Introduction

Bisphenol a (BPA) is an organic synthetic compound that is used in industry to make plastics and epoxy resins for consumer goods and industrial applications. There is established concern that exposure can lead to a variety of health problems in humans1,2,3. Studies have shown that BPA can leach from containers or container linings then migrate into the food or beverages and be ingested4,5 Exposure to BPA (which is known to mimic estrogen), may cause reproduction dysfunction and lead to birth defects in children, breast cancer, recurrent miscarriages, and other ailments6,7. The human health hazards related to BPA continue to be investigated, and thus ultra-sensitive methods for detection of low levels of BPA in common household products and foods are of great interest. At present there are several analytical methods used to detect BPA levels in the environment, including high-performance liquid chromatography (HPLC), gas chromatography coupled with mass spectrometry (GC-MS), enzyme-linked immune sorbent assay (ELISA), molecule imprinting techniques, and electrochemical sensors3,8,9. In addition, a direct (label-free) immunosensor is becoming popular because it reduces sample preparation time and simplifies the sensing protocol10,11.

Surface-enhanced Raman scattering (SERS) is widely used for increasing the Raman scattering signal of molecules adsorbed on rough noble metal, or metal particle decorated substrates12. Recently, new types of SERS-active hybrid materials have been reported, such as graphene layers (graphitic sheets), with deposited metal nanoparticles, which can further enhance Raman signal detection13,14,15,16. Graphene is attractive because it can be produced with a large surface area, good thermal conductivity, high electrical conductivity, and high electron transfer rate17,18,19. Because of these properties, graphene-based Raman scattering is regarded as a versatile characterization tool with ultra-sensitivity for SERS detection20,21. BPA, exhibits only a very weak affinity for adsorption on metal surfaces, thus making BPA detection by traditional SERS methods ineffective. Moreover, the complex constituent mixture in “real” samples can interfere with the Raman scattering signal, resulting in poor detection specificity. Thus, research continues with efforts to identify appropriate SERS substrates that have a strong affinity for BPA.

Here we report on the preparation and evaluation of SERS-active (metal-free) graphitic sheet substrates for ultra-sensitive detection of BPA by SERS methods. The graphitic sheets were prepared using silane-based self-assembled monolayers (SAMs) and then characterized using transmission electron microscopy (TEM, HRTEM), energy dispersive X-ray spectroscopy (EDS), and atomic force microscopy (AFM). Surface-enhanced Raman spectroscopy was the core analytical technique used to detect BPA on the graphitic sheet substrates. We believe that this method will allow ultra-sensitive determination of BPA in a wide variety of samples for clinical, industrial, and consumer product research applications.

Results

Surface characterization of graphitic sheets

TEM and HRTEM images in Fig. 1a show that the graphitic sheets had a lattice spacing of 0.24 nm, which is comparable to the lattice constant of graphene22. To examine the chemical composition of the graphitic sheets, the EDS spectrum was acquired as shown in Fig. 1b. The primary component of the graphitic sheets was carbon, with a minority contribution from oxygen (~12%) which may be due to oxygen atoms at structural defects23. The Cu peaks in the spectra originate from the TEM grid (Fig. 1b inset).

Figure 1
figure 1

(a) TEM and HRTEM (inset) images of graphitic sheet. (b) EDS spectrum showing the chemical composition of graphitic sheets (inset shows EDS spectrum of the grid only). (c) Surface topography AFM images (2 × 2 μm2) and (d) line section analysis obtained from graphitic sheet on a silicon substrate.

The topographic AFM image and corresponding line scan in Fig. 1c and d show a typical graphitic sheet on a silicon substrate (>1 μm lateral extent). Line scan analysis reveals that the height of the graphitic sheet on silicon is ~0.34 nm, which is comparable to the interlayer spacing of graphene24. Thus, the graphitic sheets fabricated in our study exhibit structural characteristics that are nearly identical to those of graphene.

Determination of feasibility and detection limit

The range of products which may contain BPA is broad, thus the capability to detect and monitor BPA in various mixtures is important. We first investigated Raman spectra of a clean silicon substrate and graphitic sheets on silicon, and the SERS spectra of 10−1 M BPA deposited onto both substrates separately (Fig. 2a). The inset in the figure shows vials of pure water (left) and of the stock graphitic sheet solution (right) illuminated using a 532 nm laser. Both vials are optically clear but laser light is scattered in the stock solution. Optical scattering and the Raman result shown in (Fig. 2a – GS), confirm that the stock solution contained graphitic sheets.

