Introduction

Batteries play a significant part in powering modern technology, from consumer goods to electric vehicles and renewable energy storage systems1. It is important that the battery is able to safely, reliably, and efficiently provide and accept power and store energy as required. The performance and efficiency of a lithium ion battery is largely governed by the resistance of the electrochemical system. As the cell ages, through storage and cycling, this efficiency becomes progressively worse2. Knowing and understanding cell resistance therefore, is crucial in defining cell performance for different battery states and operating conditions. Internal resistance is also a critical index to define state of health (SoH) for lithium ion batteries3.

Cell resistance also has implications for the performance of the entire battery system. Battery systems in applications such as electric vehicles (EVs) employ a large number of cells connected in series and parallel. Unbalanced systems with differences in cell resistance limit the power delivery capability when connected in series. In parallel arrangements, significant differences in cell resistance result in non-uniform current loads in the pack4 leading to temperature gradients and consequently varying levels of cell degradation1.

In addition to thermal gradients across the battery pack, thermal gradients can also develop across individual cells, both along and normal to the electrode stack, due to inhomogeneous local current distributions under operational conditions, or internal manufacturing defects5. Such inhomogeneity results in localised heating, leading to local cell temperature ‘hot spots’ approaching values close to which the separator can melt leading to thermal runaway6. Internal defects giving rise to such local hot spots are correlated to localised film formation (SEI layer) and consequently localised discrepancies in resistance7.

Measurement techniques have traditionally employed either direct current (DC) or alternating current (AC) loads to calculate DC resistance (large current resistance) or AC resistance (small signal resistance) respectively8,9. In complex electrochemical systems such as a Li-ion battery, electrochemical processes, electrode microstructures and complex transport phenomena all contribute to internal resistance10. Furthermore, the state of the battery, namely: the battery’s state of charge (SoC)11, temperature12 and SoH affects the measured resistance8. Given the performance of Li-ion batteries depends on SoC, temperature and SoH, tests used to derive resistance are designed such that SoC, temperature and SoH remain unchanged13,14,15 during the course of testing. The value of resistance measured will thus depend on the remaining degree of freedom: the measurement duration (timescale) of the measurement, which is related to the underlying electrochemical process involved.

Pulse power tests usually have pulse lengths in the order of 1–30 seconds; at this timescale electron transfer, ion transfer and ion diffusion will contribute to resistance16. AC resistance on the other hand, historically, employed a sinusoidal AC signal of 1 kHz to measure the resistance17. At such large frequencies, depending on the particular battery technology, the cells will either be dominated by inductive or conductive behaviour. Electrochemical impedance spectroscopy (EIS) is a perturbative characterisation technique employing a spectra of perturbation frequencies which reveals the underlying electrochemical process across a wide frequency range18. The signal amplitude used in EIS is relatively very low compared to DC pulses, hence the resistance measured with this technique is sometimes known as the small signal resistance.

Recent work by Omar et al.19 indicates that in addition to SoC and temperature, current amplitude can also affect battery resistance. To account for current dependencies, the pulse power characterisation method uses a series of discharge and charge current pulses of increasing C-rates applied at pre-defined SoC and temperatures. In order to better represent the frequency bandwidth in application, Widanage et al.20 proposed a new signal design technique to generate a pulse-multisine signal, which is more dynamic in amplitude and frequency relative to standard pulse power tests and was shown to better predict battery performance, when subsequently applied to a model of a battery operating using real world duty cycles21.

While it may, naively, be expected that the internal resistance of a battery is the same irrespective of the technique employed, some authors have found that in practice resistance varies with the measurement technique used. Schweiger et al.22 attempted to categorise this in their study based on a 2 Ah cell. They calculated resistance using the pulse power method, EIS technique and Joule heating (thermal loss method). In the latter, heat measured using a calorimeter – under cycling – is entirely attributed to Joule heating; resistance is then calculated by equating the generated heat to i2R. In this technique, reversible entropic heat, side reactions and the heat of mixing2 are ignored which was shown to be important at low SoC16. Furthermore, this technique, which is employed in applications such as thermal management system design23,24, is complex, costly and the subsequent results have large uncertainty. This has restricted its widespread use for estimating internal resistance. More importantly, Schweiger et al. concluded that the AC impedance measured from EIS tests cannot be directly compared to that from pulse power test because of the complex electrochemical nature of the cell, without offering further analysis of the root cause. This may not necessarily be valid; there could be different underlying mechanisms contributing to the discrepancy between these techniques, and this has been investigated as part of this research. In recent work by Waag et al.8, the EIS technique and resistance measurements using a single charge-discharge pulse pair were applied to study changes in internal resistance as a function of SoC, temperature and current over the lifetime of a battery. A comparison of resistance calculated via the two techniques highlighted discrepancies, which the authors attributed to the non-linearity of the electrochemical device based on a theoretical understanding developed for lead-acid batteries25. Besides the work of Schweiger et al.22 and Waag et al.8, many other published works have used more than one technique for measuring resistance. For example, ageing studies2,9,26 have all used more than one technique for measuring resistance rise. Given that battery testing is costly, time consuming and can introduce unwanted ageing, characterisation testing should be minimised to a level where techniques that do not provide unique data are made redundant.

