Introduction

Coherent control was originally developed for controlling chemical reactions using coherent two-photon processes, in which an electronic excited state was used as an intermediary to assist the chemical reaction to the electronic ground-state potential surface1,2,3. Coherent control has been performed for other physical properties, for example, electronic, vibrational and rotational states of atoms and molecules4,5,6,7,8,9,10,11,12 and excitons, spins, and phonons in the solid state13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29 and the superconducting electrical circuits30,31,32.

The coherent control of optical phonons was first demonstrated in the molecular crystals at cryogenic temperature using multiple femtosecond pulses21. This was well explained by an impulsive stimulated Raman scattering (ISRS) mechanism to generate the coherent optical phonon. However, the similar coherent control experiments with double femtosecond pulses were performed on semimetal films23 to be explained by a displacive excitation mechanism33,34. To understand the unified generation mechanism of coherent phonons, the microscopic theory based on quantum dynamics is required35,36,37,38. However, in the coherent control experiment, the amplitude and phase dependences have been not yet understood from these microscopic theories.

The aim of this paper is to theoretically propose the unified process included the generation and detection of the coherent optical phonons from quantum dynamics under a two-electronic-level and a displaced harmonic oscillator model under the off-resonant condition to extend ref.36. The effect of detuning and the control scheme are discussed. In addition, we demonstrate the coherent control of 40 THz optical phonons in diamond using a pair of sub-10-fs optical pulses by the ISRS process since the band gap of diamond is well above the energy of a commonly used femtosecond laser pulse.

As an application to quantum information technology, diamond is expected to be applied to quantum memory using the nitrogen or silicon-vacancy center in diamond15,39,40,41 and the optical phonon42,43,44,45 since the high-purity material is available and it is working at room temperature. On the other hand, the phonon property of diamond has been discussed in the context of photophysics46,47,48,49. To understand the coherence of the optical phonon fundamentally and practically, our coherent control scheme might be helpful.

Results

Two-electric-level coherent-phonon generation and detection model

It was shown that the generation and detection processes of coherent phonons can be described by the two-band density matrix formalism with the optical response function50. It was assumed that the band-gap energy is modulated by the coherent oscillation of the optical phonon due to the deformation potential interaction. In the case of excitation to the transparent wavelength region in diamond treated in the present work, we may adopt a much simplified version of this theory.

Let us consider a two-level system for the electronic state coupled with a harmonic oscillator36,51. The Hamiltonian is given by

$$\begin{array}{rcl}{H}_{0} & = & {H}_{g}|g\rangle \langle g|+(\,{\in }+{H}_{e})|e\rangle \langle e|,\\ {H}_{g} & = & \hslash \omega {b}^{\dagger }b,\\ {H}_{e} & = & \hslash \omega {b}^{\dagger }b+\alpha \hslash \omega (b+{b}^{\dagger }),\end{array}$$
(1)

where the state vector |g〉 refers to the electronic ground state of the crystal, and |e〉 refers to the electronic excited state with the excitation energy . In the case of diamond, |e〉 corresponds representatively to the electronic states above the direct band gap, and is approximately equal to the direct band gap energy 7.3 eV52,53.

The Hamiltonian H g and H e are the phonon Hamiltonians in the subspaces |g〉 and |e〉. Here we have introduced the annihilation and the creation operator b and b for the interaction mode50 which is defined as a linear combination of the normal modes lying close to the Γ point in the Brillouin zone. Because of the phase-matching condition, the wave vector of the phonon is equal to the wave vector of the incident photon modulated by the by refractive index of the crystal. In the case of coherent phonons, the incident pulse is decomposed into a linear combination of plane waves around the central mode. Therefore, the wave vector of the coherent phonon is also distributed over a small region around Γ point in the Brillouin zone. The dispersion of the optical phonon energy near the Γ point is neglected, and we set the energy of the interaction mode \(\hslash \omega \) is equal to the optical phonon energy at Γ point. In the case of diamond, ω is evaluated as ~2π × 40 THz48,49. Note that the transverse and longitudinal optical phonon cannot be distinguished at Γ point because of a non-polar material. The dimensionless coupling constant is denoted by α. In the bulk crystal, the Huang–Rhys factor α2 is considered to be small; \({\alpha }^{2}\ll 1\). For simplicity, we consider a four-state model with two phonon states for each electronic state: |g, 0〉 and |g, 1〉 for phonon Fock states with n = 0 and 1 in the electronic ground state and |e, 0〉 and |g, 1〉 for those in the electronic excited state. The interaction Hamiltonian with the optical pulse is given by