Figure 2
figure 2

(a) Raman spectra of 10−1 M BPA deposited on a graphitic sheet substrate and on a bare silicon substrate, respectively. The bottom curves are normal Raman spectra of the same substrates without BPA. The inset shows light scattering images of pure water (left) and graphitic sheet solution (right) using a 532 nm laser. (b) Concentration-dependent SERS spectra of BPA on graphitic sheets adsorbed on a silicon substrate showing a dilution series from 10−1 to 10−6 M.

No peaks were observed in Raman spectra from a clean silicon substrate. However, Raman spectra from graphitic sheets on silicon had two prominent peaks at 1341 cm−1 and 1602 cm−1 which are assigned to the D and G bands, respectively. The D band is associated with a breathing mode of the sp2 carbon rings and is active when the ring is adjacent to defects, and the G band corresponds to optical E2g phonons25. The SERS spectra of 10−1 M BPA on both substrates in Fig. 2a exhibited characteristic peaks at 1121 cm−1, 1188 cm−1, 1240 cm−1, 1269 cm−1, 1621 cm−1, and 3072 cm−1. The peaks at 1121 and 1188 cm−1 are attributed to the CH wagging vibration (in-plane), and the two weaker peaks at 1240 and 1269 cm−1 are attributed to the C–O stretching vibration26. The peaks at 1621 and 3072 cm−1 are assigned to the phenyl ring stretching and phenyl-hydrogen stretching modes27. The peak at 2450 cm−1 is attributed to the photoluminescence signal of benzene rings in BPA. While SERS signal was detected for BPA on both substrates, the graphitic sheets on silicon exhibited a very strong SERS enhancement compared to the silicon–only substrate. This may be attributed to π–π stacking between delocalized sp2 carbon structures of graphitic sheets and the benzene rings of BPA15,28,29.

To confirm the homogeneity of the graphitic sheet substrates for SERS, we performed a BPA (10−1 M) Raman mapping experiment. Results from each tested region (I, II, III, IV and V) showed nearly identical BPA SERS signal and demonstrates that the graphitic sheet substrate exhibits good uniformity, as shown in Supplementary Fig. S1. Quantitative detection of BPA on graphitic sheet substrates was performed by measuring the SERS signal intensity of a dilution series of BPA solutions (10−1–10−6 M) as shown in Fig. 2b. The SERS signal was very strong at 10−1 M BPA, and was still detectable even at a concentrations of 10−6 M (1 μM), which is lower than the European Union migration limit of BPA in food of 0.6 mg/kg (2.6 μM)30. To further analyze these data, we selected the peak at 1121 cm−1 as the reference, and plotted the Raman intensity (integrated peak area) versus BPA concentration on a log-log scale for quantitative analysis. Integrated peak calculations were perfomred using OriginPro software. The literature shows that a linear relationship between Log I and Log C is reasonable as the Raman intensity is proportional to surface coverage of adsorbed molecules31,32. Higher molecular concentrations lead to stronger Raman spectra with a linear relationship on a log-log plot. This allows for the calibration of our method to determine unknown concentrations of BPA solutions. Supplementary Fig. S2 shows good linearity between the Log C of BPA and Log I of the reference peaks (1121 cm−1). The linear regression gives a relationship as Log I = 5.608 + 0.203 Log C with a correlation coefficient (R2) of 0.991. This further shows that the detection limit for BPA molecules can reach as low as 1 × 10−6 M.

We next examined the utility of this method for detecting BPA leached from “real-world” samples under controlled environmental conditions. Maragou et al. suggested that BPA migration can occur when boiled water is poured into polycarbonate baby bottles, with measured BPA concentrations in the liquid ranging from 2.4 to 14.3 mg/kg4. Additionally, Nerin et al. found BPA in microwavable polycarbonate plastic containers present at a concentration of 30 μg/g in the plastic and estimated migration levels of 6.5 μg/g in foods33. In our experiments, plastic spoons (two types), baby bottles, re-sealable zipper storage bags, and airtight food containers (Fig. 3a right 1–5) were leach-tested by placing them in contact with 5 mL of boiled water (80 °C) for 1 hour. An aliquot of the collected water was then deposited onto the graphitic sheet substrates for SERS analysis to determine whether BPA had leached from the samples. As shown in Fig. 3a, the characteristic CH wagging peak (in-plane) at ~1121 cm−1 was observed for each sample (1–5), at measured concentrations of 1 × 10−5, 3.2 × 10−6, 2.0 × 10−5, 1 × 10−6, and 6.3 × 10−7 M, respectively. The BPA spectrum at the bottom of the graph is reproduced for reference from the dilution series (Fig. 2) and is 1 × 10−4 M BPA. The detection limit of our method was much lower than the typical values measured for consumer products reported by Maragou et al. and Nerin et al., thus demonstrating that this SERS-based graphitic sheet method for monitoring BPA leached from plastic materials is practical and rapid, as well as quantitative.