Since the work of Schweiger et al., existing techniques for resistance measurements have been updated and new techniques such as the pulse-multisine method have been proposed. Any up-to-date, rigorous analysis of these methods, therefore, is also of value to the research community. The consistency of the techniques is vital for future ageing studies; given that EIS and pulse current tests are often used together, being able to compare these complementary techniques accurately is important.

The primary objective of the aforementioned studies was not concerned with the techniques used to measure battery resistance and therefore did not consider the differences, or similarities, between the techniques themselves and the physical meaning of the resulting resistance measurements. In this work therefore, a subset of established techniques is presented. The various processes contributing to cell resistance are derived and explained in detail for each technique. Each technique is then applied to 20 Ah LiFePO4/C6 pouch cells and the results are used as a basis of comparison between the different techniques. It is shown that the timescales of the measurement technique govern the resulting resistance estimate. Consequently, it is shown that resistance derived from any technique can be estimated purely from the EIS data. Given that the EIS technique readily attributes timescales to physical processes, it is argued that the EIS technique may be a sufficient test for determining the battery resistance without requiring further tests.

The theoretical background of different methodologies for resistance measurements is outlined in the next section. Afterwards, a test matrix is proposed to measure resistance of cells by employing all of the techniques identified and results are presented along with the discussion. Finally, the overall contributions of this research is summarised.

Theory of measuring resistance employing DC signals

The DC resistance of a battery is simply the ratio of voltage to current, arising from a given current/voltage perturbation (∆V/∆I). An example of voltage drop due to a step-current discharge pulse is shown in Fig. 1. There are a number of phenomena contributing to the voltage drop, governed by their respective timescales: (i) the instantaneous voltage drop is due to the pure Ohmic resistance R0 which comprises all electronic resistances and the bulk electrolyte ionic resistance of the battery16, (ii) the voltage drop within the first few seconds is due to the battery’s double layer capacitance and charge transfer resistance RCT which is attributed to the charge transfer reaction at the electrode/electrolyte interface8, and (iii) the shallow, linear (or close to linear) voltage drop is due to polarisation resistance Rp which accounts for ionic diffusion in the solid phase and is usually considered to be the rate determining step for Li ion batteries27. The contribution of these three parts can be calculated separately for an intuitive understanding of the complex electrochemical processes involved in the battery system. On the other hand, a bulk total cell resistance can be calculated from the total voltage drop for the pulse, as is often done in the literature15,28. The other drawback of using DC current to obtain resistances is that only the imposition of all the different contributions to resistance, hence there in an inability to completely separate the different resistance components.

Figure 1
figure 1

Cell voltage response to a pulse current.

Internal cell resistance calculated from multiple discharge/charge pulses of different amplitudes is also common in literature and standards13,29. In this case, current pulses of different pre-defined amplitudes give rise to analogous voltage responses; resistance is then defined as the gradient of the voltage versus current plot. As long as the change in SoC is negligible and the battery does not enter into a regime of diffusion limitation28, the voltage response will remain linear. Furthermore, depending on how long into the pulse the voltage is measured, the gradient will represent a phenomenon between the pure Ohmic resistance (milliseconds) and the cell’s bulk total resistance (seconds). Therefore, as long as the current amplitude is not very high or very low (the definition of which is cell dependent), the resistance calculated using this method is expected to be similar to that calculated using a single pulse.

The pure Ohmic resistance R0 can be calculated from the falling edge of a voltage response pulse, from the instantaneous voltage drop when current stops. The value of R0can also be calculated from switching current, by measuring instantaneous voltage change due to any current change. In principle, the R0 value calculated with these methods should be equal to that calculated from the rising edge of the pulse. However, due to the preceding current load, in the falling edge scenario, the electrode surface of the cell is highly polarised30. When the current load is switched-off, the system equilibrates and the non-intercalated cations in the double-layer diffuse back into the electrolyte bulk. The difference in Li-ion concentration at the electrode/electrolyte interface between the rising and falling edge of a pulse, results in a small voltage differences and consequently R0.

Theory of measuring resistance employing AC signal

Measuring battery resistance with a 1 kHz AC signal (or similar single frequency signal), is common practice in industry, especially for measuring lead-acid battery resistance. It is a relatively fast (in the order of seconds), low power consuming and low cost technique, using handheld equipment. Usually a low current sinusoidal signal of 1 kHz is applied to the battery and the voltage response is measured. Although this technique is time-efficient, a single value of resistance is not sufficient to characterise the battery’s performance. This is because charge transfer through multilayer surface films and kinetic and diffusional processes in the solid and liquid phases of the battery lead to a frequency dependent resistance. In equivalent circuit models, this frequency dependence is analogically represented by multiple resistance elements coupled with surface layer capacitances12,31. Therefore, a complete characterisation of battery resistance requires measurements spanning low (<1 Hz) to high (>100 kHz) frequencies.

