Introduction

Stomata are microscopic pores that mediate the uptake of CO2 and loss of water from terrestrial plant leaves1. Analyses of stomatal function were greatly facilitated by the development of a method for continuous, non-destructive quantification of stomatal conductance (gs), the Gaastra method2. The key to this method is to assume that air inside the leaf is saturated with water vapour, with the saturation vapour pressure (es) then calculated according to an exponential relationship with leaf temperature (Tl). With this assumption, g s can be calculated from measurements of the transpiration rate (E), the vapour pressure of the air outside the leaf (ea), and Tl, assuming boundary layer conductance (gb) is known2. Furthermore, once gs has been established, the intercellular CO2 concentration (c i ) can be calculated3,4. Knowing ci is useful for relating photosynthetic metabolism and water-use efficiency to environmental conditions. The Gaastra2 method of quantifying gs and ci has become standard practice in leaf gas exchange studies and is employed in all commercial gas exchange systems.

It has become a dogmatic assumption in the field of plant physiology that the intercellular vapour pressure (ei) is saturated. If ei becomes unsaturated under some conditions, this will cause a bias in estimations of gs and ci. The vapour pressure inside leaves cannot be measured directly, but in a few studies indirect techniques have been applied to address the question. Results have been mixed, with some authors finding evidence of unsaturation5,6,7,8,9, and others no such evidence10,11,12; thus, the question has remained unresolved for decades.

Here we present results from a new type of experiment aimed at quantifying ei (Fig. 1). The underlying theory and the accompanying system of equations are described in full in the Supplementary Material. As air passes over a C3 leaf, CO2 diffuses through the stomata into the intercellular air space, and from there into the chloroplast, where some of it is fixed by RuBisCO. During diffusion through liquid, CO2 can exchange its oxygen atoms with those in water, with the rate of exchange greatly accelerated by the enzyme carbonic anhydrase. The most relevant site for carbonic anhydrase in this diffusion pathway is thought to be at the chloroplast surface13. Of the CO2 that exchanges its oxygen atoms with water at the chloroplast surface, not all will be fixed by RuBisCO, and some will diffuse back to the intercellular air space. Therefore, the intercellular air space contains a mixture of CO2 that has diffused in from the atmosphere carrying δ18O signature δa, and CO2 that has diffused back from the chloroplast surface carrying δ18O signature δc. We use the symbol δi to refer to the δ18O of this CO2 mixture in the intercellular air space.

Figure 1
figure 1

Experimental design underlying our method for estimating the intercellular vapour pressure, ei. A twig was placed in the leaf cuvette of a Li-Cor 6400 portable photosynthesis system. The flow of air in and out of the cuvette was split and diverted to water vapour and CO2 spectroscopic isotope analysers. In the top panel, symbols and fluxes in red relate to CO2 and those in blue to water vapour. The middle panel shows the basic flow of calculations, and the bottom panel provides definitions for symbols and abbreviations.

Water at the evaporative sites of leaves becomes enriched in 18O during transpiration14, with the extent of enrichment described by the well-known Craig-Gordon equation15. Because chloroplasts are appressed against the cell walls lining the intercellular air spaces in C3 plants16, it can be assumed that the δ18O of water at the chloroplast surface is very close to that at the evaporative sites17. The resulting enrichment of 18O in water at the chloroplast surface sets up a catena of enrichment of δ18O in CO2, with that at the chloroplast surface being highest, that in the intercellular air spaces intermediate, and that in the ambient air lowest. Thus, under typical conditions, we expect to find the pattern, δc > δi > δa.

We combined measurements of the oxygen isotope composition of CO2 entering and exiting a leaf gas exchange cuvette with gas exchange parameters to estimate δi. This estimate of δi is sensitive to ci, and is therefore sensitive to gs, which is in turn sensitive to the assumed value of ei (Fig. 1). From concurrent measurements of the δ18O of transpired water, we simultaneously estimated δ18O of water at the evaporative sites lining the intercellular air spaces (δe). The δe is also sensitive to the assumed value of ei, but typically much less so than δi. We then calculated the δ18O of CO2 in equilibrium with δe, which we term δce. Keeping in mind that the true δi must reflect a mixture between δce and δa, we then increased the air vapour pressure deficit (D), to see if the apparent δi, calculated by assuming saturated ei, would remain bounded between δce and δa. Here and throughout the manuscript we present D as the difference between the saturation vapour pressure at air temperature (es(Ta)) and the air vapour pressure (ea). We prefer this formulation of D in this context because it provides a description of the evaporative demand of the air outside the leaf which does not depend on an assumed value of ei.