$${H}_{I}=\mu {E}_{0}f(t)({e}^{-i{\rm{\Omega }}t}|e\rangle \langle g|+{e}^{i{\rm{\Omega }}t}|g\rangle \langle e|),$$
(2)

in which μ is the transition dipole moment from |g〉 to |e〉, and E0, Ω and f(t) are the strength, central frequency and temporal profile of the electric field of the pump pulse, respectively. The time evolution of the density operator was obtained by solving the quantum Liouville equation using a perturbative expansion in the lowest order.

We restricted the well separated pulses for the two pump pulses (pump 1 and pump 2) and the probe pulse. Then the generation and detection processes were separately treated, which corresponded to a doorway-window picture in nonlinear spectroscopy51,54. When pump 1 and 2 were well separated, the excitation of the optical phonons occurred with each pulse. The pathway of electronic excitation by pump 1 and the deexcitation by pump 2 was not allowed for the off-resonant condition. We set the initial state in |g, 0〉, then \(\rho (\,-\,\infty )=|g,\,0\rangle \langle g,\,0|\). This was reasonable for the diamond case, because the population number in the n = 1 state was approximately 0.005 at 300 K. There were four Liouville pathways for the exciting phonon polarization: \(|g,0\rangle \,\langle g,0|\to |e,0\rangle \,\langle g,0|\to |g,1\rangle \,\langle g,0|\), \(|g,0\rangle \,\langle g,0|\to |e,1\rangle \,\langle g,0|\to |g,1\rangle \,\langle g,0|\) and Hermitian conjugates for each pump pulse.

The density operator for the excitation by pump 1 \({\rho }_{1}^{\mathrm{(2)}}(t)\) was obtained as

$$\begin{array}{rcl}{\rho }_{1}^{\mathrm{(2)}}(t) & = & \alpha \frac{{\mu }^{2}|{E}_{1}{|}^{2}}{{\hslash }^{2}}{e}^{-i\omega t}{\int }_{-\infty }^{\infty }dt^{\prime} {\int }_{-\infty }^{t^{\prime} }dt^{\prime\prime} {f}_{1}(t^{\prime} ){f}_{1}(t^{\prime\prime} )\\ & & \times \,({e}^{i\omega t^{\prime} }-{e}^{i\omega {t}^{^{\prime\prime} }}){e}^{-i{\rm{\Delta }}(t^{\prime} -{t}^{^{\prime\prime} })}|g,\,1\rangle \langle g,\,0|,\end{array}$$
(3)

where |E1| is the strength of the electric field of pump 1, \({\rm{\Delta }}\equiv {\in }\,/\hslash -{\rm{\Omega }}\) is the detuning, and we assumed that t is well after the passage of the pump pulse.

In the case for far off-resonance excitation, the density matrix can be evaluated as follows. For simplicity, we assume a Gaussian pulse with pulse-width σ,

$$f(t)=\frac{1}{\sqrt{\pi }\sigma {\rm{\Omega }}}\exp (-\frac{{t}^{2}}{{\sigma }^{2}}),$$
(4)

where Ω is used to make the normalization factor, \(\sqrt{\pi }\sigma {\rm{\Omega }}\), dimensionless. Following the calculations to ref.36, we obtain

$${\rho }_{1}^{\mathrm{(2)}}(t)=i\alpha \frac{{\mu }^{2}|{E}_{1}{|}^{2}}{{\hslash }^{2}}{e}^{-i\omega t}\frac{\omega }{\sqrt{2}\sigma {{\rm{\Omega }}}^{2}{{\rm{\Delta }}}^{2}}{e}^{-{\sigma }^{2}{\omega }^{2}\mathrm{/8}}|g,\,1\rangle \langle g,\,0|\mathrm{.}$$
(5)