Electrical impedance spectroscopy (EIS) employs multiple frequency sine waves to measure resistance over a wide range of frequencies. For EIS measurements, a frequency range of 100 kHz to 10 mHz is common in the literature8,12,18. The detailed theory of EIS has previously been discussed in the open literature8,32. In essence, a current/voltage signal (galvanostatic/potentiostatic) is applied and the voltage/current response is measured. From the voltage/current response, resistance is calculated.

Consider the galvanostatic excitation signal i(t)

$$i(t)={i}_{o}sin(\omega t+{\phi }_{1})$$
(1)

where i o is the excitation magnitude, ω is the excitation frequency, t is time and φ 1 is a phase angle. The resulting voltage response v(t) will have the same frequency, but different phase angle φ 2:

$$v(t)={v}_{o}sin(\omega t+{\phi }_{2})$$
(2)

where v o is the voltage amplitude. Eqs (3) and (4) is a simple mapping from time domain to phasor domain for a sinusoidal variable.

$$I(\omega )={I}_{o}(\omega ){e}^{j{\phi }_{1}(\omega )}$$
(3)
$$V(\omega )={V}_{o}(\omega ){e}^{j{\phi }_{2}(\omega )}$$
(4)

where j is the imaginary unit. The complex resistance as a function of frequency is then given by:

$$Z(\omega )=\frac{V(\omega )}{I(\omega )}\frac{{V}_{o}{e}^{j{\phi }_{2}}}{{I}_{o}{e}^{j{\phi }_{1}}}={Z}_{0}{e}^{j({\phi }_{2}-{\phi }_{1})}.$$
(5)

The Euler representation is

$$Z(\omega )={Z}_{o}({\cos }(\phi )+i\cdot \,{\sin }(\phi ))$$
(6)

where, φ = φ 2 − φ 1. The complex resistance Z(ω) has two parts: real and imaginary, which is commonly illustrated by a Nyquist plot. An example of an EIS Nyquist plot is shown in Fig. 2.

Figure 2
figure 2

Typical Nyquist plot of a new li-ion battery cell (a), and an mth order ECM (b). The series resistor R0 denotes the internal resistance and the m RC pairs denote the dynamic model parameters.

In the Nyquist plot, negative values of −Im(Z(w)) indicate inductive dominated behaviour (high frequency) while positive values of −Im(Z(w)) indicate capacitive dominated behaviour (mid-low frequency). At the point where Im(Z(ω)) = 0 both capacitive and inductive behaviours are balanced; this point is typically correlated with the pure Ohmic resistance R0 8. Towards the low frequency region of the Nyquist plot, the local minimum of −Im(Z(ω)) can be found as indicated in Fig. 2(a). The difference between the Re(Z(ω)) at \({\rm{\min }}\{-{\rm{Im}}({\rm{Z}}({\rm{\omega }}))\}\,\,\)and R0 corresponds to the charge transfer resistance RCT. The real part of Z(ω) at \({\rm{\min }}\{-{\rm{Im}}({\rm{Z}}({\rm{\omega }}))\},\,\,\)in theory therefore, should correspond to the total resistance measured from other methods e.g. pulse power test.

Depending on cell type and experimental setup (e.g. cable assembly), the 1 kHz resistance measurement can be in the inductive or conductive region. Typically, for cells with large capacities (e.g. a 40 Ah pouch cell) the resistance at 1 kHz is dominated by inductive behaviour. On the other hand, cells with relatively lower capacities (e.g. a 3Ah 18650 cell) can have a 1 kHz resistance close to the point where Im(Z(ω)) = 0 29, and thus give reliable and repeatable measurements.

Theory of measuring resistance employing pulse-multisine signals

The pulse-multisine procedure20 is a method designed to better represent the frequency bandwidth of the current load in application than a pulse power test. It involves three steps in estimating the internal resistance of a battery. The first step is the design of a pulse-multisine signal, followed by estimating the resistance of the battery as a function of frequency and the third step is fitting an equivalent circuit model (ECM) to the resistance estimate from which the internal resistance is obtained.

A pulse-multisine signal is set up to span the full applicable maximum 10 seconds charge and discharge C-rates that a battery can support at a given temperature and SoC, while exciting the battery over a frequency range representing the realistic usage case. The designed pulse-multisine is then applied to the battery to estimate its resistance response as a function of frequency and subsequently the internal resistance.

The resistance Z(ω) at a given angular frequency ω is related to the complex current and voltage signal as

$$V(\omega )=Z(\omega )I(\omega )+E(\omega )$$
(7)

where E(ω) is the complex error that can arise due to any measurement error or nonlinear response of the battery. To estimate the resistance Z(ω)in Equation (7) given I(ω)and V(ω)requires minimising the complex error in a least squares sense. A method known as the Local Polynomial Method21 is used to estimate the resistance \(\hat{{\bf{Z}}}({{\boldsymbol{\omega }}}_{{\bf{k}}})\) along with its standard deviation \({{\boldsymbol{\sigma }}}_{\hat{{\bf{Z}}}}({{\boldsymbol{\omega }}}_{{\bf{k}}})\).