If δi exceeds δce when δa is well below δce, this indicates an error in the calculation of δi. Unsaturation of ei can cause this error. In the next step of our analysis, we solved for the ei that would be required for δc (calculated from δi) to be equal to δce. This allowed us to quantitatively estimate ei over a range of D. We used these estimates of ei to test the longstanding assumption that the vapour pressure of air inside leaves remains saturated even as the evaporative demand of the air outside the leaf increases.

Results and Discussion

The δa in our experiment, measured in the gas stream exiting the gas exchange cuvette, ranged from 12 to 27‰ (VSMOW). The δce ranged from 40 to 68‰ for J. monosperma and from 52 to 71‰ for P. edulis. Thus, as expected, δce was always substantially higher than δa. As described above, theory dictates that δi should lie between δa and δce. However, as D increased in the cuvette, we observed that the apparent δi became larger than δce, such that the difference between δce and δi became negative in both species (Fig. 2). Calculation of both parameters assumed saturation of ei. The increasingly negative values of δcei with increasing D indicate errors in the estimation of δi under high D; these errors can be reconciled by allowing ei to drop below saturation as D increased.

Figure 2
figure 2

The difference between the δ18O of CO2 in equilibrium with evaporative site water (δce) and the δ18O of CO2 in the intercellular air spaces (δi) plotted as a function of the air vapour pressure deficit (D) to which the leaf was exposed for J. monosperma (A) and P. edulis (B). The δi and δce were calculated assuming saturation of vapour pressure in the intercellular air spaces. Negative values of δcei are inconsistent with theoretical expectations in this context, and indicate that the assumption of saturation of intercellular vapour pressure, ei, was invalid.

Are there other possible explanations for δi becoming larger than δce at moderate to high D? We considered five possible alternative explanations: (1) decreasing effectiveness of carbonic anhydrase with decreasing leaf water potential, such that the δ18O of CO2 at the chloroplast surface might not be completely equilibrated with local water; (2) somewhat less 18O-enriched water at the chloroplast surface than that at the evaporative sites due to a Péclet effect18; (3) a fractionation factor for static diffusion of H218O through the stomatal pore of 32‰ rather than 28‰19,20,21; (4) an error associated with neglecting cuticular conductance in gas exchange calculations22,23; and (5) a bias in the measurement of Tl by the energy balance method. These possible alternative explanations are addressed in full in the Supplementary Material. In summary, none of them can account satisfactorily for observations of δi surpassing δce. Therefore, the most likely explanation remains that ei declined below saturation as D increased.

Next, we solved for the ei required for δc, the δ18O of CO2 at the chloroplast surface calculated from δi, to be equal to δce, the δ18O of CO2 at the chloroplast surface calculated from δe. This allowed us to quantitatively estimate ei. This calculation required an estimate of gmc, the conductance to CO2 from the intercellular air space to the site of carbonic anhydrase activity. We inferred values of gmc such that they resulted in estimates of ei near to saturation when D was lowest. Estimates of the relative humidity inside the leaf made by assuming these values of gmc are shown in Fig. 3. These estimates decreased as D increased in both species, declining to values in the range of 0.9 in J. monosperma and 0.8 in P. edulis. As a result of these departures of ei from saturation, our analysis indicated that ci could be underestimated by as much as 80 µmol mol−1, and gs by as much as 30 mmol m−2 s−1 (Fig. 4).

Figure 3
figure 3

Relative humidity in the intercellular air spaces inside the leaves of two semiarid conifer species plotted as a function of the air vapour pressure deficit (D) to which the leaves were exposed in the gas exchange cuvette for J. monosperma (A) and P. edulis (B). The relative humidity is defined as ei/es, where ei is the intercellular vapour pressure and es is the saturation vapour pressure at leaf temperature. A relative humidity of unity indicates saturation, and is denoted by the horizontal line within each panel. The analysis demonstrates clear evidence of unsaturation of the internal humidity, even at rather modest air vapour pressure deficits, for these semiarid conifers. A segmented regression analysis indicated a breakpoint in the regression for J. monosperma at air vapour pressure deficit of 1.6 kPa, below which the slope was not significant. Above 1.6 kPa for J. monosperma, the slope was estimated to be −0.021 kPa−1 (R2 = 0.35, P < 0.0001, n = 54). For P. edulis, no breakpoint was identified, and a slope of −0.049 kPa−1 was estimated (R2 = 0.49, P < 0.0001, n = 48).