The density operator for the excitation by pump 2, \({\rho }_{2}^{\mathrm{(2)}}(t)\), was obtained in a similar calculation, and we obtain the density operator \({\rho }^{\mathrm{(2)}}(t)={\rho }_{1}^{\mathrm{(2)}}(t)+{\rho }_{2}^{\mathrm{(2)}}(t)\)

$$\begin{array}{rcl}{\rho }^{\mathrm{(2)}}(t) & = & i\alpha \frac{{\mu }^{2}}{{\hslash }^{2}}\frac{\omega }{\sqrt{2}\sigma {{\rm{\Omega }}}^{2}{{\rm{\Delta }}}^{2}}{e}^{-{\sigma }^{2}{\omega }^{2}\mathrm{/8}}\\ & & \times \,({|{E}_{1}|}^{2}{e}^{-i\omega t}+{|{E}_{2}|}^{2}{e}^{-i\omega (t-\tau )})|g,\,1\rangle \langle g,\,0|\\ & = & iA({|{E}_{1}|}^{2}+{|{E}_{2}|}^{2}{e}^{i\omega \tau })\times {e}^{-i\omega t}|g,\,1\rangle \langle g,\,0|,\end{array}$$
(6)

where

$$A\equiv \alpha \frac{{\mu }^{2}}{{\hslash }^{2}}\frac{\omega }{\sqrt{2}\sigma {{\rm{\Omega }}}^{2}{{\rm{\Delta }}}^{2}}{e}^{-{\sigma }^{2}{\omega }^{2}\mathrm{/8}},$$
(7)

τ is the delay between the pump 1 and the pump 2 (pump-pump delay), and E2 is the electric field strength of pump 2.

The coherent phonon dynamics can be investigated by calculating the mean value of the phonon coordinate \(\langle Q(t)\rangle ={\rm{Tr}}\{Q{\rho }^{\mathrm{(2)}}(t)\}\), where \(Q\equiv \sqrt{\hslash \mathrm{/2}\omega }(b+{b}^{\dagger })\) and Tr indicate the trace. By considering the Hermitian conjugated paths, we obtain

$$\begin{array}{rcl}\langle Q(t)\rangle & = & \sqrt{\frac{\hslash }{2\omega }}\alpha \frac{{\mu }^{2}}{{\hslash }^{2}}\frac{\omega }{\sqrt{2}\sigma {{\rm{\Omega }}}^{2}{{\rm{\Delta }}}^{2}}{e}^{-{\sigma }^{2}{\omega }^{2}\mathrm{/8}}\\ & & \times \,\{{|{E}_{1}|}^{2}\,\sin (\omega t)+{|{E}_{2}|}^{2}\,\sin (\omega (t-\tau )\}\\ & = & \sqrt{\frac{\hslash }{2\omega }}A\{{|{E}_{1}|}^{2}\,\sin (\omega t)+{|{E}_{2}|}^{2}\,\sin (\omega (t-\tau )\}\mathrm{.}\end{array}$$
(8)

Therefore, the amplitude of the phonon oscillation controlled by the two short pulses is expressed by a sum of the two sinusoidal functions. The phonon amplitude is enhanced by two times or canceled when the pump delay matches an integer or half-integer multiple of the vibrational period through constructive or destructive interference, respectively, at the \(|{E}_{1}|=|{E}_{2}|\) condition. Note that the amplitude of oscillation is inversely proportional to the square of detuning from the excited state.

When the heterodyne detection of the transmitted light is investigated, the detection intensity I h (t) should be

$${I}_{h}(t)={\rm{\Omega }}l\times {\rm{Im}}[{E}_{3}^{\ast }(t){P}_{s}(t)],$$
(9)

where E3(t) is the strength of the electronic field of the probe pulse, P s (t) is the polarization at time t, and l is the thickness of the sample51. The probe pulse irradiates the sample at delay t p . There are eight Liouville pathways for the exciting phonon polarization:

$$\begin{array}{lll}{\bf{path}} & 1{\boldsymbol{:}} & |g,\,1\rangle \langle g,\,0|\to |e,\,1\rangle \langle g,\,0|\to |g,\,0\rangle \langle g,\,0|,\\ {\bf{path}} & 2{\boldsymbol{:}} & |g,\,1\rangle \langle g,\,0|\to |e,\,0\rangle \langle g,\,0|\to |g,\,0\rangle \langle g,\,0|,\\ {\bf{path}} & 3{\boldsymbol{:}} & |g,\,1\rangle \langle g,\,0|\to |g,\,1\rangle \langle e,\,1|\to |g,\,1\rangle \langle g,\,1|,\\ {\bf{path}} & 4{\boldsymbol{:}} & |g,\,1\rangle \langle g,\,0|\to |g,\,1\rangle \langle e,\,0|\to |g,\,1\rangle \langle g,\,1|,\end{array}$$

and their Hermitian conjugates.