Once the non-parametric resistance (\(\hat{{\bf{Z}}}({{\boldsymbol{\omega }}}_{{\bf{k}}})\)) is estimated, an ECM model is fitted to it to obtain the internal resistance along with other dynamical parameters. A general mth order ECM is shown in Fig. 2(b). The internal resistance of interest is denoted by the series resistance R0 while the remaining RC parameters denote the polarisation dynamics and the open circuit voltage U.

The resistance of this general mth order ECM is given in Equation (8).

$${Z}_{m}(\omega )={R}_{0}+\sum _{i=1}^{m}\frac{{R}_{i}}{j\omega {\tau }_{i}+1}$$
(8)

The first term R 0 is the pure resistive resistance and the remaining m-terms correspond to the resistance of the m RC pairs with the product R i C i denoting the time constant τ i of the i th RC pair.

To estimate the parameters R 0, R i and τ, the model order m should be decided in advance. The estimated impedance response can support the choice of the model order21, however, in the absence of resistance response, typical model orders are first or second order27,33. In this manuscript, a second order model is considered to estimate the parameters as this has been shown to capture cell behaviour most accurately21.

Experimental Method

In this work, commercially available 20 Ah pouch cells with a graphite (LiC6) negative electrode and lithium iron phosphate (LiFePO4) positive electrode are used. The maximum charge voltage for the cells is 3.6 V (3.8 V for 10 sec pulse current) and minimum discharge voltage is 2.0 V (1.6 V for 10 sec pulse current). The manufacturer defined maximum charge and discharge capability are 15 C instantaneous. All the tests as outlined below were performed on each cell.

At the beginning of testing, the SoC for each of the cells was adjusted to 50% at 25 °C, using a commercial cell cycler (Bitrode MCV 16-100-5) and an environmental chamber (Weiss Gallenkamp Votsch VC3 4060). The adjustment protocol includes discharging the cells to the manufacturer defined minimum discharge voltage (defined as 0% SoC), which is followed by a 4 hour rest period. Subsequently the cells are charged using a constant current – constant voltage protocol (CC-CV) using the 1 C current rate for the CC part until 3.6 V is reached and then holding the cells at 3.6 V for the CV part, until the current falls below the C/20 cut-off current. After a 4 hour rest period, the cells discharged at the 1 C rate for 30 min to adjust to 50% SoC. Another 4 hour rest period was applied, allowing the cells to reach electrochemical equilibrium18. The five internal resistance estimation methods were then applied to characterise the resistance at 50% SoC at 25 °C.

The pulse power test with a single discharge/charge pulse was applied at 5 C current for 18 seconds and the cells rested for an hour prior to charging at 5 C for 18 seconds. The pulse duration of 18 seconds was chosen because it is one of the longest pulse durations outlined in current standards14.

The next test performed on the cells was the pulse power test with multiple pulses as suggested in ref.13. In this test, cells were charged and discharged with 10 second pulses at 1 C, 2 C, 5 C and maximum C, with intermediate 30-minute rest steps after each pulse. The individual pulses can be used to calculate resistance as per the methodology described in Section 2.1.

In the switching current methodology the current is step changed (here 1 C to 5 C are used as suitable low and medium current amplitudes) and the voltage change due to this current step change is measured; internal resistance is then calculated via Ohm’s law22. The current can be changed during discharge, charge or from discharge to charge. For the latter, the current is switched, in this work, from 5 C discharge to 5 C charge (both with 5 second pulses). In the discharge only case, the current is switched from −1C to −5C during discharge, and finally in the charge only case, the current is switched from 1 C to 5 C during charge. Here, 1 C and 5 C current values are used as representative only.

Following resistance measurements using DC current pulses, resistance was measured with AC current signals. The 1 kHz resistance was measured with a Hioki BT3563 1 kHz resistance tester at 50% SoC, 25 °C.

Galvanostatic EIS tests were performed using a Solartron Modulab system (model 2100 A) fitted with a 2 A booster card. Multiple EIS measurements were taken on the same cell under the same test conditions within the frequency range of 10 mHz to 100 kHz, using different RMS current values: 0.2 A, 0.5 A, 0.8 A, 1.0 A and 1.4 A. These current values were selected such that they were not too high to change the cell’s SoC during measurement but high enough for a good signal to noise ratio for the response voltage signal. This was to analyse the EIS dependency on the amplitude of the signal current.

With the pulse-multisine signal procedure, five periods of the signal were applied, with the battery adjusted to 50% SoC and allowed to equilibrate, and the corresponding voltage response recorded. Once the data was collected, the non-parametric resistance and ECM were fitted as described in previous Section.

Results of the experiments employing DC signals

Pulse power test results with a single 5 C discharge and charge pulse of 18 sec are shown in Fig. 3. Using this pulse, the DC resistance can be calculated for any length of pulse up to 18 seconds. The pure Ohmic resistance was calculated from the voltage drop after 0.1 sec of the pulse current. Ideally, the pure Ohmic resistance should be calculated from the instantaneous drop of voltage due to change in current. However, measurement of the instantaneous drop is limited by the data acquisition rate of the equipment used. For this experiment, the battery cycler that was used has a maximum resolution of 0.1 sec.