Figure 4
figure 4

The difference between the intercellular CO2 concentration (ci) calculated without assuming saturation of intercellular vapour pressure (ei) and that calculated by the Li-Cor portable photosynthesis system assuming saturation of ei (A) and the difference between stomatal conductance (gs) calculated without assuming saturation of ei and that calculated by the Li-Cor portable photosynthesis system assuming saturation of ei (B) plotted against the relative humidity in the intercellular air spaces. The relative humidity inside the leaf on the x-axis was generated from calculations that did not assume saturation of ei.

To demonstrate the impact of choosing different values for gmc, we conducted a sensitivity analysis, in which we calculated the relative humidity inside the leaf (ei/es) for values of gmc twice those originally assigned and for values half those originally assigned. These estimates of ei/es are shown in Supplementary Figure 1. From this figure, one can see that doubling the assigned gmc shifted the range of ei/es estimates up, and halving it shifted the range of ei/es estimates down. However the shifts were not so large as to substantially alter our interpretation of the results. Thus, while it is clear that estimates of ei/es by our technique are sensitive to assigned values of gmc, they are not hypersensitive, and our conclusion that ei/es declined well below unity at moderate to high D would hold for any of the three parameterisations shown in Fig. 3 and Supplementary Figure 1.

Our observations of unsaturation of ei at moderate to high D are in agreement with recent results from an experiment with angiosperm species Gossypium hirsutum and Eucalyptus pauciflora (Wong, Canny and Farquhar, unpublished). In that experiment, gas exchange was measured independently on upper and lower leaf surfaces, with the lower leaf surface exposed to air with CO2 concentration reduced so that net photosynthetic rate was zero, and the upper leaf surface to air with CO2 concentration near the ambient atmospheric value. Under such conditions, a gradient of ci should have existed from the upper to the lower surface. As D increased above about 2 kPa, the apparent ci gradient reversed, indicating that the calculations of ci were in error; the most parsimonious explanation was unsaturation of ei.

In our experiment, P. edulis showed a stronger tendency toward unsaturation of ei with increasing D than did J. monosperma. The two species are known to differ in their hydraulic behaviour: P. edulis is relatively isohydric, whereas J. monosperma is relatively anisohydric24,25; stem hydraulic conductivity decreases more strongly in response to decreasing soil water potential in P. edulis than in J. monosperma26; and the bulk modulus of elasticity is lower in P. edulis than in J. monosperma leaf tissue25, suggesting mesophyll cell wall function differs between the two species. Our data suggest a coordination in hydraulic behaviour between the stem xylem and the mesophyll cell walls. As the evaporation rate from the mesophyll cell walls increased in response to increasing D, stronger flexure of the menisci in the cell wall pores would have decreased the cross sectional area of pore space, causing an increase in frictional resistance to water movement, and therefore a reduction in mesophyll cell wall hydraulic conductivity27. Our results suggested a steeper decline in mesophyll cell wall hydraulic conductivity in P. edulis than in J. mosoperma as D increased, analogous to steeper declines in xylem hydraulic conductivity with decreasing water availability.

Here we provide the first experimental evidence of unsaturation of ei in conifer trees by applying a novel method to estimate ei under field conditions. There are few previous reports of unsaturation of ei, likely because there is no simple method for directly measuring ei. Recent theoretical treatments differ in their assertions as to the importance of unsaturation of ei for leaf gas exchange28,29. We show here that the potential errors that can occur in the estimation of gs and ci by assuming saturation of ei can be significant. Leaf gas exchange measurements are globally common, and errors associated with assuming saturation of ei could have a major impact on their interpretation. Our method of determining ei has potential for broad application, given recent technological advances in laser-based methods for determining δ18O of CO2 and water vapour30. This could open the door to new insights into how leaves regulate water loss, with fundamental implications for understanding environmental constraints on plant function.

Methods

Our experiment took place at Los Alamos National Laboratory’s SUrvival-MOrtality (SUMO) outdoor experiment (35.8180°N, 106.3053°E, elevation 2180 m). The soil texture at the site is sandy loam at the surface grading to a clay loam with depth31,32. Soil depth ranges from 40 to 80 cm. The site is located in an upland topographic position near the ecotone between piñon-juniper woodland and ponderosa pine forest. Pinus edulis and Juniperus monosperma are the dominant tree species. The 30 year mean annual temperature and precipitation at a meteorological tower located about 1 km from the site are 9.2 °C and 470 mm, respectively. Roughly half of the annual total precipitation falls from July to September during the North American Monsoon.