We obtain \({\rho }_{1}^{\mathrm{(3)}}(t^{\prime} )\) for the path 1 as

$$\begin{array}{rcl}{\rho }_{1}^{\mathrm{(3)}}(t^{\prime} ) & = & iA({|{E}_{1}|}^{2}+{|{E}_{2}|}^{2}{e}^{i\omega \tau })\frac{i\mu }{\hslash }{E}_{3}{e}^{-i\omega {t}_{p}}\\ & & \times \,{\int }_{-\infty }^{t^{\prime} }dt^{\prime\prime} {f}_{3}(t^{\prime\prime} ){e}^{-i\omega {t}^{^{\prime\prime} }}{e}^{-i{\rm{\Omega }}{t}^{^{\prime\prime} }}{e}^{-i(\varepsilon +\hslash \omega )(t^{\prime} -{t}^{^{\prime\prime} })/\hslash }\\ & & \times \,|e,\,1\rangle \langle g,\,0|,\end{array}$$
(10)

where f3(t″) is the Gaussian pulse and t p is the pump-probe delay. For the polarization operator \({P}^{op}=\mu |g\rangle \langle e|+{\mu }^{\ast }|e\rangle \langle g|\), the complex polarization at time t is given by \(P(t)={\rm{Tr}}\{{\rho }^{\mathrm{(3)}}(t){P}^{op}\}\). Then the polarization (P1(t′)) for the path 1 is given by

$$\begin{array}{rcl}{P}_{1}(t^{\prime} ) & = & \alpha A({|{E}_{1}|}^{2}+{|{E}_{2}|}^{2}{e}^{i\omega \tau })\frac{{\mu }^{2}}{\hslash }{E}_{3}{e}^{-i\omega {t}_{p}}\\ & & \times \,{\int }_{-\infty }^{t^{\prime} }dt^{\prime\prime} {f}_{3}(t^{\prime\prime} ){e}^{-i\omega {t}^{^{\prime\prime} }}{e}^{-i{\rm{\Omega }}{t}^{^{\prime\prime} }}{e}^{-i(\varepsilon +\hslash \omega )(t^{\prime} -{t}^{^{\prime\prime} })/\hslash },\end{array}$$
(11)

and the time-integrated intensity, I1(t p ), of the product between the probe light and polarization is

$$\begin{array}{rcl}{I}_{1}({t}_{p}) & = & {\int }_{-\infty }^{\infty }{E}_{3}\,{f}_{3}^{\ast }(t^{\prime} ){P}_{1}(t^{\prime} )dt^{\prime} \\ & = & \alpha A(|{E}_{1}{|}^{2}+|{E}_{2}{|}^{2}{e}^{i\omega \tau })\frac{{\mu }^{2}}{\hslash }|{E}_{3}{|}^{2}{e}^{-i\omega {t}_{p}}\\ & & \times \,{\int }_{-\infty }^{\infty }dt^{\prime} {\int }_{-\infty }^{t^{\prime} }dt^{\prime\prime} {f}_{3}(t^{\prime} ){e}^{i{\rm{\Omega }}t^{\prime} }{f}_{3}(t^{\prime\prime} ){e}^{-i\omega {t}^{^{\prime\prime} }}\\ & & \times \,{e}^{-i{\rm{\Omega }}{t}^{^{\prime\prime} }}{e}^{-i(\varepsilon +\hslash \omega )(t^{\prime} -{t}^{^{\prime\prime} })/\hslash }\mathrm{.}\end{array}$$
(12)

Using the Gaussian pulse (4), we obtain

$$\begin{array}{rcl}{I}_{1}({t}_{p}) & = & \alpha A(|{E}_{1}{|}^{2}+|{E}_{2}{|}^{2}{e}^{i\omega \tau })\frac{{\mu }^{2}}{\hslash \pi {\sigma }^{2}{{\rm{\Omega }}}^{2}}|{E}_{3}{|}^{2}{e}^{-i\omega {t}_{p}}\\ & & \times \,{\int }_{-\infty }^{\infty }{e}^{-2{s}^{2}/{\sigma }^{2}}{e}^{-i\omega s}ds{\int }_{0}^{\infty }du{e}^{-{u}^{2}\mathrm{/(2}{\sigma }^{2})}{e}^{i({\rm{\Delta }}-\omega \mathrm{/2)}u}\\ & \approx & (|{E}_{1}{|}^{2}+|{E}_{2}{|}^{2}{e}^{i\omega \tau })\frac{{\mu }^{2}}{\hslash \pi {\sigma }^{2}{{\rm{\Omega }}}^{2}}|{E}_{3}{|}^{2}\\ & & \times \,{e}^{-i\omega {t}_{p}}\frac{\sqrt{\pi }}{\sqrt{2}\sigma }{e}^{-{\sigma }^{2}{\omega }^{2}\mathrm{/8}}\frac{i\alpha A}{{\rm{\Delta }}-\omega \mathrm{/2}}\\ & = & iB(|{E}_{1}{|}^{2}+|{E}_{2}{|}^{2}{e}^{i\omega \tau }){e}^{-i\omega {t}_{p}}\frac{1}{{\rm{\Delta }}-\omega \mathrm{/2}},\end{array}$$
(13)