Figure 3
figure 3

Voltage response to 18 second (a) discharge pulse and (b) charge pulse. Resistance calculated for pulse duration are shown in (c) for discharge and (d) for charge. In subplots (c) and (d), (i), (ii) and (iii) refer to pure Ohmic resistance R0, charge transfer resistance RCT and polarization resistance Rp, respectively. The overlap between (ii) and (iii) is indicative of the inability, within this technique, of precisely discerning each contribution.

Since the electrodes are thin (as it is a high power cell) and the electron pathways for charging and discharging are similar in the cells used, the pure Ohmic resistances (resistance calculated at 0.1 sec after the onset of the pulse) are comparable as shown in Table 1. The longer-time resistance for charge and discharge however, are different as illustrated in Fig. 3(c,d), and Table 1. During charge, the positive electrode material is oxidised, Li ions are de-intercalated from the layered lithium intercalation host, in this case LiFePO4, pass across the electrolyte and are intercalated between the graphite layers by an electrochemical reduction reaction proceeding at the negative electrode. On the other hand, during discharge, an oxidation reaction occurs at the negative electrode, Li ions are de-intercalated from the anode, and migrate across the electrolyte to be re-intercalated into the positive electrode material, where a simultaneous electrochemical reduction reaction proceeds. In general, the higher the electrode potential, the harder it is to remove a lithium from a site within the host matrix. On discharging a cell, Lithium is transferred from a high energy state in the anode to a low energy configuration in the cathode, hence, the resistance values for discharging are higher than that of charging at 50% SoC; this has also been found by other researchers8,22.

Table 1 Change of internal resistance with pulse duration.

The resistance in Fig. 3(c) and (d) can be categorised into three parts associated with the processes contributing to the voltage drop discussed in Sec. 2.1., namely: (i) pure Ohmic resistance R0 resulting in the instantaneous voltage drop and is dominant up to 0.1 seconds, (ii) the charge transfer resistance RCT occurring from circa. instantaneous up to 2–5 seconds and (iii) the slow, linear, solid phase lithium ion diffusion which inevitably results in concentration polarization Rp, especially during high current charging, which takes the battery voltage rapidly up to the upper voltage limit, occurring at timescales 5 seconds34. Although Ro, RCT and Rp are not completely separated, at their respective timescales they are expected to be the dominant contribution to the total resistance.

The internal resistance calculated from five charge-discharge pulses of varying amplitudes is shown in Table 2. The 5 C test data is the same data as that shown in Table 1. The pure Ohmic resistance (calculated from the 0.1 sec voltage drop) remains similar for all pulse amplitudes, with a standard deviation of 0.05 mΩ. However, the difference in resistance value that was calculated at the end of 2 seconds, 5 seconds and 10 seconds varies with charge-discharge rates. For example, the difference between resistance measured with a 2 second and 10 sec pulse is 0.73 mΩ using a 1 C discharge pulse, while it is 0.39 mΩ using a 15 C discharge pulse. The discrepancies in the rate of resistance rise arising due to pulse amplitudes are attributed to the various electrochemical processes that are activated within the cells as the duration of the pulse is extended and the heat generation associated with pulse currents. For higher current pulses, such electrochemical processes are activated earlier (as the double layer can be discharged much quicker) – the large magnitude current values also cause the ratio V/I to be suppressed8. In addition, at higher rates, more heat is generated i.e. 0.5 Wh (1800 Joules) in just 10 seconds when 300 A (15 C) current is passed through a 2mΩ resistance, which effectively increases the internal temperature of the battery which contributes to the resistance decrease as seen in Table 2.

Table 2 Internal resistance (mΩ) calculated from different amplitude discharge pulses.

For long duration pulses at higher rates, it is anticipated that changes in resistance will be dominated by changes in SoC. At the 1 C pulse rate, after 10 seconds, the SoC changes by an insignificant 0.28%; at the 15 C pulse rate, after 10 seconds, the SoC changes by 4.2% - which can lead to an appreciable voltage drop/rise. For the LiFePO4 battery the voltage plateau between 70% and 40% SoC35, where measurements for this work were taken, means that a 4.2% change in SoC has little impact. For battery technologies with steeper OCV curves, such as LiNiCoAlO2 and LiNiMnCoO2 however, the effect is expected to be more pronounced.

The results of Table 2 show distinctive peaks for resistance at 2 C for discharging and 1 C for charging for this method. Within the Butler-Volmer framework, these peaks may be associated with the temperature-overpotential duality.