For this study, we used mature trees of both species, located within and on the periphery of the SUMO experiment. The experiment comprises control, drought and heat treatments designed to mimic historic conditions during mortality-inducing drought in piñon-juniper woodlands33 and during extreme heat waves. The control trees were growing in ambient temperature and precipitation with no experimental manipulation; and the treated trees were exposed to ~50% precipitation reduction by rainfall exclusion and ~5 °C above ambient temperature by open-top chambers34. The rainfall exclusion structure was installed on 1 June 2012 and heat treatments were operational on 11 June 201235.

Our measurements took place from 11–24 September 2012 and from 23–30 August 2013, and included individuals of both J. monosperma and P. edulis. Control trees of both species were measured in both campaigns and drought + heat trees were measured during the 2012 campaign. Ambient conditions were drier during the 2013 campaign and gas exchange rates in drought + heat trees were too low for measurements at that time, so the 2013 campaign included only un-manipulated control trees.

We coupled a Tunable Diode Laser (TDL; TGA100A, Campbell Scientific Inc., Logan, UT, USA) to a portable photosynthesis system (Li-Cor 6400; Li-Cor Biosciences, Lincoln, NE, USA) fitted with a conifer cuvette (Li-Cor 6400-22) to quantify the concentration of CO2 and its isotopic composition (δ13C and δ18O) in gas entering and exiting the leaf chamber. The gas streams were plumbed directly into the TDL using ultra-low porosity tubing (Synflex type 1300 1/4 in diameter; Saint Gobain Performance Plastics, Northboro, MA, USA). The TDL data acquisition and processing were as described previously36.

Calibration of the TDL was maintained by using two working standard (WS) calibration tanks during measurements. These WS tanks were calibrated against World Meteorological Organization (WMO) certified standard tanks. To account for instrument drift, the TDL measured the high and low WS tanks during a 3 min cycle also including measurements of the gas exchange cuvette inlet and outlet gas streams. For each 3 min cycle, we calculated the deviation between the measured values and the known values to determine a gain and offset for each isotopologue37. These gain and offset values were then applied to all data in the 3 min measurement cycle. The measurements of gas entering and exiting the cuvette fell within the range of isotopologue concentrations within the two WS tanks.

Before the gas streams entered the TDL, part of the flow was diverted to a cavity-ring-down spectroscopy water isotope analyser (Picarro L2130-i, Picarro Inc., Santa Clara, CA, USA) that measured the δ18O of water vapour. The pre- and post-cuvette gas streams were measured for 10 min each at approximately 1 Hz, and the final 5 min of measurements was averaged for each gas stream. The water isotope analyser was calibrated with WS waters. These were introduced into the analyser either using the associated vaporizer unit or by sampling air from sealed plastic bags equilibrated with WS water samples enclosed within them. The temperature dependent liquid-vapour equilibrium fractionation factor was applied in the latter case. The WS water vapours were run once per day.

Our sampling regime was designed to loosely mimic the increasing D that a leaf typically experiences from early morning through to the afternoon. For the most part, we measured one foliage sample per day. The terminal part of a J. monosperma or P. edulis twig was placed in the Licor conifer chamber one to two hours after sunrise. The entry point of the twig into the cuvette and all exposed gasket surfaces were covered with flexible putty (Terostat IX, Henkel Technologies, Düsseldorf, Germany) to minimize diffusion leaks. The first measurement generally took place under irradiance of 300 µmol photons m−2 s−1, and at Tl between 15 and 20 °C. The leaves were allowed to stabilise their gas exchange in the cuvette for about 30 min before a measurement began. Thereafter, we recorded gas exchange, δ18O of CO2 and δ18O of water vapour for 20 min. The irradiance and cuvette temperature were then increased, such that a series of measurements was made for each foliage sample from low to high D. The range of Tl in the dataset was from 14.6 to 40.8 °C, and the range of photosynthetically active radiation from 300 to 2200 µmol photons m−2 s−1. Chamber flow rate was varied between 250 and 500 µmol s−1, with the aim of maintaining a [CO2] drawdown in the leaf chamber of at least 15 µmol mol−1. The [CO2] within the chamber was approximately 390 µmol mol−1. The series of measurements for each foliage sample usually continued until gas exchange diminished as a result of high D to such an extent that a 15 µmol mol−1 [CO2] drawdown between chamber inlet and outlet could not be achieved.

All gas exchange and isotopic calculations are described in detail in the Supplementary Material. Segmented regression analysis was performed using SegReg freeware (https://www.waterlog.info/segreg.htm), and all other regression analyses were performed in Systat 12 (Systat Software Inc., San Jose, CA, USA).

Data availability

The datasets generated and analysed during the current study are available from the corresponding author on reasonable request.