where \(s\equiv (t^{\prime} +t^{\prime\prime} )\mathrm{/2,}\,u\equiv t^{\prime} -t^{\prime\prime} \), and

$$B\equiv \frac{\sqrt{\pi }\omega {\alpha }^{2}{\mu }^{2}}{2{\sigma }^{2}{{\rm{\Omega }}}^{4}{{\rm{\Delta }}}^{2}{\hslash }^{3}}|{E}_{3}{|}^{2}{e}^{-{\omega }^{2}{\sigma }^{2}\mathrm{/4}}\mathrm{.}$$
(14)

A similar calculation shows that \({I}_{4}({t}_{p})={I}_{1}({t}_{p})\) and

$$\begin{array}{rcl}{I}_{2}({t}_{p}) & = & {I}_{3}({t}_{p})\\ & = & -iB(|{E}_{1}{|}^{2}+|{E}_{2}{|}^{2}{e}^{i\omega \tau }){e}^{-i\omega {t}_{p}}\frac{1}{{\rm{\Delta }}+\omega \mathrm{/2}}\mathrm{.}\end{array}$$
(15)

Then we find

$$\begin{array}{rcl}I({t}_{p}) & = & \sum {I}_{i}({t}_{p})\\ & = & (|{E}_{1}{|}^{2}+|{E}_{2}{|}^{2}{e}^{i\omega \tau }){e}^{-i\omega {t}_{p}}\frac{2iB\omega }{{{\rm{\Delta }}}^{2}}\mathrm{.}\end{array}$$
(16)

By considering the Hermitian conjugate paths, the time-integrated intensity of the heterodyne detection I h (τ, t p ) is given by

$$\begin{array}{rcl}{I}_{h}(\tau ,{t}_{p}) & = & \frac{\sqrt{\pi }{\omega }^{2}{\alpha }^{2}{\mu }^{2}}{{\sigma }^{2}{{\rm{\Omega }}}^{4}{{\rm{\Delta }}}^{4}{\hslash }^{3}}|{E}_{3}{|}^{2}{e}^{-{\omega }^{2}{\sigma }^{2}\mathrm{/4}}\\ & & \times \,\{|{E}_{1}{|}^{2}\,\sin (\omega {t}_{p})+|{E}_{2}{|}^{2}\,\sin (\omega ({t}_{p}-\tau ))\}\\ & = & C(\tau )\sin (\omega {t}_{p}-{\rm{\Theta }}(\tau )),\end{array}$$
(17)

where

$$\begin{array}{ccc}C(\tau ) & = & \frac{\sqrt{\pi }{\omega }^{2}{\alpha }^{2}{\mu }^{2}}{{\sigma }^{2}{{\rm{\Omega }}}^{4}{{\rm{\Delta }}}^{4}{\hslash }^{3}}|{E}_{3}{|}^{2}{e}^{-{\omega }^{2}{\sigma }^{2}/4}\\ & & \times \,|{E}_{1}{|}^{2}\sqrt{1+2\frac{|{E}_{2}{|}^{2}}{|{E}_{1}{|}^{2}}\,\cos (\omega \tau )+{(\frac{|{E}_{2}{|}^{2}}{|{E}_{1}{|}^{2}})}^{2}},\end{array}$$
(18)
$${\rm{\Theta }}(\tau )=\arctan (\frac{\sin (\omega \tau )}{\cos (\omega \tau )+\frac{|{E}_{2}{|}^{2}}{|{E}_{1}{|}^{2}}}).$$
(19)

The present model calculation clearly shows that the response of the transmitted light intensity measured with heterodyne detection exhibits the same dependence on the pump delay as that of the mean value of the phonon coordinate.