Pure Ohmic resistance was also calculated from the falling/rising (charge/discharge) edge, at the end of a pulse. The pure Ohmic resistance calculated from 1 C, 2 C, 5 C and 15 C discharge pulses are 1.30 mΩ, 1.35 mΩ, 1.35 mΩ and 1.40 mΩ respectively and for 1 C, 2 C, 5 C and 15 C charge pulses are 1.40 mΩ, 1.40 mΩ, 1.40 mΩ and 1.56 mΩ respectively. On average, the values for discharge are less than 0.1 mΩ higher than those shown in Table 2. This may be related to the energy required for de-intercalation from the positive electrode and intercalation into the negative electrode being different from de-intercalation from the negative electrode and intercalation into the positive electrode.

The voltage responses to the change of current from discharge to charge and current magnitudes during charge and discharge are shown in Fig. 4(a,b and c), respectively, Fig. 4(d) presents the pure Ohmic resistance calculated from the switching edge of a pulse current. The resistance calculated from changing the discharge current from 1 C to 5 C is similar to that calculated from the 0.1 second pulse and the falling edge method. In the charging scenario, current is switched from 1 C to 5 C, the resistance closely matches that calculated using the pulse power method. The resistance calculated by switching from discharge to charge closely matches the pure Ohmic resistance for charge current shown in Table 1 and Table 2.

Figure 4
figure 4

Voltage response to switching current from (a) 5 C discharge to 5 C charge, (b) 1 C discharge to 5 C discharge, (c) 1 C charge to 5 C charge, and (d) pure Ohmic resistance calculated from switching edge.

Results of the experiments employing AC signal

The 1 kHz resistance measured using the Hioki 1 kHz resistance tester was 0.82 mΩ. The 1 kHz resistance, for these cells, lies in the inductive dominated region as can be seen in the EIS Nyquist plot in Fig. 5.

Figure 5
figure 5

EIS results from 100 kHz to 10 mHz with different signal amplitudes (a) Nyquist plot and (b) Bode plot of same data. Inset (a) a zoomed view of the central part is shown.

The EIS test results with different current amplitudes are presented in the form of a Nyquist plot in Fig. 5(a). There are no identifiable differences between results due to changing the amplitude of the galvanostatic signal, as expected. The zoomed view shown in the inset, shows slightly noisy results for 0.2 A which is supressed for 0.5 A and beyond. Therefore, resistance measured using EIS is not dependent on current amplitude, but using higher currents can reduce noise. Indeed, if a higher current like 1 C was used for the EIS test, it would have an effect on results, however application of such high current for EIS test has a little precedent in literature. A current amplitude of C/20 (in this case 1 A) can produce the same results repeatedly with low measurement noise, limited by the equipment sensitivity. The EIS results for the 1 A magnitude is presented as a Bode plot in Fig. 5(b).

From inspection of the Nyquist plot, the pure Ohmic resistance Ro, was found to be 0.92 mΩ corresponding to 251 Hz (i.e., a timescale of 4ms). The resistance at the local minimum before the cells enters into the low frequency diffusion dominated region was found to be 1.55 mΩ, corresponding to 2 Hz; and thus RCT is 0.63 mΩ. Estimating polarisation resistance using EIS results is not well-defined. Given that Rpvalues for the DC pulse in this discussion was derived from a 10 second pulse, the 0.1 Hz result is used to define Rp. The equivalent resistance at 0.1 Hz from EIS results corresponds to 0.36 mΩ; this becomes 1.39 mΩ when a frequency of 0.01 Hz is considered to calculate the Rp value.

Results of the experiments employing a Multisine signal

The phase and magnitude of the estimated resistance, based on the local polynomial method (LPM), and a 2nd order ECM model fit are shown in Fig. 6. Although the ECM parameters are not uniquely identifiable, the series connected resistance and the resistance of the 1st and 2nd RC branches of the ECM are typically attributed to Ro, RCT and Rp which were found to be 1.618 ± 0.003 mΩ, 1.10 ± 0.07 mΩ and 0.109 ± 0.005 mΩ, respectively. The value of Ro is significantly higher than that of found with other techniques. This can be related to two potential reasons: i) the fact that most of the power in the driving current signal belongs to harmonics lower than 1 Hz, and/or ii) despite the good fit between model and experimental data, the parameters do not reflect the physical meanings attributed to them (due to unique identifiability).

Figure 6
figure 6

(a) Magnitude and (b) phase response of the estimated resistance via the LPM using a pulse-multisine signal and a fitted 2nd order ECM model.

A comparison of the various resistance measurement techniques

The average pure Ohmic resistance values calculated using different pulse power techniques is 1.33 mΩ with standard deviation of 0.04 mΩ. All these measurements were taken 0.1 sec after the current pulse was applied. Irrespective of charge or discharge, the pure Ohmic resistance values measured by different DC techniques closely match, with a 3% variation, regardless of whether they were measured from the beginning, end or switching point of the pulse current.

A comparison of Ro, RCT and Rp estimated using the techniques discussed above are presented in Fig. 7 (a). The sources of discrepancies between resistance values measured using charge and discharge pulses were discussed previously. The RCT and Rp values are calculated using the 2 sec and 10 sec data points of the pulses.

Figure 7
figure 7

(a) Comparison of resistance values measured by different techniques. (b) Total resistance vs timescale plot showing resistance values agree when timescales match, irrespective to the measurement technique employed.