Figure 3
figure 3

(a) Detection of BPA using graphitic sheet substrates presents in daily plastic products by SERS spectra. (b) SERS spectra of 10−3 M BPA with various concentrations of NaCl using graphitic sheet substrate.

Salt effect

In canned foods, researchers have found that factors such as salt ion concentration can influence the migration of BPA from the internal lining of the can to the contents34. Additionally, on graphitic sheet substrates, NaCl may compete for the adsorption sites with BPA28. To examine how these factors might influence our method, we measured the SERS signal for 10−3 M BPA samples prepared with increasing NaCl concentrations of 0.025 M to 2 M NaCl (Fig. 3b). A decrease in SERS signal intensity with increasing NaCl concentration was observed, which may be explained by the occupation of active sites on the graphitic sheets by NaCl, or by a surface-charge screening effect caused by the higher ionic strength, which could reduce the detection efficiency. However, in clinical applications, BPA is monitored in human serum or urine samples where the physiologic ionic strength of NaCl is 0.14 M and 0.17 M, respectively. Samples at these NaCl concentrations were tested in our experiments (0.025 M to 2 M of NaCl), and BPA was detected, demonstrating the feasibility of the method for BPA detection in body fluids and salt solutions.

Conclusions

In this work, we report on the development of a SERS-based detection platform for BPA that uses graphitic sheets prepared by SAM methods. A significant Raman signal enhancement was observed for BPA on graphitic sheets, with a detection limit of <1 μM. We applied the method to “real-world” consumer product sample testing (Plastic spoons, baby bottles, re-sealable zipper storage bags, and airtight food containers) and were able to detect low levels of BPA in every sample, indicating that leaching had occurred under the conditions of the experiment. In NaCl, we observed good BPA detection sensitivity at NaCl concentrations of 0.025 M up to 2 M which includes NaCl concentrations typically found in body fluids. Our results demonstrate highly sensitive BPA detection, using a simple, label-free, SERS-based platform. This method has potential for applications in clinical, industrial, and consumer product testing research.

Methods

Synthesis of graphitic sheets

Graphitic sheets were fabricated from self-assembled octadecyltrichlorosilane (OTS) films on silicon35. The OTS films were annealed in a tube furnace (Lindberg/Blue M, model STF55433C–1) for 30 minutes at 300 °C, immersed into a micro tube with 1-ml pure water, then immediately placed in an ultrasonic bath (Delta DC200H) for 2 minutes (40 kHz ultrasonic frequency, 200 W power output) at room temperature. The resulting supernatant fluid was used directly as the stock solution for all experiments. Throughout the study, Milli-Q reagent-grade (type I) water (18.2 MΩ-cm@25 °C) was used.

Characterization methods

Characterization of as-prepared graphitic sheets was performed by TEM, EDS, and AFM. Samples for TEM were prepared by first depositing a droplet of stock solution onto a carbon-free, 1000-mesh copper grid (Ted Pella Inc., CA USA) and allowing the sample to dry in air. TEM images were acquired using an EOL JEM-2100, operating at 200 kV. Chemical analysis of the graphitic sheets (using the TEM samples) was carried out by EDS using a JEOL JEM-3010 linked with an eXL-II energy dispersive X-ray analysis system at a resolution of 136 eV FWHM at 5.9 keV. AFM samples were prepared by depositing a droplet of stock solution onto a clean silicon surface at room temperature and allowing them to dry. Topographic AFM images were acquired using an MFP-3DTM AFM (Asylum Research, Santa Barbara, CA, USA) operated in AC “tapping” mode under ambient conditions. A silicon cantilever (Olympus, AC240TS) with a nominal spring constant of 2 Nm−1 was used for all images using a scan rate of 1.0 Hz and an image resolution of 512 × 512 pixels.

SERS measurements

For SERS experiments, samples were prepared by dissolving BPA in ethanol (Echo Chemical, ROC) and then depositing a 2 μl aliquot of a series of concentrations (10−1, 10−2, 10−3, 10−4, 10−5, 10−6 M) on graphitic sheets on silicon, followed by drying at room temperature under ambient conditions. All Raman and SERS experiments were performed on a Raman microscope (WiTec alpha 300 R) with a 532 nm incident laser at 21.9 mW powers. A holographic grating (1800 grooves mm−1) and a 1024 × 127 pixel back-illuminated CCD detector with total accumulation times of 30 seconds were used.