Single-pump transmission experiment

In the followings, the experimental detection of the optical phonons was performed using a pump-probe type transient transmittance measurement with femtosecond pump pulses, see the details in Methods. The transient transmittance change induced by only pump 1 or pump 2 were measured in Fig. 1(a,b), respectively, against the pump-probe delay t p between −200 and 1000 fs. It is noted that time zero was set at the time when pump 2 irradiates the sample; the minimum portion of the sharp response. After the sharp peak, which arose from the nonlinear response for overlapped pump and probe pulses, there was a modulation caused by the coherent optical phonons in diamond. The oscillation period was 25.1 ± 0.03 fs (frequency of 39.9 ± 0.05 THz). The coherent oscillation in the transmitted pulse intensity arising from the optical phonons was the same as that obtained by the reflection experiments48,49.

Figure 1
figure 1

Transient transmittance change of diamond. The oscillation (a) is excited by the pump 1 only, and the oscillation (b) is excited by the pump 2 only. It is noted that the baseline in our previous experiment49 seems to more flat compared to the present one. This is because the experimental data shown in ref.49 has been already subtracted by the smoothing curve of the obtained experimental data to easily analyze this.

To verify the theoretical treatment on the detection process in the previous section, Fig. 2 shows a pump laser power dependence of the oscillation amplitude of the 40 THz oscillation in the transmittance spectrum. According to Eq. (17) with \(|{E}_{2}{|}^{2}=0\), the oscillation amplitude is a linear dependence on the pump laser intensity |E1|2. This is well agreement with our experiment data. It is noted that the deviation between our prediction and experimental data has not yet been identified such as the laser power and measurement-setup stability.

Figure 2
figure 2

The pump power dependence of the amplitude of the 40 THz oscillation. It is noted that the statistical average was 4,800 signals.

Coherent control experiment

Figure 3 shows typical examples of the transient transmittance changes induced by the pair of pump pulses (pump 1 and 2). Pump 1 induces a coherent oscillation in the transmission intensity with a frequency of 39.9 ± 0.05 THz. This oscillation amplitude was controlled by pump 2. It was reduced at τ = 237.9 fs, enhanced at τ = 251.4 fs, and reduced again at τ = 263.9 fs. The oscillation amplitude after pump 2 was obtained by fitting a sinusoidal wave in the range of the pump 2-probe delay between 200 and 650 fs. In this time range, the decrease of the amplitude was negligibly small. The obtained amplitude was plotted along the separation time τ in Fig. 4(a). We also estimated the initial phase of the oscillation after pump 2 by extrapolation of the fitted sinusoidal function at the timing of the pump 2 irradiation. The estimated initial phase is plotted in Fig. 4(b). Measurement error to define the timing of the pump 2 irradiation was approximately ±0.5 fs, which corresponds to ±0.04π for the phase of the 39.9 THz oscillation.

Figure 3
figure 3

Transient transmittance change along the pump-probe delay (between pump 2 and the probe) for several pump-pump delays (τ between pump 1 and pump 2): at 237.9 fs (a), 242.4 fs (b), 251.4 fs (c), 259.4 fs (d), and 263.9 fs (e). In this figure, the time zero is set at the timing of the pump 2 irradiation. Each curve is plotted with vertical offsets.

Figure 4
figure 4

The amplitude (a) and phase (b) of the controlled oscillation after pump 2 against the pump-pump delay τ. The amplitude is normalized using that obtained after excitation after only pump 1; oscillation between the pump 1 and pump 2 irradiation timing. Solid circles are the experimental data and the solid curves are obtained by calculation using Eqs (18) and (19) with \({|{E}_{2}|}^{2}/{|{E}_{1}|}^{2}=1.09\), \(\omega =2\pi \times 39.9\) THz, and the offset initial phase −0.29π.

In Fig. 4, the phonon amplitude was normalized by the phonon amplitude excited by pump 1, which was observed at the pump 2-probe delay between −270 and 0 fs. The phonon amplitude was enhanced almost twice at τ = 251.4 fs and diminished at τ = 237.9 fs by the constructive and destructive interference of phonon states.