The R0 value of 0.92 mΩ identified from EIS tests (Fig. 5) corresponds to the 251 Hz (4mS) frequency response; likewise, the RCT value of 0.63 mΩ corresponds to the 2 Hz response. Unlike R0 and RCT the polarisation resistance Rp isn’t identified from a Nyquist plot, instead it is pre-defined. In this study two frequencies were considered, 0.1 Hz and 0.01 Hz which gives values of 0.36 mΩ and 1.39 mΩ, respectively. Since the values of resistance Ro, RCT and Rp have physical meaning36, it is appropriate to define the timescales of Ro, RCT and Rp using EIS results.

Resistance measured using a 1 kHz signal lies in the inductive region of the Nyquist plot, see Fig. 5(a), which is close to the crossover point of the horizontal-axis. Therefore, it is reasonable that the 1 kHz resistance (0.82 mΩ) close to the Ohmic resistance identified from EIS test results (0.92 mΩ at 251 Hz, 0.79 mΩ at 1 kHz). It is worth reiterating that this may not be true for other batteries and the 1 kHz point can be well into the capacitive region e.g., for smaller pouch and cylindrical cells. This is particularly likely for smaller capacity cells, in which case the value will not solely represent the pure Ohmic resistance.

The average pure Ohmic resistance R0 found using DC methods of 1.315 mΩ, is much higher than that found using EIS. In pulse power tests, R0 is typically calculated using the 0.1 sec data point – i.e., it is governed by the lowest resolution of commercial battery cyclers today which is 10 Hz –whereas by definition it should be the instantaneous drop of voltage at the onset of current. Therefore, the DC resistance calculated from pulse power tests will contain kinetic contributions (a portion of RCT), pulling up/down the voltage response beyond the pure Ohmic contribution occurring at timescales of less than milliseconds. Since EIS results of this battery suggests that R0 corresponds to the 251 Hz (4mS) frequency response; it is therefore physically more meaningful to use the voltage drop after 4ms from the onset of a current pulse to determine R0. Although a square wave will excite frequencies beyond the 10 Hz frequency, a 0.1 sec pulse will have the highest harmonic contribution from the 10 Hz sine wave, the extracted values for R0 from DC pulse power tests and EIS tests therefore, will be less divergent. Given the limitation of existing commercial battery cyclers however, this is not feasible and can only be achieved when battery test equipment capable of reaching high pulse currents (from 0 Amp) within 4ms are available. By way of comparison, from Fig. 5(b), the resistance value at 10 Hz using the EIS technique was found to be 1.41 mΩ, which is comparable to the 1.33 mΩ estimated via DC pulse. Hence, the discrepancy in pure Ohmic resistance measured by the DC method can be attributed to limitations of the battery test equipment typically used.

Given that Ro measured by DC pulse will contain charge-transfer contributions, comparing RCT values measured via EIS and pulse current techniques will have foreseeable differences. Similarly, RCT measured using DC techniques will contain polarisation effects which are difficult to isolate. Nevertheless, here, we follow the usual prescription of calculating Ro, RCT and Rp with DC methods8. Using the 5 C pulse, considering 2 sec pulse duration, RCT is estimated to be 0.41 mΩ and 0.38 mΩ for discharge and charge respectively. Due to the fact that a portion of RCT is embedded into Ro (measured from 0.1 sec pulse duration), a comparison of RCT values measured from pulse power test and EIS test in not meaningful. However, the Ro + RCT value, measured after 2 sec pulse duration should be in close agreement with the resistance value deduced from a 0.5 Hz sine wave (as a 2 sec square wave has highest harmonic contribution from 0.5 Hz). From Fig. 5(b), the resistance value measured by EIS at 0.5 Hz is 1.69 mΩ, whereas the Ro + RCT value measured from 2 sec pulse duration is 1.71 ± 0.01 mΩ, which are in close agreement.

Similarly, using a 5 C pulse, considering a 10 sec pulse duration, Rp values are estimated to be 0.40 mΩ and 0.30 mΩ for discharge and charge pulses respectively. Similarly to the case of RCT, Rp values from 10 sec pulse duration cannot be compared with EIS test result. However, the sum Ro + RCT + Rp is expected to be in agreement with the value measured by 0.1 Hz EIS signal. The sum of resistances Ro + RCT + Rp, i.e., the total resistance, from 10 sec pulse duration is 2.12 mΩ and 2.00 mΩ for discharge and charge respectively. The 0.1 Hz EIS result gives 1.91 mΩ (Fig. 5(b)). While these values are close (Fig. 7b), it is expected that the values from discharge pulse and charge pulse of longer than 5 sec will be higher compared to EIS because of the additional intercalation and de-intercalation above that associated with a pure DC load29. Charge transfer dynamics are relatively slower for an AC waveform because of the changing magnitude of current and signs. Furthermore, non-DC waveforms have been shown to circumvent lithium saturation at the electrode-electrolyte interface, thereby lowering the inhibition of ion transport attributed to polarisation and thus Rp 37. Therefore, the sum of Ro + RCT + Rp from a 10 sec pulse duration is expected to be slightly higher than EIS results, as found in this study. In summary, it is suggested that the total resistance calculated from pulse power tests can be estimated directly from EIS test results.

