoma. BMJ Case Rep. 2010; 2010.
Kaci, G. et al. Anti-inflammatory properties of Streptococcus salivarius, a commensal bacterium of the oral cavity and digestive tract. Appl. Environ. Microbiol. 80, 928–934 (2014).
Casey, D. G. & Price, J. The sensitivity and specificity of the RSID-saliva kit for the detection of human salivary amylase in the Forensic Science Laboratory, Dublin, Ireland. Forensic Sci. Int. 194, 67–71 (2010).
Jung, J. Y. et al. A simple method of VNTR D1S80 locus allelic ladder construction for capillary electrophoresis-based genotyping. J. Forensic Sci. 63, 526–529 (2018).
Parson, W., Niederstatter, H., Kochl, S., Steinlechner, M. & Berger, B. When autosomal short tandem repeats fail: optimized primer and reaction design for Y-chromosome short tandem repeat analysis in forensic casework. Croat. Med. J. 42, 285–257 (2001).
Purps, J., Geppert, M., Nagy, M. & Roewer, L. Validation of a combined autosomal/Y-chromosomal STR approach for analyzing typical biological stains in sexual-assault cases. Forensic Sci. Int. Genet. 19, 238–242 (2015).
Jung, J. Y. et al. Forensic genetic study of 29 Y-STRs in Korean population. Leg. Med. (Tokyo). 23, 17–20 (2016).
An, J. H., Shin, K. J., Yang, W. I. & Lee, H. Y. Body fluid identification in forensics. BMB Rep. 45, 545–553 (2012).
An, J. H., Choi, A., Shin, K. J., Yang, W. I. & Lee, H. Y. DNA methylation-specific multiplex assays for body fluid identification. Int. J. Legal Med. 127, 35–43 (2013).
Walsh, D. J. et al. Isolation of deoxyribonucleic acid (DNA) from saliva and forensic science samples containing saliva. J. Forensic Sci. 37, 387–395 (1992).
Ali, M. M. et al. PCR applications in identification of saliva samples exposed to different conditions (streptococci detection based). Pak. J. Biol. Sci. 16, 575–579 (2013).
Lee, J. W., Jung, J. Y. & Lim, S. K. Simple and rapid identification of saliva by detection of oral streptococci using direct polymerase chain reaction combined with an immunochromatographic strip. Forensic Sci. Int. Genet. 33, 155–160 (2018).
Walker, G. V., Heng, N. C., Carne, A., Tagg, J. R. & Wescombe, P. A. Salivaricin E and abundant dextranase activity may contribute to the anti-cariogenic potential of the probiotic candidate Streptococcus salivarius JH. Microbiology. 162, 476–486 (2016).
Lowther, W. T. & Matthews, B. W. Structure and function of the methionine aminopeptidases. Biochim. Biophys. Acta. 1477, 157–167 (2000).
Li, Y., Pan, Y., Qi, F. & Caufield, P. W. Identification of Streptococcus sanguinis with a PCR-generated species-specific DNA probe. J. Clin. Microbiol. 41, 3481–3486 (2003).
Boufous, el. H. & Vadeboncoeur, C. Purification and characterization of the Streptococcus salivarius methionine aminopeptidase (MetAP). Biochimie. 85, 993–997 (2003).
Acknowledgements
This work was supported by the National Forensic Service (NFS2018DNA03).
Author information
Authors and Affiliations
Contributions
J.Y.J. and S.K.L. designed the study. H.K.Y., S.A., E.R.A., H.C.P, and K.L. performed experiments related to development of the kit. J.Y.J., J.W.L., Y.J.K., and J.H.H. performed experiments related to evaluation of the kit and its forensic applications. H.K.Y. drafted sections of the manuscript related to the development of the kit. J.Y.J. performed most of the analysis and wrote the manuscript. S.K.L. revised the manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Jung, J.Y., Yoon, H.K., An, S. et al. Rapid oral bacteria detection based on real-time PCR for the forensic identification of saliva. Sci Rep 8, 10852 (2018). https://doi.org/10.1038/s41598-018-29264-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-29264-2
This article is cited by
-
Simultaneous SERS-decoding detection of multiple pathogens in drinking water with home-made portable double-layer filtration and concentration device
Microchimica Acta (2024)
-
A review of metallic nanostructures against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)
Toxicology and Environmental Health Sciences (2023)
-
A Review on Microbial Species for Forensic Body Fluid Identification in Healthy and Diseased Humans
Current Microbiology (2023)
-
Development and application of a multiplex PCR system for forensic salivary identification
International Journal of Legal Medicine (2023)
-
Rapid and visual detection of specific bacteria for saliva and vaginal fluid identification with the lateral flow dipstick strategy
International Journal of Legal Medicine (2023)