The energy of the optical pulses (around 1.5 eV) was well below the direct band gap (7.3 eV) of diamond52,53. Therefore, the coherent optical phonons should be excited by the ISRS process36 at an off-resonant condition. The initial phonon state at room temperature was well expressed with the n = 0 state, because the phonon energy (39.9 THz \(\simeq \,135\) meV) was higher than the thermal energy (~25 meV) and the population ratio between the ground and excited state of the optical phonon was 0.005. The coherent control of the phonon amplitude shown in Fig. 4 was calculated using our proposed model (15). In this experiment, the intensity ratio between the light intensities of pump 1 and 2 was \(|{E}_{2}{|}^{2}/|{E}_{1}{|}^{2}=1.09\) and approximately agreed with the amplitude ratio of the coherent phonon, \({\rm{\Delta }}{T}_{2}/{\rm{\Delta }}{T}_{1}=0.99\pm 0.03\) according to the single-pump experiment in Fig. 1. The transmission intensity change depending on the pump-pump delay τ was calculated using Eq. (17) and the frequency (\(\omega =2\pi \times 39.9\) THz) for the optical phonon of diamond. The calculated result is shown in Fig. 4(a), where the intensity was normalized to that induced by a single pump pulse (pulse 1). The initial phase of the oscillation after irradiation of pump 2 was also obtained from the calculation and shown in Fig. 4(b). Our proposed model for the coherent control of the optical phonons reasonably represents the experimental data. It is noted that the initial phase shift −0.29π, which corresponds to 3.6 fs, does not be explained in our proposed model. This may come from the calibration error of the pump-pump delay and the unknown mechanism of the phonon generation timing.

Although the phonon amplitude was not directly observed, the observed transmission intensity change (17) by heterodyne detection has the same pump-delay dependence (8) for the phonon amplitude. If the Huang-Rhys factor and the transition dipole were obtained from other experiments or calculations, the phonon amplitude can be estimated from the transient transmittance change. The phonon coherence induced by the pump pulse was detected by heterodyne detection. The coherent control by two separated pulses was expressed as the phonon coherences induced by each pump pulse (pump 1 and pump 2) interfering with each other.

Discussions

In summary, we investigated the coherent control of the optical phonons using a pair of optical pulses with two electronic levels and two harmonic phonon levels. The calculations showed that the controlled phonon amplitude and transmission intensity can be expressed by the sum of two sinusoidal functions. Furthermore, we demonstrated a coherent control of the optical phonons in a single crystal diamond. We used a pump and probe protocol and the change in the transmitted light intensity was determined with heterodyne detection. The phonon amplitude was coherently controlled by changing the pump-pump delay from 230 fs to 270 fs. The control scheme was well explained by our theoretical generation and detection model with the interference between the two phonon states excited by each pump pulse.

The wave packet dynamics of the coherent optical phonons is only measured in the transmission intensity change. Therefore, the amplitude and the phase of the wave packet cannot be individually controlled. To reproduce the wave packet of the coherent phonon, the transmittance and reflectivity changes should be simultaneously measured. According to the Kramers-Krönig relation, the transient complex dielectric constant can be measured. The optical phonon amplitude is also measured by combining to the Raman spectroscopy. Furthermore, there still are open questions on the nonlinear response of the optical phonon. The coherent control of the optical phonon around τ ~ 0 except for the pulse overlap region might give an insight on generation and detection processes for the optical phonon.

Methods

The experimental setup has been described in the previous paper49 in addition to that the optical pulses were generated by using a home-made Michelson-type interferometer28. While the transient reflectivity change was measured in ref.49, in this experiment, the transient transmittance change is measured. According to Fig. 5, the ultrafast laser conditions measured immediately behind the output port were a maximum-intensity wavelength of 792 nm with a estimated pulse width of 8.2 fs as full width at half maximum under the assumption of the transform-limited pulse. This also has a repetition rate of 75 MHz. To reduce the statistical error, 3,200 signals were averaged and taken as the measured value. By converting the temporal motion of the scan delay unit to the pump-probe delay, the temporal evolution of the change in the transmitted light intensity, ΔT(td)/T0, was obtained. Here we used the heterodyne detection technique. The powers of the pump 1 and 2 and the probe were 19.1 mW, 20.8 mW, and 3.0 mW, respectively. The sample used was a single crystal of diamond with a [100] crystal plane, which was fabricated by chemical vapor deposition and obtained from EPD corporation. The type of diamond was intermediate between Ib and IIa and its size was 5 × 5 mm2 and 0.7 mm thick. The polarization of the pump and probe pulses were set along the [110] and [−110] axes, respectively.

Figure 5
figure 5

The measured spectrum property of ultrafast laser.