The Ro value (1.62 mΩ) measured by the multisine signal test is much higher than that calculated by DC pulse and EIS methods. The maximum frequency applied in this technique was 1 Hz (Fig. 6). Inspection of the Bode plot shown in Fig. 5(b), indicates that at 1 Hz the cell has a resistance of 1.62 mΩ, which is exactly the value found in multisine signal test employing 1 Hz maximum frequency (Fig. 7b). In addition to the EIS test data, when the 1 second data point from a pulse duration is considered for a DC pulse, the resistance is found to be 1.61 mΩ for both charge and discharge (Fig. 7b). Therefore, the resistance Ro (which is a component in the 2nd order ECM model), estimated by the multisine signal, employs a maximum frequency of 1 Hz, and thus cannot be labelled as a pure Ohmic resistance. Nevertheless, the resistance Ro estimated by the multisine technique exactly matches the resistance identified at 1 Hz from EIS. The total resistance (i.e., sum of Ro + RCT + Rp) for a multisine signal with 0.01 Hz minimum frequency is 2.83 mΩ, which is close to the resistance given by EIS at 0.01 Hz (Fig. 7b).

In conclusion, the results and subsequent analyses show that the resistance values measured by any technique are governed by the measurement timescale. As such, resistance measured by any technique can be estimated from the EIS test data, given its wide frequency content. Resistance values of any frequency corresponding to expected cell kinetics can therefore be obtained.

Impact on application use

Battery resistance is used for different purposes, which include, for example, generating ECM parameter values, modelling and design of thermal management systems, ageing characterisation tests, SoH indication and more. It is an interesting open question as to which technique and value should be used for a particular application. ECMs, for example, are a well-established method of modelling the behaviour of Li-ion batteries. The model is reliant on resistance and resistances coupled with surface layer capacitance terms. Traditionally, pulse power data is used to determine the parameters of ECMs by fitting the model to the data and requiring that errors be minimised. The principal motivation for using pulse currents, in addition to the simplicity of the test method itself, is that high current pulses are assumed to mimic battery usage in real application scenarios. An inherent problem with parameter identification is the uniqueness of the solution, which gives rise to ambiguities between identified model parameters (in the simplest case Ro and RCT) and their actual physical values. This ambiguity is further enhanced when higher order equivalent circuit models utilized, which employ more RC circuits in order to describe more detailed physics such as the SEI or double layer (the latter often through constant phase elements). Given this ambiguity, the effectiveness of phenomenological models is judged solely on closeness of fit. Recently, it has been shown the pulse-multisine signals better represent actual battery usage and have a better fit to data21. In that regard, the pulse-multisine method can be a more effective way of defining resistance for systems modelling applications.

The 1 kHz resistance test, although is useful for a quick check in a manufacturing environment e.g. quality check, not much value is derived from it. Furthermore, whether the measured 1 kHz resistance value lies in the inductive or conductive region is highly dependent on the battery sample, therefore the single frequency (e.g. 1 kHz) needs to be chosen depending on the sample when employed for quality check.

In characterising batteries or characterising long term degradation, EIS may be a more appropriate method. This is because the method spans a large frequency range comprising various dynamics in the battery. So in addition to measuring internal resistance rise, conclusions can be derived for the contribution of SEI to degradation and other underlying mechanisms29. While EIS is a well-established technique8, the test duration for producing repeatable results18, the stringent requirements on the sensitive connections and other setup complexities, renders it cumbersome. However, as the evidence provided in this manuscript suggests, the resistance calculated from pulse current, multisine signal and 1 kHz impedance test can all be estimated from EIS test results to a good degree of accuracy; it may be advantageous therefore, to perform a reliable EIS test only.

Conclusions

In this research, five different battery resistance measurement techniques were employed to measure resistance of a LiFePO4/C6 20 Ah pouch cells. From comparison of the results, for the first time it has been shown that it is not the non-linearity of the lithium-ion battery, as suggested in other studies, rather the timescale associated with the technique itself that influences measured internal resistance. If the timescales at which the measurements are taken can be reconciled, the resulting values of resistance are comparable across the techniques. Furthermore, the discrepancy in measuring pure Ohmic resistance with different techniques originates from the limitation of the test equipment, where instead of the instantaneous voltage drop, a voltage drop in the timescale of charge-transfer was recorded. This is because a typical battery cycler has an upper limit of 10 Hz for measurement resolution.

For the first time, it is demonstrated that the resistance measured with different techniques can be estimated from an EIS test result. The root causes of discrepancies between the different methods as reported previously were identified and discussed. It is not possible to categorise a single best or correct technique; this will usually depend on the application and the availability of the test equipment, however, EIS can accurately provide separation and identification of all the individual resistance components, Ro, RCT and Rp. In this manuscript, an in-depth analysis of the techniques was presented, this can assist researchers in deciding which techniques to use based on their application.